421 |
IS 1293 (2019) - Plugs and socket - Outlets of rated Voltage up to and including 250 Volts and rated current up to and including 16 amperes - Specification (Fourth Revision) |
Plugs and socket - Outlets of rated Voltage up to and including 250 Volts and rated current up to and including 16 amperes - Specification (Fourth Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
29 (Test for Resistance to Rusting) |
- |
|
30.3 (Impact Test at Low Temperature) |
- |
|
30.3 (Tests at Low Temperature) |
- |
|
30.2 (Static Damp Heat Test) |
- |
|
30.1 (Pressure Test at High Temperature) |
- |
|
30 (Additional tests on pins provided with insulating Sleeves ) |
- |
|
28.2 (Test for Resistance to Tracking) |
100.0 |
|
28.1 (Test for Resistance to Abnormal Heat & Fire) |
- |
|
27 (Creepage distances and clearances and distances through sealing compound) |
500.0 |
|
26 (Test for Screws Current carrying parts & connection ) |
200.0 |
|
25.4 (Compression Test for Plugs.) |
100.0 |
|
25.3 (Ball pressure test for parts of insulating material not necessary to retain current carrying parts ) |
- |
|
25.2 (Ball pressure test at 125 ± 20C for one hour for parts of insulating material necessary to retain current carrying parts ) |
- |
|
25.1 (Test for effect of heating at 100 ±20C for one hour) |
- |
|
25 (Resistance to heat ) |
- |
|
24.19 (Compression test,) |
200.0 |
|
24.17 & 24.18 (Gauge Test) |
- |
|
24.15 (Test for verification of Non-removal of cover plates for fixed Socket out lets with 10 N/20 N force. ) |
- |
|
24.14.2 (Test for verification of Removal of cover plates for fixed Socket outlets. ) |
- |
|
24.14.1 (Test for verification of retention of cover plates for fixed Socket –Out lets.) |
- |
|
24.11 (Test to Barriers of portable socket outlets.) |
- |
|
24.1 (Test to verify the fixation of pins in the body of the Plug.) |
- |
|
24.9 (Test for terminals of portable socket outlets ) |
- |
|
24.8 (Test for shutter of Socket outlets ) |
- |
|
24.7 (Test for Plug pins provided with insulating sleeves.) |
- |
|
24.6 (Test for screwed glands for accessories other than ordinary) |
- |
|
24.5 (Compression test for elastomeric or thermoplastic body. ) |
- |
|
24.4 (Impact test at low Temperature for elastomeric or thermoplastic body. ) |
- |
|
24.3 (Torque test for fixed Socket outlets) |
- |
|
24.2 (Tumbling barrel test for Plugs ) |
- |
|
24.1 (Impact test for fixed Socket outlets ) |
- |
|
24 (Mechanical Strength) |
- |
|
23.3 (Conductor Size ) |
100.0 |
|
23 (Flexible cables and their connection ) |
- |
|
21 ( Normal Operation (For 6 & 16A)) |
300.0 |
|
21 ( Normal Operation (For 16A)) |
4000.0 |
|
21 ( Normal Operation (For 6A)) |
3200.0 |
|
20 (Breaking Capacity ) |
1200.0 |
|
19 (Temperature rise test (For 6 & 16A)) |
500.0 |
|
19 (Temperature rise test (For 16A)) |
2000.0 |
|
19 (Temperature rise test (For 6A)) |
1800.0 |
|
18 (Operation of earthing contacts) |
800.0 |
|
17.3 (Flash test ) |
200.0 |
|
17.2 (Electric Strength ) |
- |
|
17.1 (Insulation Resistance ) |
- |
|
17 (Insulation Resistance and electric strength ) |
- |
|
16.3 ( Resistance to Humidity) |
500.0 |
|
16.1 (Test for Resistance to Ageing ) |
- |
|
16 ( Resistance to Ageing to to Harmful ingress of water and to humidity) |
1000.0 |
|
15 (Inter-locked socket outlets ) |
- |
|
14 (Construction of Plugs & Portable Socket outlets ) |
- |
|
13 (Constructional Requirements) |
100.0 |
|
12.3 (Test for Screw less terminals) |
100.0 |
|
12.2.11 (Test for adequacy of Pillar Terminal) |
- |
|
12.2.9 & 12.2.1`0 (Test for Earthing terminals ) |
- |
|
12.2.8 (Test for fixing of Terminals ) |
- |
|
12.2.7 (Test for adequacy of screw clamping (Conductor Slip Test)) |
- |
|
12.2.6 (Test for reliability of screw clamping (Torque & Pull Test)) |
- |
|
12.2.5 (Test for checking damage to conductor) |
- |
|
12.2.4 (Test for Resistance to corrosion.) |
- |
|
12.2.3 (Test for Mechanical Strength) |
- |
|
12.2.2 (Test for connection without special preparation ) |
- |
|
12.2.1 (Test for Conductor space) |
- |
|
12.2 (Terminals with Screw Clamping for External Copper Conductors) |
- |
|
12.1 (General ) |
- |
|
12 (Terminals) |
- |
|
11 (Provisions for Earthing ) |
100.0 |
|
10 (Protection against Electric Shocks ) |
100.0 |
|
9 (Checking of Dimensions ) |
100.0 |
|
8 (Marking) |
500.0 |
|
7 (Classification) |
100.0 |
|
6 (Rating) |
50.0 |
|
5 (General Notes on Tests) |
50.0 |
|
4 (General Requirement) |
- |
|
3 (Terminology) |
- |
|
24.12 (Test for Suspension of portable Socket outlets. ) |
- |
|
23.1 (Provision for cord Anchorage ) |
- |
|
22.2 (Verification of minimum withdrawal force ) |
100.0 |
|
22.1 (Verification of the maximum withdrawal force ) |
- |
|
22 (Force Necessary to withdraw the Plug ) |
- |
|
16.2 (Protection provided by enclosures ) |
- |
|
|
422 |
IS 1554 : Part 1 (1988) - SPECIFICATION FOR PVC INSULATED ( HEAVY DUTY ) ELECTRIC CABLES |
SPECIFICATION FOR PVC INSULATED ( HEAVY DUTY ) ELECTRIC CABLES |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
3.1 (Conductor) |
100.0 |
|
3.1.1 (CONDUCTOR) |
100.0 |
|
4.1.1 (INSULATION) |
100.0 |
|
4.1.2 (INSULATION) |
100.0 |
|
5.1 (Filler and inner sheath) |
100.0 |
|
6.1 (ARMOURING) |
100.0 |
|
7.1.1 (OUTER SHEATH) |
100.0 |
|
7.1.2 (OUTER SHEATH) |
100.0 |
|
15.1 (b) 2 vii (Resistivity) |
250.0 |
|
15.1(b)1 (Dimensions) |
1500.0 |
|
15.1 (b) 2 i (Tensile strength) |
500.0 |
|
15.1 (b) 2 ii (Elongation at break) |
1000.0 |
|
15.1 (b) 2 iii (Torsion test for round wires) |
500.0 |
|
15.1 (b) 2 iv (Winding test for formed wire) |
1000.0 |
|
15.1 (b) 2 v (Uniformity of Zinc Coating) |
1000.0 |
|
15.1 (b) 2 vi (Mass of Zinc coating) |
1000.0 |
|
15.1(a).4 (Conductor resistance-Red ) |
500.0 |
|
15.1(a).4 (Conductor resistance-Red ) |
500.0 |
|
15.1(a).1 (Annealing test ( for copper )) |
1000.0 |
|
15.1(a).2 (Tensile test ( for aluminium )) |
500.0 |
|
15.1(a).3 (Wrapping test ( for aluminium 1) |
500.0 |
|
15.1 (C) 2 iv (Average thickness of sheath) |
250.0 |
|
15.2 (e) (Average thickness of insulation) |
250.0 |
|
15.1 (C) 2 iv (Minimum thickness of sheath) |
250.0 |
|
15.1 (C) 2 iv (Minimum thickness of insulation) |
250.0 |
|
15.1 (d) 1 (Tensile strength at break-Black) |
250.0 |
|
15.1 (d) 2 (Tensile strength at break-Y) |
250.0 |
|
15.1 (d) 1 (Tensile strength at break-B) |
250.0 |
|
15.1 (d) 1 (Tensile strength at break-B) |
250.0 |
|
15.1(d) 2 (Tensile strength,variation-B) |
250.0 |
|
15.2 (f) (Elongation at break-R) |
250.0 |
|
15.2 (f) (Elongation at break-Y) |
250.0 |
|
15.1(d) 2 (Elongation ,variation-B) |
250.0 |
|
15.1 (d) 1 (Elongation at break-Black) |
250.0 |
|
15.1 (d) 2 (Elongation at break-B) |
250.0 |
|
15.1(d) 2 (Tensile strength,variation-Sheath) |
250.0 |
|
15.1 (C) 2 iv (Minimum thickness of insulation) |
250.0 |
|
15.2 (e) (Minimum thickness of insulation) |
250.0 |
|
15.1 (C) 2 iv (Minimum thickness of insulation) |
250.0 |
|
15.2 (e) (Average thickness of insulation) |
250.0 |
|
15.1 (C) 2 iv (Average thickness of insulation) |
250.0 |
|
15.1(d) 2 (Tensile strength,variation-R) |
250.0 |
|
15.1(d) 2 (Tensile strength,variation-Y) |
250.0 |
|
15.1(d) 2 (Tensile strength,variation-B) |
250.0 |
|
15.1(d) 2 (Tensile strength,variation-Black) |
250.0 |
|
15.1(d) 2 (Elongation ,variation-Sheath) |
250.0 |
|
15.1(d) 2 (Elongation ,variation-R) |
250.0 |
|
15.1(d) 2 (Elongation ,variation-Y) |
250.0 |
|
15.1(d) 2 (Elongation ,variation-B) |
250.0 |
|
15.1(d) 2 (Elongation ,variation-Black) |
250.0 |
|
15.1 (d) 5 (Loss of mass in air oven-Insulation) |
1500.0 |
|
15.1 (d) 5 (Loss of mass in air oven-Insulation) |
1500.0 |
|
15.1 (d) 5 (Loss of mass in air oven-Insulation) |
1500.0 |
|
15.1 (d) 5 (Loss of mass in air oven-Insulation) |
1500.0 |
|
15.1 (d) 5 (Loss of mass in air oven-Sheath) |
1500.0 |
|
18.2 (Marking) |
2000.0 |
|
Cl.15.1 (Type tests) |
26000.0 |
|
15.1 (d) 3 (Shrinkage test-Insulation) |
500.0 |
|
15.1 (d) 3 (Shrinkage test-Insulation) |
500.0 |
|
15.1 (d) 3 (Shrinkage test-Insulation) |
500.0 |
|
14.4.1 (Thickness of Inner sheath and Outer Sheath) |
- |
|
15.1.(d)2 (Tensile Strength-Insulation) |
- |
|
15.1(d)2 (Elongation - Insulation) |
- |
|
15.1 (d) 4 (Hot deformation-Insulation) |
500.0 |
|
15.1 (d) 4 (Hot deformation-Insulation) |
500.0 |
|
15.1 (d) 4 (Hot deformation-Insulation) |
500.0 |
|
15.1 (d) 4 (Hot deformation-Sheath) |
500.0 |
|
15.1 (d) 6 (Heat shock test-Insulation) |
500.0 |
|
15.1 (d) 6 (Heat shock test-Insulation) |
500.0 |
|
15.1 (d) 6 (Heat shock test-Insulation) |
500.0 |
|
15.1 (d) 6 (Heat shock test-Sheath) |
500.0 |
|
15.1 (d) 7 (Thermal stability-Insulation) |
500.0 |
|
15.1 (d) 7 (Thermal stability-Insulation) |
500.0 |
|
15.1 (d) 7 (Thermal stability-Insulation) |
500.0 |
|
15.1 (d) 7 (Thermal stability-Sheath) |
500.0 |
|
15.2 (g) (Volume resistivity at ambient temperature ) |
500.0 |
|
15.2 (g) (Volume resistivity at maximum rated temperature) |
500.0 |
|
15.1 (g) (High Voltage AC) |
250.0 |
|
15.1 (f) (High Voltage AC) |
2000.0 |
|
15.1 (f) (High Voltage DC) |
1000.0 |
|
15.1 (h) (Flammability test-Sheath) |
250.0 |
|
15.4(b) (Cold impact test) |
1000.0 |
|
15.4(a) (Cold bend test) |
1000.0 |
|
17.2 (Cable identification) |
100.0 |
|
17.1 (Manufacturer identification) |
100.0 |
|
17.3 (Cable identification) |
100.0 |
|
10.1 (CORE IDENTIFICATION) |
100.0 |
|
10.2 (CORE IDENTIFICATION) |
100.0 |
|
11.1 (LAYING UP OF CORES) |
100.0 |
|
12.1 (INNER SHEATH) |
100.0 |
|
12.2 (INNER SHEATH) |
250.0 |
|
12.3 (INNER SHEATH) |
100.0 |
|
13.1.4 (Binder) |
500.0 |
|
13.1.3 (ARMOURING) |
100.0 |
|
13.1.1 (ARMOURING) |
100.0 |
|
15.3 (c) (Resistivity) |
1000.0 |
|
15.1.1.c1 (a) (Oxygen index ) |
3500.0 |
|
15.1.1.c1 (d) (Temperature index) |
3500.0 |
|
15.2.1.c2 (b) (Flame retardance test on single cable) |
3500.0 |
|
15.1.1.c2 (c) (Flame retardance test on bunched cable) |
3500.0 |
|
15.1.1.c2 (e) (Smoke density rating) |
3500.0 |
|
15.1.1.c2 (f) (Halogen acid gas evaluation) |
3500.0 |
|
Tests (Tests) |
44000.0 |
|
Tests (Tests) |
26000.0 |
|
Tests (Tests) |
26000.0 |
|
Tests (Tests) |
22000.0 |
|
Tests (Type Tests along with Oxygen index test ,Flame retardance test on single cable,Flame retardance test on buncbed cable,Smoke density,Test for halogen acid gas evolution,Temperature index.) |
120000.0 |
|
|
423 |
IS 1475 : Part 1 (2001) - Self - Contained drinking water coolers - Specification: Part 1 energy consumption and performance (Third Revision) |
Self - Contained drinking water coolers - Specification: Part 1 energy consumption and performance (Third Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
9 (Marking ) |
100.0 |
|
7.7.2 (Insulation Resistance in Megaohm) |
6000.0 |
|
7.7.1 (Insulation Resistance in Megaohm) |
2000.0 |
|
7.6 (Instruments) |
1000.0 |
|
7.5 (Preparation and test conditions) |
300.0 |
|
7.4 (For type tests no of samples) |
400.0 |
|
6.15 (Inspection lid) |
300.0 |
|
6.14 (Panels) |
500.0 |
|
6.13 (Connections) |
500.0 |
|
6.12 (Thermal insulation for cooling unit) |
400.0 |
|
6.11 (Outlet device) |
400.0 |
|
6.1 (Drain) |
300.0 |
|
6.9 (Inlet devices) |
300.0 |
|
6.8 (Storage tank ) |
300.0 |
|
6.7 (Thermostat) |
300.0 |
|
6.6 (Refrigerant flow) |
300.0 |
|
6.5 (Refrigerant) |
400.0 |
|
6.4 (Condensing unit) |
200.0 |
|
6.2 (Storage tank of cooling unit) |
300.0 |
|
6.1 (Chassis) |
200.0 |
|
5.6.2 (Storage Capacity in litres) |
300.0 |
|
5.5 (Published Ratings) |
500.0 |
|
5.1 (Rating) |
200.0 |
|
4 (Classifications) |
200.0 |
|
3 (Terminology) |
200.0 |
|
2 (References) |
200.0 |
|
1 (Scope) |
200.0 |
|
6.16 (Cable) |
- |
|
7.7.4 (Temperature of outlet water) |
600.0 |
|
7.7.3 (Temperature of outlet water) |
12000.0 |
|
7.7.2 (High Voltage 1 KV rms) |
1000.0 |
|
|
424 |
IS 2645 (2003) - Integral waterproofing compounds for cement mortar and concrete - Specification (Second Revision) |
Integral waterproofing compounds for cement mortar and concrete - Specification (Second Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
3.3.b (Compressive Strength-7days) |
2000.0 |
|
3.3.a (Compressive Strength-3 days) |
2000.0 |
|
3.2.b (Setting Time (Final Setting Time)) |
500.0 |
|
3.2.a (Setting Time (Initial Setting Time)) |
500.0 |
|
3.1 (Permeability to Water) |
3000.0 |
|
3.4 (Chloride Content, %) |
1000.0 |
|
|
425 |
IS 2180 (1988) - Specification for heavy duty burnt clay building bricks (Third Revision) |
Specification for heavy duty burnt clay building bricks (Third Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
4 (General quality) |
500.0 |
|
5 (Dimensions & Tolerances) |
500.0 |
|
6.1 (Compressive Strength) |
2000.0 |
|
6.2 (Water Absorption) |
1000.0 |
|
6.3 (Efforescence) |
1000.0 |
|
|
426 |
IS 3812 (Part 1) (2013) - Pulverized fuel ash - Specification: Part 1 For use as pozzolana in cement, cement mortar and concrete |
Pulverized fuel ash - Specification: Part 1 For use as pozzolana in cement, cement mortar and concrete |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
7.1 (Soundness by autoclave test — Expansion of specimen ) |
1500.0 |
|
7.1 (Compressive strength at 28 days ) |
3000.0 |
|
7.1 ( Lime reactivity — Average compressive strength ) |
3000.0 |
|
7.1 (Particles retained on 45 micron IS sieve (wet sieving) ) |
1000.0 |
|
7.1 (Fineness — Specific surface by Blaine’s permeability method) |
1000.0 |
|
5.1 ,6.1 (Loss on ignition) |
500.0 |
|
5.1 ,6.1 (Total Chlorides) |
500.0 |
|
5.1 ,6.1 (Available alkali as equivalent sodium oxide (Na2O)) |
500.0 |
|
5.1 ,6.1 (Total Sulphur as sulphur trioxide(SO3)) |
500.0 |
|
5.1 ,6.1 (Magnesium oxide(MgO)) |
500.0 |
|
5.1 ,6.1 (Reactive Silica) |
500.0 |
|
5.1 ,6.1 (Silicon dioxide(SiO2)) |
500.0 |
|
5.1 ,6.1 (Silicon dioxide(SiO2) plus aluminium oxide (Al2O3) plus iron oxide (Fe2O3)) |
500.0 |
|
|
427 |
IS 1757 Part 1 (2020) - Metallic Materials — Charpy Pendulum Impact Test Part 1 Test Method ( Fourth Revision ) |
Metallic Materials — Charpy Pendulum Impact Test Part 1 Test Method ( Fourth Revision ) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
9 (Impact Test with sample preparation) |
5000.0 |
|
9 (Impact Test without sample preparation) |
4000.0 |
|
|
428 |
IS 1501 : Part 1 (2020) - Metallic Materials — Vickers Hardness Test Part 1 Test Method ( Fifth Revision ) |
Metallic Materials — Vickers Hardness Test Part 1 Test Method ( Fifth Revision ) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Hardness) |
2000.0 |
|
|
429 |
IS 1586 : Part 1 (2018) - Metallic materials - Rockwell hardness test: Part 1 test method (Fifth Revision) |
Metallic materials - Rockwell hardness test: Part 1 test method (Fifth Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Hardness) |
2000.0 |
|
|
430 |
IS 1500 : Part 1 (2019) - Metallic materials - Brinell hardness test: Part 1 test method (Fifth Revision) |
Metallic materials - Brinell hardness test: Part 1 test method (Fifth Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Hardness) |
2000.0 |
|
|
431 |
IS 513 : Part 2 (2016) - Cold reduced carbon steel sheet and strip: Part 2 high tensile and multi - Phase steel (Sixth Revision) |
Cold reduced carbon steel sheet and strip: Part 2 high tensile and multi - Phase steel (Sixth Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
7.1 (Yield stress) |
1000.0 |
|
7.2 (Bend Test) |
1000.0 |
|
10 (Thickness) |
1000.0 |
|
|
432 |
IS 2062 (2011) - Hot rolled medium and high tensile structural steel - Specification (Seventh Revision) |
Hot rolled medium and high tensile structural steel - Specification (Seventh Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
10 (Tensile Strength - IS 1608 (Part 1): 2022) |
1000.0 |
|
10 (Yield Stress - - IS 1608 (Part 1): 2022.) |
1000.0 |
|
10 (% Elongation - IS 1608 (Part 1): 2022.) |
1000.0 |
|
11 (Bend Test - IS 1599: 2019.) |
1500.0 |
|
12 (Impact Test (For Specified Quality Grade)) |
5000.0 |
|
8.2 (Carbon) |
500.0 |
|
8.2 (Sulphur) |
500.0 |
|
8.2 (Phosphorus) |
500.0 |
|
8.2 (Manganese) |
500.0 |
|
8.2 (Silicon) |
500.0 |
|
8.2 (Carbon Equivalent, %) |
500.0 |
|
0 (Percent elongation test, %) |
3000.0 |
|
0 (Yield strength Test, N/mm2) |
3000.0 |
|
0 (Tensile strength Test, N/mm2) |
5000.0 |
|
0 (Thickness) |
500.0 |
|
0 (Coating Thickness) |
2000.0 |
|
0 (Mass of Zinc Coating) |
2000.0 |
|
0 (Uniformity of Coating) |
1000.0 |
|
0 (Salt Spray Test) |
60000.0 |
|
0 (Overall Weight) |
1500.0 |
|
0 (Dimensions) |
1000.0 |
|
12 (Impact Test) |
5000.0 |
|
7 (Freedom from Defects) |
1000.0 |
|
0 (Adhesion Test) |
1000.0 |
|
|
433 |
IS 1786 (2008) - High strength deformed steel bars and wires for concretere inforcement - Specification (Fourth Revision) |
High strength deformed steel bars and wires for concretere inforcement - Specification (Fourth Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
5.7 (5) (Percentage increase in Bond Stress of Deformed Bar against corresponding Plain Bar at 0.25 mm slip (For size up to 12 mm), % - IS 2770(Part 1)) |
1250.0 |
|
4.2 (17) (Chemical Composition without micro alloying elements, % by mass.) |
2000.0 |
|
9.4 (1) (Rebend test (32 to 40mm)- IS 1786: 2008) |
1500.0 |
|
9.3 (Bend test - IS 1599: 2023.) |
1000.0 |
|
7.2 (Mass per metre run, kg/m - IS 1786: 2008) |
1000.0 |
|
9.2 (1) (TS/ YS Ratio - (IS 1786: 2008/ IS 1608 (Part 1): 2022).) |
- |
|
9.2 (2) (Elongation Percent on gauge length of 5.65 Square Root of Crosss- Sectional Area, % - IS 1608 (Part 1): 2022.) |
1000.0 |
|
9.2 (6) (Tensile Strength (32 to 40 mm), N/mm² - IS 1608 (Part 1): 2022.) |
1500.0 |
|
4.2 (2) (Carbon, % by mass (As per ASTM E 415-21/ IS 8811: 1998).) |
500.0 |
|
4.2 (3) (Sulphur, % by mass (As per ASTM E 415-21/ IS 8811: 1998).) |
500.0 |
|
4.2 (4) (Phosphorus, % by mass (As per ASTM E 415-21/ IS 8811: 1998).) |
500.0 |
|
4.2 (5) (Sulphur+ Phosphorus, % by mass.) |
500.0 |
|
9.2 (4) (Tensile Strength (up to 12 mm), N/mm² - IS 1608 (Part 1): 2022.) |
- |
|
9.2 (5) (Tensile Strength (16 to 28 mm), N/mm² - IS 1608 (Part 1): 2022.) |
1000.0 |
|
9.2 (6) (Tensile Strength (32 to 40 mm), N/mm² - IS 1608 (Part 1): 2022.) |
1500.0 |
|
9.4 (Rebend test (0 - 28 mm) - IS 1786: 2008) |
1000.0 |
|
9.3 (Bend test - IS 1599: 2023.) |
1000.0 |
|
9.2 (2) (Elongation Percent on gauge length of 5.65 Square Root of Crosss- Sectional Area, % - IS 1608 (Part 1): 2022.) |
1000.0 |
|
9.2 (Yield Stress/ 0.2 % Proof Stress. N/mm² -- IS 1608 (Part 1): 2022.) |
1000.0 |
|
9.2 (3) (Total Elongation at Maximum Force on gauge length of 5.65 Square Root of Crosss- Sectional Area, % - IS 1608 (Part 1): 2022.) |
- |
|
9.1.1 (Tensile Strength) |
3000.0 |
|
9.1.2 (Yield/0.2% Proof Stress) |
3000.0 |
|
9.1.3 (Percentage Elongation) |
3000.0 |
|
4.2 (1) (Carbon Equivalent (CE), , % by mass.) |
2000.0 |
|
0 (Salt spray test 48hrs as per ASTM B117) |
2000.0 |
|
0 (Test for thickness of coating) |
3000.0 |
|
5.7 (Pull out test upto 32mm) |
15000.0 |
|
|
434 |
IS 513 : Part 1 (2016) - Cold reduced carbon steel sheet and strip: Part 1 cold forming and drawing purpose (Sixth Revision) |
Cold reduced carbon steel sheet and strip: Part 1 cold forming and drawing purpose (Sixth Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
11 (Thickness) |
1000.0 |
|
8.1 (Yield stress) |
1000.0 |
|
8.3 (Hardness Test) |
2000.0 |
|
8.1 (Tensile strength) |
1000.0 |
|
8.1 (% Elongation) |
1000.0 |
|
8.4 (Bend Test) |
1000.0 |
|
|
435 |
IS 277 (2018) - Galvanized steel strips and sheets (Plain And Corrugated) - Specification (Seventh Revision) |
Galvanized steel strips and sheets (Plain And Corrugated) - Specification (Seventh Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
8.1 (Tensile strength, MPa) |
1000.0 |
|
8.1 (Yield Strength, MPa) |
1000.0 |
|
8.1 (Percentage Elongation, %) |
1000.0 |
|
8.2 (Bend Test) |
1000.0 |
|
14 (Total coated thickness, mm) |
1000.0 |
|
8.1 (Mass of Zn coating) |
2000.0 |
|
5.1 (Phosphorus) |
500.0 |
|
5.1 (Sulphur) |
500.0 |
|
5.1 (Manganese) |
500.0 |
|
5.1 (Carbon) |
500.0 |
|
0 (Thickness of Paint coating at side 1) |
1000.0 |
|
0 (Thickness of Paint coating at side 2) |
1000.0 |
|
0 (Base metal thickness, mm) |
1000.0 |
|
15 (Dimensions of Corrugated sheet) |
1000.0 |
|
12 (Freedom from defects) |
1000.0 |
|
0 (Pencil Hardness Test as per IS 14246) |
1000.0 |
|
|
436 |
IBR 1950 (2023) - Qualified Boiler Welder's Certificate |
Qualified Boiler Welder's Certificate |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
IBR-1950, Chapter -XIII (Welder Test - Plate) |
3000.0 |
|
NTH Additional Charges for Testing (Scientist Charges) |
5000.0 |
|
IBR-1950, Chapter -XIII (IBR Welder Test - Tube/Pipe (MMAW)- Horizontally Fixed) |
3500.0 |
|
IBR-1950, Chapter -XIII (IBR Welder Test - Tube/Pipe (MMAW)- Vertically Fixed) |
3500.0 |
|
IBR-1950, Chapter -XIII (IBR Welder Test - Tube/Pipe (GTAW+ MMAW)- Horizontally Fixed) |
4500.0 |
|
IBR-1950, Chapter -XIII (IBR Welder Test - Tube/Pipe (GTAW+ MMAW)- Vertically Fixed) |
4500.0 |
|
0 (Scientist charge 2) |
5000.0 |
|
|
437 |
ASME ASME (2021) - Performance test ( Plate & electrodes not supplied by NTH) |
Performance test ( Plate & electrodes not supplied by NTH) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
ASME (Welding procedure qualification) |
7000.0 |
|
QB 484 (Brazing Performance Test) |
5000.0 |
|
|
438 |
ASME ASME Section IX (2021) - Preparation of welding procedure specification (WPS) as per ASME Section IX |
Preparation of welding procedure specification (WPS) as per ASME Section IX |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
ASME Section IX (Welding procedure Specification) |
10000.0 |
|
|
439 |
ASME Section IX (2019) - 2019 Boiler and Pressure Vessel Code |
2019 Boiler and Pressure Vessel Code |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
QW 191 (Radiography Test -Pipe) |
3200.0 |
|
QW 191 (Radiography Test -Plate) |
1200.0 |
|
|
440 |
IS 6012 (1992) - Measurement of coating thickness by eddy current method (First Revision) |
Measurement of coating thickness by eddy current method (First Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
IS 6012 (Coating thickness) |
2000.0 |
|
|
441 |
IS 2595 (2008) - Industrial radiographic testing - Code of practice (Second Revision) |
Industrial radiographic testing - Code of practice (Second Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
IS 2595 (Radiography) |
2000.0 |
|
|
442 |
IS 5523 (1983) - Methods of testing anodic coatings on aluminium and its alloys (First Revision) |
Methods of testing anodic coatings on aluminium and its alloys (First Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
IS 5523 (Coating thickness) |
2000.0 |
|
|
443 |
13683 (2006) - Ring Spun Grey Cotton Yarn |
Ring Spun Grey Cotton Yarn |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
444 |
IS 10733 (1983) - Tanker Hose of Rubber |
Tanker Hose of Rubber |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
445 |
IS 8329 (2000) - Centrifugally cast (Spun) ductile iron pressure pipes for water, gas and sewage - Specification (Third Revision) |
Centrifugally cast (Spun) ductile iron pressure pipes for water, gas and sewage - Specification (Third Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
15.1.1 (External diameter) |
1000.0 |
|
10.1.1 (Tensile Strength) |
2000.0 |
|
10.1.1 (Percent Elongation) |
1500.0 |
|
10.2 (Brinell Hardness) |
2000.0 |
|
16.2 (Bituminous Coating Test) |
1000.0 |
|
15.3 (Ovality of pipe) |
1000.0 |
|
16.3 (Thickness of Cement mortar lining of pipe) |
1000.0 |
|
13.3 (Wall Thickness of pipe) |
1000.0 |
|
13.2 (Bore Clearance of mortar lining in ductile iron pipe) |
1000.0 |
|
|
446 |
CBIP 317 (2013) - Central Board of Irrigation & Power-Manual No-317-
Single Phase Transformer |
Central Board of Irrigation & Power-Manual No-317-
Single Phase Transformer |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
Sec BB (3) (Magnetic Balance Test) |
2000.0 |
|
Sec BB (3) (Measurement of unbalanced current) |
2000.0 |
|
Sec BB (3) (Polarization lndex) |
5000.0 |
|
Sec BB (3) (Voltage) |
3000.0 |
|
Sec BB (3) (Unbalanced Current) |
3000.0 |
|
17.3.2 (Permanent Deflection) |
10000.0 |
|
17.3.1 (Permanent Deflection) |
8000.0 |
|
|
447 |
IS 335 (1993) - NEW INSULATING OILS- SPECIFICATION |
NEW INSULATING OILS- SPECIFICATION |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
4.5.2.6 (Measurernent of Break Down Voltage of trransformer Oil) |
10000.0 |
|
|
448 |
IS 15652 (2006) - Insulating mats for electrical purposes - Specification |
Insulating mats for electrical purposes - Specification |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
8.2.1 (Insulation Resistance with Water) |
4000.0 |
|
8.2.2 (Leekage Current Test) |
2500.0 |
|
8.2.3 (AC Dielectric Strength) |
7000.0 |
|
8.2.4 (AC Proof Voltage) |
3000.0 |
|
6.3 (Thickness) |
500.0 |
|
8.4.2 (Low Temperature Resistance & High Voltage test) |
4000.0 |
|
8.6 (Extreme low temperature test) |
6000.0 |
|
8.1 (Tensile Strength,bnd Elongation at Break) |
1500.0 |
|
8.3 (Tensile Strength and Elongation at break
After Ageing) |
4000.0 |
|
8.5 (After Acid/Alkalis and Oil Resistance) |
4500.0 |
|
8.4.1 (Flame Retardance) |
2000.0 |
|
6.2 (Dimensions) |
1000.0 |
|
|
449 |
IS 15769 (2008) - Flux cored (Tubular) electrodes for gas shielded and self - Shielded metal welding of carbon or carbon - Manganese steel |
Flux cored (Tubular) electrodes for gas shielded and self - Shielded metal welding of carbon or carbon - Manganese steel |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
5.2 (Radiographic Soundness Test) |
1000.0 |
|
5.4 (Impact Test) |
5000.0 |
|
5.7 (Diffusible Hydrogen Test as per Method given in IS 11802) |
5000.0 |
|
Clause 9.1.1 (Weld Assembly Preparation) |
5000.0 |
|
|
450 |
IS 2026 : Part 1 (2011) - Power Transformers: Part 1 General (Second Revision) |
Power Transformers: Part 1 General (Second Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
10.1.2(a) (Temperatur Rise) |
20000.0 |
|
10.1.1(a) (Measurement of windlng Resistance) |
1600.0 |
|
10.1.1(b) (Voltage ratio & Phase Displacement) |
3200.0 |
|
10.1.1 (C) (% impedance and load loss) |
12800.0 |
|
10.1.1(d) (No Load loss and current) |
9600.0 |
|
10.1.1(e) (Separate source AC voltage withstand test) |
4000.0 |
|
10.1.1(e) (Induced Overvoltage) |
6400.0 |
|
10.1.2(b) (Lightning lmpulse Voltage test, Chopped
impulse voltage test, Multi chopped irnpulse voltage test) |
500000.0 |
|
10.1.3(d) (Measurement of Zero phase sequence impedance for 3
Phase transformer) |
3000.0 |
|
10.1.3(g) (% Harmonics) |
10000.0 |
|
10.1.3(j) (Measurement of Insulation Resistance) |
2400.0 |
|
10.1.3 (f) (Noise Level) |
10000.0 |
|
7 (Rating Plate Details) |
- |
|
17.3.1 (a) of CBIP Pub. No. 317 (Pressure Test Routine (Deflection)) |
8000.0 |
|
17.3.2 (a) of CBIP Pub. No. 317 (Vacuum Test - Type (Deflection)) |
10000.0 |
|
17.3.2 (b) of CBIP Pub. No. 317 (Oil Leakage Test (Pressure Test - Type)) |
10000.0 |
|
As per CBIP No. 317 Cl. 3.10 (Magnetic Balance Test) |
3000.0 |
|
As per IS : 335 (Breakdown Voltage Test) |
10000.0 |
|
CBIP Publication no. 317 (Measurement of Unbalance Current) |
5000.0 |
|
|