| 2911 |
National Test House (NR), Ghaziabad
| CUSTOMER SPEC : EIL SOW & SPEC Vol 2 (Civil) P-7 - Cold Galvanizing product |
Cold Galvanizing product |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Clause 6.0 Table-2 (Please see Annexure) |
40000.0 |
|
|
| 2912 |
National Test House (NR), Ghaziabad
| CUSTOMER SPEC : EIL SOW & SPEC Vol 2 (Civil) P-4 - Etch Primer/Wash Primer |
Etch Primer/Wash Primer |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Clause 6.0 Table-2 (Please see Annexure) |
40000.0 |
|
|
| 2913 |
National Test House (NR), Ghaziabad
| CUSTOMER SPEC : EIL SOW & SPEC Vol 2 (Civil)F-2 - Acrylic Polyurethane Finish Paint |
Acrylic Polyurethane Finish Paint |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Clause 6.0 Table-2 (Please see Annexure) |
40000.0 |
|
|
| 2914 |
National Test House (NR), Ghaziabad
| CUSTOMER SPEC : EIL SOW & SPEC Vol 2 (Civil) F-3 - Chlorinated Rubber Based Finish paint |
Chlorinated Rubber Based Finish paint |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Clause 6.0 Table-2 (Please see Annexure) |
40000.0 |
|
|
| 2915 |
National Test House (NR), Ghaziabad
| CUSTOMER SPEC : EIL SOW & SPEC Vol 2 (Civil) F-6A/B - Epoxy-High Build Coating |
Epoxy-High Build Coating |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Clause 6.0 Table-2 (Please see Annexure) |
40000.0 |
|
|
| 2916 |
National Test House (NR), Ghaziabad
| CUSTOMER SPEC : EIL SOW & SPEC Vol 2 (Civil) F-6C - Solvent less epoxy coating |
Solvent less epoxy coating |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Clause 6.0 Table-2 (Please see Annexure) |
40000.0 |
|
|
| 2917 |
National Test House (NR), Ghaziabad
| CUSTOMER SPEC : EIL SOW & SPEC Vol 2 (Civil) P-6 - Epoxy Zinc Phosphate Primer |
Epoxy Zinc Phosphate Primer |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Clause 6.0 Table-2 (Please see Annexure) |
40000.0 |
|
|
| 2918 |
National Test House (ER), Kolkata
| IS 1664 (2002) - Mineral mixtures for supplementing cattle feeds - Specification (Fourth Revision) |
Mineral mixtures for supplementing cattle feeds - Specification (Fourth Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6.3 (Moisture) |
500.0 |
|
| 6.3 (Salt as NaCl) |
500.0 |
|
| 6.3 (Calcium (as Ca)) |
500.0 |
|
| 6.3 (Phosphorus) |
500.0 |
|
| 6.3 (Iron Content) |
500.0 |
|
| 6.3 (Iodine (as KI)) |
1000.0 |
|
| 6.3 (Manganese (as Mn)) |
500.0 |
|
| 6.3 (Cobalt (as Co)) |
1000.0 |
|
| 6.3 (Fluourine (as F)) |
1000.0 |
|
| 6.3 (Zinc (as Zn)) |
500.0 |
|
| 6.3 (Magnesium) |
500.0 |
|
| 6.3 (Sulphur) |
1000.0 |
|
| 6.3 (Acid Insoluble Ash) |
500.0 |
|
| 6.3 (Lead (as Pb)) |
1000.0 |
|
| 6.3 (Arsenic (as As2O3)) |
1000.0 |
|
| 6.3 (Total ash in moisture free sample) |
500.0 |
|
| 6.3 (Presence of proteinous/organic impurities) |
500.0 |
|
| 6.3 (Acid Insoluble Ash) |
500.0 |
|
|
| 2919 |
National Test House (ER), Kolkata
| IS 2553(1):2018 & IS 17004:2018 (2018) - SAFETY GLASS — SPECIFICATION
PART 1 ARCHITECTURAL, BUILDING AND GENERAL USES
& TESTING METHODS FOR PROCESSED GLASS |
SAFETY GLASS — SPECIFICATION
PART 1 ARCHITECTURAL, BUILDING AND GENERAL USES
& TESTING METHODS FOR PROCESSED GLASS |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5.3.1 (Test for Thickness (IS 17004 : 2018)) |
2000.0 |
|
|
| 2920 |
National Test House (NWR), Jaipur
| IS 209 (1992) - Zinc ingot - Specification (Fourth Revision) |
Zinc ingot - Specification (Fourth Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6.1 (Zinc) |
2000.0 |
|
|
| 2921 |
National Test House (SR), Chennai
| IS : 7098(Part 1)1988, Reaff 2020 Amdt-5 (1988) - Specification for Cross linked Polyethylene Insulated PVC Sheathed Cable
Part 1 for working voltage upto and Including 1100Volt |
Specification for Cross linked Polyethylene Insulated PVC Sheathed Cable
Part 1 for working voltage upto and Including 1100Volt |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 15.1 (Type tests ( XLPE insulated, PVC sheathed, Single Core)) |
20000.0 |
|
| 15.1 (Type tests (XLPE insulated, PVC sheathed, Two Core )) |
22000.0 |
|
| 15.1 (Type tests ( XLPE insulated, PVC sheathed, Three Core )) |
24000.0 |
|
| 15.1 (Type tests (XLPE insulated, PVC sheathed, Three and Half or four core)) |
26000.0 |
|
| 15.2 (Acceptance tests ( XLPE insulated, PVC sheathed, Single Core )) |
12000.0 |
|
| 15.2 (Acceptance tests ( XLPE insulated, PVC sheathed, Two Core )) |
14000.0 |
|
| 15.2 (Acceptance tests ( XLPE insulated, PVC sheathed, Three Core )) |
16000.0 |
|
| 15.2 (Acceptance tests ( XLPE insulated, PVC sheathed, Three and Half or four core )) |
18000.0 |
|
| 15.1 (Type tests ( Single Core FRLS Cable)) |
35000.0 |
|
| 15.1 (Type tests ( Two core FRLS Cable )) |
40000.0 |
|
| 15.1 (Type tests (Three core FRLS Cable)) |
45000.0 |
|
| 15.1 (Type tests ( Three and Half or four core FRLS Cable)) |
50000.0 |
|
| 15.2 (Acceptance tests (Single core FRLS Cable)) |
12000.0 |
|
| 15.2 (Acceptance tests ( Two core FRLS Cable )) |
17000.0 |
|
| 15.2 (Acceptance tests ( Three coreFRLS Cable )) |
22000.0 |
|
| 15.2 (Acceptance tests ( Three and Half or four core FRLS Cable )) |
27000.0 |
|
| 15.1.1 & 15.2.1 (FRLSH for all type of samples) |
20000.0 |
|
| 15.1.a.ii (Tensile Test (for Aluminum) Conductor read with IS : 8130-1984) |
1000.0 |
|
| 15.1.a.iii (Wrapping Test ( For aluminum) as Per IS : 8130:1984 Clause 6.2.2) |
500.0 |
|
| 15.1.1 & 15.2.1 (FRLSH for all type of samples) |
20000.0 |
|
| 15.1.a.iv (Resistance Test Read With IS : 10810( Part 5)) |
2000.0 |
|
|
| 2922 |
National Test House (ER), Kolkata
| IS 191 (2007) - Copper - Specification (Fourth Revision) |
Copper - Specification (Fourth Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 7.1 (Copper + Silver ) |
2000.0 |
|
|
| 2923 |
National Test House (ER), Kolkata
| IRS:M-46 (2020) - INDIAN RAILWAYS STANDARD SPECIFICATION FOR CLASSIFICATION, TESTING AND ACCEPTANCE CRITERIA OF FILLER WIRES FOR MIG/MAG WELDING (WITH AND WITHOUT GAS SHIELDING) |
INDIAN RAILWAYS STANDARD SPECIFICATION FOR CLASSIFICATION, TESTING AND ACCEPTANCE CRITERIA OF FILLER WIRES FOR MIG/MAG WELDING (WITH AND WITHOUT GAS SHIELDING) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 4.2 (Size of Wire : Diameter) |
500.0 |
|
| 3.2 (Tensile Strength of Wire) |
3000.0 |
|
| 6.2.5 (Carbon) |
500.0 |
|
| 6.2.5 (Manganese) |
500.0 |
|
| 6.2.5 (Silicon) |
500.0 |
|
| 6.2.5 (Phosphorus) |
500.0 |
|
| 6.2.5 (Molybdenum) |
500.0 |
|
| 6.2.5 (Nickel) |
500.0 |
|
| 6.2.5 (Copper) |
500.0 |
|
| 6.2.5 (Chromium) |
500.0 |
|
| 6.2.5 (Vanadium) |
500.0 |
|
| 6.2.5 (Sulphur) |
500.0 |
|
|
| 2924 |
National Test House (ER), Kolkata
| NTHER- Calibration of Earth Resistivity Tester - Calibration of Earth Resistivity Tester |
Calibration of Earth Resistivity Tester |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| A.1 (Resistance) |
1200.0 |
|
| A.2 (Resistance) |
1800.0 |
|
| A.3 (Resistance) |
2400.0 |
|
|
| 2925 |
National Test House (SR), Chennai
| IS 8042 (2015) - White portland cement - Specification (Third Revision) |
White portland cement - Specification (Third Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6 (Compressive strength, ,672±4 h [as per IS 4031 (Part 6)], MPa) |
1000.0 |
|
| 6 (Compressive strength, 168 ± 2 h [as per IS 4031 (Part 6)], MPa) |
1000.0 |
|
| 6 (Compressive strength, 72±1 h [as per IS 4031 (Part 6)], MPa) |
1000.0 |
|
| 6 (Setting time Final [as per IS 4031 (Part 5)], minutes) |
500.0 |
|
| 6 (Setting time Initial [as per IS 4031 (Part 5)], minutes) |
500.0 |
|
| 6 (Soundness-autoclave method [as per IS 4031 (Part 3)], %) |
1000.0 |
|
| 6 (Soundness-Lechatlier method [as per IS 4031 (Part 3)], mm) |
500.0 |
|
| 5 (Magnesia (as per IS 4032), %) |
500.0 |
|
| 5 (Insoluble Residue (as per IS 4032), %) |
500.0 |
|
| 5 (Iron Oxide (as per IS 4032), %) |
500.0 |
|
| 5 (Ratio of lime to silica, alumina and iron oxide (as per IS 4032)) |
1000.0 |
|
| 5 (Total Sulphur Content calculated as SO3 (as per IS 4032), %) |
500.0 |
|
| 5 (Loss on ignition, (as per IS 4032), %) |
500.0 |
|
| 5 (Chloride Content, (as per IS 4032), %) |
500.0 |
|
| 6.1.1 (Progressive increase in strength -from the strength at 72 hrs) |
2000.0 |
|
| - (Consistency) |
500.0 |
|
|
| 2926 |
National Test House (ER), Kolkata
| JAPANESE INDUSTRIAL STANDARD JIS K 5659 (2018) - JAPANESE INDUSTRIAL STANDARD JIS K 5659 -Long Durable Paints for Steel Structures |
JAPANESE INDUSTRIAL STANDARD JIS K 5659 -Long Durable Paints for Steel Structures |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 7.4 (Condition inside container
As per 4.1.2 a of JIS K5600-1-1) |
1200.0 |
|
| 7.5 (Low temperature stability at (-5 deg.C) As per 3.3.7 of JIS K5600-1-1) |
5000.0 |
|
| 7.6 (Surface Drying Property as per JIS K 5600) |
1200.0 |
|
| 7.7 (Appearance of the Film ( As per of JIS K5600-1-1 )) |
1200.0 |
|
| 7.8 (Pot life) |
1500.0 |
|
| 7.9 (Contrast Ratio % As per of JIS K5600-4-1) |
1500.0 |
|
| 7.10 (Specular Gloss (60º) as per JIS K5600-4-7) |
1200.0 |
|
| 7.11 (Overcoatability) |
1200.0 |
|
| 7.12 (Flexibility 10 mm dia mandrel of type I tester as per JIS 5600-5-1) |
1200.0 |
|
| 7.13 (Falling weight Resistance 300 gram weight& drop height 500 mm (As per JIS K 5600-5-3)) |
1500.0 |
|
| 7.14 (Interlayer adhesion-I(between undercoat and intermediate coat)) |
2000.0 |
|
| 7.15 (Interlayer adhesion-II(between Intermediate coat & top coat)) |
2000.0 |
|
| 7.16 (Alkali Resistance (dilute Calcium Hydroxide),Immersing method, for 168 Hours at 23 ±1 Deg c) |
1500.0 |
|
| 7.18 (Humidity and Cool-Heat Cycling Resistance Test Condition :Immersion in water at 23 Deg C for 18 hours followed by cooling at -20 deg C for 03 Hours ,Heat at 50 deg C for 03 hours (10 Cycles)) |
10000.0 |
|
| 7.20 (Accelerated weathering Resistance- Xenon arc Exposure period 2000 hours
As per of JIS K5600-7-7) |
120000.0 |
|
| 7.20 b (Accelerated weathering Resistance by Xenon arc Exposure period 500 hours) after 24 Months Natural Weathering Resistance test (As per of JIS K5600-7-7)) |
15000.0 |
|
| 7.21 (Natural Weathering Resistance
(for 24 Months) as per JIS K 5600-7-6) |
20000.0 |
|
| 7.17 (Acid Resistance (dilute Sulfuric Acid 5gram per litre),Immersing method, for 168 Hours at 23 ±1 Deg c) |
1500.0 |
|
| 7.19 (Non Volatile Matter content % As per JIS K 5601-1-2) |
1200.0 |
|
|
| 2927 |
National Test House (ER), Kolkata
| JIS K 5674 :2008 (2008) - LEAD-FREE, CHROMIUM-FREE ANTICORROSIVE PAINTS |
LEAD-FREE, CHROMIUM-FREE ANTICORROSIVE PAINTS |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Clause 5 Table 1 (Please see Annexure) |
25000.0 |
|
|
| 2928 |
National Test House (ER), Kolkata
| JIS K 5552:2010 (2010) - ZINC RICH PRIMER |
ZINC RICH PRIMER |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Clause 5 Table 1 (Please see Annexure) |
25000.0 |
|
|
| 2929 |
National Test House (ER), Kolkata
| JIS K 5553 : 2002 (2002) - HIGH BUILD TYPE ZINC RICH PAINT |
HIGH BUILD TYPE ZINC RICH PAINT |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Clause 5 ,Table 1 (Please see Annexure) |
30000.0 |
|
|
| 2930 |
National Test House (ER), Kolkata
| JIS K 5551:2008 (2008) - HEAVY DUTY ANTICORROSIVE PAINTS FOR METAL STRUCTURES |
HEAVY DUTY ANTICORROSIVE PAINTS FOR METAL STRUCTURES |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Clause 5 Table 2 (Please see Annexure) |
30000.0 |
|
|
| 2931 |
National Test House (ER), Kolkata
| IS 16676 (2017) - Solventless liquid epoxy system for application on interior and exterior surfaces of steel water pipeline - Specification |
Solventless liquid epoxy system for application on interior and exterior surfaces of steel water pipeline - Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Vii (Solvent Rub Test) |
1200.0 |
|
| Vi (Cathodic Disbondment Test, Max) |
2000.0 |
|
| V (Abrasion Resistance, Max) |
2000.0 |
|
| IV (c) (Immersion & vapour phase c) Sodium hydroxide pass 1 percent by weight) |
2000.0 |
|
| IV (b) (Immersion & vapour phase b) Sulphuric acid pass 1 percent by weight.) |
2000.0 |
|
| IV (a) (Immersion & vapour phase a) De-ionized water) |
2000.0 |
|
| III (a) (Adhesion Test a)Tape Test) |
1200.0 |
|
| III (b) (Adhesion Test b)Pull off Test.) |
2500.0 |
|
| II (Electrical insulation (holidays)) |
2500.0 |
|
| 6.7 Table 1 I (Thickness, dry film, Min) |
1200.0 |
|
| 6.6 (Keeping Properties) |
2500.0 |
|
| 6.5 (Consistency) |
1200.0 |
|
| 6.4 (Recoating Properties) |
1200.0 |
|
| 6.3 (Application Properties) |
1200.0 |
|
| 6.2 (Thinning) |
1200.0 |
|
| 6.1 (Condition) |
1200.0 |
|
|
| 2932 |
National Test House (ER), Kolkata
| JIS K 5659:2018 (2018) - LONG DURABLE PAINTS FOR STEEL STRUCTURES |
LONG DURABLE PAINTS FOR STEEL STRUCTURES |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Clause 5 Table 2 Top Coat Type A (Please see Annexure) |
40000.0 |
|
| Clause 5 Table 2 Intermediate CoatType A (Please see Annexure) |
40000.0 |
|
| Clause 5 Table 2 Top Coat Type B (Please see Annexure) |
1.0 |
|
| Clause 5 Table 2 Type B Intermediate Coat (Please see Annexure) |
1.0 |
|
| 5 Table 2 LONG DURABLE PAINTS FOR STEEL STRUCTURES ( ZINC RICH PRIMER) TYPE A (Please see Annexure) |
55000.0 |
|
| 5 Table 2 (LONG DURABLE PAINTS FOR STEEL STRUCTURES( Intermediate) TYPE A (Please see Annexure) |
45000.0 |
|
| 5 Table 2 LONG DURABLE PAINTS FOR STEEL STRUCTURES (Undercoat) TYPE A (Please see Annexure) |
20000.0 |
|
| 5 Table 2 LONG DURABLE PAINTS FOR STEEL STRUCTURES( FINISH) TYPE A (Please see Annexure) |
50000.0 |
|
|
| 2933 |
National Test House (NWR), Jaipur
| IS 4027 : Part 6 (1987) - Methods of chemical analysis of bronzes: Part 6 determination of zinc by complexometric (EDTA) method (First Revision) |
Methods of chemical analysis of bronzes: Part 6 determination of zinc by complexometric (EDTA) method (First Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 4 (Zinc % by mass) |
2000.0 |
|
|
| 2934 |
National Test House (NWR), Jaipur
| IS 4027 : Part 1 (1987) - Methods of chemical analysis of bronzes: Part 1 determination of copper and lead by electrolytic method (First Revision) |
Methods of chemical analysis of bronzes: Part 1 determination of copper and lead by electrolytic method (First Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 4 (Copper) |
2000.0 |
|
|
| 2935 |
National Test House (ER), Kolkata
| IS 12894 (2002) - Pulverized fuel ash - Lime bricks - Specification |
Pulverized fuel ash - Lime bricks - Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 7.2 (Drying Shrinkage) |
2000.0 |
|
| 7.3 (Efforescence) |
1000.0 |
|
| 7.4 (Water Absorption) |
1000.0 |
|
| 7.1 (Crushing Strength) |
2000.0 |
|
| 5 (Dimensions) |
500.0 |
|
| 3 (General quality) |
500.0 |
|
|
| 2936 |
National Test House (ER), Kolkata
| RDSO/M&C/RP-198 (2006) - COMPOSITE GROOVED RUBBER SOLE PLATES FOR PLACING BENEATH RAILS |
COMPOSITE GROOVED RUBBER SOLE PLATES FOR PLACING BENEATH RAILS |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 3.2 (Hardness) |
1000.0 |
|
| 3.2 (Compression Set) |
3000.0 |
|
| 3.2 (Relaxed Modulus at 100% elongation before ageing) |
1000.0 |
|
| 3.2 (Tension Set) |
3000.0 |
|
| 3.2 (Electrical Resistance after immersion) |
5000.0 |
|
| 3.2 (Electrical Resistance Before immersion) |
5000.0 |
|
| 3.2.2 (Ash Content) |
2000.0 |
|
| 3.2.2 (Specific Gravity) |
1000.0 |
|
| 3.2 (Relaxed Modulus at 100% elongation, Change after ageing) |
1000.0 |
|
| 3.2 (Elongation at break, Before ageing) |
1500.0 |
|
| 3.2 (Elongation at Break, After ageing) |
1500.0 |
|
| 3.2 (Elongation at Break, Retention after ageing) |
1000.0 |
|
| 3.2 (Tensile Strength, Before ageing) |
1500.0 |
|
| 3.2 (Tensile Strength, After ageing) |
1500.0 |
|
| 3.2 (Tensile Strength, Retention after Ageing) |
1000.0 |
|
| 3.1.3 (Thickness of Composite Pad) |
1000.0 |
|
|
| 2937 |
National Test House (ER), Kolkata
| IS 2202 : Part 1 (2023) - Wooden flush door shutters (Solid Core Type) - Specification: Part 1 plywood face panels (Sixth Revision) |
Wooden flush door shutters (Solid Core Type) - Specification: Part 1 plywood face panels (Sixth Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 11.15 (Screw Withdrawal Resistance Test-IS 4020 (Part 16):1998) |
1500.0 |
|
| 11.14 (Glue Adhesion Test-IS 4020 (Part 15):1998 for BWP and (60± 2)°C for MR) |
1000.0 |
|
| 11.13 (Knife test-IS 4020 (Part 14):1998) |
1000.0 |
|
| 11.12 (End Immersion Test-IS 4020 (Part 13):1998 for BWP and 3cycle for MR) |
1000.0 |
|
| 11.11 (Varying Humidity Test-IS 4020 (Part 12):1998) |
3000.0 |
|
| 11.10 (Misuse Test-IIS 4020 (Part 11):1998) |
1000.0 |
|
| 11.9.2 or 11.9.3 (Slamming Test-Cl 2.1 or 3.1 of IS 4020 (Part 10):1998) |
1000.0 |
|
| 11.8 (Buckling Test-IS 4020 (Part 9):1998) |
1500.0 |
|
| 11.7.1 and 11.7.2 (Shock Resistance test- Cl 2.1 & 3.1 of IS 4020 (Part 8):1998) |
1500.0 |
|
| 11.6 (Edge loading test-IS 4020 (Part 7):1998) |
1500.0 |
|
| 11.4 (Impact Indentation-IS 4020 (Part 5):1998) |
1000.0 |
|
| 11.3 (Local planeness Test-IS 4020 (Part 4):1998) |
1000.0 |
|
| 11.2 (General Flatness-IS 4020 (Part 3):1998) |
1000.0 |
|
| 11.1 (Dimensions and Squareness-IS 4020 (Part 2):1998) |
2000.0 |
|
| 9 (Workmanship and Finish-IS 2202 (Part 1):1999) |
1000.0 |
|
|
| 2938 |
National Test House (ER), Kolkata
| RDSO/2007/GE:0014 November 2009 (November 2009) - Guidelines and Specifications for Design of Formation for Heavy Axle Load
(RDSO/2007/GE:0014 ) |
Guidelines and Specifications for Design of Formation for Heavy Axle Load
(RDSO/2007/GE:0014 ) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 12.1(i-a) (The uniformity coefficient (Cu)
IS 2720-1 (1983)/IS 1498 (1970)) |
1500.0 |
|
| 12.1.(i-b) (The Coefficient of Curvature (Cc)
IS 2720-1 (1983)/IS 1498 (1970)) |
1500.0 |
|
| 12.1.(ii) (Los Angeles Abrasion Value (IS 2386(4):1963)) |
1500.0 |
|
| 12.1(iv) (OMC & MDD (Proctor Test) [IS 2720 (Part 8)]) |
5000.0 |
|
| 12.2 (Sieve Analysis/Grading Percentage /Grain size distribution [IS 2720 (Part 4)]) |
5000.0 |
|
| - (Liquid Limit [IS 2720-5(1985)]) |
1000.0 |
|
| - (Plastic limit [IS 2720-5(1985)]) |
1000.0 |
|
| - (Shrinkage limit [IS 2720-6 (1972)]) |
1000.0 |
|
| 12.1.iv) (CBR value (Soaked)) |
6000.0 |
|
|
| 2939 |
National Test House (NR), Ghaziabad
| IS 1161 (2014) - Steel Tube for Structural Purposes |
Steel Tube for Structural Purposes |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6.1 (Outside Diameter) |
500.0 |
|
| 6.1 (Thickness) |
500.0 |
|
| 6.1 (Weight) |
1000.0 |
|
| 7 (Workmanship) |
1000.0 |
|
| 9 (Straightness) |
1000.0 |
|
| 11.2 (Tensile Strength, MPa) |
1000.0 |
|
| 11.2 (Yield strength, MPa) |
1000.0 |
|
| 11.2 (Percent Elongation, %) |
1000.0 |
|
| 11.3 (Cold Bend test) |
- |
|
| 11.3 (Bend Test / Flattening test) |
1000.0 |
|
| 8 (Mass of Zinc Coating) |
2000.0 |
|
| 0 (Coating Thickness, micron) |
2000.0 |
|
| 0 (Uniformity of Coating) |
1000.0 |
|
| 0 (Overall Length) |
1000.0 |
|
| 0 (Adhesion test) |
1000.0 |
|
| 0 (Salt Spray Test) |
60000.0 |
|
|
| 2940 |
National Test House (NR), Ghaziabad
| RDSO SPEC M&C/PCN/103/2020 (2020) - SPECIFICATION FOR EPOXY BASED MICACEOUS IRON OXIDE (TWO- PACK) |
SPECIFICATION FOR EPOXY BASED MICACEOUS IRON OXIDE (TWO- PACK) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Cl 3 & 4 (Table-I & II) (Please see Annexures (All physico mechanical & Chemical tests)) |
40000.0 |
|
|