| 1831 |
National Test House (SR), Chennai
| IS 1060 - METHODS OF SAMPLING AND TEST FOR PAPER AND ALLIED PRODUCTS |
METHODS OF SAMPLING AND TEST FOR PAPER AND ALLIED PRODUCTS |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
| 1832 |
National Test House (ER), Kolkata
| CUSTOM - Texture Paint |
Texture Paint |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Volume solid) |
2000.0 |
|
| 2 (Non- Volatile content) |
1200.0 |
|
| 3 (Dry Film Thickness) |
1200.0 |
|
| 5 (pH) |
1200.0 |
|
| 6 (Viscosity) |
1200.0 |
|
| 7 (Theoretical Coverage Capacity) |
1200.0 |
|
| 8 (Pull Of adhesion test) |
3500.0 |
|
| 9 (Scratch Hardness Test (96 hrs Air drying + 2000 grams Load)) |
1200.0 |
|
| 10 (Salt Spray test (96 Hrs)) |
4800.0 |
|
| 4 (Drying time (Touch dry and Hard Dry)) |
1200.0 |
|
|
| 1833 |
National Test House (WR), Mumbai
| Custom specification for General Chemical -NTH WR - Custom specification for General Chemical -NTH WR |
Custom specification for General Chemical -NTH WR |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| - (Identification of material) |
2000.0 |
|
| - (Volatile Organic Compounds) |
4000.0 |
|
| - (% Retention on 63 Micron sieve) |
1500.0 |
|
| - (Volume of a Cup) |
2000.0 |
|
|
| 1834 |
National Test House (WR), Mumbai
| Custom specification for Fire & Flammability - Custom specification for Fire & Flammability- NTH WR chemical |
Custom specification for Fire & Flammability- NTH WR chemical |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| - (Flammability) |
3000.0 |
|
| - (Fire Resistance) |
3000.0 |
|
|
| 1835 |
National Test House (NR), Ghaziabad
| As per Customer specification - Heat Resistance Test 120 degree Celsius for 3 hours. As per Appendix -II Ease of Cleaning (Rating of 8 and above) As per Appendix -III |
Heat Resistance Test 120 degree Celsius for 3 hours. As per Appendix -II Ease of Cleaning (Rating of 8 and above) As per Appendix -III |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 28594 (Heat Resistance Test 120 degree Celsius for 3 hours.) |
3000.0 |
|
|
| 1836 |
National Test House (WR), Mumbai
| Customized Specification For Printed Paper - Customized Specification For Printed Paper |
Customized Specification For Printed Paper |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| - (GSM (Gram Per Square Meter)) |
1000.0 |
|
|
| 1837 |
National Test House (ER), Kolkata
| Thermal Ageing & Environmental Test for RTD - Thermal Ageing & Environmental Test for RTD |
Thermal Ageing & Environmental Test for RTD |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| A1 (Thermal Ageing & Environmental Test for RTD) |
20000.0 |
|
|
| 1838 |
National Test House (NR), Ghaziabad
| 516 (2018 and 2020) - Hardened Concrete —Methods of Test Part 5 Non-destructive Testing of Concrete |
Hardened Concrete —Methods of Test Part 5 Non-destructive Testing of Concrete |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Part 5 Section 4 Cl 6 (Rebound Hammer Test) |
4000.0 |
|
|
| 1839 |
National Test House (ER), Kolkata
| IS 894 (2023) - SPECIFICATION FOR HANDLOOM WOOL BLANKETS BRICK RED |
SPECIFICATION FOR HANDLOOM WOOL BLANKETS BRICK RED |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Table 2 (Fibre Composition) |
2000.0 |
|
| Table-1 (Ends per inch) |
1000.0 |
|
| Table-1 (Picks per inch) |
1000.0 |
|
| Table-1 (Breaking Load, kgs) |
2000.0 |
|
| Table-1 (Weight per square meter (GSM)) |
1000.0 |
|
| Table-1 (Type of Weaves) |
1000.0 |
|
| Table 2 (Colour fastness to Light) |
3000.0 |
|
| Table 2 (Colour fastness to Washing) |
2000.0 |
|
| Table 2 (Colour fastness to Rubbing) |
2000.0 |
|
|
| 1840 |
National Test House (NR), Ghaziabad
| IS 9385 (1980) - SPECIFICATION FOR HIGH VOLTAGE FUSES
(EXPULSION AND SIMILAR FUSES) |
SPECIFICATION FOR HIGH VOLTAGE FUSES
(EXPULSION AND SIMILAR FUSES) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
| 1841 |
National Test House (NR), Ghaziabad
| FCO 1985 NANO FERTILISER - The Fertiliser (Inorganic, Organic or Mixed) (Control) Order 1985 (As amended up to October 2024) |
The Fertiliser (Inorganic, Organic or Mixed) (Control) Order 1985 (As amended up to October 2024) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Schedule VII Clause 20 D(1) (As per Annexure (Attached)-NON NABL) |
7500.0 |
|
|
| 1842 |
National Test House (NR), Ghaziabad
| FCO 1985 (as amended upto November 2023) - FCO 1985 (as amended upto October 2024) |
FCO 1985 (as amended upto October 2024) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Schedule 1 Part A (ALL tests as per FCO-1985(PLEASE SEE THE ANNEXURE)-NABL (Schedule 1 Part A (ALL tests as per FCO-1985(PLEASE SEE THE ANNEXURE)-NABL) |
7000.0 |
|
| Schedule 1 Part A (ALL tests as per FCO-1985(PLEASE SEE THE ANNEXURE)-NON-NABL (Schedule 1 Part A (ALL tests as per FCO-1985(PLEASE SEE THE ANNEXURE)-NON-NABL) |
7000.0 |
|
|
| 1843 |
National Test House (ER), Kolkata
| IS 9968 (Part-1) 1988 (1988) - SPECIFICATlON FOR ELASTOMER INSULATED CABLES |
SPECIFICATlON FOR ELASTOMER INSULATED CABLES |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 21.2.(a) (Annealing Test (For Copper)) |
1000.0 |
|
| 21.2.(b) (Tensile test ( for alummrum )) |
1000.0 |
|
| 21.2.(c) (wrapping test ( for aluminium );) |
500.0 |
|
| 21.2.(d) (Conductor resistance test) |
1500.0 |
|
| 21.2.(e) (Test for thickness of insulation and sheath.and overall diameter ( where specified )) |
1000.0 |
|
| 21.2.(f) (Tensile strength and elongation at break of insulation and sheath) |
1500.0 |
|
| 21.2.(g) (Hot set test for insulation and sheath) |
1000.0 |
|
| 21.2.(h) (High voltage test) |
3000.0 |
|
| 21.2.(i) (Insulation resistance test) |
2000.0 |
|
| - (Test on 2nd core) |
2000.0 |
|
| - (Test on 3rd core) |
2000.0 |
|
|
| 1844 |
National Test House (ER), Kolkata
| IS:1554 ( Part 1 ) - 1988 (1988) - SPECIFICATION FOR PVC INSULATED ( HEAVY DUTY ) ELECTRIC CABLES |
SPECIFICATION FOR PVC INSULATED ( HEAVY DUTY ) ELECTRIC CABLES |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 15.1(a).(1),15.2(a) (Annealing test ( for copper )) |
1000.0 |
|
| 15.2(b),15.1(a).(2) (Tensile test ( for aluminium )) |
1000.0 |
|
| 15.1(a).(3),15.2(c) (Wrapping test ( for aluminium )) |
500.0 |
|
| 15.1(a).(4),15.2(d),15.3(a) (Conductor resistance test) |
2000.0 |
|
| 15.2(e),15.1(c) (Test for thickness of insulation and sheath) |
1000.0 |
|
| 15.2(f), (Tensile strength and elongation at break of insulation and sheath) |
1000.0 |
|
| 15.2(g),15.1(e) (Insulation resistance test) |
1500.0 |
|
| 15.2(h),15.1(g) (High voltage test at room temperature) |
1000.0 |
|
| 15.1.1 , 15.2.1 (Oxygen index test) |
5000.0 |
|
| 15.1.1 , 15.2.1 (Temperature index) |
5000.0 |
|
| 15.1.1 , 15.2.1 (Flame retmdance test on single cable) |
5000.0 |
|
| 15.1.1 (Flame retardance test on bunched cables) |
5000.0 |
|
| 15.1.1 , 15.2.1 (Test for halogen acid gas evolution) |
5000.0 |
|
| 15.1.1 , 15.2.1 (Smoke density) |
5000.0 |
|
| 15.1(b) (Test for armouring wires/strips-Dimension) |
1000.0 |
|
| 15.1(b) (Test for armouring wires/strips - Tensile strength) |
1000.0 |
|
| 15.1(b) (Test for armouring wires/strips - Elongation at break) |
1000.0 |
|
| 15.1(b) (Test for armouring wires/strips - Torsion test for round wires) |
1000.0 |
|
| 15.1(b) (Test for armouring wires/strips - Winding test for formed wires) |
1000.0 |
|
| 15.1(b) (Test for armouring wires/strips - Uniformity of zinc coating) |
1000.0 |
|
| 15.1(b) (Test for armouring wires/strips - Mass of zinc coating) |
2000.0 |
|
| 15.1(b) (Test for armouring wires/strips - Resistivity) |
2000.0 |
|
| 15.1(d) (Physical tests for insulation and outer sheath: - Tensile strength and elongation at break) |
1500.0 |
|
| 15.1(d) (Physical tests for insulation and outer sheath: - Ageing in air oven) |
2000.0 |
|
| 15.1(d) (Physical tests for insulation and outer sheath: - Shrinkage test) |
500.0 |
|
| 15.1(d) (Physical tests for insulation and outer sheath: - Hot deformation) |
500.0 |
|
| 15.1(d) (Physical tests for insulation and outer sheath: - Loss of mass in air oven) |
1500.0 |
|
| 15.1(d) (Physical tests for insulation and outer sheath: - Heat shock test) |
500.0 |
|
| 15.1(d) (Physical tests for insulation and outer sheath: - Thermal stability) |
1000.0 |
|
| 15.1(f) (High voltage test ( water immersion test )) |
3000.0 |
|
| 15.1(h) (Flammability test) |
500.0 |
|
| - (Test on 2nd core) |
2000.0 |
|
| - (Test on 3rd core) |
2000.0 |
|
| - (Test on 4th core) |
2000.0 |
|
|
| 1845 |
National Test House (NWR), Jaipur
| IS: 1708 (Parts 1 to 18) : 1986 - Methods of Testing of Small Clear Specimens of Timber [Extra] |
Methods of Testing of Small Clear Specimens of Timber |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Part 1,Clause 4 (Moisture Content) |
1000.0 |
|
| Part 2,Clause 4.1.a (Specific gravity) |
500.0 |
|
| Part 8,Clause 4.1.ii (Compressive strength-Parallel to grain
[Compressive stress at maximum load]) |
1500.0 |
|
| Part 5,Clause 4.2.ii (Equivalent fibre stress at maximum load ( modulus of rupture - M of R )) |
3000.0 |
|
|
| 1846 |
National Test House (NR), Ghaziabad
| EN 50386 (2010) - Brushings up to 1 kV and from 250A to 5kA for liquid filled transformers |
Brushings up to 1 kV and from 250A to 5kA for liquid filled transformers |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 3.5 (Power frequency withstand voltage) |
10000.0 |
|
| 3.6 (Dimensions) |
2000.0 |
|
| 3.7 (Cantilever load withstand test) |
3000.0 |
|
|
| 1847 |
National Test House (NWR), Jaipur
| IS 2266 (2019) - Steel Wire Ropes for General Engineering Purpose |
Steel Wire Ropes for General Engineering Purpose |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 4 (Diameter) |
1000.0 |
|
| 5 (Breaking Force) |
3000.0 |
|
|
| 1848 |
National Test House (NWR), Jaipur
| IS 2266 (2019) - Steel Wire Ropes for General Engineering Purpose —Specification |
Steel Wire Ropes for General Engineering Purpose —Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
| 1849 |
National Test House (NWR), Jaipur
| ISO 4427 (Part 1 & 2) - Polyethylene pipes and fittings for water supply |
Polyethylene pipes and fittings for water supply |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 3.1.1.13 (Wall Thickness) |
1000.0 |
|
| 4.2.1 (Colour) |
1000.0 |
|
| 7.2 (Hydrostatic strength at 20 deg.c for 100 hours) |
12000.0 |
|
| 7.2 (Hydrostatic strength at 80 deg.c for 165 hours) |
20000.0 |
|
| 8.2 (Elongation at Break) |
2000.0 |
|
| 8.2 (Longitudinal reversion) |
2000.0 |
|
| 8.2 (Melt Mass Flow Rate(MFR)) |
2000.0 |
|
| 8.2 (Oxidation Induction Time(OIT)) |
2000.0 |
|
| 3.1.1.5 (Mean Outside Diameter) |
1000.0 |
|
| 3.1.1.8 (Ovality) |
1000.0 |
|
|
| 1850 |
National Test House (NWR), Jaipur
| 15466 (2004) - RUBBER SEALS FOR HYDRAULIC GATES |
RUBBER SEALS FOR HYDRAULIC GATES |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 4.0 (Tests) |
10000.0 |
|
| 4.0 (Elongation at break (IS:3400 Part-1)) |
2000.0 |
|
| 4.0 (Tensile Strength (IS:3400 Part-1)) |
2000.0 |
|
| 4.0 (Mass of water absorbed (IS:3400 Part-6)) |
2000.0 |
|
|
| 1851 |
National Test House (NER), Guwahati
| IS 8419 : Part 1 (1977) - Requirements for filtration equipment: Part 1 filtration media - Sand and gravel |
Requirements for filtration equipment: Part 1 filtration media - Sand and gravel |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 3.1.1 (Silica) |
1000.0 |
|
| 3.1.4 (Loss on Ignition) |
1000.0 |
|
| 3.1.2 (Percentage of volume of sand (clay, slit, loam etc.)) |
1000.0 |
|
| 3.1.3 (Acid Soluble Matter) |
1000.0 |
|
| 4.1.3 (Acid Soluble Matter) |
1000.0 |
|
| 4.1.1 (Presence of Inpurities (%)(clay, sand, loam and organic)) |
1000.0 |
|
|
| 1852 |
National Test House (ER), Kolkata
| RDSO/SPN/TC/98/2011 Rev 0 (2011) - RDSO Specification for Surge Protective Devices for Telecommunication Equipments |
RDSO Specification for Surge Protective Devices for Telecommunication Equipments |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Cl 5.9 (Nominal Voltage Operation) |
3000.0 |
|
| Cl 5.9 (Maximum continuous operating voltage) |
3000.0 |
|
| Cl. 5.9 (Voltage Protection Level) |
5000.0 |
|
| Cl. 5.9 (Temperature Conditioning-Cold Test: Temperature: -10 deg C, Duration: 4 hours, Electrical Loading of Device:230V,50 Hz.) |
5000.0 |
|
| Cl. 5.9 (Temperature Conditioning-Dry Heat Test, Temperature: +60 deg C,Duration: 4 hours, Electrical Loading of Device: 230V,50 Hz) |
5000.0 |
|
| Cl. 5.9 (Temperature Conditioning-Damp Heat Test: Temperature: +60 deg C,Relative Humidity:95%,Duration: 4 hours, Electrical Loading of Device: 230V,50 Hz) |
5000.0 |
|
| Cl. 5.9 (Visual Indication) |
2000.0 |
|
| Cl. 5.9 (Degree of Protection-IP20(Protection against Electric Shock): Test Finger Diameter: 12 mm, Applied Force: 10 N, Application Point: Every possible accessible position.) |
7500.0 |
|
| Cl. 5.9 (Fire retardant Test as per UL94(Resistance to Flame & ignition):Flammability Test:) |
5000.0 |
|
|
| 1853 |
National Test House (ER), Kolkata
| Custom - Cement content |
Cement content |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Cement Content) |
5000.0 |
|
| 2 ((Cement : sand : aggregate) ratio) |
5000.0 |
|
|
| 1854 |
National Test House (ER), Kolkata
| MAINTENANCE INSTRUCTION NUMBER TI/MI/0050 - Rev. 1 - MAINTENANCE INSTRUCTION NUMBER TI/MI/0050 - Rev. 1 |
MAINTENANCE INSTRUCTION NUMBER TI/MI/0050 - Rev. 1 |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 4.0 (Breaking Strength) |
2000.0 |
|
| 5.0 (Retention of breaking strength after UV exposure) |
2000.0 |
|
| 5.0 (UV exposure (144 hrs)) |
7200.0 |
|
|
| 1855 |
National Test House (WR), Mumbai
| IS 4853 (1982) - Recommended practice for radiographic inspection of fusion welded butt joints in steel pipes (First Revision) |
Recommended practice for radiographic inspection of fusion welded butt joints in steel pipes (First Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| IS 4853 (Radiography) |
2000.0 |
|
|
| 1856 |
National Test House (WR), Mumbai
| Customized Specification For UPVC Fins 50mmx100mm. - Customized Specification For UPVC Fins 50mmx100mm. |
Customized Specification For UPVC Fins 50mmx100mm. |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| - (Density on the lines of ASTM D 792) |
1000.0 |
|
| - (Vicat Softening Point on the lines of ASTM D 1525) |
2000.0 |
|
| - (Heat reversion test @100 Deg. 60 min. on the lines of EN 479:2018) |
2000.0 |
|
| - (Tensile Strength as per ASTM D 638) |
2000.0 |
|
| - (Flexural Modulus as per ASTM D 790) |
3000.0 |
|
| - (Limiting Oxygen Index) |
5000.0 |
|
|
| 1857 |
National Test House (SR), Chennai
| CUS/SR/MECH-50 (2024) - Perforated Metal Sheet |
Perforated Metal Sheet |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1.0 (Dimension, mm) |
2000.0 |
|
| 2.0 (Percentage of perforated area, %) |
2000.0 |
|
| 3.0 (Mass of Zinc coating) |
2000.0 |
|
| 4.0 (Powder Coating Thickness, micron) |
2000.0 |
|
|
| 1858 |
National Test House (ER), Kolkata
| BP 22494 Rev No. 07 - Epoxy Glass Mat Laminated Sheets & Components Fire Retardant. |
Epoxy Glass Mat Laminated Sheets & Components Fire Retardant. |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 8.3 (Specific Gravity) |
1000.0 |
|
| 9.1 (Tensile Strength) |
2000.0 |
|
| 9.2 (Cross Breaking Strength) |
2000.0 |
|
| 9.4 (Compression Strength - Proof) |
2000.0 |
|
| 9.5 (Splitting Load) |
2000.0 |
|
| 8.3 (Specific Gravity) |
1000.0 |
|
| 9.1 (Tensile Strength) |
2000.0 |
|
| 9.2 (Cross Breaking Strength) |
2000.0 |
|
| 9.4 (Compression Strength - Proof) |
2000.0 |
|
| 9.5 (Splitting Load) |
2000.0 |
|
|
| 1859 |
National Test House (NR), Ghaziabad
| IS 15450 (2022) - Polyethylene/aluminium/polyethylene composite pressure pipes for hot and cold water supplies - Specification |
Polyethylene/aluminium/polyethylene composite pressure pipes for hot and cold water supplies - Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Clause 9.1 (Table 2) (Outside Diameter) |
500.0 |
|
| Clause 9.1 (Table 2) (Out of Roundness) |
500.0 |
|
| Clause 9.1 (Table 2) (Wall Thickness) |
500.0 |
|
| Clause 9.1 (Table 2) (Outer PE Layer Thickness) |
500.0 |
|
| 9.3 (Length of Pipe) |
500.0 |
|
| 10 (Visual Appearance) |
1000.0 |
|
| 11.1 (Density @27°C) |
1000.0 |
|
| 11.2 (Melt Flow Rate) |
2000.0 |
|
| 11.3 (Overall Migration) |
5000.0 |
|
| 11.4 (Oxidation Induction Time) |
2000.0 |
|
| 11.5 (Carbon Black Content) |
2000.0 |
|
| 11.5 (Carbon Black Dispersion) |
1000.0 |
|
| 11.9 (Apparent Tensile Strength) |
5000.0 |
|
| 11.10 (Burst Pressure Test) |
2000.0 |
|
| 11.11.1 (Short Term Hydrostatic Test) |
5000.0 |
|
| 11.11.2 (Long Term Hydrostatic Test) |
5000.0 |
|
|
| 1860 |
National Test House (WR), Mumbai
| IS 12701:1996 - Rotational Moulded Polyethylene Water Storage Tanks |
Rotational Moulded Polyethylene Water Storage Tanks |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| As per table 1 (Minimum Bottom Thickness) |
1000.0 |
|
| As per table 1 (Minimum Wall Thickness) |
1000.0 |
|
| 5.4 (Wall Thickness above effective height) |
1000.0 |
|
| 7.2 (Resistance to Impact) |
2000.0 |
|
| 7.4 (Tensile Strength) |
2000.0 |
|
| 7.5 (Flexural Modulus) |
2000.0 |
|
| 7.1 (Resistance to deformation) |
2000.0 |
|
|