| 1921 |
National Test House (SR), Chennai
| IRC:SP:20 (2002) - RURAL ROADS MANUAL |
RURAL ROADS MANUAL |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Appendix 10.8 (Bitumen/Binder Content) |
3000.0 |
|
| Custom (Bitumen/Binder content of DBM core [On the lines of IRC:SP:20 (2002)]) |
4000.0 |
|
| Custom (Bitumen/Binder content of BC core [On the lines of IRC:SP:20 (2002)]) |
4000.0 |
|
|
| 1922 |
National Test House (ER), Kolkata
| CUSTOM-25-ER-MCALI - Calibration of Floating Carriage Micrometer |
Calibration of Floating Carriage Micrometer |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Length) |
2400.0 |
|
|
| 1923 |
National Test House (ER), Kolkata
| IS 16172 (2023) - Reinforcement couplers for mechanical splices of bars in concrete - Specification |
Reinforcement couplers for mechanical splices of bars in concrete - Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 7 (Visual Observation (Workmanship and Finish)) |
1000.0 |
|
| 8 (Chemical composition, % by mass) |
3000.0 |
|
| 9.2 (Tensile Strength as per IS 1608(Part 1):2022) |
1500.0 |
|
| 9.2 (Percentage Elongation as per IS 1608(Part 1):2022) |
1500.0 |
|
| 9.2 (Visual Observation for Nature & Location of failure of spliced specimen (With Coupling).) |
1000.0 |
|
| 0 (Test results as per customer test request.) |
15000.0 |
|
| 9.2.1 (The tensile strength of the spliced bar ( With Coupling)) |
2500.0 |
|
| 9.2.2 (The minimum percentage elongation at maximum force (also termed as uniform elongation) for spliced bar ( with coupler) when measured in accordance with the method given in Annex B in the reinforcing bar outside the length of the mechanical splice before failure.) |
1000.0 |
|
| 9.2.2 (The percentage elongation at maximum force for unspliced specimen) |
1000.0 |
|
|
| 1924 |
National Test House (NR), Ghaziabad
| AWS specification - Specification for Fracture Test |
Specification for Fracture Test |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| - (Fracture Test) |
9000.0 |
|
|
| 1925 |
National Test House (ER), Kolkata
| CUSTOM-24-ER-MCALI (2023) - Calibration of Profile Projector |
Calibration of Profile Projector |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Magnification) |
2000.0 |
|
| 2 (Angle) |
2000.0 |
|
| 3 (Length) |
2000.0 |
|
| 4 (Length) |
2000.0 |
|
|
| 1926 |
National Test House (SR), Chennai
| IS 516(Part 1/Section 1):2021 - Hardened Concrete-Methods of Tests-( Part 1-Testing of strength of Hardened Concrete-Determination of Compressive, Flexural strength and Split tensile strength) |
Hardened Concrete-Methods of Tests-( Part 1-Testing of strength of Hardened Concrete-Determination of Compressive, Flexural strength and Split tensile strength) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 4 (Flexural strength(IS 516(Part 1/Section 1):2021)) |
2500.0 |
|
| 3 (Compressive strength of concrete cubes(MPa)) |
1200.0 |
|
|
| 1927 |
National Test House (SR), Chennai
| MORTH 5th Revision table 900-4/IRC:111-2009 - Dense bituminous macadam/bituminous concrete-Specification for dense graded bitumen mixes |
Dense bituminous macadam/bituminous concrete-Specification for dense graded bitumen mixes |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Morth 5th revision table 900-4,5.i (Quality of binder-PAVING BITUMEN (IS 73:2013)) |
5000.0 |
|
| - (Deleterious materials (IS 2386)) |
2000.0 |
|
| - (Aggregate Impact value(IS 2386(4))) |
1500.0 |
|
| - (Aggregate Abrasion Value(IS 2386(4))) |
1500.0 |
|
| - (Flakiness & Elongation Index-Combined(IS 2386(1))) |
3000.0 |
|
| - (Stripping Value of aggregates(IS 6241)) |
1500.0 |
|
| - (Water absorption of aggregates(IS 2386(3))) |
1000.0 |
|
| - (Grading of Aggregates/Grain size analysis(IS 2386(1))) |
2000.0 |
|
|
| 1928 |
National Test House (NER), Guwahati
| IS 2095 : Part 1 (2011) - Gypsum Plaster Boards - Part 1 Plain Gypsum Plaster Boards |
Gypsum Plaster Boards - Part 1 Plain Gypsum Plaster Boards |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 7.3, Table3, 8.1 (Transverse Strength-IS: 2542 (Part 2/Sec 4)) |
4000.0 |
|
| 7.1, Table1 /Table2, 8.1 (Dimensions-IS: 2542 (Part 2/Sec 1)) |
500.0 |
|
|
| 1929 |
National Test House (ER), Kolkata
| IS 9857:1990 (1990) - Welding Cable Specification |
Welding Cable Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 10.1.a.2 (Test on Conductor- Conductor Resistance Test) |
2500.0 |
|
| 10.1.b (Test for thickness of Covering) |
1500.0 |
|
| 10.1.d (High Voltage Test (Water Immersion Test)) |
3500.0 |
|
|
| 1930 |
National Test House (WR), Mumbai
| IS 16098(Part 2) - STRUCTURED-WALL PLASTICS PIPING SYSTEMS FOR NON-PRESSURE DRAINAGE AND SEWERAGE |
STRUCTURED-WALL PLASTICS PIPING SYSTEMS FOR NON-PRESSURE DRAINAGE AND SEWERAGE |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| - (Outer Diameter(mm.)) |
1000.0 |
|
| - (Inner Diameter(mm.)) |
1000.0 |
|
| - (Wall Thickness(mm.)) |
1000.0 |
|
| - (Impact Test) |
2000.0 |
|
| - (Resistance to heating oven test) |
2000.0 |
|
| - (Ring Flexibility) |
2000.0 |
|
|
| 1931 |
National Test House (NR), Ghaziabad
| Fastener as per ISO/EN/BS EN - Mechanical properties of Fastener as per ISO 898 (Part- 1, 2), EN 14399 (P-3,5,9), ISO 10683 |
Mechanical properties of Fastener as per ISO 898 (Part- 1, 2), EN 14399 (P-3,5,9), ISO 10683 |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 7.1 (Proof Load, kN) |
3000.0 |
|
| 7.2 (Hardness) |
2000.0 |
|
| 7.3 (Surface Integrity) |
2000.0 |
|
| 7.4 (Depth of Decarburisation) |
2000.0 |
|
| 7.5 (Coating Thickness, micron) |
2000.0 |
|
| 7.6 (Adhesion test) |
1000.0 |
|
| 6 (Chemical composition, % by mass) |
2500.0 |
|
| 5.1 (Wedge Load Test) |
3000.0 |
|
| 5.2 (Tensile test- TS, YS, %E and RoA) |
4000.0 |
|
| 5.4 (Charpy Impact Test, At -20 deg C) |
3000.0 |
|
| 5.5 (Compression load Test) |
3000.0 |
|
| 5.5 (Dimensions, mm) |
2000.0 |
|
|
| 1932 |
National Test House (ER), Kolkata
| RDSO SPECIFICATION No. M&C/ PCN/ 100/ 2018 (2018) - SPECIFICATION FOR EPOXY CUM POLYURETHANE PAINTING SYSTEM
(TWO PACK) FOR THE EXTERIOR PAINTING OF RAILWAY COACHES,
DIESEL AND ELECTRIC LOCOMOTIVES AND OTHER INDUSTRIAL APPLICATIONS |
SPECIFICATION FOR EPOXY CUM POLYURETHANE PAINTING SYSTEM
(TWO PACK) FOR THE EXTERIOR PAINTING OF RAILWAY COACHES,
DIESEL AND ELECTRIC LOCOMOTIVES AND OTHER INDUSTRIAL APPLICATIONS |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| APPENDIX –VII METHOD OF IDENTIFYING AROMATIC AND ALIPHATIC ISOCYANATE (Identification of poly isocyanate ( aliphatic or aromatic in nature) procedure in Appendix- VII.
Specification No M&C /PCN/100/2018) |
3000.0 |
|
|
| 1933 |
National Test House (ER), Kolkata
| IS 4984 (2016) - Polyethylene pipes for water supply - Specification (Fifth Revision) |
Polyethylene pipes for water supply - Specification (Fifth Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 8.6 (Overall Migration (Chemical Lab)) |
2000.0 |
|
| 8.4 (Melt Flow Rate at 190 degree celcius and 5kgf) |
2000.0 |
|
| 8.2 (Longitudinal Reversion Test) |
2000.0 |
|
| 7.4 (Wall Thickness) |
500.0 |
|
| 7.2 (Length) |
1000.0 |
|
| 7.1 (Visual Appearance) |
500.0 |
|
| 6.2 (Colour) |
- |
|
| 8.3 (Carbon Black Dispersion) |
1000.0 |
|
| 7.4.1 (Outside Diameter) |
500.0 |
|
| 7.4.1.2 (Ovality) |
100.0 |
|
| 6.2.1 (Colour Of strip) |
- |
|
| 6.2.1 (Width Of Strip) |
100.0 |
|
| Firm's request (Hardness(Shore D)) |
1000.0 |
|
| firm's request (Density) |
2000.0 |
|
|
| 1934 |
National Test House (ER), Kolkata
| Custom-33-ER-LM - Load Test |
Load Test |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Load Test) |
15000.0 |
|
|
| 1935 |
National Test House (WR), Mumbai
| IS 1367 : Part 14 : Sec 3 : 2018 (2018) - Technical Supply Conditions for Threaded Steel Fasteners Part 14 Mechanical Properties of Corrosion-resistant Stainless-steel Fasteners Section 3 Set Screws and Similar Fasteners not Under Tensile Stress (Fourth Revision) |
Technical Supply Conditions for Threaded Steel Fasteners Part 14 Mechanical Properties of Corrosion-resistant Stainless-steel Fasteners Section 3 Set Screws and Similar Fasteners not Under Tensile Stress (Fourth Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 3 (Visual Observations of Designation, Marking and Finish) |
1000.0 |
|
| 5.2 (Hardness Test in Vickers/ Brinell/Rockwell as per the relevant IS spec.) |
2000.0 |
|
| 4 (Chemical compositions (in % )of stainless steels suitable for fasteners in accordance with this part of ISO 3506 are given in table 2.) |
5000.0 |
|
|
| 1936 |
National Test House (WR), Mumbai
| IS 1367 : Part 6 (2018) - Technical Supply Conditions for Threaded Steel Fasteners Part 6 Mechanical Properties of Fasteners Made of Carbon Steel and Alloy Steel — Nuts with Specified Property Classes — Coarse Thread and Fine Pitch Thread |
Technical Supply Conditions for Threaded Steel Fasteners Part 6 Mechanical Properties of Fasteners Made of Carbon Steel and Alloy Steel — Nuts with Specified Property Classes — Coarse Thread and Fine Pitch Thread |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6 (Chemical composition, % by mass) |
2500.0 |
|
|
| 1937 |
National Test House (WR), Mumbai
| IS 1367 : Part 3 (2017) - Technical Supply Conditions for Threaded Steel Fasteners Part 3 Mechanical Properties of Fasteners Made of Carbon Steel and Bolts, Screws and Studs |
Technical Supply Conditions for Threaded Steel Fasteners Part 3 Mechanical Properties of Fasteners Made of Carbon Steel and Bolts, Screws and Studs |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6 (Chemical Composition, % by mass) |
2500.0 |
|
| 7 (Surface Integrity (Table 3 in accordance with ISO 6157 - 1 )) |
1200.0 |
|
| 7 (Mechanical and physical properties (tensile Strength)) |
3.0 |
|
| 7 (Mechanical and physical properties (ultimate tensile load)) |
3000.0 |
|
| 7 (Mechanical and physical properties (Proof load test)) |
2000.0 |
|
| 7 (Mechanical and physical properties (Hardness,Rockwell C scale)) |
2000.0 |
|
| 7 (Mechanical and physical properties (Hardness,Vickers)) |
2000.0 |
|
|
| 1938 |
National Test House (WR), Mumbai
| IS 1367 : Part 6 (2018) - Technical supply conditions for threaded steel fasteners: Part 6 mechanical properties of fasteners made of carbon steel and alloy steel - Nuts with specified property classes - Coarse thread and fine pitch thread (Fourth Revision) |
Technical supply conditions for threaded steel fasteners: Part 6 mechanical properties of fasteners made of carbon steel and alloy steel - Nuts with specified property classes - Coarse thread and fine pitch thread (Fourth Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 7 (Surface Integrity) |
1200.0 |
|
| 7 (Hardness Test) |
2000.0 |
|
| 7 (Proof Load) |
3000.0 |
|
| 7, Table 6 (Rockwell hardness, HRC) |
2000.0 |
|
| 6 (Chemical composition, % by mass) |
2500.0 |
|
|
| 1939 |
National Test House (WR), Mumbai
| IS 1367 : Part 3 (2017) - Technical supply conditions for threaded steel fasteners: Part 3 mechanical properties of fasteners made of carbon steel and bolts, screws and studs (Fifth Revision) |
Technical supply conditions for threaded steel fasteners: Part 3 mechanical properties of fasteners made of carbon steel and bolts, screws and studs (Fifth Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5 (Surface Integrity) |
1200.0 |
|
| 7 (Hardness Test) |
2000.0 |
|
| 7 (Wedge loading test) |
3000.0 |
|
| 7 (Proof Load, N.) |
3000.0 |
|
| 7 (Tensile load, N.) |
3000.0 |
|
| 2 (Dimensions) |
1500.0 |
|
| 6 (Carbon, % by mass) |
500.0 |
|
| 6 (Phosphorus, % by mass) |
500.0 |
|
| 6 (Sulphur, % by mass) |
500.0 |
|
| 6 (Boron, % by mass) |
625.0 |
|
|
| 1940 |
National Test House (WR), Mumbai
| IS 1367 : Part 13 (2020) - Technical Supply Conditions for Threaded Steel Fasteners Part 13 Hot Dip Galvanized Coatings on Threaded Fasteners ( Third Revision ) |
Technical Supply Conditions for Threaded Steel Fasteners Part 13 Hot Dip Galvanized Coatings on Threaded Fasteners ( Third Revision ) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 8.3 (Coating Thickness) |
2000.0 |
|
|
| 1941 |
National Test House (SR), Chennai
| IS 1708/IS 3629/IS 4970/IS 1331 - Methods of small clear specimens of Timber/Structural timber in building/keys for identification of timber/Specification for cut sizes of timber [All Timber] |
Methods of small clear specimens of Timber/Structural timber in building/keys for identification of timber/Specification for cut sizes of timber |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Compressive strength parallel to grain(IS 1708(8)1986)) |
1500.0 |
|
| 2 (Compressive strength perpendicular to grain(IS 1708( 9)1986)) |
1500.0 |
|
| 3 (Static bending strength-M of R ( IS 1708(5)1986)) |
1500.0 |
|
| 4 (Screw holding power(IS 1708(15)1986)) |
1500.0 |
|
| 5 (Nail holding power(IS 1708(15)1986)) |
1500.0 |
|
| 6 (Specific gravity(IS 1708(2)1986)) |
1000.0 |
|
| 7 (Moisture content(IS 1708(1)1986)) |
1000.0 |
|
| 8 (Identification of Timber(IS 4970-1973)) |
5000.0 |
|
| 9 (Timber grade(IS 1331-1971)) |
3000.0 |
|
|
| 1942 |
National Test House (NER), Guwahati
| NTH/NER/Custom/2023/08 (2023) - Custom Specification for GI Ceiling Section, Angle, Intermadiate Channel, Perimeter Channel, Powder Coated Main T-runner, Powder Coated Cross T-runner, Powder Coated Wall Angle |
Custom Specification for GI Ceiling Section, Angle, Intermadiate Channel, Perimeter Channel, Powder Coated Main T-runner, Powder Coated Cross T-runner, Powder Coated Wall Angle |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Dimension) |
2000.0 |
|
| 2 (Thickness of the section) |
1000.0 |
|
| 3. (Mass of zinc coating(Both Sides), gm/Sq. m) |
2000.0 |
|
| 4 (Thickness of powder coating in micron) |
2000.0 |
|
| 5 (Length) |
667.0 |
|
| 6 (Breadth) |
667.0 |
|
| 7 (Width) |
666.0 |
|
|
| 1943 |
National Test House (WR), Mumbai
| IS 11688:2022 (2022) - Standard Newsprint-Specification |
Standard Newsprint-Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| As per clause no.6.2 of IS 11688:2022 (Grammage, gm/sq. m.(as per IS 1060(Part 5/Sec 5))) |
1000.0 |
|
| As per table 1 sl.no. (i)of IS 11688:2022 (Brightness ISO, Percent(as per IS 1060(Part 4/Sec 13))) |
2000.0 |
|
| As per table 1 sl.no.(iii)of IS 11688:2022 (Smoothness(Bendtsen), ml./min.(as per IS 1060(Part 5/Sec 20))) |
2000.0 |
|
|
| 1944 |
National Test House (NWR), Jaipur
| Custom for Ace Flexi pack - Custom for Ace Flexi pack specification for Degradable bags |
Custom for Ace Flexi pack specification for Degradable bags |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (IS: 2508 Thickness (micron)) |
1000.0 |
|
| 2 (IS:9738:2003 (Water Leak Test )) |
1000.0 |
|
| 3 (IS:12395 (Resistance to Drop Impact test)) |
1000.0 |
|
|
| 1945 |
National Test House (SR), Chennai
| IS 8183:1993 - Bonded Mineral Wool |
Bonded Mineral Wool |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 4.1. (Description) |
1000.0 |
|
| 4.2 (Bulk density (IS 3144 )) |
1000.0 |
|
| 4.3 (Recovery after Compression(IS 3144)) |
1500.0 |
|
| 4.5 (Moisture content (IS 3144)) |
1000.0 |
|
| 4.5 (Moisture Absorption (IS 3144)) |
1000.0 |
|
| 4.8 (Sulphur content(IS 3144)) |
1000.0 |
|
| 4.9 (Dimension) |
1000.0 |
|
| 4.10.2 (Odour emission test (IS 3144)) |
1000.0 |
|
| 4.10.6 (Alkalinity ( IS 3144)) |
1000.0 |
|
|
| 1946 |
National Test House (NWR), Jaipur
| IS 9806 (2001) - Methods of test for and permissible limits of toxic materials released from ceramicware, vitreous enamelware, glassware and glass - Ceramicware in contact with food (First Revision) |
Methods of test for and permissible limits of toxic materials released from ceramicware, vitreous enamelware, glassware and glass - Ceramicware in contact with food (First Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 10 (Lead (Pb) mg/l) |
1000.0 |
|
| 10 (Cadmium (as Cd) mg/l) |
1000.0 |
|
|
| 1947 |
National Test House (ER), Kolkata
| Custom - Raw Water (NMDC) (Vide Annexure) |
Raw Water (NMDC) (Vide Annexure) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Chemical Parameters Vide Annexure) |
12000.0 |
|
|
| 1948 |
National Test House (WR), Mumbai
| ASTM D 2370 - Standard test methods for Tensile properties |
Standard test methods for Tensile properties |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| - (Tensile Strength and Elongation at Break) |
2000.0 |
|
|
| 1949 |
National Test House (ER), Kolkata
| CUSTOM/TEXTILE/2024 - CUSTOM/TEXTILE/2024 |
CUSTOM/TEXTILE/2024 |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1.0 (Average GSM) |
1000.0 |
|
| 2.0 (Thread per inch (Warp)) |
500.0 |
|
| 3.0 (Threads per inch (Weft)) |
500.0 |
|
| 4.0 (Yarn Count (warp)) |
1000.0 |
|
| 5.0 (Yarn Count (Weft)) |
1000.0 |
|
| 6.0 (Blend Composition %) |
2000.0 |
|
| 7.0 (Colour Fastness to Washing) |
2000.0 |
|
| 8.0 (Type of Weave) |
500.0 |
|
| 9.0 (pH) |
1000.0 |
|
| 10 (Tensile Strength) |
2000.0 |
|
|
| 1950 |
National Test House (ER), Kolkata
| Valve protective coating on Ductile Cast Iron (as per BS 2789 Gr 420/12 or 500/7) (2023) - Valve protective coating on Ductile Cast Iron (as per BS 2789 Gr 420/12 or 500/7) |
Valve protective coating on Ductile Cast Iron (as per BS 2789 Gr 420/12 or 500/7) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Coating dry film thickness (DFT) for flat surface
Cl 5.3.1 of DIN 30677- Part 1) |
1000.0 |
|
| 2 (Coating dry film thickness (DFT) for convex surface
Cl 5.3.21 of DIN 30677 Part 1) |
1000.0 |
|
| 3 (Cyclic Salt Spray Test (for 24 hours)
ASTM B 117) |
6000.0 |
|
| 4 (Cycle Artificial Weathering Test 100% Humidity (for 24 hours
ASTM D 2247
10 Cycles) |
6500.0 |
|
| 5 (Cathodic Disbondment Test (for evaluation of any pitting development)
For 30 days at 23 ± 2° C
ASTM G-95) |
7500.0 |
|
| 6 (Cathodic Disbondment Test (for evaluation of any pitting development)
For 2 days at 65 ± 2° C
ASTM G-95) |
1500.0 |
|
| 7 (Bond Strength
Cl 4.2.2 of DIN 30677 Part 1 – Feb 1991) |
2500.0 |
|
|