| 1 |
National Test House (WR), Mumbai
| IS 398 Part 2 (2025) - ALUMINIUM CONDUCTORS FOR OVERHEAD TRANSMISSION PURPOSES |
ALUMINIUM CONDUCTORS FOR OVERHEAD TRANSMISSION PURPOSES |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 0 (Mechanical Test As per Annexure) |
6000.0 |
|
| 0 (Resistance Test) |
1000.0 |
|
| 13.6 (Resistance Test Clause 13.6 (Table 1)) |
2000.0 |
|
| Annexure A-3 & Table 3 (Approximate breaking load of conductors) |
2000.0 |
|
| 3.3 (Measurement of Diameter of individual Aluminum Wires) |
3500.0 |
|
|
| 2 |
National Test House (WR), Mumbai
| IS 398 : Part 1 (1996) - Aluminium conductors for overhead transmission purposes - Specification: Part 1 aluminium stranded conductors (Third Revision) |
Aluminium conductors for overhead transmission purposes - Specification: Part 1 aluminium stranded conductors (Third Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
| 3 |
National Test House (WR), Mumbai
| IS 398 : Part 2 (1996) - Aluminium conductors for overhead transmission purposes - Specification: Part 2 aluminium conuuctors, galvanized steel - Reinforced (Third Revision) |
Aluminium conductors for overhead transmission purposes - Specification: Part 2 aluminium conuuctors, galvanized steel - Reinforced (Third Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 0 (ACSR Conductor Acceptance & Type Tests) |
34000.0 |
|
| 0 (ACSR Conductor Acceptance Tests) |
14000.0 |
|
| 0 (ACSR Conductor Type Tests) |
20000.0 |
|
|
| 4 |
National Test House (WR), Mumbai
| NTH_CUSTOM/2026/021 - Custom standard (NTH WR) Chemical |
Custom standard (NTH WR) Chemical |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| - (As refer Annexure) |
40500.0 |
|
|
| 5 |
National Test House (NER), Guwahati
| IS 7098 : Part 2 (2011) - Crosslinked polyethylene insulated thermoplastic sheathed cables - Specification: Part 2 for working voltages from 3.3 kV up to and including 33 kV (Second Revision) |
Crosslinked polyethylene insulated thermoplastic sheathed cables - Specification: Part 2 for working voltages from 3.3 kV up to and including 33 kV (Second Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 19.2.(k) (Volume resistivity at 90 Degree C-B) |
1000.0 |
|
| 19.2.(k) (Volume resistivity at 90 Degree C-Y) |
1000.0 |
|
| 19.2.(k) (Volume resistivity at 90 Degree C-R) |
1000.0 |
|
| 19.2.(k) (Volume resistivity at ambient temperature (27 degree C +/- 2 degree C )-Black) |
1000.0 |
|
| 19.2.(k) (Volume resistivity at ambient temperature (27 degree C +/- 2 degree C )-B) |
1000.0 |
|
| 19.2.(k) (Volume resistivity at ambient temperature (27 degree C +/- 2 degree C )-Y) |
1000.0 |
|
| 19.2.(k) (Volume resistivity at ambient temperature (27 degree C +/- 2 degree C )-R) |
1000.0 |
|
| 19.2.(k) (Volume resistivity at 90 Degree C-Black) |
1000.0 |
|
|
| 6 |
National Test House (ER), Kolkata
| IS 6603 (2024) - Stainless Steel Semi-Finished Products, Bars, Wire Rods and Bright Bars — Specification (2nd Revision) |
Stainless Steel Semi-Finished Products, Bars, Wire Rods and Bright Bars — Specification (2nd Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6 (Freedom From Defects - Visual Examination as per IS 6603 Cl.6.1 & 6.2) |
1000.0 |
|
| 7 (Chemical Composition-The ladle analysis of steel, when carried out either by the methods specified in relevant parts of IS 228 or any other established international instrumental/chemical method) |
5000.0 |
|
| 9.0 Mechancial Properites (The tensile test ( Tensile Stregth, 0.2% Proof/Yield Stress, % of Elongation ) shall be carried out in accordance with IS 1608 (Part 1)) |
3000.0 |
|
| 9.0 Mechnaical Properties (The tensile properties at elevated temperature mentioned in Table 10 to Table 14
The tensile test ( Tensile Stregth, 0.2% Proof/Yield Stress, % of Elongation ) shall be carried out in accordance with IS 1608 (Part 2)) |
5000.0 |
|
| 9.0 Mechancial Properties (Hardness shall be determined in accordance with IS 1500 (Part 1), IS 1501 (Part 1) or IS 1586
(Part 1).) |
2000.0 |
|
| 9.0 Mechanical Properties (Charpy impact test shall be carried out in accordance with IS 1757 (Part 1).) |
5000.0 |
|
| 12 (Dimesnion Measurment in mm
dimensional tolerances for the bars and flats shall be as laid down in Table 26 to Table 36 given at Annex C of IS 6603) |
1000.0 |
|
|
| 7 |
National Test House (ER), Kolkata
| # IS 17876 (2022) - Stainless Steel Welded Pipes and Tubes for General Services |
Stainless Steel Welded Pipes and Tubes for General Services |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Cl 8 (Chemical composition) |
5000.0 |
|
| Cl 10.1 (Yield strength) |
1000.0 |
|
| Cl 10.1 (Tensile strength) |
1000.0 |
|
| Cl 10.1 (% Elongation) |
1000.0 |
|
| - (Weight per meter) |
1000.0 |
|
|
| 8 |
National Test House (ER), Kolkata
| # IS 6911 - SS,Plate, Sheet / Strip |
SS,Plate, Sheet / Strip |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6 (Visual) |
1000.0 |
|
| 15 (Surface Finish) |
1000.0 |
|
| 10.2 (Hardness) |
2000.0 |
|
| 17 (Dimensions) |
1000.0 |
|
| 10.3 (Bend test) |
1000.0 |
|
| Cl 7.1 & 7.2 (Chemical analysis) |
5000.0 |
|
|
| 9 |
National Test House (NER), Guwahati
| NTH_CUSTOM/2026/017 - Custom Specification for Coated Fabrics |
Custom Specification for Coated Fabrics |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Weight) |
1000.0 |
|
| 2 (Thickness) |
1000.0 |
|
| 3 (Breaking Strength (Warp)) |
1000.0 |
|
| 4 (Breaking Strength (Weft)) |
1000.0 |
|
| 5 (Elongation at break (Warp)) |
1000.0 |
|
| 6 (Elongation at break (Weft)) |
1000.0 |
|
| 7 (Tear Strength (Warp)) |
1000.0 |
|
| 8 (Tear Strength (Weft)) |
1000.0 |
|
| 9 (Adhesion Strength) |
2000.0 |
|
| 10 (Identification of Polymer) |
2000.0 |
|
|
| 10 |
National Test House (NER), Guwahati
| NTH_CUSTOM/2026/016 - Custom Specification for Paper |
Custom Specification for Paper |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Grammage) |
159000.0 |
|
|
| 11 |
National Test House (ER), Alipore
| # IS 15041 (2025) - TEXTILES - FLAT WOVEN WEBBING SLINGS MADE FROM MANMADE FIBRES FOR GENERAL SERVICES - SPECIFICATION (FIRST REVISION) |
TEXTILES - FLAT WOVEN WEBBING SLINGS MADE FROM MANMADE FIBRES FOR GENERAL SERVICES - SPECIFICATION (FIRST REVISION) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5.5 (Working load limit) |
10000.0 |
|
| 5.6 (Maximum safe working load) |
3000.0 |
|
| 5.7 (Safety factor / tensile test) |
3000.0 |
|
| 5.8 (Proof load testing) |
3000.0 |
|
| 5.5 (Working Load Limit(WLL)) |
6000.0 |
|
| 5.6 (Maximum safe working) |
6000.0 |
|
| 5.7 (Safety Factor/ Tensile Test) |
6000.0 |
|
| 5.8 (Proof load testing) |
6000.0 |
|
| 5.5 (Working Load Limit(WLL)) |
8000.0 |
|
| 5.6 (Maximum safe working load) |
8000.0 |
|
| 5.7 (Safety Factor / Tensile Test) |
8000.0 |
|
| 5.8 (Proof Load Testing) |
8000.0 |
|
| 5.5 (Working Load Limit) |
10000.0 |
|
| 5.6 (Maximum Safe Working Load) |
10000.0 |
|
| 5.7 (Safety Factor/ Tensile Test) |
10000.0 |
|
| 5.8 (Proof Load Testing) |
10000.0 |
|
|
| 12 |
National Test House (NWR), Jaipur
| # IS 14543 (2024) - Specification for Packaged Drinking Water (Other Than Packaged Natural Mineral Water) |
Specification for Packaged Drinking Water (Other Than Packaged Natural Mineral Water) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Cl. 5.3 (pH) |
250.0 |
|
|
| 13 |
National Test House (NWR), Jaipur
| 3025 - Customised specification for drinking water. |
Customised specification for drinking water. |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
| 14 |
National Test House (NWR), Jaipur
| IS 3025 - Water/Raw water/Sewage/Drainage |
Water/Raw water/Sewage/Drainage |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Please see the Annexure) |
15000.0 |
|
|
| 15 |
National Test House (NWR), Jaipur
| IS:3025 - Methods of sampling and test (Physical & chemical) for water and waste water |
Methods of sampling and test (Physical & chemical) for water and waste water |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| CL 8 (Part 44,58,11,16 &17 ) Essential Parameters (Please see Annexure) |
12000.0 |
|
| 6,Table1 ICP-OES Elements (Please see Annexure) |
7000.0 |
|
| Cl 8 Essential Parameters as per NMCG Requirement (Cl 8 -Essential Parameters as per NMCG Requirement (Please see Annexure)) |
10000.0 |
|
| APHA-23 edition Microbiological Parameters as per NMCG(Please see Annexure) (APHA-23 edition Microbiological Parameters as per NMCG(Please see Annexure)) |
2000.0 |
|
|
| 16 |
National Test House (NER), Guwahati
| # IS 7098 (2025) - Crosslinked Polyethylene Insulated Thermoplastic Sheathed Cables - Specification - Part 1 For Working Voltages up to and including 1100 Volts |
Crosslinked Polyethylene Insulated Thermoplastic Sheathed Cables - Specification - Part 1 For Working Voltages up to and including 1100 Volts |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 16.1 (i) (a) (Annealing Test (for Copper) - on Conductor) |
1000.0 |
|
| 16.1 (i) (b) (Tensile Test (for Aluminium)- on Conductor) |
1000.0 |
|
| 16.1 (i) (c) (Wrapping Test (for Aluminium) - on Conductor) |
500.0 |
|
| 16.1 (i) (d) (Resistance Test - on Conductor) |
2000.0 |
|
| 16.1 (iv) (a) (Tensile strength and elongation at break - for insulation) |
1500.0 |
|
| 16.1 (iv) (b) (Ageing in air oven - for insulation) |
2000.0 |
|
| 16.1 (iv) (c) (Hot set test - for insulation) |
1000.0 |
|
| 16.1 (iv) (d) (Shrinkage test - for insulation) |
1000.0 |
|
| 16.1 (iv) (e) (Water absorption (gravimetric) - for insulation) |
2000.0 |
|
| 16.1 (v) (a) (1) (Tensile strength and elongation at break - for outer sheath) |
1000.0 |
|
| 16.1 (v) (a) (2) (Ageing in air oven - for outer sheath) |
1000.0 |
|
| 16.1 (v) (a) (3) (Loss of mass in air oven - for outer sheath) |
1000.0 |
|
| 16.1 (v) (a) (4) (Shrinkage Test - for outer sheath) |
500.0 |
|
| 16.1 (v) (a) (5) (Hot deformation test - for outer sheath) |
500.0 |
|
| 16.1 (v) (a) (6) (Heat shock test - for outer sheath) |
500.0 |
|
| 16.1 (v) (a) (7) (Thermal stability - for outer sheath) |
1000.0 |
|
| 16.1 (vi) (Insulation resistance (volume resistivity test)) |
2000.0 |
|
| 16.1 (vii) (High voltage test) |
2000.0 |
|
| 16.1 (viii) (Flammability test) |
500.0 |
|
| 16.1 (ix) (a) (1) (Oxygen index test - Category C1) |
5000.0 |
|
| 16.1 (ix) (a) (2) (Temperature index test - Category C1) |
5000.0 |
|
| 16.1 (ix) (b) (5) (Smoke density test - Category C2) |
5000.0 |
|
| 16.1 (ix) (b) (6) (Test for halogen acid evolution - Category C2) |
5000.0 |
|
| 16.1 (ii) (Test on Armouring Wire / Strips) |
5000.0 |
|
|
| 17 |
National Test House (SR), Chennai
| # IS 383 (2016) - Fine Aggregate -M sand Full test |
Fine Aggregate -M sand Full test |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5.2.1 (Dleterious materials & Organic compounds) |
2000.0 |
|
| 5.5 (Soundness) |
2000.0 |
|
| 5.6 (Alkali aggregate reaction(Chemical/MB method)) |
3000.0 |
|
| 6 (Size and Grading of aggregates) |
2000.0 |
|
| 5.7 & 7.2 (Total alkali content) |
1000.0 |
|
| 5.7 & 7.2 (Total Sulphate content) |
1200.0 |
|
| 5.7 & 7.2 (Water soluble chloride content) |
1200.0 |
|
| 5.7 (Water absorption) |
1000.0 |
|
| 5.7 (Specific Gravity) |
1000.0 |
|
| 7.2 (Bulk density (custom test)) |
1000.0 |
|
| 7.2 (Bulking of sand(custom test)) |
1000.0 |
|
| 7.2 (Silt content-CPWD specification(custom test)) |
1000.0 |
|
| 6 (Microfines content(custom test)) |
1000.0 |
|
| 5.2.1 (Organic compounds) |
1000.0 |
|
|
| 18 |
National Test House (SR), Chennai
| # IS 383 (2016) - Coarse and Fine Aggregate -River sand Full test |
Coarse and Fine Aggregate -River sand Full test |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
| 19 |
National Test House (WR), Mumbai
| AWWA C222-18 (2018) - Polyurethane Coatings and Linings for Steel Water Pipe and Fittings |
Polyurethane Coatings and Linings for Steel Water Pipe and Fittings |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
| 20 |
National Test House (WR), Mumbai
| IS 13213 (2018) - Polyurethane full gloss enamel (Two Pack) - Specification (First Revision) |
Polyurethane full gloss enamel (Two Pack) - Specification (First Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Cl 1 Table 1 (Please see Annexure (All possible Tests)) |
60000.0 |
|
| Cl 1 Table 1 (Please see Annexure Durability ( Outdoor exposure only) + Keeping properties) |
30000.0 |
|
|
| 21 |
National Test House (NWR), Jaipur
| IS/IEC : 60529 (2001 reaff : 2019) - Degree of Protection Provided by Enclosure(IP CODE) |
Degree of Protection Provided by Enclosure(IP CODE) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 13.4/13.5 First Characteristic Numeral 6 (No ingress of Dust) |
7500.0 |
|
| 14.2.7, Second characteristic numeral 7 (14.2.7, Second characteristic numeral 7 :Protected against the effects of temporary immersion in water) |
7500.0 |
|
|
| 22 |
National Test House (WR), Mumbai
| Custom-34-NTH-LM - W-Beam Metal Crash Barrier |
W-Beam Metal Crash Barrier |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Tensile Strength) |
2000.0 |
|
| 2 (Yield stress) |
1000.0 |
|
| 3 (Elongation) |
1000.0 |
|
| 4 (Mass per Metre) |
1500.0 |
|
| 5 (Bend Test) |
1000.0 |
|
| 6 (Carbon) |
500.0 |
|
| 7 (Sulphur) |
500.0 |
|
| 8 (Phosphorus) |
500.0 |
|
| 9 (Manganese) |
500.0 |
|
| 10 (Carbon Equivalent) |
500.0 |
|
|
| 23 |
National Test House (WR), Mumbai
| # IS 5986 - W Beam & C Post |
W Beam & C Post |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| - (Chemical composition) |
3500.0 |
|
| Cl 8.3 (Yield strength) |
1000.0 |
|
| Cl 8.3 (Tensile strength) |
1000.0 |
|
| Cl 8.3 (% Elongation) |
1000.0 |
|
| Cl 16 (Weight per meter) |
1000.0 |
|
| Cl 13 (Freedom from defect) |
1000.0 |
|
| Cl 9 (Bend Test) |
1000.0 |
|
| - (Mass of Zinc Coating) |
2000.0 |
|
| - (Uniformity of Coating) |
1000.0 |
|
| Cl 15 (Dimensions) |
1000.0 |
|
|
| 24 |
National Test House (WR), Mumbai
| IS 5986 (2017) - Hot rolled steel sheet, plate and strip for forming and flanging purposes - Specification (Fourth Revision) |
Hot rolled steel sheet, plate and strip for forming and flanging purposes - Specification (Fourth Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 9.2.2 (Bend Test) |
1500.0 |
|
|
| 25 |
National Test House (WR), Mumbai
| AWWA C210-15 (2015) - Solvent Free Liquid epoxy Coating (Red / Grey) for steel Water pipeline &Fittings Internal |
Solvent Free Liquid epoxy Coating (Red / Grey) for steel Water pipeline &Fittings Internal |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
| 26 |
National Test House (NR), Ghaziabad
| NTH_CUSTOM/2026/015 - NTH/NR/CH/002 |
NTH/NR/CH/002 |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Dry Material Content ) |
1000.0 |
|
| 2 (Chloride Content ) |
1000.0 |
|
| 3 (Alkali Content ) |
1500.0 |
|
|
| 27 |
National Test House (WR), Mumbai
| NTH_CUSTOM/2026/014 (2001) - # Customized specification of Hot refreshment Box in oven at 180-220 deg.C for 12-15 minutes |
# Customized specification of Hot refreshment Box in oven at 180-220 deg.C for 12-15 minutes |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Thermal Resistance /Heat ageing test for Hot refreshment Box in oven at 180-220 deg.C for 12-15 minutes) |
2000.0 |
|
|
| 28 |
National Test House (WR), Mumbai
| Customized specification for IS 14933:2001 - Customized specification for IS 14933:2001 |
Customized specification for IS 14933:2001 |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
| 29 |
National Test House (NR), Ghaziabad
| NTH_CUSTOM/2026/014 (1994) - Aluminium Conductor For Overhead Transmission Purposes |
Aluminium Conductor For Overhead Transmission Purposes |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Mechanical Test As Per Annexure) |
6000.0 |
|
| 2 (Resistance Test) |
2000.0 |
|
| 3 (Mechanical Test for 37 wire or other As per Annexure) |
8000.0 |
|
|
| 30 |
National Test House (NR), Ghaziabad
| # IS 516 (2021) - Hardened concrete methods of test part 1 testing of strength of hardened concrete section 1 compressive,flexucal and split tensile strength (First Revision) |
Hardened concrete methods of test part 1 testing of strength of hardened concrete section 1 compressive,flexucal and split tensile strength (First Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 3 (Concrete -Compressive Strength of CC Cube 1 set) |
1200.0 |
|
|