| 1861 |
National Test House (NR), Ghaziabad
| IS 2347 (2023) - Domestic pressure cooker - Specification (Sixth Revision) |
Domestic pressure cooker - Specification (Sixth Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 4.1 (Capacity) |
500.0 |
|
| 8.1 (Air Pressure of domestic pressure cooker) |
1000.0 |
|
| 8.2 (Proof Pressure of domestic pressure cooker) |
2000.0 |
|
| 8.3 (Operating pressure for Pressure Regulating Device) |
1000.0 |
|
| 8.4.1 Annex-H cl. No. H-1.1 (Operating pressure of Safety Pressure Relief Device for destructible device) |
1000.0 |
|
| 8.6.1 (Removal of Lid under Pressure (For Outer Lid Cooker)) |
1000.0 |
|
| 8.6.2 (Removal of Lid under Pressure (For Inner Lid Cooker)) |
1000.0 |
|
| 8.5 (Bursting Pressure Test) |
3000.0 |
|
| 7.4 Annex-E cl. No. E-4 (Micro Vickers Hardness for body) |
2000.0 |
|
| 5.1 (Chemical Composition, % by mass.) |
6000.0 |
|
| 0 (Test Result as per Annexure.) |
20000.0 |
|
|
| 1862 |
National Test House (ER), Kolkata
| IS 6416:2022 - Methods for Measuring Case Depth of Steel |
Methods for Measuring Case Depth of Steel |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 7 (Case Depth of Steel by Macrostructure Method) |
3000.0 |
|
| 8 (Case Depth of Steel by Microstructure Method) |
3000.0 |
|
|
| 1863 |
National Test House (ER), Kolkata
| ASTM E114-20 - Standard Practice for Ultrasonic Pulse-Echo Straight Beam Contact Testing |
Standard Practice for Ultrasonic Pulse-Echo Straight Beam Contact Testing |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Ultrasonic Pulse-Echo Straight Beam Contact Testing) |
1000.0 |
|
|
| 1864 |
National Test House (ER), Kolkata
| ASTM E164-19 - Standard Practice for Contact Ultrasonic Testing of Weldments |
Standard Practice for Contact Ultrasonic Testing of Weldments |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Ultrasonic Testing of Weldments) |
1000.0 |
|
|
| 1865 |
National Test House (ER), Kolkata
| ASTM E 94-17 - Standard Guide for Radiographic Examination using Industrial Radiographic Film |
Standard Guide for Radiographic Examination using Industrial Radiographic Film |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Radiographic Examination using Industrial Radiographic Film) |
1000.0 |
|
|
| 1866 |
National Test House (ER), Kolkata
| ASTM E1032-19 - Standard Practice for Radiographic Examination of Weldments using Industrial X-Ray Film |
Standard Practice for Radiographic Examination of Weldments using Industrial X-Ray Film |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Radiographic Examination of Weldments) |
1000.0 |
|
|
| 1867 |
National Test House (ER), Kolkata
| ASTM E1030-15 - Standard Practice for Radiographic Examination of Metallic Castings |
Standard Practice for Radiographic Examination of Metallic Castings |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Radiographic Examination of Metallic Castings) |
1000.0 |
|
|
| 1868 |
National Test House (ER), Kolkata
| IS 3664:1981 - Code of practice for ultrasonic pulse echo testing by contact and immersion methods (first revision) |
Code of practice for ultrasonic pulse echo testing by contact and immersion methods (first revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Ultrasonic Pulse Echo Testing by Contact Method) |
1000.0 |
|
|
| 1869 |
National Test House (ER), Kolkata
| ASTM E709-15 - Standard Guide for Magnetic Particle Testing |
Standard Guide for Magnetic Particle Testing |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Magnetic Particle Testing) |
1000.0 |
|
|
| 1870 |
National Test House (ER), Kolkata
| ASTM E112-13 - Standard Test Method for Determining Average Grain Size |
Standard Test Method for Determining Average Grain Size |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 10 (Determining Average Grain Size) |
3000.0 |
|
|
| 1871 |
National Test House (ER), Kolkata
| IS 7754 (Part 1) (2022) - Microstructure of Cast Iron-Graphite Classification by visual analysis |
Microstructure of Cast Iron-Graphite Classification by visual analysis |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6 (Determination of Graphite Shape and Distribution) |
3000.0 |
|
|
| 1872 |
National Test House (ER), Kolkata
| IS 7754 (2022) - Microstructure of Cast Iron-Graphite Classification by Visual analysis |
Microstructure of Cast Iron-Graphite Classification by Visual analysis |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Microstructure of Graphite in Cast Iron) |
3000.0 |
|
|
| 1873 |
National Test House (SR), Chennai
| IS:16353-2015 -CLINKER - PORTLAND CEMENT CLINKER |
PORTLAND CEMENT CLINKER |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| custom (Compressive strength- 24±1h[on the lines of IS 4031(6)]) |
1000.0 |
|
| 6.1-Table 2 (Compressive strength-72±1h[ IS 4031(6)]) |
1000.0 |
|
| 6.1-Table 2 (Compressive strength-168±2h[ IS 4031(6)]) |
1000.0 |
|
| 6.1-Table 2 (Compressive strength-672±4h[ IS 4031(6)]) |
1000.0 |
|
| custom (Consistency[IS 4031(4)]) |
500.0 |
|
| Table 1 Cl 5 (Ratio of percentage of Alumina to that of Iron Oxide) |
1000.0 |
|
| Table 1 Cl 5 (Ratio of percentage of lime to percentages of silica, alumina and iron oxide) |
1000.0 |
|
| Table 1 Cl 5 (Total sulphur content calculated as sulphuric anhydride (SO3)) |
500.0 |
|
| Table 1 Cl 5 (Free lime, percent by mass,) |
1500.0 |
|
| Table 1 Cl 5 (Chloride content, percent by mass,) |
200.0 |
|
| Table 1 Cl 5 (Magnesia (as MgO), percent by mass) |
1500.0 |
|
| Table 1 Cl 5 (Insoluble residue, percent by mass) |
500.0 |
|
| Table 1 Cl 5 (Total loss on ignition , Percent by mass) |
500.0 |
|
| Table 1 Cl 5 (Silica (as SiO2), Percent by mass) |
500.0 |
|
| Table 1 Cl 5 (Aluminium Oxide (as Al2O3), Percent by mass) |
500.0 |
|
| Table 1 Cl 5 (Iron Oxide (as Fe2O3), Percent by mass) |
500.0 |
|
| Table 1 Cl 5 (Alkali content (as Na2O), percent by mass) |
500.0 |
|
| Table 1 Cl 5 (Alkali Content (as K2O). Percent by mass) |
500.0 |
|
| Table 1 Cl 5 (Calcium Oxide (as CaO), Percent by mass) |
1000.0 |
|
| 6.1 (Fineness: [IS 4031(2)]) |
1000.0 |
|
| 6.1-Table 2 (Soundness-Le-Chatelier method :IS 4031(3)) |
500.0 |
|
| 6.1-Table 2 (Soundness-Autoclave method [IS 4031(3)]) |
1000.0 |
|
| 6.1-Table 2 (Setting Time-Initial setting time[IS 4031(5)]) |
500.0 |
|
| 6.1-Table 2 (Setting Time-Final setting time: [IS 4031(5)]) |
500.0 |
|
|
| 1874 |
National Test House (SR), Chennai
| IS 16353 (2015) - Portland Cement Clinker - Specification |
Portland Cement Clinker - Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
| 1875 |
National Test House (NER), Guwahati
| IS 9103:1999 - CONCRETE ADMIXTURES - SPECIFICATION ( First Revision ) |
CONCRETE ADMIXTURES - SPECIFICATION ( First Revision ) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
| 1876 |
National Test House (NER), Guwahati
| Customer Specification NTH ER CONCRETE ADMIXTURES (IS 9103) (1991 RA 2018) - Customer Specification NTH ER CONCRETE ADMIXTURES
(IS 9103) |
Customer Specification NTH ER CONCRETE ADMIXTURES
(IS 9103) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
| 1877 |
National Test House (NER), Guwahati
| IS 1237 (2012) - Cement Concrete Flooring Tiles - Specification |
Cement Concrete Flooring Tiles - Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 12.6 (Wet transverse strength-Annex F of IS 1237:2012) |
2000.0 |
|
| 12.5 (Water Absorption-Annex E of IS 1237:2012) |
1000.0 |
|
| 10 (General Quality-IS 1237:2012) |
100.0 |
|
| 12.7 (Resistance to wear-Annex G of IS 1237:2012) |
2500.0 |
|
| 8.3 & Table2 (The thickness of Wearing Layer-IS 1237:2012) |
100.0 |
|
| 7, 8.2 & Table1 (Thickness & Tolerances-IS 1237:2012) |
100.0 |
|
| 7 & 8.1, Table1 (Dimensions & Tolerances-IS 1237:2012) |
200.0 |
|
| 11 (Finish-IS 1237:2012) |
200.0 |
|
| 12.4 (Straightness-Annex D of IS 1237:2012) |
500.0 |
|
| 12.3 (Perpendicularity-Annex C of IS 1237:2012) |
500.0 |
|
| 12.2 (Flatness-Annex B of IS 1237:2012) |
500.0 |
|
|
| 1878 |
National Test House (ER), Kolkata
| CUSTOM - Chemical Composition of Galvalume Sheet |
Chemical Composition of Galvalume Sheet |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Aluminium, % by weight) |
1200.0 |
|
| 2 (Zinc, % by weight) |
1200.0 |
|
| 3 (Silicon, % by weight) |
1200.0 |
|
|
| 1879 |
National Test House (NR), Ghaziabad
| NTH/NR/RPPT/Nylon Bush (2024) - Nylon Bush |
Nylon Bush |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| FTIR Method (Identification of Material) |
3000.0 |
|
| On the lines of ASTM D792 (Specific Gravity) |
1000.0 |
|
| On the lines of ASTM D2240 (Hardness, Shore'D') |
1000.0 |
|
| On the Lines of ASTM D570 (Water Absorption) |
1000.0 |
|
| Firm's Requirement (Melting Point) |
1000.0 |
|
|
| 1880 |
National Test House (SR), Chennai
| IEC 60214-1:2014 - Tap-changers – Part 1: Performance requirements and test methods |
Tap-changers – Part 1: Performance requirements and test methods |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Cl.no: 5.2.6.2 Mechanical endurance test as per IEC 60214-1) |
20000.0 |
|
| 2 (Pressure and vacuum tests as per clause 5.2.6.5 of IEC 60214-1 2014) |
5000.0 |
|
| 3 (Mechanical load test as per IEC 60214-1 2014 clause 6.2.1) |
15000.0 |
|
| 4 (Overrun test as per IEC 60214-1 2014 clause 6.2.2) |
1500.0 |
|
| 5 (Five Witness charges) |
25000.0 |
|
| 6 (Drawing Verification) |
3000.0 |
|
| 5.2.2 & 7.2.2 (Temperature Rise of Contact) |
10000.0 |
|
| 5.2.6.3 (Sequence Test) |
5000.0 |
|
| 5.2.5.1 (Transition Impedance test) |
7000.0 |
|
|
| 1881 |
National Test House (WR), Mumbai
| IS 16205 (Part 24) : 2017 - CONDUIT SYSTEMS FOR CABLE MANAGEMENT |
CONDUIT SYSTEMS FOR CABLE MANAGEMENT |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 10.2 (Compression Test) |
2000.0 |
|
| 10.3 (Impact Test) |
2000.0 |
|
| 13 (Fire hazard(Spread of Fire)) |
5000.0 |
|
|
| 1882 |
National Test House (NR), Ghaziabad
| IS 17953 (2023) - uPVC Profiles for Windows and Doors - Specification |
uPVC Profiles for Windows and Doors - Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5.2 (Appearance) |
1000.0 |
|
| 5.3.1 (Dimensions and Tolerances) |
2000.0 |
|
| 5.3.2 (Wall Thickness of Main Profile) |
1000.0 |
|
| 5.3.4 (Straightness) |
1000.0 |
|
| 5.4 (Mass of Profile) |
1000.0 |
|
| 5.5 (Heat Reversion) |
2000.0 |
|
| 5.6 (Resistance to Impact on Falling Mass) |
3000.0 |
|
| 5.7 (Heat Ageing) |
2000.0 |
|
| 5.11 (Density) |
1000.0 |
|
| Annexure B-3.1 (Vicat Softening Temperature) |
2000.0 |
|
| Annexure B-3.2 (Flexural Modulus of Elasticity) |
2000.0 |
|
|
| 1883 |
National Test House (ER), Kolkata
| IRS:S88/2004 (2004) - LOW MAINTENANCE LEAD ACID STATIONARY SECONDARY CELLS FOR S&T INSTALLATIONS |
LOW MAINTENANCE LEAD ACID STATIONARY SECONDARY CELLS FOR S&T INSTALLATIONS |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 7.2 (Verification of constructional Requirements) |
500.0 |
|
| 7.3 (Verification of Marking) |
500.0 |
|
| 7.4 (Verification of dimension) |
500.0 |
|
| 7.5 (Test for Capacity) |
20000.0 |
|
| 7.6 (Test for loss of capacity on storage) |
10000.0 |
|
| 7.7 (Endurance Test) |
45000.0 |
|
| 7.8 (Ampere Hour & Watt Hour Efficiency Test) |
20000.0 |
|
| 7.9 (Test for voltage during discharge) |
5000.0 |
|
| 7.10 (Life Test) |
240000.0 |
|
| 7.11 (Storage Test) |
10000.0 |
|
| 7.12 (Water loss Test) |
5000.0 |
|
| 7.13 (Equilibrium Float Current Test) |
5000.0 |
|
| 7.14 (Sulphation Test) |
20000.0 |
|
| 7.15 (Air Pressure Test on containers consisting of finished cell/Battery) |
10000.0 |
|
|
| 1884 |
National Test House (SR), Chennai
| IS 303 (1989) - Plywood for General Purposes - |
Plywood for General Purposes - |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 8 & Table 3 (Dimensions and Tolerances-IS 303:1989, Annex C) |
2000.0 |
|
| 9 (Workmanship & Finish-IS 303:1989) |
500.0 |
|
| 11.3 (Moisture content-IS 1734 (Part 1):1983) |
1000.0 |
|
| 11.4 & Table 4 (Static Bending Strength-IS 1734 (Part 11):1983) |
3000.0 |
|
| 11.2.1 (Glue Adhesion-Water Resistance Test- IS 303:1989 & IS 1734 (Part 5):1983) |
2000.0 |
|
| 11.2.2 (Glue Adhesion-Mycological Test -IS 1734 (Part 7):1983 & IS 1734 (Part 5):1983) |
1500.0 |
|
| 5, Table 1 & 2 (Classification by Appearance-IS 303:1989) |
2000.0 |
|
|
| 1885 |
National Test House (WR), Mumbai
| IS 1060(Part 1):1966 - Paper |
Paper |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| - (Breaking length ,CD) |
2000.0 |
|
| - (Breaking length, MD) |
2000.0 |
|
|
| 1886 |
National Test House (NWR), Jaipur
| IS 9385 (1980) - SPECIFICATION FOR HIGH VOLTAGE FUSES
(EXPULSION AND SIMILAR FUSES) |
SPECIFICATION FOR HIGH VOLTAGE FUSES
(EXPULSION AND SIMILAR FUSES) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 4.6 (Temperature Rise Test) |
20000.0 |
|
|
| 1887 |
National Test House (NER), Guwahati
| IS 15366 (2003) - Dolomite for paint industry - Specification |
Dolomite for paint industry - Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 4.2 (Magnesium Carbonate) |
1000.0 |
|
| 4.2 (Calcium Carbonate) |
1000.0 |
|
| 4.2 (Acid insoluble residue) |
1000.0 |
|
| 4.2 (pH Value) |
1000.0 |
|
| 4.2 (Volatile matter) |
1000.0 |
|
| 4.2 (Loss on Ignition, percent by mass) |
1000.0 |
|
|
| 1888 |
National Test House (ER), Kolkata
| ICF/MD/SPEC-091 ISSUE STATUS : 01 REV.N0 : 02 - SPECIFICATION FOR POWDER COATED ITEMS/ COMPONENTS USED IN RAILWAY PASSENGER COACHES |
SPECIFICATION FOR POWDER COATED ITEMS/ COMPONENTS USED IN RAILWAY PASSENGER COACHES |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6.0 TYPE TEST sr no 1 (Protection against corrosion FOR 100 HOURS
IS:101 (Part-6-Sec.1 )) |
5000.0 |
|
| 6.0 TYPE TEST:SR No 2 (Protection against humidity
IS:101 (Part 6/sec1)) |
2500.0 |
|
| 6.0 Type Test SR No 3 (Resistance to Heat double-bake schedule 16 hrs
IS: 101 (Part-7/Sec.3) as per Clause 8 and
8.1.1 restricted to250degC) |
2500.0 |
|
| 6.0 Type test SR No 4 (Colour Fastness to light(100 hours)
As per clause D 3.2.3 of1S:8662 & IS: 133 Sl.N0.V11 Table.l Apparatus: Xenon Arc accelerated weatherometer in the region of 280-315nm) |
5000.0 |
|
|
| 1889 |
National Test House (NWR), Jaipur
| IS/IEC:60529-2001 & IEC 61439-1: 2009 - IP-42 Class of protection test
Drawing Verification
Power Frequency Voltage withstand test after IP test
Dielectric Properties test after IP test |
IP-42 Class of protection test
Drawing Verification
Power Frequency Voltage withstand test after IP test
Dielectric Properties test after IP test |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
| 1890 |
National Test House (NWR), Jaipur
| IEC 61439-1: 2009 & IS/IEC:60529-2001 - IP-65 Class of protection test
Drawing Verification
Power Frequency Voltage withstand test before and after IP test
Dielectric Properties test before and after IP test |
IP-65 Class of protection test
Drawing Verification
Power Frequency Voltage withstand test before and after IP test
Dielectric Properties test before and after IP test |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 9.2 (Temperature Rise Test) |
20000.0 |
|
|