331 |
Customer Specified - Specification |
Specification |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
- (Power Factor Measurement) |
3000.0 |
|
Clause No.10 (Measurement of Power Input(The Carried out on the lines of Clause No.7 of IS 16103(part-2):2012) |
3000.0 |
|
As per Bank GTP. (Verification of Functional checks on Note Authentication or cum sorting Machine with 1+1) |
35000.0 |
|
As per Bank GTP. (Verification of Functional checks on Note Authentication or cum sorting Machine with 2+1) |
40000.0 |
|
8.2 (Railway Signalling Cable) |
131000.0 |
|
8.2 (Underground Railway Jelly Filled Telecom Quad Cable for signalling and Telecom) |
101500.0 |
|
Test1 (Test for overall dimension and thickness of insulation/sheath, Tensile strength for insulation(Before & After Ageing), Loss of mass test for insulation & Sheath, Hot deformation test for insulation & Sheath and Thermal stability test for insulation & Sheath) |
13500.0 |
|
Relevant Clauses of IS 1475(Part-1) (Marking,Maximum operating conditions, Cooling capacity rating test, High Voltage Test, Insulation Resistance and components and their materials.) |
30000.0 |
|
Central Vista project (Test3) |
26000.0 |
|
IS 3854 (Tests) |
10000.0 |
|
Clause 17.1 (i)(b),(ii),(iii) (Conductor resistance test,Test for armouring wires and Tests for thickness of insulation and sheath.) |
9000.0 |
|
Test7 (High Voltage Test) |
4000.0 |
|
Scientist Visiting Charges (---) |
10000.0 |
|
14255 (Acceptance Tests) (Tests) |
16500.0 |
|
IS 555:1979,Reaffirmed Year : 2020,Amendment No.2 (Electric Wall Mounted Fan) (Insulation Resistance) |
2500.0 |
|
Smoke Density Test (Test) |
40000.0 |
|
Kolkata Custom (Visula Inspection/Verification) |
10000.0 |
|
Test13 (Tests) |
6500.0 |
|
IEC 60898(Part-1):2015 (i)Resistance to Abnormal Heat and to Fire(9.15) and ii)Measurement of Temperature Raise (Cl.9.8.2)) |
16000.0 |
|
IS 1293 (Tests) |
10000.0 |
|
Test (Tests) |
60660.0 |
|
Witness (Tests) |
- |
|
Test16 (Tests) |
36000.0 |
|
Test16 (Tests) |
12000.0 |
|
Test17 (Tests) |
27000.0 |
|
Test17 (Tests) |
30500.0 |
|
Test18 (Tests) |
26000.0 |
|
Test19 (Type Tests) |
47200.0 |
|
Test20 (Tests) |
27000.0 |
|
ILC Test-NN (ILC Tests) |
- |
|
ILC Tests-NL (ILC Tests) |
- |
|
Test (Tests) |
10000.0 |
|
Tests (Tests at Clause Numbers 5.6.1,5.6.2,5.7,5.8.1,2.8.2,5.8.5(ii),5.8.6,5.9,5.10.1(ii),5.10.2,5.10.3, 5.10.4,5.10.10,5.10.11, 5.11, 5.12.1,5.13.1,5.14.1,5.14.2 and 5.15,4.2 of IRS S:63/2014(Rev 4.0).) |
130500.0 |
|
Tests (Tests as per Clause Numbers 5.5,5.6,5.7,5.8.2,5.8.3,5.8.4,5.8.10,5.8.11,5.8.14,5.8.15,5.9.1,5.9.2,5.9.2.3 and 5.9.3 of IRS TC:30-2005(Ver-1),Amendment No.4.) |
100500.0 |
|
Tests (Tests at Clause Numbers 5.6.1,5.6.2,5.7,5.8.1,2.8.2,5.8.5(ii),5.8.6,5.9,5.10.1(ii),5.10.2,5.10.3,
5.10.4,5.10.10,5.10.11,5.11,5.12.1,5.13.1,5.14.1,5.14.2 and 5.15,4.2 of IRS S:63/2014(Rev 4.0).) |
40500.0 |
|
Tests (Tests as per Cl.Nos.5.6.1,5.6.2,5.7,5.8.1,2.8.2,5.8.5(ii),5.8.6,5.9,5.10.1(ii),5.10.2,5.10.3,5.10.4, 5.10.10, 5.10.11,5.11,5.12.1,5.13.1,5.14.1,5.14.2,5.15,4.2 as per IRS S:63/2014(Rev 4.0).) |
70500.0 |
|
DMRC (DMRC Tests) |
152500.0 |
|
DMRC (DMRC Tests) |
150500.0 |
|
DMRC (DMRC Tests) |
146500.0 |
|
Test (Test) |
1500.0 |
|
Verification of Functional checks (Verification of Functional checks on Note sorting Machine,2+1 as per Customer GTP) |
40000.0 |
|
Verification of Functional checks (Verification of Functional checks on Note sorting Machine,1+1 as per Customer GTP) |
35000.0 |
|
Verification of Functional checks (Verification of Functional checks on Note sorting Machine,4+1 as per Customer GTP) |
50000.0 |
|
Verification of Functional checks (Verification of Functional checks on Note sorting Machine,4+2 as per Customer GTP) |
50000.0 |
|
Verification of Functional checks (Verification of Functional checks on Authentication cum Value Counting Machines as per Customer GTP) |
35000.0 |
|
Scientist Visiting Charges (---) |
5000.0 |
|
13.4 of IEC 60529. (Dust test for first characteristic numeral 6) |
10000.0 |
|
Sl.No(i)(b) of Cl10.1 (Breaking Load Test on Messenger Conductor) |
1500.0 |
|
|
332 |
NTH/NR/CM/CUSTM/02 - Fire retardant test on Bunsen flame for 2 hours |
Fire retardant test on Bunsen flame for 2 hours |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
Customer specification (Please see Annexure) |
3000.0 |
|
|
333 |
Customer specification - Flame retardant test for 4 hours |
Flame retardant test for 4 hours |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
27600 (FLAME RETARDANT TEST FOR 4 Hrs.) |
3000.0 |
|
|
334 |
ETI/OHE/50(6/97) re-designated to TI/SPC/OHE/CAT(Cu-Cd)/0971 (2021) - Technical Specification for Cadmium Copper Conductors for Over Head Railway Traction. |
Technical Specification for Cadmium Copper Conductors for Over Head Railway Traction. |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
8.3.6 (Tensile Strength) |
19000.0 |
|
8.3.7 (Wrapping Test on Wire) |
1000.0 |
|
8.3.8, 4.1.1 Table-2 (Chemical Composition as per clause 8.3.8, 4.1.1 Table-2 of TI/SPC/OHE/CAT(Cu-Cd)/0971 (2021)) |
5000.0 |
|
|
335 |
ASTM D3723 - Standard Test Method for Pigment Content of Water-Emulsion Paints by Low- Temperature Ashing |
Standard Test Method for Pigment Content of Water-Emulsion Paints by Low- Temperature Ashing |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
ASTM D 3723 - 05 (Pigment content) |
1.0 |
|
|
336 |
IRS : S 63/ 2014 - PVC INSULATED UNDERGROUND, UNSCREENED CABLE FOR RAILWAY SIGNALLING |
PVC INSULATED UNDERGROUND, UNSCREENED CABLE FOR RAILWAY SIGNALLING |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
5.2 (Type Tests (Power Cable)) |
22000.0 |
|
5.15 (Visual inspection) |
250.0 |
|
5.6 (Dimensions) |
100.0 |
|
5.6.2 (Annealing Test) |
1000.0 |
|
5.6.3 (Test for Correspondence of Cores) |
100.0 |
|
5.7 (Conductor Resistance Test) |
1500.0 |
|
5.8.1 (Dimensions:Test for Armour Wires/Strips/Tapes) |
200.0 |
|
5.8.2 (Tensile Strength :Test for Armour Wires/Strips/Tapes) |
750.0 |
|
5.8.2 (Percentage Elongation:Test for Armour Wires/Strips/Tapes) |
750.0 |
|
5.8.5(ii)(a) (Mass of Zinc Coating:Test for Armour Wires/Strips/Tapes) |
1500.0 |
|
5.8.5(ii)(b) (Uniformity of Zinc Coating:Test for Armour Wires/Strips/Tapes) |
1500.0 |
|
5.8.6 (Resistivity Test:Test for Armour Wires/Strips/Tapes) |
1500.0 |
|
5.8.8 (Closeness of Armour Wires / Strips:Test for Armour Wires/Strips/Tapes) |
200.0 |
|
5.9 (Test for Thickness of Insulation and Sheath) |
1000.0 |
|
5.10.1(ii) (Tensile strength-Before Ageing:Physical tests for insulation, inner & outer sheaths) |
750.0 |
|
5.10.1(ii) (Elongation percentage-Before Ageing:Physical tests for insulation, inner & outer sheaths) |
750.0 |
|
5.10.1(ii) (Tensile strength-After Ageing:Physical tests for insulation, inner & outer sheaths) |
1000.0 |
|
5.10.1(ii) (Elongation percentage-After Ageing:Physical tests for insulation, inner & outer sheaths) |
1000.0 |
|
5.10.12 (Shrinkage test:Physical tests for insulation, inner & outer sheaths) |
500.0 |
|
5.11 (The period of burning after removal of flame: Flammability test) |
250.0 |
|
5.11 (Decomposed length of sample: Flammability test) |
250.0 |
|
5.12.1.1 (High voltage test :Signalling Cable) |
3000.0 |
|
5.14.1 (AC test:Water Immersion) |
3000.0 |
|
5.13.3 (Insulation Resistance test: Signalling Cable) |
2000.0 |
|
|
337 |
IS 14268 (2022) - Uncoated stress relieved low relaxation seven - Wire (Ply) strand for prestressed concrete - Specification (First Revision) |
Uncoated stress relieved low relaxation seven - Wire (Ply) strand for prestressed concrete - Specification (First Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
6.1 (Nominal Mass) |
1500.0 |
|
6.1 (Nominal Diameter ) |
1000.0 |
|
6.2.3 (Elongation) |
1000.0 |
|
6.2.2 (0.2% Proof Load) |
1000.0 |
|
6.2.2 (Breaking Strength) |
3000.0 |
|
4.2 (Length of lay for dia 15.2mm) |
500.0 |
|
4.2 (Centre wire shall have 1.5% greater in diameter than the surrounding wires - IS 14268: 2022.) |
1000.0 |
|
4.1 (Phosphorus, % by mass) |
600.0 |
|
4.1 (Sulphur, % by mass) |
600.0 |
|
4.5 (Workmanship and Finish) |
1000.0 |
|
6.1 (Nominal Area ) |
1000.0 |
|
4.1.2 (Chemical composition (Annexure for NABL parameters)) |
3500.0 |
|
4 (Chemical composition (Annexure for non-NABL parameters)) |
3000.0 |
|
Table 2 (Cl 6.2.1, Cl 6.2.2, Cl 6.3) (0.2% Proof Load, Breaking Strength of Strand, Total Elongation.) |
3000.0 |
|
Note 1 (Modulus of Elasticity, N/mm2) |
1000.0 |
|
|
338 |
RDSO IRS S 63/2014 : Part 0 : Sec Revision 4 (2014) - PVC Insulated,underground, unscreened cable for Railway Signalling |
PVC Insulated,underground, unscreened cable for Railway Signalling |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
339 |
IS 5410 (2013) - Cement paint - Specification (Second Revision) |
Cement paint - Specification (Second Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
4.8 ix (Recoating properties) |
1200.0 |
|
4.8 viii (Pot life of mixed paint) |
1200.0 |
|
4.8 vii (Water repellency) |
1200.0 |
|
4.8 vi (Resistance to dry rubbing) |
1200.0 |
|
4.8 v (Residue on sieve % by mass) |
1200.0 |
|
4.8iii (Colour) |
1200.0 |
|
4.8 ii (Finish) |
1200.0 |
|
4.8 i (Drying time Hard dry) |
1200.0 |
|
4.7 (Keeping properties) |
5000.0 |
|
Cl 4.4 (Lead Restriction) |
1200.0 |
|
Cl 4.1 (Composition) |
3500.0 |
|
|
340 |
Berger Customer Specification -NTH ER Paint 1 (2022) - Berger Customer Specification -NTH ER Paint 1 |
Berger Customer Specification -NTH ER Paint 1 |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Shelf life @ 30 °C
For 12 Months both liquid and powder) |
10000.0 |
|
|
341 |
Custom specification Paint coating - Custom specification Paint coating Fire retardant test as per customer requirement |
Custom specification Paint coating Fire retardant test as per customer requirement |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
Custom specification for paint coating (Surface flame spreading/fire retardant test for 0 -1 hour) |
3000.0 |
|
Custom specification for paint coating (surface flame spreading/fire retardant test for 1 - 2 hours) |
5000.0 |
|
|
342 |
IS 1964:2001 (2001) - Methods for Determination of Mass per Unit Lenght and Mass per Unit Area of Fabrics |
Methods for Determination of Mass per Unit Lenght and Mass per Unit Area of Fabrics |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
Method-A (Grammage of Fabric (GSM)) |
1000.0 |
|
|
343 |
IRS S 63 (2014) - PVC Insulated underground unsereened cable for railway signaling |
PVC Insulated underground unsereened cable for railway signaling |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
5.6 (Dimensions of Signaling Cable) |
500.0 |
|
5.7 (Conductor Resistance Signaling Cable) |
1000.0 |
|
5.8 (Tensile Strength of Armour) |
1000.0 |
|
5.1 (Thickness of inner sheath) |
500.0 |
|
5.1 (Thickness of Outer Sheath) |
500.0 |
|
5.8 (Dimension of Armour ( Signaling Cable)) |
500.0 |
|
5.8 (Percentage (%) elongation Armour tape(signaling Cable)) |
500.0 |
|
5.8 (Percentage (%) elongation Armour wire(signaling Cable)) |
500.0 |
|
5.8.6 (Resistivity on Armour ( Signaling Cable)) |
1000.0 |
|
5.1 (Tensile Strength of Insulation before ageing) |
500.0 |
|
5.1 (Tensile Strength of Insulation after ageing) |
1000.0 |
|
5.10.2 (Percentage (%)Shrinkage) |
1000.0 |
|
5.10.4 (Loss of Mass of Insulation and sheath) |
1000.0 |
|
5.10.4 (Loss of Mass of Insulation and sheath) |
1000.0 |
|
5.10.11 (Thermal stability of Insulation and Sheath) |
1000.0 |
|
5.11 (Period of burning after removal of flame) |
1000.0 |
|
5.11 (Decomposed length of sample) |
1000.0 |
|
5.12 (High Voltage in Air 4 kV AC) |
1000.0 |
|
5.13.3 (Insulation Resistance in Air ( Signaling Cable)) |
1000.0 |
|
5.14 (AC High Voltage Test 8 kV( Water Immersion)) |
1000.0 |
|
|
344 |
RDSO IRS S 63/2015 : Part 1 : Sec Revision 4 (2014) - PVC Insulated,underground, unscreened cable for Railway Signalling |
PVC Insulated,underground, unscreened cable for Railway Signalling |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
345 |
IS:3025 - Methods of sampling and test (Physical & chemical) for water and waste water |
Methods of sampling and test (Physical & chemical) for water and waste water |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
CL 8 (Part 44,58,11,16 &17 ) Essential Parameters (Please see Annexure) |
12000.0 |
|
6,Table1 ICP-OES Elements (Please see Annexure) |
7000.0 |
|
Cl 8 Essential Parameters as per NMCG Requirement (Cl 8 -Essential Parameters as per NMCG Requirement (Please see Annexure)) |
10000.0 |
|
APHA-23 edition Microbiological Parameters as per NMCG(Please see Annexure) (APHA-23 edition Microbiological Parameters as per NMCG(Please see Annexure)) |
2000.0 |
|
|
346 |
IS 13730(Part-9):1994,Reaffirmed 2005. (1994) - Specification for Particular Types of Winding Wires:Polyester Enamelled Round Aluminium Wire, Class 130 |
Specification for Particular Types of Winding Wires:Polyester Enamelled Round Aluminium Wire, Class 130 |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
4 (Dimensions) |
1000.0 |
|
5 (Electrical Resistance) |
2000.0 |
|
6 (Elongation) |
1500.0 |
|
9 (Heat Shock) |
500.0 |
|
4 (Dimensions) |
1000.0 |
|
13 (Break Down Voltage Test( At Room Temperature)) |
3000.0 |
|
8 (Mandrel winding test) |
1500.0 |
|
8 (Stretching test) |
1500.0 |
|
Tests (i)Measurement of diameter of conductor, ii)Measurement of increase in diameter,iii)Measurement of overall diameter,iv) Measurement of Elongation at break, v)Mandrel Winding Test,vi)Tensile Test on Conductor and vii)Weight check.) |
10000.0 |
|
|
347 |
MDTS : 094 Rev:01 (2002) - TECH SPECIFICATIONS FOR PAINTING SYSTEM FOR PASSENGER COACHES BUILT AT RCF,KAPURTHALA |
TECH SPECIFICATIONS FOR PAINTING SYSTEM FOR PASSENGER COACHES BUILT AT RCF,KAPURTHALA |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
Cl No. 3.1 FOR PRIMER (Epoxy metal primer) (Please see Annexure) |
25000.0 |
|
Cl No. 3.2 FOR Polyester based Kniffing Putty (Please see Annexure) |
8000.0 |
|
Cl No. 3.3 FOR Two component PUR PRIMER (Please see Annexure) |
25000.0 |
|
Cl No. 3.4 FOR Two component POLYURETHANE UNDERCOAT( PRIMING PAINT)PURER (Please see Annexure) |
12000.0 |
|
Cl No. 3.5 FOR Two component PUR POLYURETHANE BASED TOP COAT (Please see Annexure) |
35000.0 |
|
Cl No. 3.6 FOR Two component EpoxyHigh Build Paint ElastifiedR (Please see Annexure) |
40000.0 |
|
|
348 |
RDSO M&C/ PCN/ 100/ 2018 (2018) - Specification for Epoxy Cum Polyurethane Painting System (Two Pack) for the Exterior Painting of Railway Coaches |
Specification for Epoxy Cum Polyurethane Painting System (Two Pack) for the Exterior Painting of Railway Coaches |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
Chapter V/Cl. 3.2 (Humidity test.) |
11000.0 |
|
Chapter V/Cl. 3.2 (Accelerated Tests Resistance to water) |
1500.0 |
|
Chapter V/Cl. 3.2 (Accelerated Tests Resistance to solvents) |
1500.0 |
|
Chapter V/Cl. 3.2 (Accelerated Tests Resistance to oil) |
1500.0 |
|
Chapter V/Cl. 3.2 (Accelerated Tests Resistance to 20% caustic potash (weight by volume)) |
1500.0 |
|
Chapter V/Cl. 3.2 (Accelerated Tests (a) Resistance to 30% Sulphuric acid (weight by volume)) |
1500.0 |
|
Chapter V/Cl. 3.2 (Gloss at 60 degree angle of incidence) |
1200.0 |
|
Chapter V/Cl. 3.2 (Viscosity (Efflux time by Ford cup No. 4 ) at 27 degree C) |
1200.0 |
|
Chapter V/Cl. 3.2 (Fineness of grind) |
1200.0 |
|
Chapter V/Cl. 3.2 (Theoretical Spreading rate) |
1200.0 |
|
Chapter V/Cl. 3.2 (Pot life(After induction time)ii) 40 ± 2 Deg C) |
2000.0 |
|
Chapter V/Cl. 3.2 (Pot life (After induction time) at i) 27 ± 2 Deg C) |
1500.0 |
|
Chapter V/Cl. 3.2 (Mass in Kg/10 litres) |
1200.0 |
|
Chapter V/Cl. 3.2 (Keeping Properties for both the packs) |
5000.0 |
|
Chapter V/Cl. 3.2 (Flash Point (b) Component B) |
1200.0 |
|
Chapter V/Cl. 3.2 (Flash Point (a) Component A) |
1200.0 |
|
Chapter V/Cl. 3.2 (Flexibility & Adhesion (6.25mm mandrel)) |
1200.0 |
|
Chapter V/Cl. 3.2 (Scratch hardness (1.5 Kg LOAD)) |
1200.0 |
|
Chapter IV / Table I (Volume solids) |
2000.0 |
|
Chapter V/Cl. 3.2 (Dry film thickness/Per coat) |
1200.0 |
|
Chapter V/Cl. 3.2 (Colour) |
1200.0 |
|
Chapter V/Cl. 3.2 (Finish) |
1200.0 |
|
Chapter V/Cl. 3.2 (Consistency) |
1200.0 |
|
Chapter V/Cl. 3.2 (Drying time c) Hard Dry at 70 Deg C) |
1200.0 |
|
Chapter V/Cl. 3.2 (Drying time b) Hard Dry) |
1200.0 |
|
Chapter V/Cl. 3.2 (Drying time a) Surface Dry) |
1200.0 |
|
Chapter V/Cl. 3.2 (Identification of polyisocyanates) |
3000.0 |
|
|
349 |
IS 733 (1983 RA 2022) - SPECIFICATION FOR WROUGHT ALUMINIUM AND ALUMINIUM ALLOY BARS, RODS AND SECTIONS
(FOR GENERAL ENGINEERING PURPOSES) |
SPECIFICATION FOR WROUGHT ALUMINIUM AND ALUMINIUM ALLOY BARS, RODS AND SECTIONS
(FOR GENERAL ENGINEERING PURPOSES) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
5.1.1 a Chemical composition (Aluminium (as Al )content,% by mass) |
3000.0 |
|
5.1.1 b Chemical composition (Copper (as Cu)content,% by mass) |
500.0 |
|
5.1.1 C Chemical composition (Magnesium(as Mg ) content,% by mass) |
500.0 |
|
5.1.1 d Chemical composition (Silicon (as Si) content,% by mass) |
500.0 |
|
5.1.1 e Chemical composition (Iron (as Fe) content,% by mass) |
500.0 |
|
5.1.1 f Chemical composition (Manganese (as Mn) content,% by mass) |
500.0 |
|
5.1.1 g Chemical composition (Zinc (as Zn ) content,% by mass) |
500.0 |
|
5.1.1 h Chemical composition (Titanium (as Ti) content,% by mass) |
500.0 |
|
5.1.1 i Chemical composition (Chromium (as Cr) content,% by mass) |
500.0 |
|
5.1.1 j Chemical composition (Vanadium (as V) content,% by mass) |
500.0 |
|
7 (Dimension) |
1000.0 |
|
9.1 (Tensile Strenth) |
2000.0 |
|
9.1 (0.2% Proof Stress) |
1000.0 |
|
9.1 (Elongation) |
1000.0 |
|
0 (Anodic Coating) |
2000.0 |
|
5 (Chemical composition, % by mass) |
6000.0 |
|
0 (Weight, kg) |
1000.0 |
|
|
350 |
RDSO Drg.No. SK-94254 Alt-3 /IS:1030 - CARBON STEEL CASTINGS FOR GENERAL ENGINEERING PURPOSES |
CARBON STEEL CASTINGS FOR GENERAL ENGINEERING PURPOSES |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
Cl no. 8.1 Table 1 (Carbon) |
1200.0 |
|
|
351 |
IS 2039(Part1 to 3) (1991) - Steel Tubes for Bicycle and Cycle Rickshaws |
Steel Tubes for Bicycle and Cycle Rickshaws |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
9 (Dimensions) |
20000.0 |
|
|
352 |
JIS K 5659:2018 (2018) - LONG DURABLE PAINTS FOR STEEL STRUCTURES |
LONG DURABLE PAINTS FOR STEEL STRUCTURES |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
Clause 5 Table 2 Top Coat Type A (Please see Annexure) |
40000.0 |
|
Clause 5 Table 2 Intermediate CoatType A (Please see Annexure) |
40000.0 |
|
Clause 5 Table 2 Top Coat Type B (Please see Annexure) |
1.0 |
|
Clause 5 Table 2 Type B Intermediate Coat (Please see Annexure) |
1.0 |
|
5 Table 2 LONG DURABLE PAINTS FOR STEEL STRUCTURES ( ZINC RICH PRIMER) TYPE A (Please see Annexure) |
55000.0 |
|
5 Table 2 (LONG DURABLE PAINTS FOR STEEL STRUCTURES( Intermediate) TYPE A (Please see Annexure) |
45000.0 |
|
5 Table 2 LONG DURABLE PAINTS FOR STEEL STRUCTURES (Undercoat) TYPE A (Please see Annexure) |
20000.0 |
|
5 Table 2 LONG DURABLE PAINTS FOR STEEL STRUCTURES( FINISH) TYPE A (Please see Annexure) |
50000.0 |
|
|
353 |
IS 894 (2023) - SPECIFICATION FOR HANDLOOM WOOL BLANKETS BRICK RED |
SPECIFICATION FOR HANDLOOM WOOL BLANKETS BRICK RED |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
Table 2 (Fibre Composition) |
2000.0 |
|
Table-1 (Ends per inch) |
1000.0 |
|
Table-1 (Picks per inch) |
1000.0 |
|
Table-1 (Breaking Load, kgs) |
2000.0 |
|
Table-1 (Weight per square meter (GSM)) |
1000.0 |
|
Table-1 (Type of Weaves) |
1000.0 |
|
Firm's Requirement (Weight of Blanket, g) |
1000.0 |
|
Firm's Requirement (Satin Piping Stitching/cms.) |
1000.0 |
|
|
354 |
IS 16103 (Part-2): 2012 (2012) - LED Modules for General Lighting |
LED Modules for General Lighting |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
Clause 10 (Measurement of power Input) |
7500.0 |
|
|
355 |
NS/NR/RPPT (2022) - Test for Writing/Notice/Display Boards, Low Dust Chalk, Duster and Acrylic Desk etc |
Test for Writing/Notice/Display Boards, Low Dust Chalk, Duster and Acrylic Desk etc |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
NA (Galvanized Steel Sheet Thickness) |
1000.0 |
|
NA (Zinc Coating (in micron)) |
2000.0 |
|
NA (Length) |
500.0 |
|
NA (Dimension) |
100.0 |
|
NA (Colour) |
1000.0 |
|
NA (Purpose (Laminated Sheet Green)) |
1000.0 |
|
NA (Purpose of Chalk for Writing) |
1000.0 |
|
NA (Application /Usage) |
1000.0 |
|
NA (Purpose (Laminated Sheet White)) |
1000.0 |
|
NA (Coating Thickness Top Side (mm)) |
1000.0 |
|
NA (Coating Thickness Bottom Side (mm)) |
1000.0 |
|
NA (Type of Duster (Magnetic or Non-magnetic)) |
1000.0 |
|
NA (Zinc Coating as per IS 277(g/sq.meter)) |
2000.0 |
|
NA (Bulk Density) |
1000.0 |
|
NA (Density) |
1000.0 |
|
NA (Gloss of Sheet Top Side @ 60deg) |
1000.0 |
|
|
356 |
AASHTO T 166 (for BC & DBM cores) - AASHTO T 166-Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Saturated Surface-Dry Specimens |
AASHTO T 166-Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Saturated Surface-Dry Specimens |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Test for bulk specific gravity (Gmb) of DBM (on the lines of AASHTO T 166)) |
2500.0 |
|
2 (Test for bulk specific gravity (Gmb) of BC (on the lines of AASHTO T 166)) |
2500.0 |
|
|
357 |
IS 383 for coarse aggregate (2016) - Coarse and fine aggregate for concrete |
Coarse and fine aggregate for concrete |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
14 (Test for Alkali aggregate reaction-(IS 2386(7):1963):Chemical method) |
3000.0 |
|
5.7 TABLE 3 (TOTAL ALKALI CONTENT as Na2O) |
1200.0 |
|
5.7 TABLE 3 (TOTAL SULPHATE CONTENT as SO3) |
1200.0 |
|
5.7 TABLE 3 (ACID SOLUBLE CHLORIDE CONTENT) |
1200.0 |
|
12 (Test for Deleterious Materials(IS 2386(Part 2):1963)) |
2000.0 |
|
|
358 |
IS 1199 (4) - Methods of sampling and analysis of concrete |
Methods of sampling and analysis of concrete |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
10 (Ratio of Cement :Aggregates) |
5000.0 |
|
|
359 |
IS 3989 (2009) - Centrifugally Cast (Spun) Iron Spigot and Socket Soil, Waste and Ventilating Pipes, Fittings and Accessories |
Centrifugally Cast (Spun) Iron Spigot and Socket Soil, Waste and Ventilating Pipes, Fittings and Accessories |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
3.3 (Brinell Hardness (HBW)) |
2000.0 |
|
4 (Hammer Test) |
1000.0 |
|
5 (Hydrostatic Test) |
5000.0 |
|
6.3 (Thickness and OD of the pipe) |
1000.0 |
|
6.3 (Mass of the Pipe) |
1000.0 |
|
0 (Visual Check) |
1000.0 |
|
0 (Ovality) |
1000.0 |
|
0 (Length) |
1000.0 |
|
0 (Marking) |
500.0 |
|
0 (Class of Pipe) |
500.0 |
|
0 (Tensile Strength) |
2000.0 |
|
0 (Ring Test) |
2000.0 |
|
0 (Thickness) |
1000.0 |
|
8 (Coating Test) |
2000.0 |
|
|
360 |
1239 (2011) - Steel Tubes, Tubulars and other Steel Fittings, PART 2 STEEL PIPE FITTINGS |
Steel Tubes, Tubulars and other Steel Fittings, PART 2 STEEL PIPE FITTINGS |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
9 (Dimension,mm.) |
1000.0 |
|
13.1.1 (Mass of Zinc Coating) |
2000.0 |
|
13.1.2 (Uniformity of Zinc Coating) |
500.0 |
|
14 (Workmanship, Visual) |
500.0 |
|
3.1 (Sulphur (% by mass)) |
700.0 |
|
3.1 (Phosphorous (% by mass)) |
700.0 |
|
|