91 |
IS 12037 (1987) - Specification for macrographic examination of steel by sulphur print (Baumann Method) |
Specification for macrographic examination of steel by sulphur print (Baumann Method) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
IS 12037 (Sulphur Print) |
3000.0 |
|
|
92 |
IS 11802 (1986) - Methods for determination of diffusible hydrogen content of deposited weld metal from covered electrodes in welding mild and low alloy steels |
Methods for determination of diffusible hydrogen content of deposited weld metal from covered electrodes in welding mild and low alloy steels |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
5 (Volume of diffusible hydrogen) |
5000.0 |
|
|
93 |
RDSO STR No. C-K105 (Rev. 1) (2014) - Schedule of Technical Requirements for Bolster Suspension Hangers of BG & MG Mainline and EMU/DMU/MEMU Coaches |
Schedule of Technical Requirements for Bolster Suspension Hangers of BG & MG Mainline and EMU/DMU/MEMU Coaches |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
94 |
ND Custom 10 (2024) - Load Bearing Capacity for RCPC Slabs |
Load Bearing Capacity for RCPC Slabs |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
Firm's Requirement (Load Bearing Capacity Test) |
3000.0 |
|
|
95 |
IS 12889 (2018) - Performance evaluation of materials used for liquid penetrant test (First Revision) |
Performance evaluation of materials used for liquid penetrant test (First Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
12.2 (SYSTEM SENSITIVITY PERFORMANCE) |
10000.0 |
|
|
96 |
IS 9000 Part 4 (2008) - BASIC ENVIRONMENTAL TESTING PROCEDURES FOR ELECTRONIC AND ELECTRICAL ITEMS PART4 DAMP HEAT(STEADY STATE) |
BASIC ENVIRONMENTAL TESTING PROCEDURES FOR ELECTRONIC AND ELECTRICAL ITEMS PART4 DAMP HEAT(STEADY STATE) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
Cl.4 (Damp Heat (Steady State)) |
20000.0 |
|
|
97 |
IS 13252 (2010) - Information Technology Equipments, Class I Product |
Information Technology Equipments, Class I Product |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
2.1.1.6 (Manual Controls) |
2000.0 |
|
2.3.3 (Separations from Hazardous Voltages) |
1000.0 |
|
2.5 (Limited Power Source) |
1000.0 |
|
2.6 (Protective earthing Conductors and protective bonding Conductors) |
2000.0 |
|
2.7 (Over Current and earth fault protection primary Circuit) |
1000.0 |
|
2.8 (Protection requirements for safety interlocks) |
500.0 |
|
2.9 (Humidity Condition) |
10000.0 |
|
2.10.2 (Determination of Working Voltage) |
1000.0 |
|
3 (Wiring Connection and Supplies) |
1000.0 |
|
4.2.1,4.2.2,4.2.3,4.2.4 (Steady force Test) |
1000.0 |
|
4.2.5 (Impact Test Apparatus) |
500.0 |
|
4.2.6 (Drop Test) |
1000.0 |
|
4.2.7 (Stress Relief Test) |
1000.0 |
|
4.3.1 (Edges and corners) |
500.0 |
|
4.3.4 (Securing of Parts) |
500.0 |
|
4.3.6 (Direct Plug in Equipment) |
1000.0 |
|
4.3.8 (Batteries) |
1000.0 |
|
4.3.9 (Oil & Grease) |
500.0 |
|
4.4.2 (Protected in operator access area) |
1000.0 |
|
4.4.3 (Protected in restricted access Location) |
1000.0 |
|
4.4.4 (Protected in service access Location) |
1000.0 |
|
4.5.2. (Temperature Test) |
1000.0 |
|
4.5.3. (Temperature Limits for Materials) |
2000.0 |
|
4.5.4. (Touch Temperature Limits) |
1000.0 |
|
4.5.5. (Resistance to abnormal Heat) |
2000.0 |
|
4.6.3,4.6.4,4.6.4.1,4.6.4.2,4.6.4.3 (Top, Bottom and Side Opening) |
500.0 |
|
4.6.5 (Adhesives for Constructional Purposes) |
500.0 |
|
5.2 (Electric Strength) |
5000.0 |
|
6.1.1,6.1.2 (Protection of Telecommunication network service person and user to network Protection from Hazardous Voltages) |
1000.0 |
|
6.2.1 (Protection of equipments user from overvoltage on Telecommunication network) |
1000.0 |
|
6.2.2 (Electrical Strength Test) |
2000.0 |
|
7.2 (Protection of cable distribution system service persons and user of other equipment connected to the system from hazardous voltage in the equipment) |
2000.0 |
|
7.3 (Protection of equipment user from over voltages on the cable distribution) |
1000.0 |
|
|
98 |
RDSO/PE/SPEC/AC/0009-2021 (Rev-3) - Specification for Valve Regulated Lead Acid Batteries for 110V Train lighting, Air Conditioned coaches and three phase EMU/MEMU & Metro Rakes |
Specification for Valve Regulated Lead Acid Batteries for 110V Train lighting, Air Conditioned coaches and three phase EMU/MEMU & Metro Rakes |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
6 & 10 (Dimensions,mass, marking and workmanship) |
2500.0 |
|
8.1 (Capacity at 10 hrs rate) |
40000.0 |
|
8.2 (Capacity at 5 hrs rate) |
10000.0 |
|
8.3 (Capacity at 3 hrs rate) |
10000.0 |
|
8.4 (Watt hour and Ampere hour Efficiency test) |
20000.0 |
|
8.5 (Retention of charge and storage test) |
10000.0 |
|
8.6 (Life Test) |
100000.0 |
|
8.7 (Recharge capability test) |
15000.0 |
|
8.8 (Loss of weight test) |
5000.0 |
|
8.9 (Equilibrium Float Current test) |
9999.0 |
|
8.10 (Permissible discharge current test) |
10000.0 |
|
8.11 (Gas Recombination efficiency test) |
5000.0 |
|
8.12 (Verification of material and component test (As per Customer's declaration)) |
1000.0 |
|
8.15 (Air pressure test) |
10000.0 |
|
8.16 (Vibration test) |
10000.0 |
|
8.17 (Internal Resistance test) |
5000.0 |
|
8.18 (Capacity (C10) at zero degree test) |
15000.0 |
|
|
99 |
IS 1145 -1980 (Reaffirmed 2003) - SPECIFICATION FOR LEAD-ACID STORAGE BATTERIES FOR MOTOR CYCLES, AUTORICKSHAWS AND SIMILAR VEHICLES |
SPECIFICATION FOR LEAD-ACID STORAGE BATTERIES FOR MOTOR CYCLES, AUTORICKSHAWS AND SIMILAR VEHICLES |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
7.8 (Dimension) |
1000.0 |
|
7.6 (Physical Examination) |
1000.0 |
|
7.9 (Air Pressure Test) |
10000.0 |
|
7.12 (High Rate Discharge Test) |
15000.0 |
|
7.15 (Life Test) |
20000.0 |
|
7.14 (Resistance to Overcharge Test) |
5000.0 |
|
7.13 (Retention of Charge Test) |
5000.0 |
|
7.10 (Test for Capacity) |
20000.0 |
|
7.11 (Vibration Test) |
10000.0 |
|
7.16 or 7.17 (Storage Test) |
15000.0 |
|
|
100 |
IRS : TC 30-05 - UNDERGROUND RAILWAY JELLY FILLED QUAD CABLES FOR SIGNALLING AND TELECOM INSTALLATIONS |
UNDERGROUND RAILWAY JELLY FILLED QUAD CABLES FOR SIGNALLING AND TELECOM INSTALLATIONS |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
3.11 (Visual Inspection and Marking) |
100.0 |
|
3.12 (Visual Inspection and Marking) |
100.0 |
|
5.9.1 (HV Test to be carried out) |
2000.0 |
|
5.9.2 (Insulation resistance Test) |
1000.0 |
|
5.9.3 (Conductor Resistance Test) |
1.0 |
|
5.6.3.1 (Mass of Zinc Coating test) |
3000.0 |
|
5.8.2.3 (Shrinkage Test of PE Insulation) |
1000.0 |
|
5.8.2.2 (Shrinkage Test of PVC Sheaths) |
1000.0 |
|
|
101 |
NFC-33 041 (1998) - Insulated cables and their accessories for power systems
Anchoring devices for overhead distribution with bundle assembled cores of rated voltage of 0.6/1 kV |
Insulated cables and their accessories for power systems
Anchoring devices for overhead distribution with bundle assembled cores of rated voltage of 0.6/1 kV |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
- (High Voltage Test) |
5000.0 |
|
- (Dimension test) |
1000.0 |
|
|
102 |
NFC-33 040 (1988) - Insulated cables and their accessories for power systems
Suspension equipments for overhead distribution with bundle assembled cores of rated voltage 0.6/1 kV |
Insulated cables and their accessories for power systems
Suspension equipments for overhead distribution with bundle assembled cores of rated voltage 0.6/1 kV |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
- (High Voltage Test) |
5000.0 |
|
- (Dimension Test) |
1000.0 |
|
13 (Mass in kg/10 Liters) |
5.0 |
|
|
103 |
ELRS /SPEC/ SI /0015 (2001) - SPECIFICATION FOR RELIABILITY OF ELECTRONICS USED IN ROLLING STOCK APPLICATION |
SPECIFICATION FOR RELIABILITY OF ELECTRONICS USED IN ROLLING STOCK APPLICATION |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
7.7 & Annexure-1 (Burn – in test) |
20000.0 |
|
|
104 |
IS 9857:1990 (1990) - Welding Cable Specification |
Welding Cable Specification |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
10.1.a.2 (Test on Conductor- Conductor Resistance Test) |
2500.0 |
|
10.1.b (Test for thickness of Covering) |
1500.0 |
|
10.1.d (High Voltage Test (Water Immersion Test)) |
3500.0 |
|
|
105 |
IS 613 (2000) - Copper Rods and Bars for Electrical Purposes |
Copper Rods and Bars for Electrical Purposes |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
5.4 (Resistance of a Solid Conductor) |
5000.0 |
|
6 (Freedom from defects) |
1000.0 |
|
9.1 (Tensile Strength) |
2000.0 |
|
9.1 (Elongation) |
1000.0 |
|
9 (Vickers Hardness) |
2000.0 |
|
9.2 (Bend Test) |
1000.0 |
|
10 (Dimensions) |
1000.0 |
|
11 (Electrical Resistivity Test) |
2000.0 |
|
|
106 |
Climatic Ageing Test (Dry Heat Test) as per IS 9000 (Part-III/Sec-2) :1977 & Customer Specification - Climatic Ageing Test (Dry Heat Test) as per IS 9000 (Part-III/Sec-2) :1977 & Customer Specification |
Climatic Ageing Test (Dry Heat Test) as per IS 9000 (Part-III/Sec-2) :1977 & Customer Specification |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
- (Climatic Ageing Test (Dry Heat Test) as per IS 9000 (Part-III/Sec-2) -1977) |
20000.0 |
|
|
107 |
IEC 61439-1: 2009 & IS/IEC:60529-2001 - IP-65 Class of protection test
Drawing Verification
Power Frequency Voltage withstand test before and after IP test
Dielectric Properties test before and after IP test |
IP-65 Class of protection test
Drawing Verification
Power Frequency Voltage withstand test before and after IP test
Dielectric Properties test before and after IP test |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (IP-65 Class of Protection test) |
15000.0 |
|
2 (Drawing verification) |
3000.0 |
|
3 (Power frequency voltage withstand test) |
5000.0 |
|
4 (Di-electric properties test) |
5000.0 |
|
9.1(iii), sub clause 5.2,7.3 ((i) Rated Voltage at input terminals of current regulated.
(ii) Current at rated voltage per unit at input terminals of current regulates.
(iii) illumination Measured at 1.5 meter from LED signal lighting unit axial direction at rated voltage.
(iv) Colour) |
15000.0 |
|
9.1(xiii) (Insulation Resistance Test before and after high Voltage test as per specification) |
9000.0 |
|
9.2 (Temperature Rise Test) |
20000.0 |
|
|
108 |
IS/IEC:60529-2001 & IEC 61439-1: 2009 - IP-42 Class of protection test
Drawing Verification
Power Frequency Voltage withstand test after IP test
Dielectric Properties test after IP test |
IP-42 Class of protection test
Drawing Verification
Power Frequency Voltage withstand test after IP test
Dielectric Properties test after IP test |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (IP-42 Class of protection test) |
15000.0 |
|
2 (Drawing verification) |
3000.0 |
|
3 (Power Frequency voltage withstand test) |
2500.0 |
|
4 (Di-electric Properties test) |
5000.0 |
|
|
109 |
RDSO/2008/EL/SPEC/0069, Rev. 1 - Technical Specification for roof mounted forced cooled dynamic braking resistors with DC Motor driven cooling blowers for AC Electric LOcomotives. |
Technical Specification for roof mounted forced cooled dynamic braking resistors with DC Motor driven cooling blowers for AC Electric LOcomotives. |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
20 (Hygroscopic Test) |
10000.0 |
|
|
110 |
RDSO/PE/SPEC/TL/0091-2016(Rev-1) (2016) - SPECIFICATION FOR ENERGY EFFICIENT LED BASED LUMINAIRE
UNITS FOR PASSENGER COACHES |
SPECIFICATION FOR ENERGY EFFICIENT LED BASED LUMINAIRE
UNITS FOR PASSENGER COACHES |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
111 |
RDSO Specification no. ETI/PSI/29(12/79) (1979) - Low Tension Distribution Panel for Railway AC Traction Sub-Station. |
Low Tension Distribution Panel for Railway AC Traction Sub-Station. |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
6.2(i) (Checking the wiring for correctness and continuity.) |
5000.0 |
|
6.2(ii) (Voltage test on the panels & the wiring for withstand voltage of 2000V(r.m.s) to earth for 1 minute.) |
10000.0 |
|
6.2(iii) (Insulation Resistance of the complete wiring) |
10000.0 |
|
|
112 |
IEC:62561-7 (2011) - Lightning protection system components - Part 7: Requirements for earthing enhancing Compound. |
Lightning protection system components - Part 7: Requirements for earthing enhancing Compound. |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
5.4 (Determination of Resistivity) |
20000.0 |
|
|
113 |
CQA(HV)/QAI/66/001/ELECTROMAGNET (1989) - Quality Assurance Instruction for Electromagnet |
Quality Assurance Instruction for Electromagnet |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
12.5.2 (Insulation Resistance Test) |
6000.0 |
|
12.5.5 (Moisture Resistance Test) |
30000.0 |
|
12.5.6 (Cold Resistance Test) |
10000.0 |
|
12.5.7 (Thermal Stability Test) |
10000.0 |
|
12.5.9 (Frost & Dew Resistance Test) |
10000.0 |
|
12.5.12 (Vibration Strength Test) |
10000.0 |
|
|
114 |
8623-1:(1993) - Low-Voltage Switchgear and Control gear Assemblies, Part 1: Requirements for Type-Tested and
Partially Type-Tested Assemblies [ETD 7: Low Voltage Switchgear and Control gear] |
Low-Voltage Switchgear and Control gear Assemblies, Part 1: Requirements for Type-Tested and
Partially Type-Tested Assemblies [ETD 7: Low Voltage Switchgear and Control gear] |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
8.2.2 (Verification of dielectric properties) |
10000.0 |
|
8.3.4 (Verification of insulation resistance) |
10000.0 |
|
8.2.1.3 (Tempreture rise test) |
20000.0 |
|
|
115 |
IS/IEC60947-1 - Low-voltage switchgear and control gear - Part 1: General rules |
Low-voltage switchgear and control gear - Part 1: General rules |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
6 (Degree of protection against ingress of water indicated by the second characteristic numeral 6 of IS/IEC 60529 clause 14.2.6) |
7500.0 |
|
10 (Marking) |
- |
|
Clause :7 (Degrees of protection against action to access to hazards parts indicated by the additional letter, Cl 14.2.7 of IS/IEC 60529) |
7500.0 |
|
13.2 (First Characteristic Numeral 1 (Protection against solid foreign objects of 50 mm dia and greater)) |
7500.0 |
|
13.2 (First Characteristic Numeral 2 (Protection against solid foreign objects of 12.5 mm dia and greater)as per IS/IEC60529)) |
7500.0 |
|
13.2 First Characteristic Numeral 3 (Protection against solid foreign object 2.5 mm diameter and greater as per IS/IEC 60529) |
7500.0 |
|
13.2 First Characteristic Numeral 4 (Protection against solid foreign objects of 1.0 mm diameter and great as per IS/IEC 60529) |
7500.0 |
|
13.4 Dust Test (Dust Protected , Category 1 as per IS/IEC 60529(reductions in air pressure with in the enclosure below that of the surrounding air.)) |
7500.0 |
|
13.5 Dust Test, Category 2 (Dust Protected , Category 2 as per IS/IEC 60529(no pressure difference relative to the surrounding air is
present..)) |
7500.0 |
|
13.5/13.6 (Dust Tight as per IS/IEC 60529) |
7500.0 |
|
14.2.1 Second Characteristic numeral 1 (Protection against vertically falling water drops as per IS IEC 60529) |
7500.0 |
|
14.2.2 Second characteristics numeral 2 (Protected against vertically falling water drops when enclosure tilted upto 15 degree) |
7500.0 |
|
14.2.3 second characteristic numeral 3 (Protection against spraying water as per IS /IEC 60529) |
7500.0 |
|
14.2.4 Second characteristic numeral 4 (Protected against splashing water as per IS/IEC 60529) |
7500.0 |
|
14.2.5 Second characteristic numeral 5 (Protected against water jet as per IS/IEC 60529) |
7500.0 |
|
14.2.6 Second characteristic numeral 6 (Protected against powerful water jet as per IS/IEC 60529) |
7500.0 |
|
14.2.7, Second characteristic numeral 7 (Protection against temporary immersion of water as per IS/IEC 60529) |
7500.0 |
|
14.2.8, Second Characteristic numeral 8 (Protection against the effects of continuous immersion in water as per IS/IEC 60529) |
7500.0 |
|
14.2.8, Second Characteristic numeral 8 (Protection against the effects of continuous immersion in water as per IS/IEC 60529) |
7500.0 |
|
|
116 |
IEC 61427-1: 2013 (2013) - Secondary cells and batteries for renewable energy storage - General requirements and methods of test-
Part 1: Photovoltaic off-grid application |
Secondary cells and batteries for renewable energy storage - General requirements and methods of test-
Part 1: Photovoltaic off-grid application |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
8.1 (Capacity Test) |
60000.0 |
|
8.3 (Charge retension test) |
25000.0 |
|
8.4 (Cycling endurance test in photovoltaic applications(extreme conditions)) |
70000.0 |
|
|
117 |
CQAL/637 :2006 - SPECIFICATION FOR BATTERY SECONDARY, LEAD ACID, LOW MAINTENANCE FOR MT PURPOSES |
SPECIFICATION FOR BATTERY SECONDARY, LEAD ACID, LOW MAINTENANCE FOR MT PURPOSES |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
15.1 (Visual Examination) |
1000.0 |
|
15.2 (Physical Examination) |
1000.0 |
|
15.3 (Dimensions and Layout) |
1000.0 |
|
15.4 (Marking) |
1000.0 |
|
15.5 (Capacity (5-h rate)) |
5000.0 |
|
15.6.1 (High Rate Discharge at -15 degree C) |
10000.0 |
|
15.6.3 (High Rate Discharge at Normal Temperature) |
15000.0 |
|
15.7 (Robustness of Handle) |
5000.0 |
|
15.8 (Charge Acceptance) |
15000.0 |
|
15.9 (Air Pressure Test) |
10000.0 |
|
15.10 (Life Cycle test) |
100000.0 |
|
15.11 (Vibration Resistance) |
10000.0 |
|
15.12 (Over Charge Endurance) |
20000.0 |
|
15.13 (Strength of Terminal) |
5000.0 |
|
15.14 (Robustness to Fastening) |
5000.0 |
|
15.15 (Test for Dry Charged Battery) |
10000.0 |
|
15.16 (High Voltage Test) |
5000.0 |
|
15.17 (Retention of Charge) |
15000.0 |
|
15.18 (Electrolyte Retention test) |
5000.0 |
|
16.1 (Reserve Capacity Test) |
20000.0 |
|
16.2 (Cold Cranking Performance test at -18 Degree C) |
15000.0 |
|
16.3 (Water Consumption Test) |
10000.0 |
|
|
118 |
IS 11371 (1985) - Method for macroetch test of wrought steel products |
Method for macroetch test of wrought steel products |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
IS 11371 (Macro Etch Examination) |
1000.0 |
|
|
119 |
IS 5154-Part 1- 2013 (2013) - LEAD-ACID TRACTION BATTERIES
PART 1 GENERAL REQUIREMENTS AND METHODS OF TEST
[ Bag plate Lead Acid Secondary Battery) |
LEAD-ACID TRACTION BATTERIES
PART 1 GENERAL REQUIREMENTS AND METHODS OF TEST
[ Bag plate Lead Acid Secondary Battery) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
6.1 (Energy Density Test) |
5000.0 |
|
|
120 |
IS 1182 (1983) - Recommended - Practice for radiographic examination of fusion welded butt joints in steel plates (Second Revision) |
Recommended - Practice for radiographic examination of fusion welded butt joints in steel plates (Second Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|