| 1 |
IS 398 : Part 5 (1992) - Aluminium conductor for overhead transmission purposes - Specification: Part 5 aluminium conductors - Galvanized steel - Reinforced for extra high voltage (400 KV And Above) (First Revision) |
Aluminium conductor for overhead transmission purposes - Specification: Part 5 aluminium conductors - Galvanized steel - Reinforced for extra high voltage (400 KV And Above) (First Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 13.3 (Measurement of Diameters of Individual Aluminium and Steel Wires) |
1000.0 |
|
| 13.4 (Measurement of Lay Ratio) |
2000.0 |
|
| 13.5.2 (Breaking Load Test on Individual Wires) |
3500.0 |
|
| 13.6 (Ductility Test) |
3500.0 |
|
| 13.7 (Wrapping Test) |
1000.0 |
|
| 13.8 (Resistance Test) |
5000.0 |
|
| 13.9 (Galvanizing Test) |
2000.0 |
|
|
| 2 |
IS 398 : Part 4 (1994) - Aluminium conductors for overhead transmission purposes: Part 4 aluminium alloy stranded conductors (Aluminium - Magnesium - Silicon Type) - Specification (Third Revision) |
Aluminium conductors for overhead transmission purposes: Part 4 aluminium alloy stranded conductors (Aluminium - Magnesium - Silicon Type) - Specification (Third Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 12.2 (Breaking load test of individual Aluminium Alloy wire (7 wire construction)) |
1000.0 |
|
| 12.3 (Elongation test of Aluminium Alloy wire(7 wire construction)) |
1000.0 |
|
| 12.4 (Resistance test of Aluminium Alloy wire(7 wire construction)) |
1000.0 |
|
| 12.2 (Breaking load test of individual Aluminium Alloy wire (19 wire construction)) |
2000.0 |
|
| 12.3 (Elongation test of Aluminium Alloy wire(19 wire construction)) |
2000.0 |
|
| 12.4 (Resistance test of Aluminium Alloy wire (19 wire construction)) |
2000.0 |
|
| 7.2.1 (Measurement of diameter of Aluminium Alloy wire(7 wire construction)) |
1000.0 |
|
| 7.2.1 (Measurement of diameter of Aluminium Alloy wire(19 wire construction)) |
2000.0 |
|
| 9.2 (Measurement of lay ratio (7 wire construction)) |
1000.0 |
|
| 9.2(1) (Measurement of lay ratio-Inner layer(19 wire construction)) |
1000.0 |
|
| 9.2(2) (Measurement of lay ratio - Outer layer(19 wire construction)) |
1000.0 |
|
|
| 3 |
IS 398 : Part 2 (1996) - Aluminium conductors for overhead transmission purposes - Specification: Part 2 aluminium conuuctors, galvanized steel - Reinforced (Third Revision) |
Aluminium conductors for overhead transmission purposes - Specification: Part 2 aluminium conuuctors, galvanized steel - Reinforced (Third Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 13.8(3) (Measurement of lay ratio-Outermost layer (30 or 54 wire construction)) |
1000.0 |
|
| 13.2 (Measurement of diameter of individual Aluminium wires (7 wire construction)) |
1000.0 |
|
| 13.8 (Measurement of lay ratio(7 wire construction)) |
2000.0 |
|
| 13.3 (Breaking load of individual Aluminium wires (7 wire construction)) |
3500.0 |
|
| 13.4.1 (Ductility test-Torsion test on steel wires (7 Wire construction)) |
3500.0 |
|
| 13.5 (Wrapping test on Aluminium and Steel wires (7 wire construction)) |
1000.0 |
|
| 13.6 (Resistance of Aluminium wire (7 wire construction)) |
5000.0 |
|
| 13.7(1) (Galvanizing test-Mass of zinc coating(7wire construction)) |
2000.0 |
|
| 13.2 (Measurement of diameter of individual Aluminium wires (30 or 54 Wire construction)) |
1000.0 |
|
| 13.8(1) (Measurement of lay ratio - steel core (30 or 54 wire construction)) |
1000.0 |
|
| 13.3 (Breaking load of individual Aluminium wires (30 or 54 Wire construction)) |
1500.0 |
|
| 13.4.1 (Ductility lest-Torsion test on steel wires (30 or 54 Wire construction)) |
1000.0 |
|
| 13.5 (Wrapping test on Aluminium and Steel wires (30 or 54 Wire construction)) |
1000.0 |
|
| 13.6 (Conductor Resistance test (30 or 54 Wire construction)) |
1000.0 |
|
| 13.7(1) (Galvanizing test-Mass of Zing coating(30 or 54 wire construction)) |
1000.0 |
|
| 13.2(1) (Measurement of diameter of individual steel wire(30 or 54 Wire construction)) |
1000.0 |
|
| 13.3(1) (Breaking load of individual steel wires(30 or 54 wire construction)) |
1500.0 |
|
| 13.4.2 (Ductility test-Elongation test on steel wires (7 Wire construction)) |
3500.0 |
|
| 13.7(2) (Galvanizing - Uniformity of Zinc coating test (7 wire construction)) |
2000.0 |
|
| 13.8(2) (Measurement of Lay ratio-Layer immediately beneath the outer most layer(30 or 54 wire construction)) |
1000.0 |
|
| 13.6 (Resistance Test as per Clause 13.6 (Table 1) in Ohms/km) |
3000.0 |
|
| 13.9 (d. c. Resistance test) |
2000.0 |
|
|
| 4 |
IS 398 : Part 1 (1996) - Aluminium conductors for overhead transmission purposes - Specification: Part 1 aluminium stranded conductors (Third Revision) |
Aluminium conductors for overhead transmission purposes - Specification: Part 1 aluminium stranded conductors (Third Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 12.2 (Measurement of diameter of Aluminium wire(7 wire construction)) |
1000.0 |
|
| 12.6(2) (Measurement of lay ratio-Outer layer(19 wire construction)) |
1500.0 |
|
| 12.3 (Breaking load test of individual Aluminium(7 wire construction)) |
1000.0 |
|
| 12.4 (Wrapping test of Aluminium wire (7 wire construction)) |
1000.0 |
|
| 12.5 (Resistance test of Aluminium wire(7 wire construction)) |
1000.0 |
|
| 12.6 (Measurement of lay ratio (7 wire construction)) |
1000.0 |
|
| 12.2 (Measurement of diameter of Aluminium wire(19 wire construction)) |
3000.0 |
|
| 12.3 (Breaking load test of individual Aluminium (19 wire construction)) |
3000.0 |
|
| 12.4 (Wrapping test of Aluminium wire(19 wire construction)) |
3000.0 |
|
| 12.5 (Resistance test of Aluminium wire(19 wire construction)) |
3000.0 |
|
| 12.6(1) (Measurement of lay ratio-Inner layer(19 wire construction)) |
1500.0 |
|
| 9 (Construction(7 or 19 wire construction)) |
- |
|
| 11 (Markings (7 or 19 wire construction)) |
- |
|
|
| 5 |
NTH_CUSTOM/2026/033 - INDIAN RAILWAYS STANDARD SPECIFICATION FOR CLASSIFICATION, TESTING AND ACCEPTANCE CRITERIA OF FILLER WIRES FOR MIG/MAG WELDING |
INDIAN RAILWAYS STANDARD SPECIFICATION FOR CLASSIFICATION, TESTING AND ACCEPTANCE CRITERIA OF FILLER WIRES FOR MIG/MAG WELDING |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6.2.1 A1 (Welding Performance) |
2000.0 |
|
| 6.2.1 A2 (Accelerated Storage Stability Test) |
3000.0 |
|
| 6.2.2 (Copper Coating) |
1000.0 |
|
| 6.2.3 (Cast and Helix) |
1000.0 |
|
| 6.2.4 (Preparation of weld assembly) |
5000.0 |
|
| 6.2.4 (UTS) |
1000.0 |
|
| 6.2.4 (YS) |
1000.0 |
|
| 6.2.4 (% Elongation) |
500.0 |
|
| 6.2.4 (% Reduction in area) |
500.0 |
|
| 6.2.5 (Carbon) |
500.0 |
|
| 6.2.5 (Manganese) |
500.0 |
|
| 6.2.5 (Silicon) |
500.0 |
|
| 6.2.5 (Sulphur) |
500.0 |
|
| 6.2.5 (Phosphorus) |
500.0 |
|
| 6.2.5 (Molybdenum) |
500.0 |
|
| 6.2.5 (Nickel) |
500.0 |
|
| 6.2.5 (Copper) |
500.0 |
|
| 6.2.5 (Chromium) |
500.0 |
|
| 6.2.5 (Vanadium) |
500.0 |
|
| 6.2.6 (Radiography) |
1500.0 |
|
| 6.2.7 (Hydrogen Content) |
5000.0 |
|
| 6.2.8 (Hardness Survey) |
1000.0 |
|
| 6.2.9 (Macro Examination) |
1000.0 |
|
| 6.2.10 (Fillet Weld Test) |
3000.0 |
|
| 6.2.11 (Corrosion resistance test) |
5000.0 |
|
| 6.2.12 (Charpy Impact Test) |
3000.0 |
|
| 8 (Shelf Life) |
1000.0 |
|
|
| 6 |
# IS 15041d (2025) - TEXTILES - FLAT WOVEN WEBBING SLINGS MADE FROM MANMADE FIBRES FOR GENERAL SERVICES - SPECIFICATION (FIRST REVISION) |
TEXTILES - FLAT WOVEN WEBBING SLINGS MADE FROM MANMADE FIBRES FOR GENERAL SERVICES - SPECIFICATION (FIRST REVISION) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5.5 (Working load limit) |
10000.0 |
|
| 5.6 (Maximum safe working load) |
3000.0 |
|
| 5.7 (Safety factor / tensile test) |
3000.0 |
|
| 5.8 (Proof load testing) |
3000.0 |
|
| 5.5 (Working Load Limit(WLL)) |
6000.0 |
|
| 5.6 (Maximum safe working) |
6000.0 |
|
| 5.7 (Safety Factor/ Tensile Test) |
6000.0 |
|
| 5.8 (Proof load testing) |
6000.0 |
|
| 5.5 (Working Load Limit(WLL)) |
8000.0 |
|
| 5.6 (Maximum safe working load) |
8000.0 |
|
| 5.7 (Safety Factor / Tensile Test) |
8000.0 |
|
| 5.8 (Proof Load Testing) |
8000.0 |
|
| 5.5 (Working Load Limit) |
10000.0 |
|
| 5.6 (Maximum Safe Working Load) |
10000.0 |
|
| 5.7 (Safety Factor/ Tensile Test) |
10000.0 |
|
| 5.8 (Proof Load Testing) |
10000.0 |
|
|
| 7 |
ICF/MD/SPEC-091 ISSUE STATUS : 01 REV.N0 : 02 - SPECIFICATION FOR POWDER COATED ITEMS/ COMPONENTS USED IN RAILWAY PASSENGER COACHES |
SPECIFICATION FOR POWDER COATED ITEMS/ COMPONENTS USED IN RAILWAY PASSENGER COACHES |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6.0 Type Test SR No. 5 (Dry Film Thickness) |
1200.0 |
|
| 6.0 Type Test SR No. 6 (Gloss at 60 degrees) |
1200.0 |
|
| 6.0 Type Test SR No. 8 (Scratch Hardness) |
1200.0 |
|
| 6.0 Type test SR No. 7 (Finish) |
1200.0 |
|
| 6.0 TYPE TEST sr no 1 (Protection against corrosion FOR 100 HOURS
IS:101 (Part-6-Sec.1 )) |
5000.0 |
|
| 6.0 TYPE TEST:SR No 2 (Protection against humidity
IS:101 (Part 6/sec1)) |
2500.0 |
|
| 6.0 Type Test SR No 3 (Resistance to Heat double-bake schedule 16 hrs
IS: 101 (Part-7/Sec.3) as per Clause 8 and
8.1.1 restricted to250degC) |
2500.0 |
|
| 6.0 Type test SR No 4 (Colour Fastness to light(100 hours)
As per clause D 3.2.3 of1S:8662 & IS: 133 Sl.N0.V11 Table.l Apparatus: Xenon Arc accelerated weatherometer in the region of 280-315nm) |
5000.0 |
|
|
| 8 |
# ND CUSTOM 14 (2026) - Cable Gripper |
Cable Gripper |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Slip/Grip Test) |
8000.0 |
|
|
| 9 |
IS 15769 (2008) - Flux Cored (Tubular) Electrodes for Gas Shielded and Self Shielded Metal welding of Carbon or Carbon Manganese Steel |
Flux Cored (Tubular) Electrodes for Gas Shielded and Self Shielded Metal welding of Carbon or Carbon Manganese Steel |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5.2 (Radiographic Examination) |
1500.0 |
|
| 5.3 (Tensile Test) |
3000.0 |
|
| 5.4 (Charpy Impact Test) |
3000.0 |
|
| 5.5 (Transverse Tensile Test) |
3000.0 |
|
| 5.6 (Longitudinal Guided Bend Test) |
1000.0 |
|
| 5.7 (Diffusible Hydrogen Test) |
5000.0 |
|
| 5.8 (Chemical Analysis) |
5000.0 |
|
|
| 10 |
F-20 EIL SPECIFICATION B269-000-02-42-PCS-0001 Rev. 2 (0) - F-20 EIL SPECIFICATION B269-000-02-42-PCS-0001 Rev. 2
SPECIFICATION FOR SURFACE PREPARATION AND PROTECTIVE COATING SYSTEM -
NEW CONSTRUCTION |
F-20 EIL SPECIFICATION B269-000-02-42-PCS-0001 Rev. 2
SPECIFICATION FOR SURFACE PREPARATION AND PROTECTIVE COATING SYSTEM -
NEW CONSTRUCTION |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Volume of Solids % (ASTMD 2697 Air drying method )) |
1500.0 |
|
| 2 (Dry Film Thickness per coat, microns) |
1200.0 |
|
| 3 (Theoretical coverage m2/litre/coat) |
1200.0 |
|
| 4 (weight per litre in Kg/litre) |
1500.0 |
|
| 5 (Touch Dry @ 30°C Hours) |
500.0 |
|
| 6 (Hard Dry Time @ 30°C ; Hours) |
500.0 |
|
| 7 (Full Cure @ 30°C in hours) |
1000.0 |
|
| 8 (Overcoating Intervals Hours) |
1500.0 |
|
| 9 (Pot Life) |
1500.0 |
|
| 10 (Adhesion ASTM D 4541 Mpa) |
3500.0 |
|
| 11 (Tensile Strength ( ASTM D638) N/mm2) |
5000.0 |
|
| 12 (Temperature Resistance (at 90 Deg C ASTM D 2485 Method A) |
2500.0 |
|
|
| 11 |
System- 7 EIL SPEC B224-000-79-41-PLS-01 REV6 (2021) - System -7 ( F20+F20. Total DFT 1100 microns) EIL SPEC B224-000-79-41-PLS-01 REV 6 HRRL JOB SPECIFICATION FOR SURFACE PREPARATION AND PROTECTIVE COATINGS |
System -7 ( F20+F20. Total DFT 1100 microns) EIL SPEC B224-000-79-41-PLS-01 REV 6 HRRL JOB SPECIFICATION FOR SURFACE PREPARATION AND PROTECTIVE COATINGS |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (100% Humidity Test for 1440 hrs
(ASTM D2247)) |
20000.0 |
|
| 2 (Chemical resistance Test ASTM D 543 10 % NaOH &40 % NaOH for 100 hrs.) |
2000.0 |
|
| 3 (Chemical resistance Test ASTM D 543,5 %f H2SO4 for 168 hrs.) |
2000.0 |
|
| 4 (Chemical resistance Test ASTM D 543,Acetone for 4 weeks,) |
2000.0 |
|
| 5 (Chemical resistance Test , ASTM D 543 Xylene for 4 weeks) |
2000.0 |
|
| 6 (Chemical resistance Test, ASTM D 543 Ethanol for 4 weeks) |
2000.0 |
|
| 7 (Chemical resistance Test ASTM D 543,Kerosene for 4 weeks) |
2000.0 |
|
| 8 (Chemical resistance Test, ASTM D 543 Sea Water 2000 hrs.) |
10000.0 |
|
| 9 (Immersion in DM/DI water @90deg.C (ASTM C868) for 30 days) |
4000.0 |
|
|
| 12 |
NTH_CUSTOM/2026/006 - Customize specification for Paint & High Polymer |
Customize specification for Paint & High Polymer |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Stain Cleanability test of pencil ) |
1200.0 |
|
| 1 (Stain Cleanability test of pencil ) |
1200.0 |
|
| 2 (Stain Cleanability test of Lipstick ) |
1200.0 |
|
| 3 (Stain Cleanability test of Crayon ) |
1200.0 |
|
| 4 (Resistance to Acid as per ASTN D543; in 3% Sulphuric Acid, Practice A Immersion test for 90 days test duration ) |
4000.0 |
|
| 5 (Resistance to Xylene as per ASTM D543; Practice - A Immersion Test for 90 Days test duration ) |
4000.0 |
|
| 6 (Resistance to Gasoliline as per ASTM D543; in Kerosene Practice - A Immersion Test for 90 Days duration period ) |
4000.0 |
|
| 7 (Resistance to Alkali as per ASTM D543; in 2% Sodium Carbonate Practice-A Immersion Test ) |
4000.0 |
|
| 8 (Resistance to White Spirit in ASTM D543; Practice - A Immersion Test ) |
4000.0 |
|
| 9 (Resistance to Water Condensation as per ISO 6270 - 1 ) |
12960.0 |
|
| 10 (NEUTRAL SALT SPRAY TEST (350 hrs)) |
17500.0 |
|
| 11 (NEUTRAL SALT SPRAY TEST (100 hrs)) |
5000.0 |
|
| 12 (NEUTRAL SALT SPRAY TEST (200 hrs)) |
10000.0 |
|
| 13 (NEUTRAL SALT SPRAY TEST (1000 hrs)) |
50000.0 |
|
|
| 13 |
Custom-4-NTH-LM - Omega Clamp/Profile Plate |
Omega Clamp/Profile Plate |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 8 (Salt Spray Test for 1440 Hours) |
72000.0 |
|
|
| 14 |
ND CUSTOM 13 (2026) - Load Test of Engineering Components |
Load Test of Engineering Components |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Load Test upto 10 Ton) |
2000.0 |
|
| 2 (Load Test 11 Ton to 25 Ton) |
2500.0 |
|
| 3 (Load Test 26 Ton to 40 Ton) |
3500.0 |
|
| 4 (Load Test 41 Ton to 55 Ton) |
5000.0 |
|
|
| 15 |
System-1 EIL SPEC B224-000-79-41-PLS-01 REV6 (2021) - System -1 (F9 + P6+ F6B + F2. Total DFT 345 microns) EIL SPEC B224-000-79-41-PLS-01 REV 6 HRRL JOB SPECIFICATION FOR SURFACE PREPARATION AND PROTECTIVE COATINGS |
System -1 (F9 + P6+ F6B + F2. Total DFT 345 microns) EIL SPEC B224-000-79-41-PLS-01 REV 6 HRRL JOB SPECIFICATION FOR SURFACE PREPARATION AND PROTECTIVE COATINGS |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 ("Cyclic Test
Salt Spray : 72 hrs.
Drying in air: 16 hrs.
UV-A340 nm weather meter: 80 hrs.
One cycle: 168 hrs.
(25 cycles at 168 hrs. each cycle)
(ASTM D5894)") |
200000.0 |
|
| 2 ("100% Humidity Test
(ASTM D2247)") |
25920.0 |
|
|
| 16 |
2046 (2025 (Part 2)) - Decorative Thermosetting Synthetic Resin Bonded Laminated Sheets |
Decorative Thermosetting Synthetic Resin Bonded Laminated Sheets |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Resistance to colour change in Xenon arc Weather-o-meter) |
5000.0 |
|
|
| 17 |
14255:1995 - IS 14255:1995 - Aerial bunched cables - For working voltages up to and including 1100 Volts - Specification: REC NTH Kolkata |
IS 14255:1995 - Aerial bunched cables - For working voltages up to and including 1100 Volts - Specification: REC NTH Kolkata |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| REC (As per NTH (HQ) Letter no. NTH/HQ/Test Fees/Revision/2025-26 dated 23.02.2026
Tests on Phase/Street Light Conductor: Tensile Test, CR Test, IR Test
Test on Messenger Conductor: Breaking Load, Elongation, CR
Test on Insulation and Sheath: Tensile and Elongation on break, Hot set, Thickness of Insulation and Sheath, High Voltage) |
8500.0 |
|
|
| 18 |
IS 164 :2023 - Ready mixed paint for Road marking |
Ready mixed paint for Road marking |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 3.1 (Volatile Organic compound) |
3000.0 |
|
| 5.2 (Application) |
1200.0 |
|
| 5.3 (Durability) |
3000.0 |
|
| 5.4 (Lead Restriction) |
1200.0 |
|
| 5.5 Sl No. i. a. (Surface Dry) |
1200.0 |
|
| 5.5 Sl No. i. b. (Hard Dry) |
1200.0 |
|
| 5.5 Sl No. ii (Consistency) |
1200.0 |
|
| 5.5 Sl No. iii. (Finish) |
1200.0 |
|
| 5.5 Sl No. iv (Color) |
1200.0 |
|
| 5.5 Sl No. v (Wet Opacity) |
1200.0 |
|
| 5.5 Sl No. vi (Recoating Property) |
1200.0 |
|
| 5.5 Sl No. vii (Resistance to bleeding) |
1200.0 |
|
| 5.5 Sl No. x (Mass in kg/10litre) |
1200.0 |
|
| 5.5 Sl No. xi (Keeping properties) |
5000.0 |
|
| 5.5 Sl No. xiii (No pick time) |
1200.0 |
|
| 5.5 Sl No. xiv (Non volatile matter) |
1200.0 |
|
| 5.5 Sl No. xv (Volume solid) |
2000.0 |
|
| 5.5 Sl No. xvi (Taber Abrasion Resistance) |
5000.0 |
|
| 5.5 Sl No. xvii (Scrub Resistance) |
2000.0 |
|
| 5.5 Sl No. xviii (Resistance to Accelerated Weathering) |
25000.0 |
|
| 5.5 Sl No. xix (Flexibility) |
1200.0 |
|
| 5.5 Sl No. xxi (Resistance to Wear) |
3000.0 |
|
|
| 19 |
Custom Paint for Wire Mesh Gabions - Custom Paint for Wire Mesh Gabions |
Custom Paint for Wire Mesh Gabions |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Abrasion Resistance Test) |
5000.0 |
|
| 2 (Resistance of polymer coating to sodium Chloride Solution Test as per clause 7.2 of IS 16014) |
1200.0 |
|
| 3 (Salt spray exposure 3000 hours) |
150000.0 |
|
|
| 20 |
F-12 EIL SPEC B224-000-79-41-PLS-01 REV6 (2021) - F-12 Technical Name: Heat resistant silicone aluminium paint suitable upto 540 Deg C dry temperature
HRRL JOB SPECIFICATION FOR SURFACE PREPARATION AND PROTECTIVE COATINGS |
F-12 Technical Name: Heat resistant silicone aluminium paint suitable upto 540 Deg C dry temperature
HRRL JOB SPECIFICATION FOR SURFACE PREPARATION AND PROTECTIVE COATINGS |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Volume soilds % minimum) |
1200.0 |
|
| 2 (DFT per coat microns) |
1200.0 |
|
| 3 (Theoretical covering capacity in m sq/coat/litre) |
1200.0 |
|
| 4 (Weight per liter in kg/litre) |
1200.0 |
|
| 5 (Touch dry at 30 Deg c max (hours)) |
1200.0 |
|
| 6 (Hard dry at 30 deg C max(hours)) |
1200.0 |
|
| 7 (Over coating interval , hours) |
1200.0 |
|
| 8 (Temperature resistance 540 ⁰ C Dry Service (ASTM D 2485 method B)) |
4200.0 |
|
| 9 (Temperature resistance540 ⁰ C (ASTM D 2485 method B)) |
1200.0 |
|
| 10 (Non Volatile Matter (% by mass)) |
1200.0 |
|
| 11 (Volatile Matter (% by mass)) |
1200.0 |
|
| 12 (Specific Gravity (ASTM D1475)) |
1200.0 |
|
| 13 (Ash Content (% by mass)) |
1200.0 |
|
|
| 21 |
Custom Thermoplastic Road Marking Material 2026 - Custom Thermoplastic Road Marking Material 2026 |
Custom Thermoplastic Road Marking Material 2026 |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Drying Time) |
1200.0 |
|
| 2 (Glass Bead Content) |
1200.0 |
|
| 3 (Binder Content) |
1200.0 |
|
| 4 (Softening Point) |
1200.0 |
|
|
| 22 |
MMDTS 18034 Rev.05 - Technical specification for PU based Wet-on-Wet applicable Exterior Painting System of LHB type coaches |
Technical specification for PU based Wet-on-Wet applicable Exterior Painting System of LHB type coaches |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 3.X (Anti-graffiti Test) |
5000.0 |
|
| 3.VIII (Cyclic Corrosion (ISO-11997-1 Cycle A for 1000 hours)) |
50000.0 |
|
| 3.IX (Distinctness of Image (DOI)) |
10000.0 |
|
|
| 23 |
IS 14255:1995 - Aerial bunched cables - For working voltages up to and including 1100 Volts - Specification |
Aerial bunched cables - For working voltages up to and including 1100 Volts - Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 10.1(a)(i), 10.2(a) (Tensile test (for phase/street light conductors)) |
1000.0 |
|
| 10.1(a)(ii), 10.2(b) (Wrapping Test) |
500.0 |
|
| 10.1(a)(iii), 10.2(e), 10.3(a) (Conductor Resistance Test) |
2000.0 |
|
| 10.1(b)(i),10.2(c) (Breaking load test on messanger conductor) |
1000.0 |
|
| 10.1(b)(ii),10.2(d) (Elongation test for messanger conductor) |
1500.0 |
|
| 10.1(b)(iii),10.2(e),10.3(a) (Conductor Resistance test on messanger) |
2000.0 |
|
| 10.1(c)(i), 10.2(g) (Tensile Strength and elongation at break for XLPE Insulation) |
1500.0 |
|
| 10.1(c)(ii) (Ageing in Air Oven for XLPE Insulation) |
2000.0 |
|
| 10.1(c)(iii), 10.2(h) (Hot Set Test for XLPE Insulation) |
2000.0 |
|
| 10.1(c)(iv) (Shrinkage Test for XLPE Insulation) |
1000.0 |
|
| 10.1(c)(v) (Water Absorption (Gravimetric) for XLPE Insulation) |
1000.0 |
|
| 10.1(d)(i),10.2(g) (Tensile Strength and elongation at break for PE Insulation) |
1500.0 |
|
| 10.1(d)(ii) (Melt Flow Index for PE Insulation) |
2000.0 |
|
| 10.1(d)(iv) (Vicat Softening point for PE Insulation) |
2000.0 |
|
| 10.1(e),10.2(f) (Test for thickness of Insulation) |
1500.0 |
|
| 10.1(f), 10.2(j) (Insulation Resistance Test (Volume Resistivity)) |
2000.0 |
|
| 10.1(g),10.2(k),10.3(b) (High Voltage Test) |
1500.0 |
|
|
| 24 |
IS 15965: 2012 - Pre-painted Aluminium Zinc Alloy Metallic Coated Steel Strip and Sheet (Plain) |
Pre-painted Aluminium Zinc Alloy Metallic Coated Steel Strip and Sheet (Plain) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
| 25 |
ND CUSTOM 12 (2025) - Custom Specification for Steel Plate , Quard 450 |
Custom Specification for Steel Plate , Quard 450 |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Ultrasonic Testing) |
3000.0 |
|
| 2 (Material Hardness) |
2000.0 |
|
|
| 26 |
RDSO SPECIFICATION No. M&C/ PCN/ 100/ 2018 (2018) - FULL GLOSS POLYURETHANE ENAMEL (TWO PACK) |
FULL GLOSS POLYURETHANE ENAMEL (TWO PACK) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Identification of polyisocyanates) |
1200.0 |
|
| 2 (Drying time
a) Surface dry
b) Hard dry
c) Hard dry at 70 Deg. C) |
3600.0 |
|
| 3 (Consistency) |
1200.0 |
|
| 4 (Finish) |
1200.0 |
|
| 5 (Colour) |
1200.0 |
|
| 6 (Dry film thickness) |
1200.0 |
|
| 7 (Volume solids) |
1200.0 |
|
| 8 (Scratch hardness (1.5 Kg Load)) |
1200.0 |
|
| 9 (Flexibility & Adhesion (6.25 mm mandrel)) |
1200.0 |
|
| 10 (Flash point
(a) Component ‘A’
(b) Component ‘B’) |
2400.0 |
|
| 11 (Fineness of Grind) |
1200.0 |
|
| 12 (Pot life (After induction time) at
a) 27±2°C
b)40±2ºC) |
1500.0 |
|
| 13 (Gloss at 60° angle of incidence) |
1200.0 |
|
| 14 (Mass in Kg/10 litres) |
1200.0 |
|
| 15 (Keeping properties) |
5000.0 |
|
| 16 (Theoretical spreading rate) |
2000.0 |
|
| 17 (% poly isocyanate by mass, in hardener) |
3000.0 |
|
| 18 (Viscosity (Efflux time by Ford cup No.4) of paint i.e. mix. Of two components at 27± 2 °C in Supply condition) |
1200.0 |
|
| 19 (Accelerated Tests
(a) Resistance to 30% Sulphuric acid (weight by volume)
(b) Resistance to 20% caustic potash (weight by volume)
(c) Resistance to oil
(d) Resistance to solvents
(e) Resistance to water) |
7200.0 |
|
| Durability test (Accelerated Test for Durability, 750 hrs (ASTM G 53, 4 hrs UV and 4 hrs Condensation)) |
45000.0 |
|
| 22 (Abrasion resistance-1000 Cycle) |
5000.0 |
|
| 21 (Humidity Test (500 Hours)) |
9000.0 |
|
|
| 27 |
RDSO SPECIFICATION No. M&C/ PCN/ 100/ 2018 (2018) - SPECIFICATION FOR EPOXY CUM POLYURETHANE PAINTING SYSTEM
(TWO PACK) FOR THE EXTERIOR PAINTING OF RAILWAY COACHES,
DIESEL AND ELECTRIC LOCOMOTIVES AND OTHER INDUSTRIAL APPLICATIONS |
SPECIFICATION FOR EPOXY CUM POLYURETHANE PAINTING SYSTEM
(TWO PACK) FOR THE EXTERIOR PAINTING OF RAILWAY COACHES,
DIESEL AND ELECTRIC LOCOMOTIVES AND OTHER INDUSTRIAL APPLICATIONS |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
| 28 |
IS 17044 :2018 - Intumescent Fire Retardant Paint (Water Based) — Specification |
Intumescent Fire Retardant Paint (Water Based) — Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 3.3, i (Colour) |
1200.0 |
|
| 3.3, ii (Preliminary Examination) |
1200.0 |
|
| 3.3, iii (Application properties & Finish) |
1200.0 |
|
| 3.3, iv (Consistency) |
1200.0 |
|
| 3.3, v, a (Surface Dry) |
1200.0 |
|
| 3.3, v, b (Hard dry) |
1200.0 |
|
| 3.3, vi (Dry Film Thickness) |
1200.0 |
|
| 3.3, vii (Scratch Hardness) |
1200.0 |
|
| 3.3, viii (Flexibility & Adhesion (Bend Test)) |
1200.0 |
|
| 3.3, ix (Mass in kg/10 litre) |
1200.0 |
|
| 3.3, x (Pigment , % by mass) |
1200.0 |
|
| 3.3, xi (Volatile Matter, % by mass) |
1200.0 |
|
| 3.3, xii (Fire Test) |
8000.0 |
|
|
| 29 |
IS 104 (2017) - Ready Mixed Paint, Brushing, Zinc Chrome, Priming |
Ready Mixed Paint, Brushing, Zinc Chrome, Priming |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| i) Table 1 Cl 4.3&7.1 (Consistency) |
100.0 |
|
| ii) Table 1 Cl 4.3&7.1 (Finish) |
100.0 |
|
| iii) Table 1 Cl 4.3&7.1 (Drying time-Hard dry in hours) |
100.0 |
|
| iv) Table 1 Cl 4.3&7.1 (Mass, kg/10 liter) |
100.0 |
|
| v) Table 1 Cl 4.3&7.1 (colour) |
100.0 |
|
| vi) Table 1 Cl 4.3&7.1 (Wet opacity, m2/10 liter) |
100.0 |
|
| vii.a) Table 1 Cl 4.3&7.1 (Flexibility and adhesion
a. Scratch hardness (Load 1 000 g)) |
100.0 |
|
| vii.b) Table 1 Cl 4.3&7.1 (Flexibility and adhesion
b) Bend test, with 6.25 mm dia mandrel and type 1 apparatus) |
100.0 |
|
| viii) Table 1 Cl 4.3&7.1 (Flash point) |
200.0 |
|
| ix.a) Table 1 Cl 4.3&7.1 (Resistance to humidity Under conditions of condensation
a)Resistance to humidity) |
2000.0 |
|
| ix.b) Table 1 Cl 4.3&7.1 (Resistance to humidity Under conditions of condensation
b)Resistance to salt spray) |
2000.0 |
|
| x) Table 1 Cl 4.3&7.1 (Keeping properties) |
5000.0 |
|
| Cl 4.1 (Pigment content, percent by mass
(IS:101 part 8/sec 2:1990)) |
1000.0 |
|
| Cl 4.1.1 ANNEX B (Chromic anhydride(CrO3) content, percent by mass) |
2000.0 |
|
| Cl 4.1.1 ANNEX B (Zinc oxide(ZnO) content, percent by mass) |
2000.0 |
|
| Cl 4 (Zinc chrome content, percent by mass
( including Chromic anhydride & Zinc Oxide)) |
100.0 |
|
| Cl 4 (Lead Restriction) |
2000.0 |
|
|
| 30 |
IIWIC-PCS (2025) - IIW-India Certification Personnel Certification Scheme for MMAW-Foundation |
IIW-India Certification Personnel Certification Scheme for MMAW-Foundation |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 3.0 (Visual Examination) |
1000.0 |
|
| 3.0 (Macro Examination (01 position)) |
1000.0 |
|
| 3.0 (Macro Examination (02 positions)) |
2000.0 |
|
| 3.0 (Fracture Test) |
3000.0 |
|
| 3.0 (Face Bend) |
1000.0 |
|
| 3.0 (Root Bend) |
1000.0 |
|
|