| 1981 |
National Test House (WR), Mumbai
| IS 16714:2018 - Ground Granulated Blast Furnace Slag for Use in Cement, Mortar and Concrete |
Ground Granulated Blast Furnace Slag for Use in Cement, Mortar and Concrete |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5.1 Table 1 (Chemical Requirements of GGBS) |
5000.0 |
|
| 6,Table 2 (Physical requirements) |
5000.0 |
|
|
| 1982 |
National Test House (SR), Chennai
| IS 12406 (2021) - Medium density fibre boards for general purpose - Specification (First Revision) |
Medium density fibre boards for general purpose - Specification (First Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 9, Table 3 and 4, Sl No (x) (Screw Withdrawal Strength-IS 2380 (Part 14): 1977) |
1500.0 |
|
| 9, Table 3 and 4, Sl No (vii) (Internal Bond strength after cyclic/accelerated water resistance test-IS 12406:2021 & IS 2380 (Part 5): 1977) |
2000.0 |
|
| 9, Table 3 and 4, Sl No (vi) (Internal Bond Strength-IS 2380 (Part 5): 1977) |
2000.0 |
|
| 9, Table 3 and 4, Sl No (viii) (Modulus of Rupture -IS 2380 (Part 4): 1977) |
2500.0 |
|
| 9, Table 3 and 4, Sl No (ix) (Modulus of Elasticity-IS 2380 (Part 4): 1977) |
2000.0 |
|
| 9, Table 3 and 4, Sl. No. (v) (Linear Expansion (thickness swelling of water) due to general absorption after 24 hr soaking -IS 2380 (Part17): 1977) |
1000.0 |
|
| 9, Table 3 and 4, Table 3 & 4, Sl. No. (iii) & (iv) (Moisture Content-IS 2380 (Part 3): 1977) |
1000.0 |
|
| 9, Table 3 & 4, Sl. No. (i) & (ii) (Density-IS 2380 (Part 3): 1977) |
500.0 |
|
| 8, Table 2 (Dimension & Tolerances-IS 12406:2021, Annex A) |
500.0 |
|
| 7 (Finish-IS 12406:2021) |
1000.0 |
|
| custom (Compressive strength-Parallel) |
1500.0 |
|
| custom (Compressive strength (Perpendicular)) |
1500.0 |
|
| custom (Lead content) |
1200.0 |
|
| custom (Shore D) |
1000.0 |
|
| custom (Tensile strength) |
4000.0 |
|
|
| 1983 |
National Test House (WR), Mumbai
| NTH(WR)/MECH/CUSTOM/007 Dimesnion as per Drawing (2024) - Dimesnion Measurment as per Drawing |
Dimesnion Measurment as per Drawing |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1.0 (Dimesnion Measurment in mm as per drawing or customer specification or relevant IS or other international Standard or as per NTH(WR) SOP.) |
2000.0 |
|
|
| 1984 |
National Test House (NWR), Jaipur
| 9738 (2003) - Polyethylene bag for general purpose |
Polyethylene bag for general purpose |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5.0 (Cl.5.0 (Structure and Shape)) |
1000.0 |
|
| Length (Length (IS:9738)) |
1000.0 |
|
| 7.0 (Width(IS:9738)) |
1000.0 |
|
| 7.3 (Average thickness) |
1000.0 |
|
| 7.0 (Nominal Thickness (IS:9738)) |
1000.0 |
|
| 8.1 (Appearance (IS:9738)) |
1000.0 |
|
| 5 (Printing Ink Adhesion test) |
1000.0 |
|
| 8.2 (Water Leak Test (IS:9738)) |
1000.0 |
|
| 8.4 (Drop Test (IS:9738)) |
2000.0 |
|
| 10 (IS:9738 (PACKING AND MARKING)) |
500.0 |
|
| 9 (Tests) |
7000.0 |
|
| 10 (Tests) |
4000.0 |
|
|
| 1985 |
National Test House (NR), Ghaziabad
| IEC 62561-2 (2018) - Lightning protection system components (LPSC) – Part 2: Requirements for conductors and earth electrodes |
Lightning protection system components (LPSC) – Part 2: Requirements for conductors and earth electrodes |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5.2.5 (Electrical Resistivity test) |
2000.0 |
|
| 5.2.4 (Environmental test (Salt spray test 48 hrs)) |
2000.0 |
|
| 5.2.3 (Adhesion test) |
1000.0 |
|
| 5.2.2 (Test for thickness of coating) |
2000.0 |
|
| 5.2.6 (Tensile test) |
3000.0 |
|
| 0 (Bend test) |
1000.0 |
|
| 4.3 (Chemical Test-SS304) |
5000.0 |
|
| 4.4 (Dimension of Conductor) |
1000.0 |
|
|
| 1986 |
National Test House (NR), Ghaziabad
| IEC 62561-2 (2018) - Lightning Protection System components (LPSC) - Part 2: Requirements for conductors and earth electrodes |
Lightning Protection System components (LPSC) - Part 2: Requirements for conductors and earth electrodes |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
| 1987 |
National Test House (WR), Mumbai
| IS 1130 (Marble) (1969) - Marble |
Marble |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 7 (i) (Moisture Absorption, in %) |
1000.0 |
|
| 7 (ii) (Scratch hardness on Moh's scale) |
2000.0 |
|
| 7 (iii) (Specific Gravity) |
1000.0 |
|
| Part 7/8 of IS 13630 (Resistance to stain) |
2000.0 |
|
| Part 7/8 of IS 13630 (Resistance to Household Chemicals) |
1000.0 |
|
| Part 7/8 of IS 13630 (Resistance to Acid and Alkalies) |
2000.0 |
|
|
| 1988 |
National Test House (ER), Kolkata
| IS 2141 (2000) - Hot dip galvanized stay strand - Specification (Fourth Revision) |
Hot dip galvanized stay strand - Specification (Fourth Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 4 (Sulphur) |
500.0 |
|
| 4 (Phosphorus) |
500.0 |
|
| 6.2 (Breaking Force of Single Wire) |
2000.0 |
|
| 7 (Freedom from defect) |
1000.0 |
|
| 8.1 (Wrapping Test of wire) |
1000.0 |
|
| 9.1 (Breaking Force of Strand) |
3000.0 |
|
| 9.1 (Elongation of Strand) |
1000.0 |
|
| 8.1 (Wire Diameter) |
1000.0 |
|
| 9.2 (Mass of Zinc Coating) |
2000.0 |
|
|
| 1989 |
National Test House (SR), Chennai
| IS 9162 (1979) - Methods of tests for epoxy resins, hardeners and epoxy resin compositions for floor topping |
Methods of tests for epoxy resins, hardeners and epoxy resin compositions for floor topping |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 3 (Amine value) |
2000.0 |
|
| 6 (Specific gravity) |
1200.0 |
|
|
| 1990 |
National Test House (ER), Kolkata
| IS 398 Part 2 (2025) - ALUMINIUM CONDUCTORS FOR OVERHEAD TRANSMISSION PURPOSES |
ALUMINIUM CONDUCTORS FOR OVERHEAD TRANSMISSION PURPOSES |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 3.3 (Direction of Lay) |
1000.0 |
|
| 3.3 (Measurement of Diameter of individual Aluminum Wires) |
3500.0 |
|
| 13.2 (Measurement of Diameter of Galvanized Steel Wires) |
1000.0 |
|
| 13.3 (Breaking Load Test of Wire) |
7000.0 |
|
| 13.4 (Ductility Test) |
1000.0 |
|
| 13.5 (Wrapping Test for Aluminum Wire) |
1000.0 |
|
| 13.6 (Resistance Test) |
2000.0 |
|
| 13.7 (Galvanizing Test) |
2000.0 |
|
| 13.8 (Lay Ratio) |
1000.0 |
|
| 7.1 (Freedom from defect) |
1000.0 |
|
| 9.2 (Joints in Aluminium Stranded Wires (Visual Examination)) |
1000.0 |
|
| Annexure A-3 & Table 3 (Approximate breaking load of conductors) |
2000.0 |
|
|
| 1991 |
National Test House (WR), Mumbai
| Custom:PCC - PCC |
PCC |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (1) |
- |
|
| 3.1 (Total Incidental Elements (Mo+V+Al+Nb) (% by mass)) |
- |
|
|
| 1992 |
National Test House (WR), Mumbai
| Uninterruptible power systems (UPS) - Method of specifying the performance and test requirements - Test as per Manufacture Specification |
Test as per Manufacture Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (1kVA UPS Test as per Manufacture Specification) |
10000.0 |
|
| 8 (Scientist Charges for Onsite Testing per day) |
5000.0 |
|
|
| 1993 |
National Test House (ER), Kolkata
| IS 10647 (1983) - Specification for wheel bearing grease |
Specification for wheel bearing grease |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 2.3 (Consistency of the grease at 25+/- 0.5 degree C, 60 strokes) |
1200.0 |
|
| 2.3 (Drop Point) |
1200.0 |
|
| 2.3 (Copper strip corrosion test at 100 degree C for 24 hours) |
1200.0 |
|
| 2.3 (Water Content) |
1200.0 |
|
| 2.3 (consistency of grease, 25+/- 0.5 degree, unworked penetration) |
1200.0 |
|
| 2.3 (consistency of grease, 25+/- 0.5 degree, 10000 strokes) |
1200.0 |
|
|
| 1994 |
National Test House (NR), Ghaziabad
| TI/SPC/OHE/CW/0971 - Hard drawn grooved copper(HDGC) contact Wire for Electrical Traction (Drawn out of continuous Cast copper wire Rod)
. |
Hard drawn grooved copper(HDGC) contact Wire for Electrical Traction (Drawn out of continuous Cast copper wire Rod)
. |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 9.1.1 (Visual Examination) |
1000.0 |
|
| 9.1.2 (Dimension) |
2000.0 |
|
| 9.1.3 (Weight) |
1500.0 |
|
| 9.1.4 (Resistance/km at 20 Deg. C) |
3000.0 |
|
| 9.1.5 (Brinell Hardness) |
2000.0 |
|
| 9.1.6 (Tensile Strength) |
2000.0 |
|
| 9.1.8 (Bending Test) |
1000.0 |
|
| 9.1.9 ((Cu+Ag)) |
2000.0 |
|
| 9.1.10 (Micro structure Examination) |
3000.0 |
|
| 9.1.7 (Elongation at Gauge Length 200 mm) |
1000.0 |
|
|
| 1995 |
National Test House (NER), Guwahati
| IS 16415 (2015) - Composite cement |
Composite cement |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 7 (Compressive strength,72±1 h) |
1000.0 |
|
| 7 (Compressive strength,168±2 h) |
1000.0 |
|
| 7 (Compressive strength,672±4 h) |
1000.0 |
|
| 7 (Fineness) |
1000.0 |
|
| 7 (Setting time Initial) |
250.0 |
|
| 7 (Setting time,Final) |
250.0 |
|
| 7 (Soundness-Lechatlier method) |
500.0 |
|
| 7 (Soundness-autoclave method) |
1000.0 |
|
| 7 (Drying Shrinkage) |
1000.0 |
|
|
| 1996 |
National Test House (WR), Mumbai
| IS 15477:2019 - Adhesives for Use with Ceramic, Mosaic and Stone Tiles —Specification( First Revision) |
Adhesives for Use with Ceramic, Mosaic and Stone Tiles —Specification( First Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
| 1997 |
National Test House (NWR), Jaipur
| IS/IEC 61439-1 (2020) - Low-voltage switchgear and controlgear assemblies
Part 1: General rules |
Low-voltage switchgear and controlgear assemblies
Part 1: General rules |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Cl No. 10.9 (Dielectric properties (High Voltage Test)) |
20000.0 |
|
| Cl No. 10.10 (Temperature-rise) |
30000.0 |
|
|
| 1998 |
National Test House (NER), Guwahati
| IS 383 (2016) & CPWD Vol. I Specifications - Specification for Coarse & Fine Aggregate |
Specification for Coarse & Fine Aggregate |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6.3 (Sieve Analysis) |
2000.0 |
|
| 5.2.1 (Deleterious Material) |
2000.0 |
|
| Organic Impurities (Organic Impurities) |
1000.0 |
|
| 4 of 2386-IV (Aggregate Impact Value) |
1500.0 |
|
| 2.1 (Aggregate Crushing Value) |
1500.0 |
|
| 5 of 2386-IV (Aggregate Abrasion Value) |
1500.0 |
|
| 4 of 2386 Part 1 (Flakiness Index, %) |
1500.0 |
|
| 5 of IS 2386-I (Elongation Index, %) |
1500.0 |
|
| 4, 5 of IS 2386 (Combined Flakiness & Elongation Indices) |
3000.0 |
|
| CPWD Specs (Silt Content) |
1000.0 |
|
| MoRTH Specs (Fineness Modulus) |
500.0 |
|
| 5.5 (Soundness) |
2000.0 |
|
| 4.0 Bulking of Sand (Bulking of Sand) |
1000.0 |
|
| 3 of 2386-IV (Fine Value) |
1500.0 |
|
| 2386 Part 3 (Moisture Content) |
1000.0 |
|
| 2386 Part 3 (Water Absorption) |
1000.0 |
|
| 4.2 (Alkali Aggregate reactivity) |
3000.0 |
|
| 2386 Part 3 (Specific Gravity) |
500.0 |
|
| 2386 Part 3 (Bulk Density) |
1000.0 |
|
|
| 1999 |
National Test House (NR), Ghaziabad
| Valve Testing as per Test request - Valve Testing as per Test request |
Valve Testing as per Test request |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 0 (Hydrostatic Test of Body) |
5000.0 |
|
| 0 (Hydrostatic Test of Seat) |
2500.0 |
|
| 0 (Hydrostatic Test of Disc Strength) |
2500.0 |
|
| 0 (Measurement of Dimensions) |
2000.0 |
|
| 0 (Chemical composition, % by Mass) |
5000.0 |
|
|
| 2000 |
National Test House (ER), Kolkata
| IS 9537 : Part 3 (1983) - Specification for conduits for electrical installations: Part 3 rigid plain conduits of insulating meterials |
Specification for conduits for electrical installations: Part 3 rigid plain conduits of insulating meterials |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 11 (Resistance to Burning) |
5000.0 |
|
| 10 (Resistance to Heat) |
2000.0 |
|
| 9.5 (Collapse Test) |
2000.0 |
|
| 9.4 (Impact Test) |
2000.0 |
|
| 9.3 (Compression Test) |
2000.0 |
|
| 9.2 (Bending Test) |
2000.0 |
|
| 8 (Construction) |
1000.0 |
|
| 7.4 (Uniformity of Wall Thickness) |
1000.0 |
|
| - (-) |
- |
|
| 9.4 (Visual) |
1000.0 |
|
| 6.4 (Durability of Marking) |
500.0 |
|
|
| 2001 |
National Test House (SR), Chennai
| IS 10026 : Part 2 (1999) - Insulating varnishes containing solvents: Part 2 methods of tests (First Revision) |
Insulating varnishes containing solvents: Part 2 methods of tests (First Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Custom (Test results (Chemical)) |
6000.0 |
|
| Custom (Test results (Electrical)) |
15000.0 |
|
|
| 2002 |
National Test House (NR), Ghaziabad
| IS 3400 : Part 1 (2021) - Methods of Test for Vulcanized Rubber Part 1 Tensile Stress-Strain Properties |
Methods of Test for Vulcanized Rubber Part 1 Tensile Stress-Strain Properties |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| IS 3400 (Part-1) (Tensile Strength) |
2000.0 |
|
|
| 2003 |
National Test House (NWR), Jaipur
| IS/IEC 62271-102:2018 (2018) - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR
PART 102 ALTERNATING CURRENT DISCONNECTORS AND EARTHING SWITCHES |
HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR
PART 102 ALTERNATING CURRENT DISCONNECTORS AND EARTHING SWITCHES |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 7.102.6 (Testing of Mechanical Interlocking Devices) |
20000.0 |
|
| 7.105 (Tests to verify the proper functioning of the Position-indicating Device) |
20000.0 |
|
| 7.102.4/7.102.5 (Extended Mechanical Endurance Test) |
30000.0 |
|
| 5.104/5.105 (Terminal Load Test on Disconnector & Earth) |
20000.0 |
|
|
| 2004 |
National Test House (NWR), Jaipur
| IEC 60099-4:2014 (2014) - Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems |
Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6.16.2 (Bending Moment) |
20000.0 |
|
| 8.9.4.3 (Tensile Load Test (Pull Test)) |
20000.0 |
|
| 8.11 & 8.11.4.1 (Bending Moment Test(Cantilever Strength Test)/Mechanical Load Test/Breaking Load Test) |
20000.0 |
|
| 8.11 & 8.11.4.2 (Electric Test/Leakage Check & Partial Discharge test) |
20000.0 |
|
|
| 2005 |
National Test House (SR), Chennai
| IS 4722 - ROTATING ELECTRICAL
MACHINES |
ROTATING ELECTRICAL
MACHINES |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 30.2 (Insulation Résistance test before Dielectric test) |
5000.0 |
|
| 30.1 (HV test at rated voltage plus 1kV) |
3000.0 |
|
| 30.2.a (Insulation Résistance test after Dielectric test) |
5000.0 |
|
|
| 2006 |
National Test House (NR), Ghaziabad
| IS 245 - 2020 (2020) - TRICHLORO ETHYLENE TECHNICAL |
TRICHLORO ETHYLENE TECHNICAL |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Cl 1 Table 1 (Relative Density @ 27 Degree C) |
2000.0 |
|
| Cl 1 Table 1 (Residue on evaporation, mg/100 ml) |
2000.0 |
|
| Cl 1 Table 1 (Distillation yield between 86 and 88°C, the temperature being corrected for 760 mm Hg pressure) |
2000.0 |
|
| Cl 1 Table 1 (Alkalinity (as Na2CO3)) |
2000.0 |
|
| Cl 1 Table 1 (Resistance to corrosion) |
2000.0 |
|
|
| 2007 |
National Test House (ER), Kolkata
| ASME BPVC Section V SE 165 - Standard Practice for Liquid Penetrant Examination for General Industry |
Standard Practice for Liquid Penetrant Examination for General Industry |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Flaw detection by Liquid Penetrant Test) |
1000.0 |
|
|
| 2008 |
National Test House (ER), Kolkata
| ASME BPVC Section V SD 7091 - Standard practice for Non-destructive measurement of Dry Film Thickness of Non-magnetic Coating applied to ferrous metals and Non-magnetic, Non-conductive coating applied to Non-ferrous Metals |
Standard practice for Non-destructive measurement of Dry Film Thickness of Non-magnetic Coating applied to ferrous metals and Non-magnetic, Non-conductive coating applied to Non-ferrous Metals |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Dry Film Thickness) |
2000.0 |
|
|
| 2009 |
National Test House (NR), Ghaziabad
| IS 398 Part 2 (2025) - ALUMINIUM CONDUCTORS FOR OVERHEAD TRANSMISSION PURPOSES |
ALUMINIUM CONDUCTORS FOR OVERHEAD TRANSMISSION PURPOSES |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 3.3 (Direction of Lay) |
1000.0 |
|
| 3.3 (Measurement of Diameter of individual Aluminum Wires) |
3500.0 |
|
| 13.2 (Measurement of Diameter of Galvanized Steel Wires) |
1000.0 |
|
| 13.3 (Breaking Load Test of Wire) |
7000.0 |
|
| 13.4 (Ductility Test) |
1000.0 |
|
| 13.5 (Wrapping Test for Aluminum Wire) |
1000.0 |
|
| 13.5 (Wrapping Test for Galvanized Steel Wire) |
1000.0 |
|
| 13.6 (Resistance Test) |
2000.0 |
|
| 13.7 (Galvanizing Test) |
2000.0 |
|
| 13.8 (Lay Ratio) |
1000.0 |
|
| 7.1 (Freedom from defect) |
1000.0 |
|
| 9.2.1 (Joints in Aluminium Stranded Wire) |
1000.0 |
|
| 0 (Mechanical Test As per Annexure) |
6000.0 |
|
| 0 (Resistance Test) |
1000.0 |
|
| 0 (Galvanising test- Mass & Uniformity of Zinc Coating) |
1000.0 |
|
| 1 (Tensile strength and Elongation of Insulation) |
3000.0 |
|
| 1.1 (Shrinkage Test of Insulation) |
500.0 |
|
| 0 (Mechanical Test for 37wire As per Annexure) |
8000.0 |
|
|
| 2010 |
National Test House (ER), Kolkata
| IS 13043 (1991) - Covered manual metal arc welding electrodes - Determination of efficiency, metal recovery and deposition co - Efficien |
Covered manual metal arc welding electrodes - Determination of efficiency, metal recovery and deposition co - Efficien |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Metal Recovery Test-Effective Electrode Efficiency) |
3000.0 |
|
|