| 331 |
WD-01-HLS-94(Rev-03) (Amdt. No.4 of Oct 2020 Para No: 2.4) - Metallurgical Test of Spring Steel |
Metallurgical Test of Spring Steel |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| - (Chemical Composition As per IS 3195) |
4500.0 |
|
| - (Metallurgical Test) |
23500.0 |
|
|
| 332 |
IS 16172 (2023) - Reinforcement couplers for mechanical splices of bars in concrete - Specification |
Reinforcement couplers for mechanical splices of bars in concrete - Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 9.2 (Tensile Strength as per IS 1608(Part 1):2022) |
1500.0 |
|
| 9.2 (Percentage Elongation as per IS 1608(Part 1):2022) |
1500.0 |
|
| 9.2 (Visual Observation for Nature & Location of failure of spliced specimen (With Coupling).) |
1000.0 |
|
| 8 (Chemical composition, % by mass) |
3000.0 |
|
|
| 333 |
NTH/NR/RPPT/Polycarbonate Sheet - Customized specification for Polycarbonate Sheet |
Customized specification for Polycarbonate Sheet |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Firm's Requirement (Length) |
500.0 |
|
| Firm's Requirement (Width) |
500.0 |
|
| Firm's Requirement (Thickness) |
1000.0 |
|
| Firm's Requirement (Melt Flow Index) |
2000.0 |
|
| Firm's Requirement (Luminous Transmittance) |
2000.0 |
|
| Firm's Requirement (Density) |
1000.0 |
|
| Firm's Requirement (Tensile Strength at Yield) |
1000.0 |
|
| Firm's Requirement (Tensile Modulus) |
1000.0 |
|
| Firm's Requirement (Flexural Strength) |
2000.0 |
|
| Firm's Requirement (UV Layer (Top & Bottom)) |
2000.0 |
|
|
| 334 |
NTH/NR/RPPT/Miscellaneous/01 (2023) - Testing of Miscellaneous Items |
Testing of Miscellaneous Items |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Firm's Requirement (Result of Tests) |
5000.0 |
|
| Firm's Requirement (Results of Test (Mechanical)) |
20000.0 |
|
| Firm's Requirement (Results of Test (Electrical)) |
10000.0 |
|
| Firm's Requirement (Results of Test (Chemical)) |
5000.0 |
|
| Firm's Requirement (Density) |
2000.0 |
|
| Firm's Requirement (Thickness) |
1000.0 |
|
| Firm's Requirement (Dimensions) |
5000.0 |
|
| Firm's Requirement (Weight) |
1000.0 |
|
|
| 335 |
IS 9755 (2021) - Textiles - High Density Polyethylene (HDPE) / Polypropylene (pp) Woven Sacks for Packing Fertilizers |
Textiles - High Density Polyethylene (HDPE) / Polypropylene (pp) Woven Sacks for Packing Fertilizers |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5.2 (Visual Inspection Test) |
500.0 |
|
| Table-1 (Dimensions) |
1000.0 |
|
| Table-1 (Ends/dm) |
500.0 |
|
| Table-1 (Picks/dm) |
500.0 |
|
| Table-1 (Mass of Fabric) |
1000.0 |
|
| Table-1 (Mass of Sack) |
500.0 |
|
| Table-1 (Breaking Strength (Lengthwise)) |
750.0 |
|
| Table-1 (Breaking Strength (Widthwise)) |
750.0 |
|
| Table-1 (Breaking Strength (Widthwise) of Laminated joint (for laminated sacks)) |
1000.0 |
|
| Table-1 (Breaking Strength of bottom seam) |
1000.0 |
|
| Table-1 (Elongation@break of fabric (Lengthwise)) |
750.0 |
|
| Table-1 (Elongation@break of fabric (Widthwise)) |
750.0 |
|
| Table-1 (Ash Content) |
2000.0 |
|
|
| 336 |
IS 7834 (Part-1) (1987) - INJECTION MOULDED PVC SOCKET FITTINGS WITH SOLVENT CEMENT JOINTS FOR WATER SUPPLIE |
INJECTION MOULDED PVC SOCKET FITTINGS WITH SOLVENT CEMENT JOINTS FOR WATER SUPPLIE |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 3 (Size of Fitting) |
500.0 |
|
| 4 (Minimum Thickness) |
500.0 |
|
| 5.1 (Socket Length) |
500.0 |
|
| 5.1.2 (Minimum ID at Mid-Point) |
500.0 |
|
| 5.1.2 (Maximum ID at Mid-Point) |
500.0 |
|
| 6.1 (Stress Relief Test) |
5000.0 |
|
| 6.2 (Opacity (%)) |
1000.0 |
|
| 6.4 (Short Term Hydraulic Test) |
5000.0 |
|
| 6.3 (Effect on Water) |
2000.0 |
|
|
| 337 |
NTH/NR/Cust Spec/T-Shirt/2023/01 - NTH/NR/Cust Spec/T-Shirt/2023/01 |
NTH/NR/Cust Spec/T-Shirt/2023/01 |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1.0 (Mass) |
1000.0 |
|
| 2.0 (Fiber Composition) |
3000.0 |
|
|
| 338 |
IS 15852 (2009) - Textiles – Polyester blended woven shirting for uniforms |
Textiles – Polyester blended woven shirting for uniforms |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 4 (Mass) |
2000.0 |
|
| 4 (Fibres composition) |
2000.0 |
|
|
| 339 |
Custom-Mech-NR - Custom-Mech-NR |
Custom-Mech-NR |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| NA (Proof Load Test) |
3000.0 |
|
| NA (Magnetic Particle Test) |
4000.0 |
|
| NA (Ultrasonic Test) |
4000.0 |
|
| NA (Visual Inspection Test) |
1000.0 |
|
| NA (Chemical Composition) |
5000.0 |
|
| NA (Hydrostatic Test) |
5000.0 |
|
| NA (Pneumatic Test) |
5000.0 |
|
| NA (Tensile Test) |
3000.0 |
|
| NA (Test of Polymer) |
8000.0 |
|
| - (Radiography Test) |
2000.0 |
|
| - (Coating Test) |
8000.0 |
|
|
| 340 |
IRSM 28 (2017) - Indian Railway Standard Specification For Classification, Testing And Acceptance Criteria Of Manual Metal Arc Welding Electrodes And Gas Welding Rods |
Indian Railway Standard Specification For Classification, Testing And Acceptance Criteria Of Manual Metal Arc Welding Electrodes And Gas Welding Rods |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| As Per IRSM 28:2017 (Testing of Stainless Steel Flux covered Electrode) |
16500.0 |
|
| NA (Weld Assembly Preparation) |
5000.0 |
|
| 6.2.2 (Table-5) (Transverse Bend Test) |
3000.0 |
|
|
| 341 |
NTH/NR/Cust Spec/UPVC Profile/2023/01 - Customer Specification for UPVC Profiles and Sections |
Customer Specification for UPVC Profiles and Sections |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Vicat Softening Temperature) |
1500.0 |
|
| 2 (Heat Reversion Test) |
2000.0 |
|
| 3 (Titanium Di-oxide) |
1500.0 |
|
| 4 (Calcium Carbonate) |
1500.0 |
|
|
| 342 |
Cust Spfn UPVC Windows/Doors Profile - UPVC Windows/Doors Profile |
UPVC Windows/Doors Profile |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5 (Vicat Softening Temperature at 5kg load) |
1500.0 |
|
| 18 (Heat Reversion Test) |
2000.0 |
|
| 19 (Titanium Di-oxide) |
2000.0 |
|
| 20 (Calcium Carbonate) |
2000.0 |
|
|
| 343 |
1537 - Specification for Vertically cast iron pressure pipes for water, gas and sewage. |
Specification for Vertically cast iron pressure pipes for water, gas and sewage. |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 4.1 (Tensile Strength) |
3000.0 |
|
| 4.2 (Brinell Hardness Test) |
2000.0 |
|
| 6 (Hydrostatic Test) |
5000.0 |
|
| 7 (Dimensions) |
1000.0 |
|
| 9 (Mass) |
1000.0 |
|
| 10.4 (Coating Test) |
1000.0 |
|
|
| 344 |
1124-1974 RA 2003 (1974 RA 2003) - Method of test for Water absorption, Apparent Specific Gravity and Porosity of Natural Building Stone |
Method of test for Water absorption, Apparent Specific Gravity and Porosity of Natural Building Stone |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5 of 1124 (Water Absorption) |
1000.0 |
|
| 4.2 (Specific Gravity) |
500.0 |
|
|
| 345 |
IS 12894 (2002) - Pulverized fuel ash - Lime bricks - Specification |
Pulverized fuel ash - Lime bricks - Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5 (Dimensions) |
500.0 |
|
| 7.3 (Efforescence) |
1000.0 |
|
| 7.1 (Crushing Strength) |
2000.0 |
|
| 7.4 (Water Absorption) |
1000.0 |
|
| 3 (General quality) |
500.0 |
|
|
| 346 |
14846 - SLUICE VALVE FOR WATER WORKS PURPOSES
(50 TO 1 200 mm SIZE) |
SLUICE VALVE FOR WATER WORKS PURPOSES
(50 TO 1 200 mm SIZE) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 2 (Dimensions) |
2500.0 |
|
| 10.1.1 (Hydraulic Pressure test of Body) |
2500.0 |
|
| 10.1.2 (Hydraulic Pressure test of Seat in X side) |
2500.0 |
|
| 10.1.3 (Hydraulic Pressure test of Seat in Y side) |
2500.0 |
|
| 6 (Materials) |
2000.0 |
|
|
| 347 |
Customized Specification for the ILC of Paper - Customized Specification for the ILC of Paper |
Customized Specification for the ILC of Paper |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Clause 13.2.2 (IS 1060 (Part-1)) |
- |
|
| Clause 6 (IS 1060 (Part-1)) |
500.0 |
|
| Clause 16 (Is 1060 (Part-1)) |
- |
|
| Clause 7 (IS 1060 (Part-1)) |
- |
|
| 12.7 (IS 1060 (Part-1)) |
- |
|
| 12.7 (IS 1060 (Par-1)) |
- |
|
| 12.3 (IS 1060 (Part-1)) |
- |
|
| 12.3 (IS 1060(Part-1)) |
- |
|
| Clause 13 (IS 1060 (Part-2)) |
- |
|
| 12.6 (IS 1060 (Part-1)) |
- |
|
| Clause 3 (IS 9894) |
- |
|
| - (IS 9894) |
- |
|
| Clause 8 (IS 1060 (Part-3)) |
- |
|
| Clause 8 (IS 1060 (Part-1)) |
- |
|
| 12.5 (IS 1060 (Part-1)) |
- |
|
|
| 348 |
IS 383 (2016) & CPWD Vol. I Specifications - Specification for Coarse & Fine Aggregate |
Specification for Coarse & Fine Aggregate |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6.3 (Sieve Analysis) |
2000.0 |
|
| MoRTH Specs (Fineness Modulus) |
500.0 |
|
| 5.2.1 (Deleterious Material) |
2000.0 |
|
| CPWD Specs (Silt Content) |
1000.0 |
|
| 5.5 (Soundness) |
2000.0 |
|
| 2386 Part 3 (Bulk Density) |
1000.0 |
|
| 2386 Part 3 (Specific Gravity) |
500.0 |
|
| 2386 Part 3 (Water Absorption) |
1000.0 |
|
| 2.1 (Aggregate Crushing Value) |
1500.0 |
|
| 3 of 2386-IV (Fine Value) |
1500.0 |
|
| 4 of 2386-IV (Aggregate Impact Value) |
1500.0 |
|
| 5 of 2386-IV (Aggregate Abrasion Value) |
1500.0 |
|
| 4 of 2386 Part 1 (Flakiness Index, %) |
1500.0 |
|
| 5 of IS 2386-I (Elongation Index, %) |
1500.0 |
|
| 4, 5 of IS 2386 (Combined Flakiness & Elongation Indices) |
3000.0 |
|
| 4.2 (Alkali Aggregate reactivity) |
3000.0 |
|
| 2386 Part 3 (Moisture Content) |
1000.0 |
|
| 4.0 Bulking of Sand (Bulking of Sand) |
1000.0 |
|
| Organic Impurities (Organic Impurities) |
1000.0 |
|
|
| 349 |
IS 7310 : Part 1 (1974) - Approval test for welders to approve welding procedures (plate & electrodes not supplied by NTH) |
Approval test for welders to approve welding procedures (plate & electrodes not supplied by NTH) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 8.2.1a) (Penetrant Testing) |
1000.0 |
|
| 8.3.1 (Macro-examination Test) |
1000.0 |
|
| 8.3.1 (Fillet weld fracture test) |
3000.0 |
|
| WELDER APPROVAL TEST (WELDER APPROVAL TEST( Butt Weld Joint)) |
7000.0 |
|
| WELDER APPROVAL TEST (WELDER APPROVAL TEST (Fillet Weld Joint)) |
7000.0 |
|
|
| 350 |
IS 9763:2000 (2000) - PLASTICS BIB TAPS, PILLAR TAPS, ANGLE VALVES AND STOP VALVES FOR HOT AND COLD WATER SERVICES |
PLASTICS BIB TAPS, PILLAR TAPS, ANGLE VALVES AND STOP VALVES FOR HOT AND COLD WATER SERVICES |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Table-1 (Material Identification) |
2000.0 |
|
| 5.1 (Nominal Size) |
1000.0 |
|
| 6 (Dimensions) |
2000.0 |
|
| 8.4 (Minimum Thickness) |
1000.0 |
|
| 8 (Construction, Workmanship and Finish) |
1000.0 |
|
| 9.1 (Resistance to Residual Chlorine in Water) |
1000.0 |
|
| 9.3 (Thermal Shock Test) |
2000.0 |
|
| 9.2 (Drip Proofness Test) |
1000.0 |
|
|
| 351 |
IS 16014 (2024) - Mechanically woven, double - Twisted, hexagonal wire mesh gabions, revet mattresses, rock fall netting and other products for civil engineering purposes (Galvanized Steel Wire Or Galvanized Steel Wire With Polymer Coating) - Specification (First Revision) |
Mechanically woven, double - Twisted, hexagonal wire mesh gabions, revet mattresses, rock fall netting and other products for civil engineering purposes (Galvanized Steel Wire Or Galvanized Steel Wire With Polymer Coating) - Specification (First Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6.1 (Tensile Strength of Mesh Wire(Steel)) |
2000.0 |
|
| 7.1 (Mass of Zinc/Zinc Alloy Coating of Mesh Wire) |
2000.0 |
|
| 7.2 (Specific Gravity of Polymer Coating Material of Mesh Wire) |
1000.0 |
|
| 7.2 (Tensile Strength of Polymer Coating Material of Mesh Wire) |
1000.0 |
|
| 6.1 (Elongation of Mesh Wire) |
1000.0 |
|
| 7.2 (Hardness of Polymer Coating Material of Mesh Wire) |
1000.0 |
|
| 8 (Diameter of Mesh Wire without Polymer Coating) |
1000.0 |
|
| 8 (Thickness of Polymer Coating of Mesh Wire) |
1000.0 |
|
| 8 (Mesh Size) |
1000.0 |
|
| 8 (Diameter of Edge/Selvedge Wire without Polymer Coating) |
1000.0 |
|
| 8 (Diameter of Lacing Wire without Polymer Coating) |
500.0 |
|
| 8 (Size of Gabion Box/ Revet Mattress/ Reinforced Soil Structure (L x W x H)) |
1000.0 |
|
| 8 (Diameter of Edge/Selvedge Wire with Polymer Coating) |
1000.0 |
|
| 6.1 (Tensile Strength of Edge/Selvedge Wire (steel)) |
2000.0 |
|
| 6.1 (Tensile Strength of Lacing Wire(steel)) |
2000.0 |
|
| 6.1 (Elongation of Edge/Selvedge Wire) |
1000.0 |
|
| 6.1 (Elongation of Lacing Wire) |
1000.0 |
|
| 7.1 (Mass of Zinc/Zinc Alloy Coating of Edge/Selvedge Wire) |
2000.0 |
|
| 7.1 (Mass of Zinc/Zinc Alloy Coating of Lacing Wire) |
2000.0 |
|
|
| 352 |
MORTH/ASTM - Mix Macadam |
Mix Macadam |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 406.2.1.1 (Water absorption) |
1000.0 |
|
| 406.2.1.1 Table 400.12.1 (Aggregate Impact value) |
1500.0 |
|
| 406.2.1.1 Table 400.12.2 (Combined Flakiness and Elongation Indices (Total)) |
3000.0 |
|
| 406.2.1.2 Table 400.13 (Grading Requirements of Aggregates for Wet Mix Macadam) |
5000.0 |
|
| 406.2.1.2 (Liquid Limit) |
1000.0 |
|
| 406.2.1.2 (Plastic Limit) |
1000.0 |
|
| 406.2.1.2 (Plasticity Index (PI)) |
1000.0 |
|
| 406.2.1.1 Table 400.12.1 (Los Angeles Abrasion value) |
1500.0 |
|
| 406.2.1.1 (Soundness) |
2000.0 |
|
|
| 353 |
MORTH-5th Revision 2013 Sub Base, Bases (Non Bituminous) - Specifications for Road and Bridge Works |
Specifications for Road and Bridge Works |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Section 400 of MoRTH GSB/WBM/WMM/Screening/CRM etc. (Table 400-1/9/10/13/14 etc.). (Grading(as per Table 400 section of Morth 5th revision)) |
5000.0 |
|
| 401.2.2 (Water absorption) |
1000.0 |
|
| Section 400 of MoRTH GSB/WBM/WMM/CRM etc. (Table 400-2/8/1215 etc.). (Aggregate Impact value) |
1500.0 |
|
| Section 400 of MoRTH GSB/CRM etc. (Table 400-2/15 etc.). (Liquid limit) |
1000.0 |
|
| Section 400 of MoRTH GSB/CRM etc. (Table 400-2/15 etc.). (Plasticity Index) |
2000.0 |
|
| 401.2.2 Table 400.2 (CBR) |
6000.0 |
|
| Section 400 of MoRTH WBM/WMM/CRM (400-8/12/15 etc.) (Combined Flakiness & Elongation Indices) |
3000.0 |
|
| Section 400 of MoRTH for IS 2720-Part 8 (MDD & OMC for Base, Sub Base (Proctor Test-Heavy Compaction)) |
5000.0 |
|
|
| 354 |
1121 (Stone) (1974) - Method of Test of Natural Building Stone |
Method of Test of Natural Building Stone |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5 & 6 (Water Absorption [IS 1124 : 1974], %) |
1000.0 |
|
| 5 & 6 (Specific Gravity [ IS 1124 : 1974]) |
1000.0 |
|
|
| 355 |
IS 1130 (1969) - Marble (blocks, Slabs And Tiles) |
Marble (blocks, Slabs And Tiles) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 7 (Specific Gravity) |
1000.0 |
|
| 7 (Moisture Absorption (as per 1124), %) |
1000.0 |
|
| 7 (Hardness) |
2000.0 |
|
|
| 356 |
5561 - 1970 (1970) - SPECIFICATION FOR ELECTRIC POWER CONNECTORS |
SPECIFICATION FOR ELECTRIC POWER CONNECTORS |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 12 (As per Specification) |
1.0 |
|
|
| 357 |
IS 12894:2002 (On the lines, comparative tests for Fly ash bricks) (2002) - Pulverized Fuel ash lime bricks-Specification |
Pulverized Fuel ash lime bricks-Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Comparative tests for fly ash bricks (on the lines of IS 12894:2002)) |
14000.0 |
|
|
| 358 |
IS 5986 (2017) - Hot Rolled Steel Flat Products for Structural Forming and Flanging Purposes |
Hot Rolled Steel Flat Products for Structural Forming and Flanging Purposes |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 7 (Carbon) |
500.0 |
|
| 7 (Sulphur) |
500.0 |
|
| 7 (Phosphorus) |
500.0 |
|
| 13 (Freedom from defect) |
1000.0 |
|
| 8 (Tensile Strength) |
2000.0 |
|
| 8 (Yield Stress) |
1000.0 |
|
| 8 (Percentage Elongation) |
1000.0 |
|
| 0 (Dimensions & Weight) |
2000.0 |
|
| 1 (1) |
- |
|
| 7 (Silicon) |
500.0 |
|
| 0 (Dimensions & Weight) |
2000.0 |
|
| 7 (Carbon Equivalent) |
1000.0 |
|
| 7 (Manganese) |
500.0 |
|
| 9.2.2 (Bend Test) |
1500.0 |
|
| 0 (Mass of Zinc Coating as per IS 4759) |
2000.0 |
|
| 0 (Uniformity of Coating as per Is 2633) |
1000.0 |
|
|
| 359 |
NTH/ER/CHEM/CUST-02 BS 476 ASTM E 119 (22) - AS PER CUSTOMER REQUIRMENTS
FIRE RESISTANCE TEST |
AS PER CUSTOMER REQUIRMENTS
FIRE RESISTANCE TEST |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Fire Resistance Test:
1.Stability) |
2000.0 |
|
| 2 (Fire Resistance Test:
2.Integrity) |
2000.0 |
|
| 3 (Fire Resistance Test:3. Insulation) |
1000.0 |
|
| 4 (Fire Resistance Test:4 Fire resistance Properties) |
2000.0 |
|
| 5 (Fire Resistance Test:5 Self –Extinguished Properties) |
2000.0 |
|
| 6 (Fire Resistance Test: 6 Peel Off after 120 /240 min Fire test) |
1000.0 |
|
|
| 360 |
IS 4658:1988/Customer requirements (1988) - Cover Paper/Coated paper/Art paper |
Cover Paper/Coated paper/Art paper |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| - (Cl. 3.4 of IS 4658:1988) |
1000.0 |
|
| - (Cl. 12.5 of IS 1060 (Part-1)) |
1500.0 |
|
| - (Appendix B of IS 4658:1988) |
2000.0 |
|
| - (Appendix C of IS 4658:1988) |
1500.0 |
|
| - (Cl. 13 of IS 1060 (Part-2)) |
2000.0 |
|
| - (Cl. 15 of IS 1060 (Part-1)) |
1500.0 |
|
|