301 |
ASTM D3723 - Standard Test Method for Pigment Content of Water-Emulsion Paints by Low- Temperature Ashing |
Standard Test Method for Pigment Content of Water-Emulsion Paints by Low- Temperature Ashing |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
ASTM D 3723 - 05 (Pigment content) |
1.0 |
|
|
302 |
IRS : S 63/ 2014 - PVC INSULATED UNDERGROUND, UNSCREENED CABLE FOR RAILWAY SIGNALLING |
PVC INSULATED UNDERGROUND, UNSCREENED CABLE FOR RAILWAY SIGNALLING |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
5.2 (Type Tests (Power Cable)) |
22000.0 |
|
5.15 (Visual inspection) |
250.0 |
|
5.6 (Dimensions) |
100.0 |
|
5.6.2 (Annealing Test) |
1000.0 |
|
5.6.3 (Test for Correspondence of Cores) |
100.0 |
|
5.7 (Conductor Resistance Test) |
1500.0 |
|
5.8.1 (Dimensions:Test for Armour Wires/Strips/Tapes) |
200.0 |
|
5.8.2 (Tensile Strength :Test for Armour Wires/Strips/Tapes) |
750.0 |
|
5.8.2 (Percentage Elongation:Test for Armour Wires/Strips/Tapes) |
750.0 |
|
5.8.5(ii)(a) (Mass of Zinc Coating:Test for Armour Wires/Strips/Tapes) |
1500.0 |
|
5.8.5(ii)(b) (Uniformity of Zinc Coating:Test for Armour Wires/Strips/Tapes) |
1500.0 |
|
5.8.6 (Resistivity Test:Test for Armour Wires/Strips/Tapes) |
1500.0 |
|
5.8.8 (Closeness of Armour Wires / Strips:Test for Armour Wires/Strips/Tapes) |
200.0 |
|
5.9 (Test for Thickness of Insulation and Sheath) |
1000.0 |
|
5.10.1(ii) (Tensile strength-Before Ageing:Physical tests for insulation, inner & outer sheaths) |
750.0 |
|
5.10.1(ii) (Elongation percentage-Before Ageing:Physical tests for insulation, inner & outer sheaths) |
750.0 |
|
5.10.1(ii) (Tensile strength-After Ageing:Physical tests for insulation, inner & outer sheaths) |
1000.0 |
|
5.10.1(ii) (Elongation percentage-After Ageing:Physical tests for insulation, inner & outer sheaths) |
1000.0 |
|
5.10.12 (Shrinkage test:Physical tests for insulation, inner & outer sheaths) |
500.0 |
|
5.11 (The period of burning after removal of flame: Flammability test) |
250.0 |
|
5.11 (Decomposed length of sample: Flammability test) |
250.0 |
|
5.12.1.1 (High voltage test :Signalling Cable) |
3000.0 |
|
5.14.1 (AC test:Water Immersion) |
3000.0 |
|
5.13.3 (Insulation Resistance test: Signalling Cable) |
2000.0 |
|
|
303 |
IS 14268 (2022) - Uncoated stress relieved low relaxation seven - Wire (Ply) strand for prestressed concrete - Specification (First Revision) |
Uncoated stress relieved low relaxation seven - Wire (Ply) strand for prestressed concrete - Specification (First Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
6.1 (Nominal Mass) |
1500.0 |
|
6.1 (Nominal Diameter ) |
1000.0 |
|
6.2.3 (Elongation) |
1000.0 |
|
6.2.2 (0.2% Proof Load) |
1000.0 |
|
6.2.2 (Breaking Strength) |
3000.0 |
|
4.2 (Length of lay for dia 15.2mm) |
500.0 |
|
4.2 (Centre wire shall have 1.5% greater in diameter than the surrounding wires - IS 14268: 2022.) |
1000.0 |
|
4.1 (Phosphorus, % by mass) |
600.0 |
|
4.1 (Sulphur, % by mass) |
600.0 |
|
4.5 (Workmanship and Finish) |
1000.0 |
|
6.1 (Nominal Area ) |
1000.0 |
|
4.1.2 (Chemical composition (Annexure for NABL parameters)) |
3500.0 |
|
4 (Chemical composition (Annexure for non-NABL parameters)) |
3000.0 |
|
Table 2 (Cl 6.2.1, Cl 6.2.2, Cl 6.3) (0.2% Proof Load, Breaking Strength of Strand, Total Elongation.) |
3000.0 |
|
Note 1 (Modulus of Elasticity, N/mm2) |
1000.0 |
|
|
304 |
RDSO IRS S 63/2014 : Part 0 : Sec Revision 4 (2014) - PVC Insulated,underground, unscreened cable for Railway Signalling |
PVC Insulated,underground, unscreened cable for Railway Signalling |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
305 |
IS 5410 (2013) - Cement paint - Specification (Second Revision) |
Cement paint - Specification (Second Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
4.8 ix (Recoating properties) |
1200.0 |
|
4.8 viii (Pot life of mixed paint) |
1200.0 |
|
4.8 vii (Water repellency) |
1200.0 |
|
4.8 vi (Resistance to dry rubbing) |
1200.0 |
|
4.8 v (Residue on sieve % by mass) |
1200.0 |
|
4.8iii (Colour) |
1200.0 |
|
4.8 ii (Finish) |
1200.0 |
|
4.8 i (Drying time Hard dry) |
1200.0 |
|
4.7 (Keeping properties) |
5000.0 |
|
Cl 4.4 (Lead Restriction) |
1200.0 |
|
Cl 4.1 (Composition) |
3500.0 |
|
|
306 |
Berger Customer Specification -NTH ER Paint 1 (2022) - Berger Customer Specification -NTH ER Paint 1 |
Berger Customer Specification -NTH ER Paint 1 |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Shelf life @ 30 °C
For 12 Months both liquid and powder) |
10000.0 |
|
|
307 |
Custom specification Paint coating - Custom specification Paint coating Fire retardant test as per customer requirement |
Custom specification Paint coating Fire retardant test as per customer requirement |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
Custom specification for paint coating (Surface flame spreading/fire retardant test for 0 -1 hour) |
3000.0 |
|
Custom specification for paint coating (surface flame spreading/fire retardant test for 1 - 2 hours) |
5000.0 |
|
|
308 |
IS 1964:2001 (2001) - Methods for Determination of Mass per Unit Lenght and Mass per Unit Area of Fabrics |
Methods for Determination of Mass per Unit Lenght and Mass per Unit Area of Fabrics |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
Method-A (Grammage of Fabric (GSM)) |
1000.0 |
|
|
309 |
IRS S 63 (2014) - PVC Insulated underground unsereened cable for railway signaling |
PVC Insulated underground unsereened cable for railway signaling |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
5.6 (Dimensions of Signaling Cable) |
500.0 |
|
5.7 (Conductor Resistance Signaling Cable) |
1000.0 |
|
5.8 (Tensile Strength of Armour) |
1000.0 |
|
5.1 (Thickness of inner sheath) |
500.0 |
|
5.1 (Thickness of Outer Sheath) |
500.0 |
|
5.8 (Dimension of Armour ( Signaling Cable)) |
500.0 |
|
5.8 (Percentage (%) elongation Armour tape(signaling Cable)) |
500.0 |
|
5.8 (Percentage (%) elongation Armour wire(signaling Cable)) |
500.0 |
|
5.8.6 (Resistivity on Armour ( Signaling Cable)) |
1000.0 |
|
5.1 (Tensile Strength of Insulation before ageing) |
500.0 |
|
5.1 (Tensile Strength of Insulation after ageing) |
1000.0 |
|
5.10.2 (Percentage (%)Shrinkage) |
1000.0 |
|
5.10.4 (Loss of Mass of Insulation and sheath) |
1000.0 |
|
5.10.4 (Loss of Mass of Insulation and sheath) |
1000.0 |
|
5.10.11 (Thermal stability of Insulation and Sheath) |
1000.0 |
|
5.11 (Period of burning after removal of flame) |
1000.0 |
|
5.11 (Decomposed length of sample) |
1000.0 |
|
5.12 (High Voltage in Air 4 kV AC) |
1000.0 |
|
5.13.3 (Insulation Resistance in Air ( Signaling Cable)) |
1000.0 |
|
5.14 (AC High Voltage Test 8 kV( Water Immersion)) |
1000.0 |
|
|
310 |
RDSO IRS S 63/2015 : Part 1 : Sec Revision 4 (2014) - PVC Insulated,underground, unscreened cable for Railway Signalling |
PVC Insulated,underground, unscreened cable for Railway Signalling |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
311 |
IS:3025 - Methods of sampling and test (Physical & chemical) for water and waste water |
Methods of sampling and test (Physical & chemical) for water and waste water |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
CL 8 (Part 44,58,11,16 &17 ) Essential Parameters (Please see Annexure) |
12000.0 |
|
6,Table1 ICP-OES Elements (Please see Annexure) |
7000.0 |
|
Cl 8 Essential Parameters as per NMCG Requirement (Cl 8 -Essential Parameters as per NMCG Requirement (Please see Annexure)) |
10000.0 |
|
APHA-23 edition Microbiological Parameters as per NMCG(Please see Annexure) (APHA-23 edition Microbiological Parameters as per NMCG(Please see Annexure)) |
2000.0 |
|
|
312 |
IS 13730(Part-9):1994,Reaffirmed 2005. (1994) - Specification for Particular Types of Winding Wires:Polyester Enamelled Round Aluminium Wire, Class 130 |
Specification for Particular Types of Winding Wires:Polyester Enamelled Round Aluminium Wire, Class 130 |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
4 (Dimensions) |
1000.0 |
|
5 (Electrical Resistance) |
2000.0 |
|
6 (Elongation) |
1500.0 |
|
9 (Heat Shock) |
500.0 |
|
4 (Dimensions) |
1000.0 |
|
13 (Break Down Voltage Test( At Room Temperature)) |
3000.0 |
|
8 (Mandrel winding test) |
1500.0 |
|
8 (Stretching test) |
1500.0 |
|
Tests (i)Measurement of diameter of conductor, ii)Measurement of increase in diameter,iii)Measurement of overall diameter,iv) Measurement of Elongation at break, v)Mandrel Winding Test,vi)Tensile Test on Conductor and vii)Weight check.) |
10000.0 |
|
|
313 |
MDTS : 094 Rev:01 (2002) - TECH SPECIFICATIONS FOR PAINTING SYSTEM FOR PASSENGER COACHES BUILT AT RCF,KAPURTHALA |
TECH SPECIFICATIONS FOR PAINTING SYSTEM FOR PASSENGER COACHES BUILT AT RCF,KAPURTHALA |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
Cl No. 3.1 FOR PRIMER (Epoxy metal primer) (Please see Annexure) |
25000.0 |
|
Cl No. 3.2 FOR Polyester based Kniffing Putty (Please see Annexure) |
8000.0 |
|
Cl No. 3.3 FOR Two component PUR PRIMER (Please see Annexure) |
25000.0 |
|
Cl No. 3.4 FOR Two component POLYURETHANE UNDERCOAT( PRIMING PAINT)PURER (Please see Annexure) |
12000.0 |
|
Cl No. 3.5 FOR Two component PUR POLYURETHANE BASED TOP COAT (Please see Annexure) |
35000.0 |
|
Cl No. 3.6 FOR Two component EpoxyHigh Build Paint ElastifiedR (Please see Annexure) |
40000.0 |
|
|
314 |
RDSO M&C/ PCN/ 100/ 2018 (2018) - Specification for Epoxy Cum Polyurethane Painting System (Two Pack) for the Exterior Painting of Railway Coaches |
Specification for Epoxy Cum Polyurethane Painting System (Two Pack) for the Exterior Painting of Railway Coaches |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
Chapter V/Cl. 3.2 (Humidity test.) |
11000.0 |
|
Chapter V/Cl. 3.2 (Accelerated Tests Resistance to water) |
1500.0 |
|
Chapter V/Cl. 3.2 (Accelerated Tests Resistance to solvents) |
1500.0 |
|
Chapter V/Cl. 3.2 (Accelerated Tests Resistance to oil) |
1500.0 |
|
Chapter V/Cl. 3.2 (Accelerated Tests Resistance to 20% caustic potash (weight by volume)) |
1500.0 |
|
Chapter V/Cl. 3.2 (Accelerated Tests (a) Resistance to 30% Sulphuric acid (weight by volume)) |
1500.0 |
|
Chapter V/Cl. 3.2 (Gloss at 60 degree angle of incidence) |
1200.0 |
|
Chapter V/Cl. 3.2 (Viscosity (Efflux time by Ford cup No. 4 ) at 27 degree C) |
1200.0 |
|
Chapter V/Cl. 3.2 (Fineness of grind) |
1200.0 |
|
Chapter V/Cl. 3.2 (Theoretical Spreading rate) |
1200.0 |
|
Chapter V/Cl. 3.2 (Pot life(After induction time)ii) 40 ± 2 Deg C) |
2000.0 |
|
Chapter V/Cl. 3.2 (Pot life (After induction time) at i) 27 ± 2 Deg C) |
1500.0 |
|
Chapter V/Cl. 3.2 (Mass in Kg/10 litres) |
1200.0 |
|
Chapter V/Cl. 3.2 (Keeping Properties for both the packs) |
5000.0 |
|
Chapter V/Cl. 3.2 (Flash Point (b) Component B) |
1200.0 |
|
Chapter V/Cl. 3.2 (Flash Point (a) Component A) |
1200.0 |
|
Chapter V/Cl. 3.2 (Flexibility & Adhesion (6.25mm mandrel)) |
1200.0 |
|
Chapter V/Cl. 3.2 (Scratch hardness (1.5 Kg LOAD)) |
1200.0 |
|
Chapter IV / Table I (Volume solids) |
2000.0 |
|
Chapter V/Cl. 3.2 (Dry film thickness/Per coat) |
1200.0 |
|
Chapter V/Cl. 3.2 (Colour) |
1200.0 |
|
Chapter V/Cl. 3.2 (Finish) |
1200.0 |
|
Chapter V/Cl. 3.2 (Consistency) |
1200.0 |
|
Chapter V/Cl. 3.2 (Drying time c) Hard Dry at 70 Deg C) |
1200.0 |
|
Chapter V/Cl. 3.2 (Drying time b) Hard Dry) |
1200.0 |
|
Chapter V/Cl. 3.2 (Drying time a) Surface Dry) |
1200.0 |
|
Chapter V/Cl. 3.2 (Identification of polyisocyanates) |
3000.0 |
|
|
315 |
IS 733 (1983 RA 2022) - SPECIFICATION FOR WROUGHT ALUMINIUM AND ALUMINIUM ALLOY BARS, RODS AND SECTIONS
(FOR GENERAL ENGINEERING PURPOSES) |
SPECIFICATION FOR WROUGHT ALUMINIUM AND ALUMINIUM ALLOY BARS, RODS AND SECTIONS
(FOR GENERAL ENGINEERING PURPOSES) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
5.1.1 a Chemical composition (Aluminium (as Al )content,% by mass) |
3000.0 |
|
5.1.1 b Chemical composition (Copper (as Cu)content,% by mass) |
500.0 |
|
5.1.1 C Chemical composition (Magnesium(as Mg ) content,% by mass) |
500.0 |
|
5.1.1 d Chemical composition (Silicon (as Si) content,% by mass) |
500.0 |
|
5.1.1 e Chemical composition (Iron (as Fe) content,% by mass) |
500.0 |
|
5.1.1 f Chemical composition (Manganese (as Mn) content,% by mass) |
500.0 |
|
5.1.1 g Chemical composition (Zinc (as Zn ) content,% by mass) |
500.0 |
|
5.1.1 h Chemical composition (Titanium (as Ti) content,% by mass) |
500.0 |
|
5.1.1 i Chemical composition (Chromium (as Cr) content,% by mass) |
500.0 |
|
5.1.1 j Chemical composition (Vanadium (as V) content,% by mass) |
500.0 |
|
7 (Dimension) |
1000.0 |
|
9.1 (Tensile Strenth) |
2000.0 |
|
9.1 (0.2% Proof Stress) |
1000.0 |
|
9.1 (Elongation) |
1000.0 |
|
0 (Anodic Coating) |
2000.0 |
|
5 (Chemical composition, % by mass) |
6000.0 |
|
0 (Weight, kg) |
1000.0 |
|
|
316 |
RDSO Drg.No. SK-94254 Alt-3 /IS:1030 - CARBON STEEL CASTINGS FOR GENERAL ENGINEERING PURPOSES |
CARBON STEEL CASTINGS FOR GENERAL ENGINEERING PURPOSES |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
Cl no. 8.1 Table 1 (Carbon) |
1200.0 |
|
|
317 |
IS 2039(Part1 to 3) (1991) - Steel Tubes for Bicycle and Cycle Rickshaws |
Steel Tubes for Bicycle and Cycle Rickshaws |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
9 (Dimensions) |
20000.0 |
|
|
318 |
JIS K 5659:2018 (2018) - LONG DURABLE PAINTS FOR STEEL STRUCTURES |
LONG DURABLE PAINTS FOR STEEL STRUCTURES |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
Clause 5 Table 2 Top Coat Type A (Please see Annexure) |
40000.0 |
|
Clause 5 Table 2 Intermediate CoatType A (Please see Annexure) |
40000.0 |
|
Clause 5 Table 2 Top Coat Type B (Please see Annexure) |
1.0 |
|
Clause 5 Table 2 Type B Intermediate Coat (Please see Annexure) |
1.0 |
|
5 Table 2 LONG DURABLE PAINTS FOR STEEL STRUCTURES ( ZINC RICH PRIMER) TYPE A (Please see Annexure) |
55000.0 |
|
5 Table 2 (LONG DURABLE PAINTS FOR STEEL STRUCTURES( Intermediate) TYPE A (Please see Annexure) |
45000.0 |
|
5 Table 2 LONG DURABLE PAINTS FOR STEEL STRUCTURES (Undercoat) TYPE A (Please see Annexure) |
20000.0 |
|
5 Table 2 LONG DURABLE PAINTS FOR STEEL STRUCTURES( FINISH) TYPE A (Please see Annexure) |
50000.0 |
|
|
319 |
IS 894 (2023) - SPECIFICATION FOR HANDLOOM WOOL BLANKETS BRICK RED |
SPECIFICATION FOR HANDLOOM WOOL BLANKETS BRICK RED |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
Table 2 (Fibre Composition) |
2000.0 |
|
Table-1 (Ends per inch) |
1000.0 |
|
Table-1 (Picks per inch) |
1000.0 |
|
Table-1 (Breaking Load, kgs) |
2000.0 |
|
Table-1 (Weight per square meter (GSM)) |
1000.0 |
|
Table-1 (Type of Weaves) |
1000.0 |
|
Firm's Requirement (Weight of Blanket, g) |
1000.0 |
|
Firm's Requirement (Satin Piping Stitching/cms.) |
1000.0 |
|
|
320 |
IS 16103 (Part-2): 2012 (2012) - LED Modules for General Lighting |
LED Modules for General Lighting |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
Clause 10 (Measurement of power Input) |
7500.0 |
|
|
321 |
NS/NR/RPPT (2022) - Test for Writing/Notice/Display Boards, Low Dust Chalk, Duster and Acrylic Desk etc |
Test for Writing/Notice/Display Boards, Low Dust Chalk, Duster and Acrylic Desk etc |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
NA (Galvanized Steel Sheet Thickness) |
1000.0 |
|
NA (Zinc Coating (in micron)) |
2000.0 |
|
NA (Length) |
500.0 |
|
NA (Dimension) |
100.0 |
|
NA (Colour) |
1000.0 |
|
NA (Purpose (Laminated Sheet Green)) |
1000.0 |
|
NA (Purpose of Chalk for Writing) |
1000.0 |
|
NA (Application /Usage) |
1000.0 |
|
NA (Purpose (Laminated Sheet White)) |
1000.0 |
|
NA (Coating Thickness Top Side (mm)) |
1000.0 |
|
NA (Coating Thickness Bottom Side (mm)) |
1000.0 |
|
NA (Type of Duster (Magnetic or Non-magnetic)) |
1000.0 |
|
NA (Zinc Coating as per IS 277(g/sq.meter)) |
2000.0 |
|
NA (Bulk Density) |
1000.0 |
|
NA (Density) |
1000.0 |
|
NA (Gloss of Sheet Top Side @ 60deg) |
1000.0 |
|
|
322 |
AASHTO T 166 (for BC & DBM cores) - AASHTO T 166-Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Saturated Surface-Dry Specimens |
AASHTO T 166-Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Saturated Surface-Dry Specimens |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Test for bulk specific gravity (Gmb) of DBM (on the lines of AASHTO T 166)) |
2500.0 |
|
2 (Test for bulk specific gravity (Gmb) of BC (on the lines of AASHTO T 166)) |
2500.0 |
|
|
323 |
IS 383 for coarse aggregate (2016) - Coarse and fine aggregate for concrete |
Coarse and fine aggregate for concrete |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
14 (Test for Alkali aggregate reaction-(IS 2386(7):1963):Chemical method) |
3000.0 |
|
5.7 TABLE 3 (TOTAL ALKALI CONTENT as Na2O) |
1200.0 |
|
5.7 TABLE 3 (TOTAL SULPHATE CONTENT as SO3) |
1200.0 |
|
5.7 TABLE 3 (ACID SOLUBLE CHLORIDE CONTENT) |
1200.0 |
|
12 (Test for Deleterious Materials(IS 2386(Part 2):1963)) |
2000.0 |
|
|
324 |
IS 1199 (4) - Methods of sampling and analysis of concrete |
Methods of sampling and analysis of concrete |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
10 (Ratio of Cement :Aggregates) |
5000.0 |
|
|
325 |
IS 3989 (2009) - Centrifugally Cast (Spun) Iron Spigot and Socket Soil, Waste and Ventilating Pipes, Fittings and Accessories |
Centrifugally Cast (Spun) Iron Spigot and Socket Soil, Waste and Ventilating Pipes, Fittings and Accessories |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
3.3 (Brinell Hardness (HBW)) |
2000.0 |
|
4 (Hammer Test) |
1000.0 |
|
5 (Hydrostatic Test) |
5000.0 |
|
6.3 (Thickness and OD of the pipe) |
1000.0 |
|
6.3 (Mass of the Pipe) |
1000.0 |
|
0 (Visual Check) |
1000.0 |
|
0 (Ovality) |
1000.0 |
|
0 (Length) |
1000.0 |
|
0 (Marking) |
500.0 |
|
0 (Class of Pipe) |
500.0 |
|
0 (Tensile Strength) |
2000.0 |
|
0 (Ring Test) |
2000.0 |
|
0 (Thickness) |
1000.0 |
|
8 (Coating Test) |
2000.0 |
|
|
326 |
1239 (2011) - Steel Tubes, Tubulars and other Steel Fittings, PART 2 STEEL PIPE FITTINGS |
Steel Tubes, Tubulars and other Steel Fittings, PART 2 STEEL PIPE FITTINGS |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
9 (Dimension,mm.) |
1000.0 |
|
13.1.1 (Mass of Zinc Coating) |
2000.0 |
|
13.1.2 (Uniformity of Zinc Coating) |
500.0 |
|
14 (Workmanship, Visual) |
500.0 |
|
3.1 (Sulphur (% by mass)) |
700.0 |
|
3.1 (Phosphorous (% by mass)) |
700.0 |
|
|
327 |
IRS : TC 30-05 - UNDERGROUND RAILWAY JELLY FILLED QUAD CABLES FOR SIGNALLING AND TELECOM INSTALLATIONS |
UNDERGROUND RAILWAY JELLY FILLED QUAD CABLES FOR SIGNALLING AND TELECOM INSTALLATIONS |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
3.1.1 (Diameter mm (Nominal) - 0.90
Tolerance mm - +-0.02
Maximum Resistance Ohm/ Km at 20 deg C
Each core - 28
Loop - 56) |
1000.0 |
|
3.1.2 (The conductor shall be uniformly drawn, circular in Closs-section, uniform III qiI<lhty, free
from splits, cracks, corrosion and other surface imperfectIons) |
100.0 |
|
3.1.3 (No joints shall be made in the conductor except in exceptional cases where It IS
necessary to join conductors during manufacture, it shall fulfill. the requirements of clause
3.1.) |
1.0 |
|
5.5.1 (The diameter of the conductor shall be measured on the finished sample. The measurement shall be made atleast at three different points with two readings at 90 degree along the length of the sample.) |
1.0 |
|
5.5.2 (A sample of wire taken from finished cable, when tested shall have elongation at fracture of not less than 23 d for diameter O.9 mm) |
1.0 |
|
5.7.1 (Determination of the thickness of insulation of round cores and sheath shall be made on a
representative sample of the cable approximately one meter long taken from the drum length of the cable.) |
1.0 |
|
5.7.2 (The measurement in case of conductor insulation, inner, intermediate and outer sheath shall
be made at three different points at interval of not less than 75 mm along the length of the
sample and at each point the minimum thickness or the'insulation inner, intermediate &
outer sheath shall be measured along with two more readings made at equidistant points
around the periphery.) |
1.0 |
|
3.8.3 (The number and the size of the aluminium wires/strips used for screening shall be such as to comply with the requirements of Cl 5.9.9) |
200.0 |
|
3.8.4 (The layer of the aluminium wires/ strips used for screening shall be compact and the length of the lay shall be high.) |
200.0 |
|
3.8.5 (The minimum tensile strength of Aluminium screen shall be 15 Kg/ Sqmm) |
200.0 |
|
3.8.6 (The innermost layer of the screening shall have left hand lay and the sucessive layer shall be laid with opposite lay.) |
200.0 |
|
3.8.7 (Drift expansion test to IS 2335-1985 shall be carried out on a test piece of length twice the external dia of the tube by conical mandrel having height three times its base diameter.) |
200.0 |
|
3.8.8 (Flattening test to IS. 2328- 1983 shall be carried out on a test piece of not less than 50 mm long cut from each selected tube.) |
200.0 |
|
3.9.1 (The aluminium screen shall be wrapped with a single layer of woven tape impregnated with Barium Chromate with minimum 20% overlap.) |
500.0 |
|
3.9.2 (The tape used shall be fine woven cloth tape of about 0.15 mm thickness.) |
200.0 |
|
3.10.7 (The test shall be conducted on PVC intermediate sheath in accprdance with BS 6169 or any approved method.) |
1000.0 |
|
5.8.1.1 (The test shall be conducted in accordance with the procedure laid down in IS 10810 (Part-7)) |
500.0 |
|
5.8.1.2 (The values after ageing for tensile strength and % elongation shall not be less than given in Cl 5.8.1) |
500.0 |
|
5.8.1.3 (The values of all the four samples in case of each sheath shall be averaged and then % variation calculated.) |
1.0 |
|
5.8.2.4 (A sample shall be cut from the cable sheath, 50 mm long measured along the axis. 12 mm wide and the same thickness as the cable sheath) |
1000.0 |
|
5.8.11 (The test to be conducted in accordance with the procedure laid down in IS 10810 (Part 60)) |
500.0 |
|
3.3 (i) Four conductors insulated as above shall be stranded to form a star, quad. each;
conductors diagnolly opposite forming one pair and the remaining two diagonally OPPOS);
conductors furming the second pairs of the quad.
ii) The lays of the conductors forming the quads shall differ for adjacent quads. The lay of the
conductor shall be so chosen as to ensure that the cross talk between the pairs in the cable minimum.) |
1000.0 |
|
3.4 (Each quad shall retain its size) |
1.0 |
|
3.12 (Visual Inspection and Marking) |
100.0 |
|
5.8.22 (Visual Inspection and Marking) |
100.0 |
|
5.9.1 (HV Test to be carried out) |
2000.0 |
|
5.9.2 (Insulation resistance Test) |
1000.0 |
|
5.9.3 (Conductor Resistance Test) |
1.0 |
|
5.6.3.1 (Mass of Zinc Coating test) |
3000.0 |
|
5.8.2.3 (Shrinkage Test of PE Insulation) |
1000.0 |
|
5.8.2.2 (Shrinkage Test of PVC Sheaths) |
1000.0 |
|
|
328 |
IS 191 (2007) - Copper - Specification (Fourth Revision) |
Copper - Specification (Fourth Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
7.1 (Selenium+Tellurium) |
2000.0 |
|
7.1 (Zinc ) |
1000.0 |
|
7.1 (Tin ) |
1000.0 |
|
7.1 (Tellurium) |
1000.0 |
|
7.1 (Selenium) |
1000.0 |
|
7.1 (Oxygen) |
5000.0 |
|
7.1 (Lead ) |
1000.0 |
|
7.1 (Bismuth) |
1000.0 |
|
7.1 (Antimony) |
1000.0 |
|
7.1 (Arsenic ) |
2000.0 |
|
7.1 (Nickel ) |
1000.0 |
|
7.1 (Sulphur) |
1000.0 |
|
7.1 (Iron ) |
1000.0 |
|
7.1 (Phosphorus ) |
1000.0 |
|
7.1 (Silver ) |
1000.0 |
|
7.1 (Copper + Silver ) |
2000.0 |
|
|
329 |
IS 110 (2017) - Ready mixed paint, brushing, grey filler, for enamels for use over primers - Specification (Third Revision) |
Ready mixed paint, brushing, grey filler, for enamels for use over primers - Specification (Third Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
4.3xiii (Keeping properties) |
5000.0 |
|
|
330 |
IS 158 (2015) - Ready mixed paint, brushing, bituminous, black, acid, alkali and heat resisting - Specification (Fourth Revision) |
Ready mixed paint, brushing, bituminous, black, acid, alkali and heat resisting - Specification (Fourth Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
4.3,xvi (Keeping properties) |
500.0 |
|
4.3,xv (Flash Point) |
500.0 |
|
4.3,xiv (Resistance to heat) |
200.0 |
|
4.3,xiii (Resistance to alkali) |
1000.0 |
|
4.3,xii (Resistance to acid) |
2000.0 |
|
4.3,xi (Volatile matter, percent by mass) |
200.0 |
|
4.3,x (Protection against corrosion under conditions of condensation) |
2000.0 |
|
4.3, ix (Stripping Test) |
1000.0 |
|
4.3, viii (Flexibility and adhesion, bend test with 6.25
mm dia mandrel and type 1 apparatus) |
1000.0 |
|
4.3,vii (Water Content,percent by mass) |
100.0 |
|
4.3,vi (Mass, kg/10litre) |
100.0 |
|
4.3,v (Colour) |
100.0 |
|
4.3,iv (Wet opacity) |
500.0 |
|
4.3,iii (Finish) |
100.0 |
|
4.3,ii (Consistency) |
1000.0 |
|
4.3,i (Drying time : Hard dry) |
1000.0 |
|
4.2 (Lead Restrictions) |
1500.0 |
|
|