| 511 |
IS 1500 : Part 1 (2019) - Metallic materials - Brinell hardness test: Part 1 test method (Fifth Revision) |
Metallic materials - Brinell hardness test: Part 1 test method (Fifth Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Hardness) |
2000.0 |
|
|
| 512 |
IS 513 : Part 2 (2016) - Cold reduced carbon steel sheet and strip: Part 2 high tensile and multi - Phase steel (Sixth Revision) |
Cold reduced carbon steel sheet and strip: Part 2 high tensile and multi - Phase steel (Sixth Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 7.1 (Yield stress) |
1000.0 |
|
| 7.2 (Bend Test) |
1000.0 |
|
| 10 (Thickness) |
1000.0 |
|
|
| 513 |
IS 2062 Part 1 (2025) - Hot rolled medium and high tensile structural steel - Specification (Seventh Revision) |
Hot rolled medium and high tensile structural steel - Specification (Seventh Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 10 (Tensile Strength - IS 1608 (Part 1): 2022) |
1000.0 |
|
| 10 (Yield Stress - - IS 1608 (Part 1): 2022.) |
1000.0 |
|
| 10 (% Elongation - IS 1608 (Part 1): 2022.) |
1000.0 |
|
| 11 (Bend Test - IS 1599: 2019.) |
1500.0 |
|
| 12 (Impact Test (For Specified Quality Grade)) |
5000.0 |
|
| 8.2 (Carbon) |
500.0 |
|
| 8.2 (Sulphur) |
500.0 |
|
| 8.2 (Phosphorus) |
500.0 |
|
| 8.2 (Manganese) |
500.0 |
|
| 8.2 (Silicon) |
500.0 |
|
| 8.2 (Carbon Equivalent, %) |
500.0 |
|
| 0 (Percent elongation test, %) |
3000.0 |
|
| 0 (Yield strength Test, N/mm2) |
3000.0 |
|
| 0 (Tensile strength & Yield Strength Test, N/mm2) |
5000.0 |
|
| 0 (Thickness) |
500.0 |
|
| 0 (Coating Thickness) |
2000.0 |
|
| 0 (Mass of Zinc Coating) |
2000.0 |
|
| 0 (Uniformity of Coating) |
1000.0 |
|
| 0 (Salt Spray Test) |
60000.0 |
|
| 0 (Overall Weight) |
1500.0 |
|
| 0 (Dimensions) |
1000.0 |
|
| 12 (Impact Test) |
5000.0 |
|
| 7 (Freedom from Defects) |
1000.0 |
|
| 0 (Adhesion Test) |
1000.0 |
|
|
| 514 |
IS 1786 (2008) - High strength deformed steel bars and wires for concretere inforcement - Specification (Fourth Revision) |
High strength deformed steel bars and wires for concretere inforcement - Specification (Fourth Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5.7 (5) (Percentage increase in Bond Stress of Deformed Bar against corresponding Plain Bar at 0.25 mm slip (For size up to 12 mm), % - IS 2770(Part 1)) |
1250.0 |
|
| 4.2 (17) (Chemical Composition without micro alloying elements, % by mass.) |
2000.0 |
|
| 9.4 (1) (Rebend test (32 to 40mm)- IS 1786: 2008) |
1500.0 |
|
| 9.3 (Bend test - IS 1599: 2023.) |
1000.0 |
|
| 7.2 (Mass per metre run, kg/m - IS 1786: 2008) |
1000.0 |
|
| 9.2 (1) (TS/ YS Ratio - (IS 1786: 2008/ IS 1608 (Part 1): 2022).) |
- |
|
| 9.2 (2) (Elongation Percent on gauge length of 5.65 Square Root of Crosss- Sectional Area, % - IS 1608 (Part 1): 2022.) |
1000.0 |
|
| 9.2 (6) (Tensile Strength (32 to 40 mm), N/mm² - IS 1608 (Part 1): 2022.) |
1500.0 |
|
| 4.2 (2) (Carbon, % by mass (As per ASTM E 415/ IS 8811/IS 228).) |
500.0 |
|
| 4.2 (3) (Sulphur, % by mass (As per ASTM E 415/ IS 8811/IS 228)) |
500.0 |
|
| 4.2 (4) (Phosphorus, % by mass (As per ASTM E 415/ IS 8811/IS 228)) |
500.0 |
|
| 4.2 (5) (Sulphur+ Phosphorus, % by mass.) |
500.0 |
|
| 9.2 (4) (Tensile Strength (up to 12 mm), N/mm² - IS 1608 (Part 1): 2022.) |
- |
|
| 9.2 (5) (Tensile Strength (16 to 28 mm), N/mm² - IS 1608 (Part 1): 2022.) |
1000.0 |
|
| 9.2 (6) (Tensile Strength (32 to 40 mm), N/mm² - IS 1608 (Part 1): 2022.) |
1500.0 |
|
| 9.4 (Rebend test (0 - 28 mm) - IS 1786: 2008) |
1000.0 |
|
| 9.3 (Bend test - IS 1599: 2023.) |
1000.0 |
|
| 9.2 (2) (Elongation Percent on gauge length of 5.65 Square Root of Crosss- Sectional Area, % - IS 1608 (Part 1): 2022.) |
1000.0 |
|
| 9.2 (Yield Stress/ 0.2 % Proof Stress. N/mm² -- IS 1608 (Part 1): 2022.) |
1000.0 |
|
| 9.2 (3) (Total Elongation at Maximum Force on gauge length of 5.65 Square Root of Crosss- Sectional Area, % - IS 1608 (Part 1): 2022.) |
- |
|
| 9.1.1 (Tensile Strength) |
3000.0 |
|
| 9.1.2 (Yield/0.2% Proof Stress) |
3000.0 |
|
| 9.1.3 (Percentage Elongation) |
3000.0 |
|
| 4.2 (1) (Carbon Equivalent (CE), , % by mass.(As per ASTM E 415/ IS 8811/IS 228/IS 3025)) |
2000.0 |
|
| 0 (Salt spray test 48hrs as per ASTM B117) |
2000.0 |
|
| 0 (Test for thickness of coating) |
3000.0 |
|
| 5.7 (Pull out test upto 32mm) |
15000.0 |
|
|
| 515 |
IS 513 : Part 1 (2016) - Cold reduced carbon steel sheet and strip: Part 1 cold forming and drawing purpose (Sixth Revision) |
Cold reduced carbon steel sheet and strip: Part 1 cold forming and drawing purpose (Sixth Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 11 (Thickness) |
1000.0 |
|
| 8.1 (Yield stress) |
1000.0 |
|
| 8.3 (Hardness Test) |
2000.0 |
|
| 8.1 (Tensile strength) |
1000.0 |
|
| 8.1 (% Elongation) |
1000.0 |
|
| 8.4 (Bend Test) |
1000.0 |
|
|
| 516 |
IS 277 (2018) - Galvanized steel strips and sheets (Plain And Corrugated) - Specification (Seventh Revision) |
Galvanized steel strips and sheets (Plain And Corrugated) - Specification (Seventh Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 8.1 (Tensile strength, MPa) |
1000.0 |
|
| 8.1 (Yield Strength, MPa) |
1000.0 |
|
| 8.1 (Percentage Elongation, %) |
1000.0 |
|
| 8.2 (Bend Test) |
1000.0 |
|
| 14 (Total coated thickness, mm) |
1000.0 |
|
| 8.1 (Mass of Zn coating) |
2000.0 |
|
| 5.1 (Phosphorus) |
500.0 |
|
| 5.1 (Sulphur) |
500.0 |
|
| 5.1 (Manganese) |
500.0 |
|
| 5.1 (Carbon) |
500.0 |
|
| 0 (Thickness of Paint coating at side 1) |
1000.0 |
|
| 0 (Thickness of Paint coating at side 2) |
1000.0 |
|
| 0 (Base metal thickness, mm) |
1000.0 |
|
| 15 (Dimensions of Corrugated sheet) |
1000.0 |
|
| 12 (Freedom from defects) |
1000.0 |
|
| 0 (Pencil Hardness Test as per IS 14246) |
1000.0 |
|
|
| 517 |
IBR 1950 (2023) - Qualified Boiler Welder's Certificate |
Qualified Boiler Welder's Certificate |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| IBR-1950, Chapter -XIII (Welder Test - Plate) |
3000.0 |
|
| NTH Additional Charges for Testing (Scientist Charges) |
5000.0 |
|
| IBR-1950, Chapter -XIII (IBR Welder Test - Tube/Pipe (MMAW)- Horizontally Fixed) |
3500.0 |
|
| IBR-1950, Chapter -XIII (IBR Welder Test - Tube/Pipe (MMAW)- Vertically Fixed) |
3500.0 |
|
| IBR-1950, Chapter -XIII (IBR Welder Test - Tube/Pipe (GTAW+ MMAW)- Horizontally Fixed) |
4500.0 |
|
| IBR-1950, Chapter -XIII (IBR Welder Test - Tube/Pipe (GTAW+ MMAW)- Vertically Fixed) |
4500.0 |
|
| 0 (Scientist charge 2) |
5000.0 |
|
|
| 518 |
ASME ASME (2021) - Performance test ( Plate & electrodes not supplied by NTH) |
Performance test ( Plate & electrodes not supplied by NTH) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| ASME (Welding procedure qualification) |
7000.0 |
|
| QB 484 (Brazing Performance Test) |
5000.0 |
|
|
| 519 |
ASME ASME Section IX (2021) - Preparation of welding procedure specification (WPS) as per ASME Section IX |
Preparation of welding procedure specification (WPS) as per ASME Section IX |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| ASME Section IX (Welding procedure Specification) |
10000.0 |
|
|
| 520 |
ASME Section IX (2019) - 2019 Boiler and Pressure Vessel Code |
2019 Boiler and Pressure Vessel Code |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| QW 191 (Radiography Test -Pipe) |
3200.0 |
|
| QW 191 (Radiography Test -Plate) |
1200.0 |
|
|
| 521 |
IS 6012 (1992) - Measurement of coating thickness by eddy current method (First Revision) |
Measurement of coating thickness by eddy current method (First Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| IS 6012 (Coating thickness) |
2000.0 |
|
|
| 522 |
IS 2595 (2008) - Industrial radiographic testing - Code of practice (Second Revision) |
Industrial radiographic testing - Code of practice (Second Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| IS 2595 (Radiography) |
2000.0 |
|
|
| 523 |
IS 5523 (1983) - Methods of testing anodic coatings on aluminium and its alloys (First Revision) |
Methods of testing anodic coatings on aluminium and its alloys (First Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| IS 5523 (Coating thickness) |
2000.0 |
|
|
| 524 |
13683 (2006) - Ring Spun Grey Cotton Yarn |
Ring Spun Grey Cotton Yarn |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
| 525 |
IS 10733 (1983) - Tanker Hose of Rubber |
Tanker Hose of Rubber |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
| 526 |
IS 8329 (2000) - Centrifugally cast (Spun) ductile iron pressure pipes for water, gas and sewage - Specification (Third Revision) |
Centrifugally cast (Spun) ductile iron pressure pipes for water, gas and sewage - Specification (Third Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 15.1.1 (External diameter) |
1000.0 |
|
| 10.1.1 (Tensile Strength) |
2000.0 |
|
| 10.1.1 (Percent Elongation) |
1500.0 |
|
| 10.2 (Brinell Hardness) |
2000.0 |
|
| 16.2 (C-2.3) (Bituminous Coating Test) |
1000.0 |
|
| 15.3 (Ovality of pipe) |
1000.0 |
|
| 16.3 (Thickness of Cement mortar lining of pipe) |
1000.0 |
|
| 13.3 (Wall Thickness of pipe) |
1000.0 |
|
| 13.2 (Bore Clearance of mortar lining in ductile iron pipe) |
1000.0 |
|
|
| 527 |
CBIP 317 (2013) - Central Board of Irrigation & Power-Manual No-317-
Single Phase Transformer |
Central Board of Irrigation & Power-Manual No-317-
Single Phase Transformer |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Sec BB (3) (Magnetic Balance Test) |
2000.0 |
|
| Sec BB (3) (Measurement of unbalanced current) |
2000.0 |
|
| Sec BB (3) (Polarization lndex) |
5000.0 |
|
| Sec BB (3) (Voltage) |
3000.0 |
|
| Sec BB (3) (Unbalanced Current) |
3000.0 |
|
| 17.3.2 (Permanent Deflection) |
10000.0 |
|
| 17.3.1 (Permanent Deflection) |
8000.0 |
|
|
| 528 |
IS 335 (1993) - NEW INSULATING OILS- SPECIFICATION |
NEW INSULATING OILS- SPECIFICATION |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 4.5.2.6 (Measurernent of Break Down Voltage of trransformer Oil) |
10000.0 |
|
|
| 529 |
IS 15652 (2006) - Insulating mats for electrical purposes - Specification |
Insulating mats for electrical purposes - Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 8.2.1 (Insulation Resistance with Water) |
4000.0 |
|
| 8.2.2 (Leakage Current Test) |
2500.0 |
|
| 8.2.3 (AC Dielectric Strength) |
7000.0 |
|
| 8.2.4 (AC Proof Voltage) |
3000.0 |
|
| 6.3 (Thickness) |
500.0 |
|
| 8.4.2 (Low Temperature Resistance & High Voltage test) |
4000.0 |
|
| 8.6 (Extreme low temperature test) |
6000.0 |
|
| 8.1 (Tensile Strength and Elongation at Break) |
1500.0 |
|
| 8.3 (Tensile Strength and Elongation at break
After Ageing) |
4000.0 |
|
| 8.5 (After Acid/Alkalis and Oil Resistance) |
4500.0 |
|
| 8.4.1 (Flame Retardance) |
2000.0 |
|
| 6.2 (Dimensions) |
1000.0 |
|
|
| 530 |
IS 15769 (2008) - Flux Cored (Tubular) Electrodes for Gas Shielded and Self Shielded Metal welding of Carbon or Carbon Manganese Steel |
Flux Cored (Tubular) Electrodes for Gas Shielded and Self Shielded Metal welding of Carbon or Carbon Manganese Steel |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 4.1 (Diameter of Core Wire) |
500.0 |
|
| 4.2 (Temper) |
1000.0 |
|
| 4.2 (Cast) |
500.0 |
|
| 4.2 (Helix) |
500.0 |
|
| 4.3 (Uniformity) |
500.0 |
|
| 4.4.3 (Spools, Overall Diameter A) |
500.0 |
|
| 4.4.3 (Spools, Overall Width, B) |
500.0 |
|
| 4.4.3 (Spools, Inner Diameter, C) |
500.0 |
|
| 4.4.3 (Spools, Distance Between Axes D) |
500.0 |
|
| 4.4.3 (Spools, Driving Hole Diameter E) |
500.0 |
|
| 4.4.3 (Spools, Weight, Max) |
500.0 |
|
| 5.8 (Chemical Analysis) |
5000.0 |
|
| 5.2 (Radiographic Examination) |
1500.0 |
|
| 5.3 (Tensile Test) |
3000.0 |
|
| 5.4 (Charpy Impact Test) |
3000.0 |
|
| 5.1.3.2 (Fillet Weld Fracture) |
4000.0 |
|
| 5.1.3.2 (Dimension of Fillet Weld) |
500.0 |
|
| 5.5 (Transverse Tensile Test) |
3000.0 |
|
| 5.6 (Longitudinal Guided Bend Test) |
1000.0 |
|
| 5.7 (Diffusible Hydrogen Test) |
5000.0 |
|
|
| 531 |
IS 2026 : Part 1 (2011) - Power Transformers: Part 1 General (Second Revision) |
Power Transformers: Part 1 General (Second Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 10.1.2(a) (Temperatur Rise) |
20000.0 |
|
| 10.1.1(a) (Measurement of windlng Resistance) |
1600.0 |
|
| 10.1.1(b) (Voltage ratio & Phase Displacement) |
3200.0 |
|
| 10.1.1 (C) (% impedance and load loss) |
12800.0 |
|
| 10.1.1(d) (No Load loss and current) |
9600.0 |
|
| 10.1.1(e) (Separate source AC voltage withstand test) |
4000.0 |
|
| 10.1.1(e) (Induced Overvoltage) |
6400.0 |
|
| 10.1.2(b) (Lightning lmpulse Voltage test, Chopped
impulse voltage test, Multi chopped irnpulse voltage test) |
500000.0 |
|
| 10.1.3(d) (Measurement of Zero phase sequence impedance for 3
Phase transformer) |
3000.0 |
|
| 10.1.3(g) (% Harmonics) |
10000.0 |
|
| 10.1.3(j) (Measurement of Insulation Resistance) |
2400.0 |
|
| 10.1.3 (f) (Noise Level) |
10000.0 |
|
| 7 (Rating Plate Details) |
- |
|
| 17.3.1 (a) of CBIP Pub. No. 317 (Pressure Test Routine (Deflection)) |
8000.0 |
|
| 17.3.2 (a) of CBIP Pub. No. 317 (Vacuum Test - Type (Deflection)) |
10000.0 |
|
| 17.3.2 (b) of CBIP Pub. No. 317 (Oil Leakage Test (Pressure Test - Type)) |
10000.0 |
|
| As per CBIP No. 317 Cl. 3.10 (Magnetic Balance Test) |
3000.0 |
|
| As per IS : 335 (Breakdown Voltage Test) |
10000.0 |
|
| CBIP Publication no. 317 (Measurement of Unbalance Current) |
5000.0 |
|
| 10.1.2 (b) (Lightning Impulse Voltage Withstand Test upto 11 KV & 500 KVA Rating) |
40000.0 |
|
| 10.1.2 (b) (Lightning Impulse Voltage Withstand Test upto 11 KV & 1000 KVA Rating) |
50000.0 |
|
| 10.1.2 (b) (Lightning Impulse Voltage Withstand Test upto 11 KV & 2500 KVA Rating) |
65000.0 |
|
| 10.1.2 (b) (Lightning Impulse Voltage Withstand Test For Power Transformers of 33 KV Class upto 20 MVA) |
250000.0 |
|
| 10.1.3 (Measurement of Dissipation Factor (Tan Delta) & Capacitance) |
30000.0 |
|
|
| 532 |
IS 2713 : PART 1 TO 3 (1980) - Tubular Steel Poles for Overhead Power Lines |
Tubular Steel Poles for Overhead Power Lines |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 8.4 (Weight of Pole) |
1000.0 |
|
| 15.1 (Dimension of Base Plate) |
1000.0 |
|
| 8.1 (Outside Diameter (Top, Middle , Bottom Section of Pole)) |
3000.0 |
|
| 8.3 (Length (Overall Length, Top, Middle , Bottom Section of Pole)) |
4000.0 |
|
| 8.2 (Thickness (Top, Middle , Bottom Section of Pole)) |
3000.0 |
|
| 8.5 (Straightness) |
1000.0 |
|
| 7 (Freedom from defect) |
1000.0 |
|
| 10.1.3 (Deflection Test) |
1000.0 |
|
| 10.1.4 (Permanent Set Test) |
1500.0 |
|
| 10.1.5 (Drop Test) |
1000.0 |
|
| 6 (Chemical Composition (Top, Middle , Bottom Section of Pole)) |
4500.0 |
|
| 11.2 of IS 1161: 2014 (Tensile Test (Top, Middle , Bottom Section)) |
9000.0 |
|
| 11.3.2 of IS 1161: 2014 (Flattening test (Top, Middle , Bottom Section of Pole)) |
3000.0 |
|
| 13.2 (Protection against corrosion (Galvanized Test)) |
2000.0 |
|
|
| 533 |
2026 (Part-11) (2021) - Specification for dry - Type power transformers |
Specification for dry - Type power transformers |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 13.1.(a) (Measurement of Winding Resistance) |
1000.0 |
|
| 13.1.(b) (Measurement of Voltage ratio & voltage vector relationship test) |
2000.0 |
|
| 13.1.(c) (Measurement of lmpedance Voltage
,Short Circuit lmpedance and Load Loss) |
8000.0 |
|
| 13.1.(d) (Measurement of No Load Loss & Current) |
6000.0 |
|
| 13.1.(e) (Separate source Voltage withstand test) |
2500.0 |
|
| 13.1.(f) (lnduced Over voltage withstand test) |
4000.0 |
|
| 13.1(g) (Lightning Impulse Test) |
65000.0 |
|
| 13.1.(h) (Temperature Rise Test) |
40000.0 |
|
| 13.3.(b) (Measurement of acoustic sound Level) |
7000.0 |
|
|
| 534 |
IS 4454 : Part 1 (2001) - Steel wire for mechanical springs - Specification: Part 1 cold drawn unalloyed steel wire (Third Revision) |
Steel wire for mechanical springs - Specification: Part 1 cold drawn unalloyed steel wire (Third Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 10.1 (Tensile Strength) |
3000.0 |
|
| 9 (Dimensions) |
1000.0 |
|
|
| 535 |
IS 15622 (2017) - Pressed Ceramic Tiles - Specification (First Revision) |
Pressed Ceramic Tiles - Specification (First Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6, Tables 5 to 9, Sl No (iii), (a) (Resistance to staining IS 13630(8)/(7):2019) |
1000.0 |
|
| 6, Tables 5 to 9, Sl No (iii), (b) (Resistance to household chemicals swimming pools, and water cleansers except to cleansing agents containing hydrofluoric acid and its compounds IS 13630(8)/(7):2019) |
1000.0 |
|
| 6, Tables 5 to 9, Sl No (iii), (c) (Resistance to acid and alkalies (with exception of hydrofloric acid and its compounds-IS 13630(8)/(7):2019) |
1000.0 |
|
| 6, Tables 5 to 9, Sl No (i), (f) (Surface Quality-IS13630 (Part1):2019) |
500.0 |
|
| 6, Tables 5 to 9, Sl No (i), (a) (Dimensions-Length-IS13630 (Part1):2019) |
1000.0 |
|
| 6, Tables 5 to 9, Sl No (i), (a) (Dimensions-Width -IS:13630 (Part1):2019) |
1000.0 |
|
| 6, Tables 5 to 9, Sl No (i), (b) (Dimension-Thickness-Deviation in percent from work size -IS: 13630 (Part1):2019) |
1000.0 |
|
| 6, Tables 5 to 9, Sl No (i), (d) (Rectangularity-Maximum deviation in percent to corresponding work size-IS: 13630 (Part1):2019) |
500.0 |
|
| 6, Tables 5 to 9, Sl No (i), (c) (Straightness of sides(Facial sides)Maximum deviation in percent to corresponding work size- IS13630 (Part1):2019) |
500.0 |
|
| 6, Tables 5 to 9, Sl No (i), (e-1,2,3) (Surface Flatness-Maximum deviation in percent from flatness-(Centre curvature, Edge curvature & warpage) -IS: 13630 (Part1):2019) |
500.0 |
|
| 6, Tables 5 to 9, Sl No (ii), (a) (Water Absorption-IS13630 (Part 2):2019) |
1000.0 |
|
| 6, Tables 5 to 9, Sl No (ii), (b) (Modulus of rupture in N/mm²- IS13630 (Part6):2019) |
2000.0 |
|
| 6, Tables 5 to 9, Sl No (ii), (c) (Breaking of strength in N- IS13630 (Part 6):2019) |
2000.0 |
|
| 6, Tables 5 to 9, Sl No (ii), (e) (Scratch Hardness of surface (Mohs' Scale)-IS13630 (Part 13):2019) |
2000.0 |
|
| 6, Tables 5 to 9, Sl No (ii), (j) (Crazing Resistance- IS13630 (Part 9):2019) |
1500.0 |
|
| 6, Tables 5 to 9, Sl No (ii), (k) (Impact resistance-Coefficient of Restitution-IS13630 (Part 14):2019) |
1000.0 |
|
| 6, Tables 8 and 9, Sl No (ii), (q) (Bulk Density-IS13630 (Part 2):2019) |
1000.0 |
|
| 6, Table 9, Sl No (iii), (a, b, c)-1(Part 8) (Chemical properties-glazed- IS13630 (Part 8):2019) |
5000.0 |
|
|
| 536 |
IS 1237 (2012) - Cement Concrete Flooring Tiles - Specification |
Cement Concrete Flooring Tiles - Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 12.6 (Wet transverse strength-Annex F of IS 1237:2012) |
2000.0 |
|
| 12.5 (Water Absorption-Annex E of IS 1237:2012) |
1000.0 |
|
| 12.4 (Straightness-Annex D of IS 1237:2012) |
500.0 |
|
| 12.3 (Perpendicularity-Annex C of IS 1237:2012) |
500.0 |
|
| 10 (General Quality-IS 1237:2012) |
100.0 |
|
| 8.3 & Table2 (The thickness of Wearing Layer-IS 1237:2012) |
100.0 |
|
| 7, 8.2 & Table1 (Thickness & Tolerances-IS 1237:2012) |
100.0 |
|
| 7 & 8.1, Table1 (Dimensions & Tolerances-IS 1237:2012) |
200.0 |
|
| 12.7 (Resistance to wear-Annex G of IS 1237:2012) |
2500.0 |
|
|
| 537 |
IS 10262 (2019) - Concrete Mix Proportioning — Guidelines ( Second Revision ) |
Concrete Mix Proportioning — Guidelines ( Second Revision ) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 4 (Concrete Mix design (IS 10262:2019) with Admixture) |
35000.0 |
|
| 1 (Concrete Mix Proportioning — Guidelines (without admixture)) |
30000.0 |
|
|
| 538 |
IS 1489 : Part 2 (2015) - Portland - Pozzolana cement - Specification: Part 2 calcined clay based |
Portland - Pozzolana cement - Specification: Part 2 calcined clay based |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 7, Table 2, Sl No 6 (Drying Shrinkage IS 4031(10):1988) |
1000.0 |
|
| 7, Table 2, Sl No 4c (28 Days Compressive strength, MPa- IS 4031(6):1988) |
1000.0 |
|
| 7, Table 2, Sl No 4b (7 Days Compressive strength,168±2 h, MPa- IS 4031(6):1988) |
1000.0 |
|
| 7, Table 2, Sl No 4a (3 Days Compressive strength,72±1 , MPa- IS 4031(6):1988) |
1000.0 |
|
| 7, Table 2, Sl No 3b (Setting time-Final, IS 4031(5):1988) |
250.0 |
|
| 7, Table 2, Sl No 3a (Setting time- Initial IS 4031(5):1988) |
250.0 |
|
| 7, Table 2, Sl No 2b (Soundness-autoclave method IS 4032(3):1988) |
1000.0 |
|
| 7, Table 2, Sl No 2a (Soundness-Lechatlier method IS 4032(3):1988) |
500.0 |
|
| 6, Table 1, Sl No 6 (Alkali content IS 4032:1985) |
2000.0 |
|
| 6, Table 1, Sl No 5 (Chloride content IS 4032:1985) |
800.0 |
|
| 6, Table 1, Sl No 4 (Loss on Ignition IS 4032:1985) |
800.0 |
|
| 6, Table 1, Sl No 3 (Total Sulphur content IS 4032:1985) |
800.0 |
|
| 6, Table 1, Sl No 2 (Magnesia IS 4032:1985) |
800.0 |
|
| 6, Table 1, Sl No 1 (Insoluble residue IS 4032:1985) |
800.0 |
|
|
| 539 |
IS 16227 : Part 1 (2016) - Instrument transformers: Part 1 general requirements |
Instrument transformers: Part 1 general requirements |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 7.2.3.2 (Multi chopped (100) Lightning Impulse Voltage Test (CT / PT ) 220 KV Class) |
150000.0 |
|
| 7.2.3.2 (Multi chopped (100) Lightning Impulse Voltage Test (CT / PT ) 132 KV Class) |
100000.0 |
|
|
| 540 |
IS 1489 (Part 1) (2015) - Portland pozzolana cement - Specification: Part 1 Fly Ash Based |
Portland pozzolana cement - Specification: Part 1 Fly Ash Based |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 7, Table 2, Sl No 1 (Fineness IS 4031(2):1999) |
1000.0 |
|
| 7, Table 2, Sl No 6 (Drying Shrinkage IS 4031(10):1988) |
1000.0 |
|
| 7, Table 2, Sl No 4c (28 Days Compressive strength, IS 4031(6):1988) |
1000.0 |
|
| 7, Table 2, Sl No 4b (7 Days Compressive strength, IS 4031(6):1988) |
1000.0 |
|
| 7, Table 2, Sl No 4a (3 Days Compressive strength, IS 4031(6):1988) |
1000.0 |
|
| 7, Table 2, Sl No 3b (Setting time-Final IS 4031(5):1988) |
250.0 |
|
| 7, Table 2, Sl No 3a (Setting time-Initial IS 4031(5):1988) |
250.0 |
|
| 7, Table 2, Sl No 2b (Soundness-autoclave method IS 4031(3):1988) |
1000.0 |
|
| 7, Table 2, Sl No 2a (Soundness-Lechatlier method IS 4031(3):1988) |
500.0 |
|
| 6, Table 1, Sl No 6 (Alkali content IS 4032:1985) |
2000.0 |
|
| 6, Table 1, Sl No 5 (Chloride content, IS 4032:1985) |
800.0 |
|
| 6, Table 1, Sl No 4 (Loss on ignition IS 4032:1985) |
800.0 |
|
| 6, Table 1, Sl No 3 (Total Sulphur content IS 4032:1985) |
800.0 |
|
| 6, Table 1, Sl No 2 (Magnesia IS 4032:1985) |
600.0 |
|
| 6, Table 1, Sl No 1 (Insoluble residue, IS 4032:1985) |
600.0 |
|
| 13 (Consistency of Cement) |
500.0 |
|
|