31 |
NTH/NR/IRCON/Geotextile (2025) - Non Woven Geotextiles |
Non Woven Geotextiles |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
Firm's requirement (Results of Test) |
10000.0 |
|
|
32 |
IS 16532 (2017) - APP Modified Bituminous Waterproofing and DampProofing Membrane with Polyester
Reinforcement - Specification |
APP Modified Bituminous Waterproofing and DampProofing Membrane with Polyester
Reinforcement - Specification |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
5.1 (Dimensions) |
1000.0 |
|
5.2 (Weight (GSM)) |
1000.0 |
|
Table 4 (i) (Thickness of Membrane) |
500.0 |
|
Table 4 (ii) (Cold Flexibility) |
2000.0 |
|
Table 4 (iii) (Softening Point) |
1500.0 |
|
Table 4 (iv) (Tensile Strength, Longitudinal) |
1000.0 |
|
Table 4 (iv) (Tensile Strength, Transverse) |
1000.0 |
|
Table 4 (v) (Elongation, Longitudinal) |
500.0 |
|
Table 4 (v) (Elongation, Tarnsverse) |
500.0 |
|
Table 4 (vi) (Tear Strength, Longitudinal) |
1000.0 |
|
Table 4 (vi) (Tear Strength, Transverse) |
1000.0 |
|
Table 4 (vii) (Heat Resistance) |
1000.0 |
|
Table 4 (viii) (Penetration @25°C, 100g, 5s) |
2000.0 |
|
Table 4 (ix) (Water Absorption) |
1000.0 |
|
Table 4 (x) (Dimension stability, longitudinal/transverse) |
1000.0 |
|
Table 4 (xi) (Pressure Head Test) |
1000.0 |
|
4.1.1 (Type of Reinforcement) |
1000.0 |
|
|
33 |
IS 1180 : Part 1 (2014) - Outdoor Type Oil Immersed Distribution Transformers - Specification Part 1 Mineral Oil Immersed (Fourth Revision) ( 501kVA TO 1000 kVA ) [501kVA TO 1000 kVA] |
Outdoor Type Oil Immersed Distribution Transformers - Specification Part 1 Mineral Oil Immersed (Fourth Revision) ( 501kVA TO 1000 kVA ) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
21.3(b) (Temperature Rise Test) |
35000.0 |
|
21.2(a) (Measurement of Winding Resistance) |
1000.0 |
|
21.2(b) (Measurement of voltage ratio and, check of voltage vector relationship) |
1500.0 |
|
21.5.1.121.5.2.121.5.3.1 (Vacuum Pressure (Type Test)) |
15000.0 |
|
21.5.1.221.5.2.221.5.3.2 (Pressure test (routine)) |
5000.0 |
|
21.4.(d) (Adhesion by Tape Test) |
5000.0 |
|
21.5.1.321.5.2.321.5.3.3 (Oil leakage test) |
7000.0 |
|
21.2(c) (Measurement of impedance voltage (principal tapping), short circuit impedance and load loss (At 50% and 100% load)) |
7000.0 |
|
7.9 & 8.9 (Measurement of Permissible flux density and over fluxing) |
20000.0 |
|
21.4( c) (Measurement of No load current at 112.5 percent voltage) |
2000.0 |
|
21.2(e) (Measurement of insulation resistance) |
1500.0 |
|
21.2(d) (Measurement of no Load and loss and current) |
6000.0 |
|
21.2(f) (lnduced Over Voltage withstand test) |
3000.0 |
|
21.4(a) (Determination of sound levels) |
6000.0 |
|
21.4( e) (BDV of Oil in the transformer) |
10000.0 |
|
21.3(a) (Lightning Impulse Voltage Test) |
50000.0 |
|
21.2(g) (AC High Voltage Withstand Test) |
2500.0 |
|
As per CBIP Manual No. 317 Cl. (Harmonics of No-load Current) |
12000.0 |
|
As per CBIP No. 317 Cl. 3.10 (Zero Sequence Impedance Measurement) |
5000.0 |
|
As per CBIP No. 317 Cl. 3.10 (Magnetic Balance Test) |
5000.0 |
|
N.A. (Unbalance Current) |
5000.0 |
|
|
34 |
IS 1180 : Part 1 (2014) - Outdoor Type Oil Immersed Distribution Transformers - Specification Part 1 Mineral Oil Immersed (Fourth Revision) Three Phase ( 1 kVA to 200KVA ) [1kVA to 200KVA] |
Outdoor Type Oil Immersed Distribution Transformers - Specification Part 1 Mineral Oil Immersed (Fourth Revision) Three Phase ( 1 kVA to 200KVA ) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
21.3(b) (Temperature Rise Test) |
24000.0 |
|
21.2(a) (Measurement of Winding Resistance) |
1000.0 |
|
21.2(b) (Measurement of voltage ratio and, check of voltage vector relationship) |
1500.0 |
|
21.5.1.121.5.2.121.5.3.1 (Vacuum Pressure (Type Test)) |
10000.0 |
|
21.5.1.221.5.2.221.5.3.2 (Pressure test (routine)) |
5000.0 |
|
21.4.(d) (Adhesion by Tape Test) |
5000.0 |
|
21.5.1.321.5.2.321.5.3.3 (Oil leakage test) |
7000.0 |
|
21.2(c) (Measurement of impedance voltage (principal tapping), short circuit impedance and load loss (At 50% and 100% load)) |
5000.0 |
|
7.9 & 8.9 (Measurement of Permissible flux density and over fluxing) |
10000.0 |
|
21.4( c) (Measurement of No load current at 112.5 percent voltage) |
2000.0 |
|
21.2(e) (Measurement of insulation resistance) |
1000.0 |
|
21.2(d) (Measurement of no Load and loss and current) |
5500.0 |
|
21.2(f) (lnduced Over Voltage withstand test) |
2500.0 |
|
21.4(a) (Determination of sound levels) |
5000.0 |
|
21.4( e) (BDV of Oil in the tranformer) |
10000.0 |
|
21.3(a) (Lighting Impulse Voltage Test) |
35000.0 |
|
21.2(g) (AC High Voltage Withstand Test) |
2500.0 |
|
As per CBIP Pub No. 317 Cl. 3.17 (Magnetic Balance Test) |
3000.0 |
|
As per CBIP Manual No. 317 Cl (Harmonics of No-load Current) |
10000.0 |
|
As per CBIP No. 317 Cl. 3.10 (Zero Sequence Impedance Measurement) |
3000.0 |
|
N.A. (Unbalance Current) |
3000.0 |
|
|
35 |
IS 1180 : Part 1 (2014) - Outdoor Type Oil Immersed Distribution Transformers - Specification Part 1 Mineral Oil Immersed (Fourth Revision) Single Phase ( 1kVA to 100kVA ) [1kVA to 100kVA] |
Outdoor Type Oil Immersed Distribution Transformers - Specification Part 1 Mineral Oil Immersed (Fourth Revision) Single Phase ( 1kVA to 100kVA ) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
21.3(b) (Temperature Rise Test) |
15000.0 |
|
21.2(a) (Measurement of Winding Resistance) |
700.0 |
|
21.2(b) (Measurement of voltage ratio and, check of voltage vector relationship) |
700.0 |
|
21.5.1.121.5.2.121.5.3.1 (Vacuum Pressure (Type Test)) |
6000.0 |
|
21.5.1.221.5.2.221.5.3.2 (Pressure test (routine)) |
3500.0 |
|
21.4.(d) (Adhesion by Tape Test) |
5000.0 |
|
21.5.1.321.5.2.321.5.3.3 (Oil leakage test) |
5000.0 |
|
21.2(c) (Measurement of impedance voltage (principal tapping), short circuit impedance and load loss (At 50% and 100% load)) |
3000.0 |
|
7.9 & 8.9 (Measurement of Permissible flux density and over fluxing) |
6500.0 |
|
21.4( c) (Measurement of No load current at 112.5 percent voltage) |
2000.0 |
|
21.2(e) (Measurement of insulation resistance) |
700.0 |
|
21.2(d) (Measurement of no Load and loss and current) |
3000.0 |
|
21.2(f) (lnduced Over Voltage withstand test) |
1200.0 |
|
21.4(a) (Determination of sound levels) |
5000.0 |
|
21.4( e) (BDV of Oil in the tranformer) |
10000.0 |
|
21.3(a) (Lighting Impulse Voltage Test) |
25000.0 |
|
21.2(g) (AC High Voltage Withstand Test) |
1200.0 |
|
As per CBIP Pub No. 317 Cl. 3.17 (Magnetic Balance Test) |
2000.0 |
|
As per CBIP Manual No. 317 Cl (Harmonics of No-load Current) |
6000.0 |
|
As per CBIP No. 317 Cl. 3.10 (Zero Sequence Impedance Measurement) |
2000.0 |
|
N.A. (Unbalance Current) |
2000.0 |
|
|
36 |
IS 1180 : Part 1 (2014) - Outdoor Type Oil Immersed Distribution Transformers - Specification Part 1 Mineral Oil Immersed (Fourth Revision) ( 201kVA TO 500kVA ) [201kVA TO 500kVA] |
Outdoor Type Oil Immersed Distribution Transformers - Specification Part 1 Mineral Oil Immersed (Fourth Revision) ( 201kVA TO 500kVA ) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
21.3(b) (Temperature Rise Test) |
30000.0 |
|
21.2(a) (Measurement of Winding Resistance) |
1000.0 |
|
21.2(b) (Measurement of voltage ratio and, check of voltage vector relationship) |
1500.0 |
|
21.5.1.121.5.2.121.5.3.1 (Vacuum Pressure (Type Test)) |
15000.0 |
|
21.5.1.221.5.2.221.5.3.2 (Pressure test (routine)) |
5000.0 |
|
21.4.(d) (Adhesion by Tape Test) |
5000.0 |
|
21.5.1.321.5.2.321.5.3.3 (Oil leakage test) |
7000.0 |
|
21.2(c) (Measurement of impedance voltage (principal tapping), short circuit impedance and load loss (At 50% and 100% load)) |
6000.0 |
|
7.9 & 8.9 (Measurement of Permissible flux density and over fluxing) |
15000.0 |
|
21.4( c) (Measurement of No load current at 112.5 percent voltage) |
2000.0 |
|
21.2(e) (Measurement of insulation resistance) |
1000.0 |
|
21.2(d) (Measurement of no Load and loss and current) |
5500.0 |
|
21.2(f) (lnduced Over Voltage withstand test) |
2500.0 |
|
21.4(a) (Determination of sound levels) |
6000.0 |
|
21.4( e) (BDV of Oil in the tranformer) |
10000.0 |
|
21.3(a) (Lightning Impulse Voltage Test) |
40000.0 |
|
21.2(g) (AC High Voltage Withstand Test) |
2500.0 |
|
As per CBIP Manual No. 317 Cl (Harmonics of No-load Current) |
12000.0 |
|
As per CBIP No. 317 Cl. 3.10 (Zero Sequence Impedance Measurement) |
4000.0 |
|
As per CBIP No. 317 Cl. 3.10 (Magnetic Balance Test) |
4000.0 |
|
N.A. (Unbalance Current) |
4000.0 |
|
|
37 |
IS:3400 PT-22 1984 - METHODS OF TEST FOR VULCANIZED RUBBER Sulphur content only |
METHODS OF TEST FOR VULCANIZED RUBBER Sulphur content only |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
Cl 4 .A-3 (TOTAL SULPHUR CONTENT % by mass) |
7000.0 |
|
|
38 |
IS 758 (2023) - Medical Textiles - Cotton Absorbent Gauze - Specification |
Medical Textiles - Cotton Absorbent Gauze - Specification |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
As per specification (Results of Test) |
1000.0 |
|
|
39 |
IS 758 (1988) - Specification for cotton gauze, absorbent, non-sterilized (fourth revision) |
Specification for cotton gauze, absorbent, non-sterilized (fourth revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
40 |
IS 17508 (2020) - Disposable Adult Incontinence Diaper - Specification |
Disposable Adult Incontinence Diaper - Specification |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
As per specifictaion (Results of Test) |
1000.0 |
|
|
41 |
NTH/NR/XR/2024/School Uniform/01 (2025) - School Uniform |
School Uniform |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
As per specification (Results of Test) |
1000.0 |
|
|
42 |
IS 17509 (2021) - Disposable Baby Diaper Specification |
Disposable Baby Diaper Specification |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
As per Specification (Results of Test) |
1000.0 |
|
|
43 |
CUSTOM - Water |
Water |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
44 |
398 (Part-4) (1994) - ALUMINIUM CONDUCTORS FOR OVERHEAD TRANSMISSION PURPOSES,
PART 4 ALUMINIUM ALLOY STRANDED CONDUCTORS (ALUMINIUM-MAGNESIUM-SILICON TYPE) |
ALUMINIUM CONDUCTORS FOR OVERHEAD TRANSMISSION PURPOSES,
PART 4 ALUMINIUM ALLOY STRANDED CONDUCTORS (ALUMINIUM-MAGNESIUM-SILICON TYPE) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
3.1.4 (Lay Ratio) |
1000.0 |
|
6 (Freedom From Defects) |
1000.0 |
|
7.1 (Wire Diameter) |
1000.0 |
|
12.2.1 (Breaking Load Test of Strand) |
3000.0 |
|
12.3 (Elongation Test) |
3000.0 |
|
12.4 (Resistance Test) |
2000.0 |
|
8 (Joints in Wires) |
1000.0 |
|
12.2 (Breaking Load Test of Wire) |
3000.0 |
|
|
45 |
NTH/NER/Custom/2022/03 - Chemical General |
Chemical General |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Silica (as SiO2), % by mass) |
1000.0 |
|
|
46 |
IS 1891 : Part 1 (2021) - CONVEYOR AND ELEVATOR TEXTILE BELTING – SPECIFICATION PART 1 GENERAL PURPOSE BELTING (Fifth Revision) |
CONVEYOR AND ELEVATOR TEXTILE BELTING – SPECIFICATION PART 1 GENERAL PURPOSE BELTING (Fifth Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
As per Specification (Results of Test) |
5000.0 |
|
|
47 |
IS 3735 (1996) - Canvas Shoes, Rubber Sole |
Canvas Shoes, Rubber Sole |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
As per Specification (Results of Test) |
5000.0 |
|
|
48 |
IS 13893 (1994) - Polyurethane soles semirigid - specification |
Polyurethane soles semirigid - specification |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
As per specification (Results of Test) |
5000.0 |
|
|
49 |
IS 10702 (1992) - Rubber hawal chappal - Specification (Second Revision) |
Rubber hawal chappal - Specification (Second Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
As per Specification (Results of Test) |
5000.0 |
|
|
50 |
IS 11544 (1986) - Specification for slipper, rubber |
Specification for slipper, rubber |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
As per specification (Results of Test) |
5000.0 |
|
|
51 |
IS 6719 (1972) - Solid Pvc Soles And Heels |
Solid Pvc Soles And Heels |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
As per specification (Results of Test) |
5000.0 |
|
|
52 |
IS 5557 : Part 2 (2018) - All rubber gum boots and ankle boots: Part 2 occupational purposes |
All rubber gum boots and ankle boots: Part 2 occupational purposes |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
As per Specification (Results of Test) |
5000.0 |
|
|
53 |
IS 15298 : Part 2 (2016) - Personal protective equipment: Part 2 safety footwear (Second Revision) |
Personal protective equipment: Part 2 safety footwear (Second Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
As per specification (Results of Test) |
5000.0 |
|
|
54 |
NTH/NR/RPPT/Ceiling Tiles/01 (2024) - Solid Mineral Surface Ceiling Tile |
Solid Mineral Surface Ceiling Tile |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
Firm's Req. (Density) |
1000.0 |
|
Firm's Req. (Tensile Strength) |
1500.0 |
|
Firm's Req. (Elongation@break) |
1500.0 |
|
Firm's Req. (Boiling Water Resistance) |
2000.0 |
|
Firm's Req. (Dry Heat Resistance @40-60°C) |
2000.0 |
|
Firm's Req. (Stain Resistance) |
5000.0 |
|
Firm's Req. (Chemical Resistance) |
5000.0 |
|
Firm's Req. (High Heat Resistance @65°C) |
2000.0 |
|
|
55 |
CUSTOMER SPEC ORGANIC COSMO - CUSTOMER SPEC ORGANIC COSMO |
CUSTOMER SPEC ORGANIC COSMO |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (SLS/SLES) |
2000.0 |
|
1 (SLS/SLES) |
1000.0 |
|
2 (Heavy Metals) |
4000.0 |
|
3 (Sulphate) |
1000.0 |
|
|
56 |
IS 1202-2021 (2021) - Method for Testing Tar and Bituminous Materials-Determination of Specific Gravity |
Method for Testing Tar and Bituminous Materials-Determination of Specific Gravity |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
2.1 (Specific Gravity of Bitumen) |
2000.0 |
|
|
57 |
EN 10084 (2008) - CASE HARDENED STEEL |
CASE HARDENED STEEL |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
Table 3 (Carbon) |
1500.0 |
|
Table 3 (Silicon) |
1500.0 |
|
Table 3 (Manganese) |
1000.0 |
|
Table 3 (Phosphorus) |
2000.0 |
|
Table 3 (Sulphur) |
1000.0 |
|
Table 3 (Chromium) |
1000.0 |
|
Table 3 (Molybdenum) |
1000.0 |
|
Table 3 (Nickel) |
1000.0 |
|
CLAUSE- 7.3.1 (Grain Size) |
3000.0 |
|
Clause 7.3.2.1 (Microscopic Inclusions) |
4000.0 |
|
Cl 1 Table 1 (Brinell Hardness (HBW)) |
2000.0 |
|
|
58 |
Custom-2-NTH-LM - Straining/Intermediate Y arm |
Straining/Intermediate Y arm |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Size) |
200.0 |
|
2 (Thickness) |
200.0 |
|
3 (Weight) |
500.0 |
|
4 (Tensile Strength) |
1500.0 |
|
5 (Yield Strength) |
1500.0 |
|
6 (Percentage Elongation) |
1000.0 |
|
8 (Mass of Zinc coating) |
1000.0 |
|
9 (Uniformity of coating) |
500.0 |
|
10 (Powder Coating) |
1000.0 |
|
7 (Carbon) |
500.0 |
|
7 (Sulphur) |
500.0 |
|
7 (Phosphorus) |
500.0 |
|
7 (Manganese) |
500.0 |
|
7 (Silicon) |
500.0 |
|
7 (Carbon equivalent) |
500.0 |
|
11 (Salt Spray Test for 1440 Hours) |
72000.0 |
|
|
59 |
Custom-5-NTH-LM - Wire Mesh Panel |
Wire Mesh Panel |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Width) |
200.0 |
|
2 (Height) |
200.0 |
|
3 (Bend Test) |
1000.0 |
|
4 (Panel Weight) |
500.0 |
|
5 (Tensile Strength of wire) |
3000.0 |
|
6 (Weld Shear Strength) |
9000.0 |
|
7 (Mass of Zinc Coating) |
1000.0 |
|
8 (Powder Coating Thickness) |
2000.0 |
|
9 (Salt Spray Test for 1000 Hours) |
50000.0 |
|
10 (Diameter of Wire) |
500.0 |
|
11 (Mesh Size (c/c)) |
300.0 |
|
12 (Unit Weight) |
500.0 |
|
13 (Ultimate Tensile Strength of wire) |
1000.0 |
|
14 (Yield Stress of wire) |
1000.0 |
|
15 (Elongation of wire) |
1000.0 |
|
16 (Carbon) |
500.0 |
|
17 (Sulphur) |
500.0 |
|
18 (Phosphorus) |
500.0 |
|
18 (Sulphur + Phosphorus) |
500.0 |
|
9 (Salt Spray Test for 1440 hours) |
60000.0 |
|
|
60 |
Custom-6-NTH-LM - G.I Welded Wire Mesh |
G.I Welded Wire Mesh |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Weld Shear Test of Wire Mesh) |
2000.0 |
|
2 (Tensile Strength of G.I Wire) |
1500.0 |
|
3 (Mass of Zinc Coating of G.I Wire) |
2000.0 |
|
5 (Yield Strength of G.I Wire) |
1500.0 |
|
6 (Dimension) |
4000.0 |
|
|