| 1351 |
National Test House (WR), Mumbai
| MMDTS -22001 - Schedule of Technical Requirements for Anodized Aluminium Braille Stickers for Signage on Railway Coaches |
Schedule of Technical Requirements for Anodized Aluminium Braille Stickers for Signage on Railway Coaches |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| - (Abrasion Resistance) |
3000.0 |
|
| - (Acid Corrosion Resistance) |
1500.0 |
|
| - (Heat Resistance at 120 deg. C for 3 hours) |
1500.0 |
|
| - (Adhesion Between Basic and Braille Layers test) |
2000.0 |
|
| - (Stain Resistance Test) |
1000.0 |
|
| - (Ease of Cleaning) |
1000.0 |
|
| - (Chemical composition of Braille and Base Layers) |
5000.0 |
|
| - (Corrosion resistance from Neutral Salt Spray) |
21000.0 |
|
| - (Accelerated Weathering Test) |
35000.0 |
|
|
| 1352 |
National Test House (WR), Mumbai
| IS 8540 - Glass Cleaner |
Glass Cleaner |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| - (Colour) |
500.0 |
|
| - (Odour) |
500.0 |
|
| - (Toxicity) |
3000.0 |
|
| - (Stability) |
1000.0 |
|
| - (Application and Performance) |
500.0 |
|
| - (Water content) |
1500.0 |
|
| - (Flash Point) |
1000.0 |
|
| - (Non-Volatile Matter Content) |
1000.0 |
|
| - (pH Value) |
1000.0 |
|
| - (Test for Cleaning Efficiency) |
1500.0 |
|
| - (Test for Corrosion or Discolouration) |
1500.0 |
|
|
| 1353 |
National Test House (ER), Kolkata
| IS 13620 (1993) - Fusion Bonded Epoxy Coated Reinforcing Bars - |
Fusion Bonded Epoxy Coated Reinforcing Bars - |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| A-5 (Pull-out test) |
20000.0 |
|
| 7.1 (Coating Thickness) |
1500.0 |
|
| 7.3 (Adhesion of Coating) |
2000.0 |
|
| A-7 (Impact Test - Resistance of Coating) |
1500.0 |
|
|
| 1354 |
National Test House (NR), Ghaziabad
| IS 5354 (1992) - Textiles - Cotton stripping tape for electrical purposes - Specification (first revision) |
Textiles - Cotton stripping tape for electrical purposes - Specification (first revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Cl. 4.2 (Length) |
1000.0 |
|
| Table 1 (Thickness) |
1000.0 |
|
| Table 1 (Width) |
1000.0 |
|
| Table 1 (Ends/dm) |
1000.0 |
|
| Table 1 (Picks/dm) |
1000.0 |
|
| Table 1 (Weave) |
1000.0 |
|
| Firm's requirement (pH) |
1000.0 |
|
| Firm's requirement (pH after immersion in transformer oil) |
3000.0 |
|
|
| 1355 |
National Test House (SR), Chennai
| IS 516 (Part-11) (2020) - Hardened Concrete - Determination of Portland cement Content of Hardened Hydraulic Cement Concrete |
Hardened Concrete - Determination of Portland cement Content of Hardened Hydraulic Cement Concrete |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6 (Portland cement content of a sample of hardened hydraulic cement concrete - IS 516 (Part 11) : 2020) |
5000.0 |
|
| Custom (Cement : Sand ratio by weight (considering the submitted mortar sample contains Sand & OPC only)) |
1000.0 |
|
|
| 1356 |
National Test House (ER), Kolkata
| Custom - Modified Bitumen |
Modified Bitumen |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Softening point) |
1200.0 |
|
| 2 (Penetration) |
1200.0 |
|
|
| 1357 |
National Test House (WR), Mumbai
| ASM Vol 10 (1975) - FAILURE ANALYSIS AND PREVENTION |
FAILURE ANALYSIS AND PREVENTION |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| ASM (Failure investigation of metallic component and suggestions to avoid re occurrence of the failure) |
50000.0 |
|
|
| 1358 |
National Test House (WR), Mumbai
| - - Non Woven Geo Textiles |
Non Woven Geo Textiles |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| - (Mass per unit area as per ASTM D 5261) |
1000.0 |
|
| - (Tensile Strength as per ASTM D 4632) |
4000.0 |
|
| - (Thickness as per IS 1060(P 5)Sec 3) |
1000.0 |
|
|
| 1359 |
National Test House (SR), Chennai
| IS 2629 (1985 (Reaffirmed 2021)) - Recommended Practice for Hot-Dip Galvanizing of Iron and Steel – Specification |
Recommended Practice for Hot-Dip Galvanizing of Iron and Steel – Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6.1 (Freedom From Defect as per IS 2629) |
1250.0 |
|
| 6.3 (Mass of Coating) |
2000.0 |
|
| 6.2 (Uniformity in Thickness) |
1000.0 |
|
| 6.4.1 (Pivoted Hammer Test for Zinc Coated Fabricated Product) |
3000.0 |
|
| 6.4.3 (Bend Test) |
1000.0 |
|
| 6.4.1 (Pivoted Hammer Test) |
1000.0 |
|
| 6.4.2 (Knife Test) |
1000.0 |
|
| TDS-1 (Coating thickness test (as per IS 6012)) |
1500.0 |
|
| 6.2 (Uniformity of zinc coating (as per IS 2633)) |
1000.0 |
|
| TDS-2 (Dimension, mm) |
1000.0 |
|
| TDS-3 (Tensile Strength (As per IS 1608), N/mm²) |
1000.0 |
|
| TDS-4 (Yield Strength (As per IS 1608), N/mm²) |
1000.0 |
|
| TDS-5 (Percentage Elongation (As per IS 1608), %) |
1000.0 |
|
| TDS-6 (Bend Test (As per IS 1599)) |
1500.0 |
|
| 6.3 (Mass of zinc coating (as per IS 6745), g/m²) |
2000.0 |
|
|
| 1360 |
National Test House (ER), Kolkata
| 15041:2001 (RA 2024) - Textiles – Flat woven webbing slings made of man-made fibres for general services |
Textiles – Flat woven webbing slings made of man-made fibres for general services |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 3.28 (Safe Working Load) |
3000.0 |
|
| 3.28 (Safe Working Load) |
6000.0 |
|
| 3.28 (Safe Working Load) |
8000.0 |
|
| 3.28 (Safe Working Load) |
10000.0 |
|
| 5.4 (Proof Load) |
3000.0 |
|
| 5.4 (Proof Load) |
5000.0 |
|
| 5.4 (Proof Load) |
8000.0 |
|
| 5.4 (Proof Load) |
10000.0 |
|
|
| 1361 |
National Test House (NWR), Jaipur
| IS 5986 (2017) - Hot Rolled Steel Flat Products for Structural Forming and Flanging Purposes |
Hot Rolled Steel Flat Products for Structural Forming and Flanging Purposes |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 8 (Tensile Strength) |
2000.0 |
|
| 8 (Yield Stress) |
1000.0 |
|
| 8 (Percentage Elongation) |
1000.0 |
|
| 9.2.2 (Bend Test) |
1500.0 |
|
| 0 (Mass of Zinc Coating as per IS 4759) |
2000.0 |
|
| 8.3 (Tensile Test as per Table 6 & 7) |
3000.0 |
|
| 7 (Chemical Composition as per Table) |
3000.0 |
|
| 10 (Impact Test) |
5000.0 |
|
| 0 (Uniformity of Coating as per Is 2633) |
1000.0 |
|
| 15 (Dimension) |
1000.0 |
|
| 0 (Dimensions & Weight) |
2000.0 |
|
|
| 1362 |
National Test House (NWR), Jaipur
| IS 5986 (2017) - Hot rolled steel sheet, plate and strip for forming and flanging purposes - Specification (Fourth Revision) |
Hot rolled steel sheet, plate and strip for forming and flanging purposes - Specification (Fourth Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
| 1363 |
National Test House (NWR), Jaipur
| 1708 (1986) - Testing of Small Specimen of Timber |
Testing of Small Specimen of Timber |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Part 1 (Moisture Content, in %) |
1000.0 |
|
| Part 2 (Specific Gravity /Density, g/cm3) |
500.0 |
|
| Part 5 (Static Bending Strength (MoR), N/mm2) |
3000.0 |
|
| Part 8 (Compressive Strength Parallel to Grain, N/mm2) |
3000.0 |
|
| Part 9 (Compressive Strength Perpendicular to Grain, N/mm2) |
3000.0 |
|
| Part 12 (Tensile Strength Parallel to Grain, N/mm2) |
2000.0 |
|
| Part 5, Cl 4.2 (iii) (Static Bending Strength (Modulus of Elasticity), N/mm^2 (kg/cm^2)) |
3000.0 |
|
|
| 1364 |
National Test House (ER), Kolkata
| IS 1838 : Part 3 (2011) - Preformed Fillers for Expansion Joints in Concrete Pavements and Structures(non-extruding and resilient type) Part 3 Polymer Based |
Preformed Fillers for Expansion Joints in Concrete Pavements and Structures(non-extruding and resilient type) Part 3 Polymer Based |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5.0 (Dimensions) |
1000.0 |
|
| 6.0 (Resistance to handling) |
1000.0 |
|
| 6.0 (Recovery) |
1000.0 |
|
| 6.0 (Compression) |
1000.0 |
|
| 6.0 (Extrusion) |
1000.0 |
|
| 6.0 (Water Absorption) |
1000.0 |
|
| 6.0 (Density) |
1000.0 |
|
| 6.0 (Weathering) |
5000.0 |
|
|
| 1365 |
National Test House (NR), Ghaziabad
| 02-ABR-02 (2003) - SPECIFICATION FOR AIR BRAKES FOR FREIGHT AND PASSENGER STOCK OF INDIAN RAILWAYS |
SPECIFICATION FOR AIR BRAKES FOR FREIGHT AND PASSENGER STOCK OF INDIAN RAILWAYS |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Firm's Requirement (Root cause analysis for bursting of BP Hose Pipe) |
5000.0 |
|
|
| 1366 |
National Test House (Satellite Centre), Varanasi
| FCO -1985 (1985) - The Fertiliser (Control) Order 1985 (as amended upto Nov 2023) |
The Fertiliser (Control) Order 1985 (as amended upto Nov 2023) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Schedule I Part A (ALL TESTS AS PER FCO-1985 -(PLEASE SEE THE ANNEXURE)-NABL) |
7000.0 |
|
| Schedule I Part A (ALL TESTS AS PER FCO-1985 -(PLEASE SEE THE ANNEXURE) NON NABL) |
7000.0 |
|
| Schedule I Part A (Moisture) |
1000.0 |
|
| Schedule I Part A (Available Phosphorous percent by weight) |
1000.0 |
|
| Schedule I Part A (Water soluble phosphate (as P2O5)) |
1000.0 |
|
| 1 () |
- |
|
| 1 (1) |
- |
|
| Schedule I Part A (Sulphate Sulphur percent by weight) |
1000.0 |
|
| Schedule I Part A (Free Phosphoric Acid percent by weight ) |
1000.0 |
|
| Schedule I Part A (Total Nitrogen (ammoniacal and urea)) |
1000.0 |
|
| Schedule I Part A (Ammoniacal nitrogen) |
1000.0 |
|
| Schedule I Part A (Water Soluble Potassium percent by weight) |
1000.0 |
|
|
| 1367 |
National Test House (WR), Mumbai
| IS 164 : 2023 (2023) - Ready-Mixed Paint for Road Marking — Specification |
Ready-Mixed Paint for Road Marking — Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Table 1 (Drying time a) Surface dry (IS 101 (Part 3/sec 1))) |
600.0 |
|
| Table 1 (Drying time b) Hard dry (IS 101 (Part 3/Sec 1))) |
600.0 |
|
| Table 1 (Consistency) |
600.0 |
|
| Table 1 (Finish, (IS 101 (Part 3/Sec 4))) |
600.0 |
|
| Table 1 (Colour, (IS 101 (Part 4/Sec 2))) |
600.0 |
|
| Table 1 (Wet opacity, percent, (IS 101 (Part 4/Sec 1))) |
600.0 |
|
| Table 1 (Recoating property, Annexure E) |
600.0 |
|
| Table 1 (Resistance to bleeding, Annexure F) |
600.0 |
|
| Table 1 (Mass in kg/10 liter, (IS 101 (Part 1/Sec 7))) |
600.0 |
|
| Table 1 (Keeping properties (12 Months), (IS 101 (Part 6/Sec 2))) |
5000.0 |
|
| Table 1 (Early wash out resistance (for Type 2 only), Annexure G) |
1000.0 |
|
| Table 1 (No pick up time (for type 2 only), Annexure H) |
1000.0 |
|
| Table 1 (Non Volatile matter , (IS 101 (Part 8/sec 2))) |
600.0 |
|
| Table 1 (Volume solid, (IS 101 (Part 8/sec 6))) |
800.0 |
|
| Table 1 (Taber Abrasion resistance, mg weight loss after 500 cycles using CS10 wheel with 500 g on each load (for type 2 only), Annexure J) |
2000.0 |
|
| Table 1 (Scrub resistance, Annexure K) |
2000.0 |
|
| Table 1 (Resistance to accelerated weathering 500 hours (for type 2 only), Annexure L) |
30000.0 |
|
| Table 1 (Flexibility (for type 2 only), (IS 101 (Part 5 /sec 2 ))) |
600.0 |
|
| Table 1 (VOC, percent, (IS 101 (Part 2 /sec 4))) |
2000.0 |
|
| Table 1 (Resistance to wear, Annexure M) |
3000.0 |
|
| 5.4 (Lead Restriction (IS 101 (Part 8/Sec 5), or by Atomic
Absorption Spectrometer (AAS) or by ICP.)) |
1000.0 |
|
|
| 1368 |
National Test House (ER), Kolkata
| IS 17875 (2022) - Stainless Steel Seamless Pipes and Tubes for General Services |
Stainless Steel Seamless Pipes and Tubes for General Services |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 10.1 (Tensile Strength) |
1000.0 |
|
| 10.1 (Yield Strength) |
1000.0 |
|
| 10.1 (Percent Elongation) |
1000.0 |
|
| 23 (Outside Diameter) |
500.0 |
|
| 21 (Workmanship, Finish, and Appearance) |
1000.0 |
|
| 12 (HARDNESS TEST FOR TUBES) |
2000.0 |
|
| 13 (FLARING TEST (FOR TUBES ONLY)) |
1500.0 |
|
| 23 (Wall Thickness) |
500.0 |
|
| 15 (Micro Structure Austenitic Grain Size) |
3000.0 |
|
| 17 (Hydraulic Pressure Test) |
5000.0 |
|
| 18 (Inter-Granular Corrosion Test) |
10000.0 |
|
| 8 (Chemical Composition) |
5000.0 |
|
| 8.1 & 8.2 (Carbon) (Carbon (as C)) |
1000.0 |
|
| 8.1 & 8.2 (Manganese) (Manganese (as Mn)) |
1000.0 |
|
| 8.1 & 8.2 (Silicon) (Silicon (as Si)) |
1000.0 |
|
| 8.1 & 8.2 (Nickel) (Nickel (as Ni)) |
1000.0 |
|
| 8.1 & 8.2 (Chromium) (Chromium (as Cr)) |
1000.0 |
|
| 8.1 & 8.2 (Molybdenum) (Molybdenum (as Mo)) |
1000.0 |
|
| 8.1 & 8.2 (Sulphur) (Sulphur (as S)) |
1000.0 |
|
| 8.1 & 8.2 (Phosphorus) (Phosphorus (as P)) |
1000.0 |
|
| 8.1 & 8.2 (Copper) (Copper (as Cu)) |
500.0 |
|
| 8.1 & 8.2 (Nitrogen) (Nitrogen (as N)) |
500.0 |
|
| 8 (CHEMICAL COMPOSITION,
C,Si,Mn,Ni,Cr, Mo, S,P,N,Cu ,Others) |
5000.0 |
|
|
| 1369 |
National Test House (ER), Kolkata
| IS 17876 (2022) - Stainless Steel Welded Pipes and Tubes for General Services - Specification |
Stainless Steel Welded Pipes and Tubes for General Services - Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Clauses 8.1 and 8.2 (Carbon (as C)) |
1000.0 |
|
| Clauses 8.1 and 8.2 (Silicon (as Si)) |
1000.0 |
|
| Clauses 8.1 and 8.2 (Manganese (as Mn)) |
1000.0 |
|
| Clauses 8.1 and 8.2 (Nickel (as Ni)) |
1000.0 |
|
| Clauses 8.1 and 8.2 (Chromium (as Cr)) |
1000.0 |
|
| Clauses 8.1 and 8.2 (Molybdenum (as Mo)) |
1000.0 |
|
| Clauses 8.1 and 8.2 (Sulphur (as S)) |
1000.0 |
|
| Clauses 8.1 and 8.2 (Phosphorus (as P)) |
1000.0 |
|
| 10.1 (Tensile Requirement - Tensile Strength as per IS 1608 Part 1 or Test Method specified) |
1000.0 |
|
| 10.1 (Tensile Requirement - Yield Strength as per IS 1608 Part 1 or Test Method specified) |
1000.0 |
|
| 10.1 (Tensile Requirement - %Percentage of Elongation (on Gauge Length of 50mm) as per IS 1608 Part 1 or Test Method specified) |
1000.0 |
|
| 12 (Hardness Test - Rockwell Hardness as per IS 1586 Part 1 / Brinell Hardness as per IS 1500 Part 1 or other Test Method Specified) |
2000.0 |
|
| 11 (Transverse Tension Test as per IS 1608 Part 1) |
3000.0 |
|
| 13 (Flange Test as per IS 2330 or relevant Test Method Specified) |
1500.0 |
|
| 14 (Reverse Flattening Test as per IS 17876 or specified Test Method) |
1000.0 |
|
| 16 (Grain Size determined as per IS 4748 or relevant test method specified) |
3500.0 |
|
| 18 (Leak Tightness Test by Hydrostatic Test as IS 17876 or relevant test method specified) |
2500.0 |
|
| 19 (Corrosion Resistance as per IS 10461 Part 1 or IS 10461 Part2 or relevant test method specified) |
10000.0 |
|
| 22 (Workmanship, Finish, and Appearance- Visual Examination as per IS 17876 or relevant Test Method Specified) |
1000.0 |
|
| 23 (Repair by Welding or Grinding - Visual Examination as per IS 17876 or relevant Test Method Specified) |
1000.0 |
|
| 24 (Dimension Measurement as per IS 17876 or relevant test method Specified) |
1000.0 |
|
| 25 (Marking - Visual Examination as per IS 17876) |
1000.0 |
|
| 8 (Chemical Composition - Ladle Analysis as per IS 228 and its relevant parts or any other established instrumental/chemical method) |
5000.0 |
|
|
| 1370 |
National Test House (NR), Ghaziabad
| NTH/NR/XR/ILC/TEXTILE (2024) - ILC FOR TEXTILE |
ILC FOR TEXTILE |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| IS 1964 (Weight (GSM)) |
- |
|
| IS 1954 (Width of Fabric) |
- |
|
| IS 1969 (Part-1) (Breaking Strength, MD) |
- |
|
| IS 1969 (Part-1) (Breaking Strength, CMD) |
- |
|
| IS 1963 (Threads per unit length, Ends) |
- |
|
| IS 1963 (Threads per unit length, Picks) |
- |
|
|
| 1371 |
National Test House (ER), Kolkata
| Custom/Paint-RPPT/2024 (2024) - Custom/Paint-RPPT/2024 |
Custom/Paint-RPPT/2024 |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1.0 (Tensile Strength) |
2000.0 |
|
| 2.0 (Elongation) |
1000.0 |
|
| 3.0 (Hardness(Shore A)) |
1000.0 |
|
| 4.0 (Water Absorption) |
2000.0 |
|
| 5.0 (Adhesion Test on Concrete) |
1200.0 |
|
| 6.0 (Viscosity (Brookfield)) |
1200.0 |
|
| 7.0 (Dry Film Material Softening Point) |
2000.0 |
|
| 8.0 (Specific gravity) |
1500.0 |
|
| 9.0 (Solid Content) |
1200.0 |
|
| 12 (Solid by weight %) |
1200.0 |
|
| 11 (Touch drying time) |
1200.0 |
|
| 13 (Moisture vapour transmission, g/sq.m/24 hrs) |
5000.0 |
|
| 10 (Density, gm/cc) |
1200.0 |
|
| 14 (Accelerated Weathering Test QUV, 500 hours.) |
25000.0 |
|
|
| 1372 |
National Test House (NER), Guwahati
| MORTH : Part 5 (2013) - SPECIFICATIONS FOR ROAD AND BRIDGE WORKS/ASTM |
SPECIFICATIONS FOR ROAD AND BRIDGE WORKS/ASTM |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Density DAC (Density of Dense Asphaltic Concrete.) |
2000.0 |
|
| Density of SDAC (Density of Semi Dense Asphaltic Concrete) |
2000.0 |
|
| Clause 1 Table 1 (Cutting & Preparation of Core sample -Double Stage) |
1000.0 |
|
| 507 (Thickness of Bituminous Concrete Layer (BC), in mm) |
1000.0 |
|
| 507 (Thickness of DBM Layer (BC), in mm) |
1000.0 |
|
| 505 (Thickness of Dense Bituminous Macadam (DBM), in mm) |
1000.0 |
|
| 505 (Combined Density of Dense Bituminous Macadam (DBM) & BC, in g/cc) |
2000.0 |
|
| 507 (Density / Bulk Specific Gravity of BC ( AASHTO T 166 (21)),) |
2000.0 |
|
| 505 (Density / Bulk Specific Gravity of DBM (AASHTO T 166)) |
2000.0 |
|
|
| 1373 |
National Test House (NER), Guwahati
| IS 13871 (2021) - Powder Coating |
Powder Coating |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Clauses 6.6 and 9.1 (Dry film thickness in microns) |
1000.0 |
|
|
| 1374 |
National Test House (NR), Ghaziabad
| IS 1875 (1992) - Carbon steel billets, blooms, slabs and bars for forgings - Specification (Fifth Revision) |
Carbon steel billets, blooms, slabs and bars for forgings - Specification (Fifth Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6 (Carbon) |
1000.0 |
|
| 6 (Silicon) |
1000.0 |
|
| 6 (Manganese) |
1200.0 |
|
| 6 (Phosphorus) |
1000.0 |
|
|
| 1375 |
National Test House (NR), Ghaziabad
| IS 10748 (2004) - Hot - Rolled steel strip for welded tubes and pipes - Specification (Second Revision) |
Hot - Rolled steel strip for welded tubes and pipes - Specification (Second Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 7.1 & 7.2 (Carbon) |
1500.0 |
|
| 7.1 & 7.4 (Sulphur) |
1000.0 |
|
| 7.1 & 7.5 (Phosphorus) |
1000.0 |
|
| 7.1 & 7.3 (Manganese) |
1500.0 |
|
| 7.1 & 7.6 (CE) |
5000.0 |
|
|
| 1376 |
National Test House (Satellite Centre), Varanasi
| ASTM D-5147 & ASTM D-36 (2022) - Modified Bituminous Sheet Materials |
Modified Bituminous Sheet Materials |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5.0 (Thickness) |
1000.0 |
|
| 6 (Tensile Strength (Longitudinal)) |
1000.0 |
|
| 6 (Tensile Strength (Transverse)) |
1000.0 |
|
| 7 (Tear Strength (Longitudinal)) |
1500.0 |
|
| 7 (Tear Strength (Transverse)) |
1500.0 |
|
| 8.0 (Softening Point) |
1000.0 |
|
| 11 (Low-Temperature Flexibility at -2°C) |
2000.0 |
|
| 11.0 (Low - Temperature Flexibility) |
2000.0 |
|
|
| 1377 |
National Test House (ER), Kolkata
| IS 14252 (2015) - Textiles – High density polyethylene (HDPE)/ polypropylene (PP) woven sack for filling sand – Specification (second revision) |
Textiles – High density polyethylene (HDPE)/ polypropylene (PP) woven sack for filling sand – Specification (second revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 4 (Ash Content) |
2000.0 |
|
| 4 (Avg. Breaking Strength of fabric after UV exposure) |
2000.0 |
|
| 4 (Elongation at break of fabric, Widthwise) |
500.0 |
|
| 4 (Elongation at break of fabric, Lengthwise) |
500.0 |
|
| 4 (Average Breaking Strength of bottom seam) |
2000.0 |
|
| 4 (Avg. Breaking Strength of fabric, Widthwise) |
1000.0 |
|
| 4 (Avg. Breaking Strength of fabric, Lengthwise) |
1000.0 |
|
| 4 (Mass of Sack (without tying cord)) |
1000.0 |
|
| 4 (Picks/dm) |
500.0 |
|
| 4 (Ends/dm) |
500.0 |
|
| 4 (Dimensions, Outside Width) |
500.0 |
|
| 4 (Dimensions, Outside Length) |
500.0 |
|
| 4 (Mass of Bale) |
2000.0 |
|
| 3.4.1 (Mouth of Sack, Channel secured with ) |
2000.0 |
|
| 3.4.1 (Mouth of Sack, Channel withturn-in) |
2000.0 |
|
| 3.3 (Tying cord Material Identification) |
2000.0 |
|
| 3.4.1 (Mouth of Sack, Channel width) |
2000.0 |
|
| 3.4.1 (Bottom Seam, Number of Stitchs per dm) |
2000.0 |
|
| 3.4.1 (Bottom Seam, Double fold seam depth) |
2000.0 |
|
| 3.4.1 (Bottom Seam, Outer stitch distance from outer edge) |
2000.0 |
|
| 3.4.1 (Bottom Seam, Two row separation distance) |
2000.0 |
|
| 4 (UV - Resistance Test (192 hrs.)) |
9600.0 |
|
| 4 (GSM of Fabrics) |
1000.0 |
|
|
| 1378 |
National Test House (NR), Ghaziabad
| ICF Drg.No. ICF/STD-6-4-028 Alt a - CUSTOM STANDARDS FOR NWR AJMER |
CUSTOM STANDARDS FOR NWR AJMER |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| CLAUSE-A,Table-1 (Nylon Wire Bottle Holder For Non AC Coaches (Colour Blue)
Please see the Annexure) |
10000.0 |
|
| CLAUSE-A,Table-1 (Eyelet with plain washer Item no.4 IS:410-67 Cu Zn 37(Lab no. 20/24)
Please see the Annexure) |
10000.0 |
|
|
| 1379 |
National Test House (SR), Chennai
| CUS/SR/Chem (2024) - Custom Standard for Metal Samples |
Custom Standard for Metal Samples |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Carbon) |
1000.0 |
|
| 2 (Manganese) |
1000.0 |
|
| 3 (Sulphur) |
1000.0 |
|
| 4 (Phosphorous) |
1000.0 |
|
| 5 (Silicon) |
1000.0 |
|
| 6 (Copper (as Cu)) |
1000.0 |
|
| 7 (Nickel (as Ni)) |
1000.0 |
|
| Custom (Chemical composition - IS 9879:1998.) |
5000.0 |
|
| Custom (Chemical Composition for Metal samples) |
5000.0 |
|
|
| 1380 |
National Test House (SR), Chennai
| CUS/SR/NDT/CUSTOM/001 (2024) - Welding wire |
Welding wire |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1.0 (Size of Wire) |
1000.0 |
|
| 2.0 (Type of Wire) |
2000.0 |
|
|