| 361 |
IS 1285 (2023) - Wrought Aluminium and Aluminium Alloys — Extruded Round Tube and Hollow Sections for General Engineering Purposes |
Wrought Aluminium and Aluminium Alloys — Extruded Round Tube and Hollow Sections for General Engineering Purposes |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 9 (Chemical Analysis (as per IS 733)) |
5000.0 |
|
| 10 (Tensile Strength (as per IS 733)) |
1000.0 |
|
| 10 (0.2 % Proof Stress (as per IS 733)) |
1000.0 |
|
| 10 (% Elongation (as per IS 733)) |
1000.0 |
|
| 8 (Dimension) |
1000.0 |
|
| 4 (Mass per meter) |
1000.0 |
|
| 6 (Freedom from Defect) |
1000.0 |
|
| 8 (Copper, % by mass) |
600.0 |
|
| 8 (Magnesium, % by mass) |
600.0 |
|
| 8 (Silicon, % by mass) |
600.0 |
|
| 8 (Iron, % by mass) |
600.0 |
|
| 8 (Manganese, % by mass) |
600.0 |
|
| 8 (Zinc, % by mass) |
600.0 |
|
| 8 (Titanium, % by mass) |
600.0 |
|
| 8 (Others, % by mass) |
600.0 |
|
| 8 (Chromium, % by mass) |
600.0 |
|
| 8 (Aluminium, % by mass) |
600.0 |
|
| 4 (Dry Film Thickness - Powder Coating as per IS 13871 by Test Method 5 of IS 101 Part-3 Sec.2 1989 or any other test method specified by the customer) |
1500.0 |
|
|
| 362 |
IS 2086 (1993) - Carriers and bases in rewirable type electric fuses for voltages up to 650 v - Specification (Third Revision) |
Carriers and bases in rewirable type electric fuses for voltages up to 650 v - Specification (Third Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
| 363 |
Custom - Berger QUV test - QUV test of Paint and Coating |
QUV test of Paint and Coating |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| A-2 (Salt spry for 96 hrs) |
5000.0 |
|
|
| 364 |
IS 2086 (1993) - Carriers and Bases in Electrical Fuses for voltages up to 650 V - Specification |
Carriers and Bases in Electrical Fuses for voltages up to 650 V - Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 9 (All possible tests as per customer requirement) |
20000.0 |
|
|
| 365 |
IS 9968 : Part 1 (1984) - Elastomer Insulated Cables |
Elastomer Insulated Cables |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 10.2 (Conductor Resistance) |
2000.0 |
|
| 21.1 (Insulation resistance) |
1000.0 |
|
| 22.1 (High voltage (water immersion) test) |
1000.0 |
|
| 22.1 (Flammability test) |
1000.0 |
|
|
| 366 |
IS 3384 (1986) - bitumen primer for use in waterproofing and damp-proofing |
bitumen primer for use in waterproofing and damp-proofing |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 3.1(v)c (Test on residue from distillation upto 360 dg , c)matter soluble in carbon disulphide or ccl4 or tce) |
1200.0 |
|
| 3.1(v)b (Test on residue from distillation upto 360 dg , b)penetration 25 dg 100g 5 sec) |
1200.0 |
|
| 3.1(v) a (Test on residue from distillation upto 360 dg , a)ductility) |
1200.0 |
|
| 3.1(iv) (water Content ) |
1200.0 |
|
| 3.1(iii) (Flash point pensky martens closed type) |
1200.0 |
|
| ADDITIONAL pARAMETER (Specific gravity) |
1200.0 |
|
|
| 367 |
IS 7193:2013 - Glass Fibre Base Bitumen Felts |
Glass Fibre Base Bitumen Felts |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 8 Table 3(Sl.no. i) (Breaking Load(warp direction) as per IS 13826(Part 1)) |
2000.0 |
|
| 8 Table 3(Sl.no. i) (Breaking Load(weft direction) as per IS 13826(Part 1)) |
2000.0 |
|
| 8 Table 3(Sl.no. ii) (Pliability at 23 ±1°C as per IS 13826(Part 2)) |
2000.0 |
|
| 8 Table 3(Sl.no. iii) (Storage Sticking as per IS 13826(Part 3)) |
2000.0 |
|
| 8 Table 3(Sl.no. iv) (Pressure Head test(conditioned at 5°C) as per IS 13826(Part 4)) |
2000.0 |
|
| 8 Table 3(Sl.no. iv) (Pressure Head test(conditioned at 65°C) as per IS 13826(Part 4)) |
2000.0 |
|
| 8 Table 3(Sl.no. v) (Heat resistance at 68±2°C as per IS 13826(Part 5)) |
2000.0 |
|
| 8 Table 3(Sl.no. vi) (Water absorption percent as per IS 13826(Part 6)) |
2000.0 |
|
| 7.1 (Dimensions(Length and Width)) |
1000.0 |
|
| 7.2 (Weight) |
1000.0 |
|
|
| 368 |
IS 1254 (2007) - Corrugated aluminium sheet (Fourth Revision) |
Corrugated aluminium sheet (Fourth Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6 (Aluminium) |
500.0 |
|
| 7 (Dimension) |
1000.0 |
|
|
| 369 |
IS 737 (2008) - Wrought aluminium and aluminium alloy sheet and strip for general engineering purposes - Specification (Fourth Revision) |
Wrought aluminium and aluminium alloy sheet and strip for general engineering purposes - Specification (Fourth Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6 (Chemical Analysis (Please see Annexure)- NABL) |
6000.0 |
|
| 7.2 (Bend Test) |
1000.0 |
|
| 7.1 (% Elongation at 50 mm gauge length) |
500.0 |
|
| 7.1 (0.2% Proof Stress) |
1000.0 |
|
| 7.1 (Tensile Strength) |
1000.0 |
|
| 9 (Dimensions) |
1000.0 |
|
| 6 (Chemical Analysis (Please see Annexure)- NABL) |
6000.0 |
|
| 6 (Titanium) |
1000.0 |
|
| 6 (Silicon) |
1000.0 |
|
| 6 (Manganese) |
1000.0 |
|
| 6 (Chromium) |
1000.0 |
|
| 6 (Magnesium) |
1000.0 |
|
| 6 (Iron) |
1000.0 |
|
| 6 (Copper) |
1000.0 |
|
| 6 (Zinc) |
1000.0 |
|
| 6 (Aluminium) |
1000.0 |
|
| 6 (Chemical composition, Cu+Si+Fe for designation 19990.) |
1000.0 |
|
| 6 (Chemical composition, Cu+Si+Fe+Mn+Zn for Designation 19800) |
1000.0 |
|
| 6,Table1 (Chemical Composition (Please see Annexure) - NON NABL) |
2500.0 |
|
| 6 (Chemical composition, Cr+Mn for Designation 55000) |
2500.0 |
|
|
| 370 |
IS 2553 : PART 1 (1990) - SAFETY GLASS PART 1 ARCHITECTURAL, BUILDING AND GENERAL USES |
SAFETY GLASS PART 1 ARCHITECTURAL, BUILDING AND GENERAL USES |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
| 371 |
IS 2553(1):2018 & IS 17004:2018 (2018) - SAFETY GLASS — SPECIFICATION
PART 1 ARCHITECTURAL, BUILDING AND GENERAL USES
& TESTING METHODS FOR PROCESSED GLASS |
SAFETY GLASS — SPECIFICATION
PART 1 ARCHITECTURAL, BUILDING AND GENERAL USES
& TESTING METHODS FOR PROCESSED GLASS |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
| 372 |
Fibre Glass Insulation - Fibre Glass Insulation |
Fibre Glass Insulation |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| - (Thickness(mm.)) |
1000.0 |
|
|
| 373 |
Nitrile Rubber - Nitrile Rubber |
Nitrile Rubber |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Firm's requirement (Thickness) |
1000.0 |
|
|
| 374 |
IS 14589 (1999) - ZINC PRIMING PAINT, EPOXY BASED, (TWO-PACK) -SPECIFICATION |
ZINC PRIMING PAINT, EPOXY BASED, (TWO-PACK) -SPECIFICATION |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| ZINC PRIMING PAINT, EPOXY BASED, TWO-PACK - SPECIFICATION (Please refer annexure for tests result) |
23000.0 |
|
|
| 375 |
IS 14209 (2016) - Epoxy Enamel, Two Component, Glossy — Specification |
Epoxy Enamel, Two Component, Glossy — Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Epoxy Enamel, Two Component, Glossy — Specification (Please refer annexure for tests result) |
30000.0 |
|
|
| 376 |
IS 13213 (2018) - Polyurethane Full Gloss Enamel (Two Pack) — Specification |
Polyurethane Full Gloss Enamel (Two Pack) — Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Polyurethane Full Gloss Enamel (Two Pack) — Specification (Please refer annexure for tests result) |
46000.0 |
|
|
| 377 |
IS 13238 (2021) - Epoxy Based Zinc Phosphate Primer (Two Pack ) — Specification |
Epoxy Based Zinc Phosphate Primer (Two Pack ) — Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Epoxy Based Zinc Phosphate Primer (Two Pack) — Specification (Please refer annexure for tests result) |
23000.0 |
|
|
| 378 |
IS 13183 (1991) - ALUMINIUM PAINT, HEAT RESISTANT SPECIFICATION |
ALUMINIUM PAINT, HEAT RESISTANT SPECIFICATION |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| ALUMINIUM PAINT, HEAT RESISTANT — SPECIFICATION (Please refer annexure for tests result) |
8000.0 |
|
|
| 379 |
TEC/GR/FA/CDS-008/AUG-19 - Permanently lubricated HDPE Telecom Duct |
Permanently lubricated HDPE Telecom Duct |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| - (Tensile Strength(N/sq.mm.) as per ASTM D 638) |
2000.0 |
|
| - (Elongation(%) as per ASTM D 638) |
2000.0 |
|
| - (Longitudinal reversion test(%)as per IS 4984) |
2000.0 |
|
| - (Impact Strength as per IS 12235(Part 9)) |
2000.0 |
|
| - (Crush resistance) |
3000.0 |
|
|
| 380 |
IRC SP 80-2008 (2008) - Guidelines for Corrosion Prevention |
Guidelines for Corrosion Prevention |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Guidelines for corrosion prevention (Specific Gravity) |
1200.0 |
|
| Guidelines for corrosion prevention (Solid Contents) |
1500.0 |
|
| Guidelines for corrosion prevention (IR Spectrum (FTIR)) |
2000.0 |
|
| Guidelines for corrosion prevention (Adhesion with concrete (ASTM D 4541)) |
10000.0 |
|
| Guidelines for corrosion prevention (Dry Film Thickness (for minimum 2 coats)) |
1200.0 |
|
| Guidelines for corrosion prevention (Coverage (2 coats)) |
1200.0 |
|
| Guidelines for corrosion prevention (Water proofing characteristics (DIN 1048/ISO 12290)) |
10000.0 |
|
| Guidelines for corrosion prevention (Re-coatability) |
1200.0 |
|
| Guidelines for corrosion prevention (Water Vapour Transmission (ASTM D 1653)) |
5000.0 |
|
| Guidelines for corrosion prevention ((%) Elongation (ASTM D 2370)) |
2000.0 |
|
| Guidelines for corrosion prevention (Tensile strength (ASTM D 2370)) |
2000.0 |
|
| IRC SP 80 (UV Accelerated Weathering Test (ASTM G 53) 400 hrs) |
24000.0 |
|
|
| 381 |
IS 15769 (2008) - Flux Cored (Tubular) Electrodes for Gas Shielded and Self Shielded Metal welding of Carbon or Carbon Manganese Steel |
Flux Cored (Tubular) Electrodes for Gas Shielded and Self Shielded Metal welding of Carbon or Carbon Manganese Steel |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 4.1 (Diameter of Core Wire) |
500.0 |
|
| 4.2 (Temper) |
1000.0 |
|
| 4.2 (Cast) |
500.0 |
|
| 4.2 (Helix) |
500.0 |
|
| 4.3 (Uniformity) |
500.0 |
|
| 4.4.2 (Coils with Former, Overall Diameter, A) |
500.0 |
|
| 4.4.2 (Coils with Former, Width, B) |
500.0 |
|
| 4.4.2 (Coils with Former, Inner Diameter, C) |
500.0 |
|
| 4.4.2 (Coils with Former, Inner Diameter, C, Max) |
500.0 |
|
| 4.4.3 (Spools, Overall Diameter A) |
500.0 |
|
| 4.4.3 (Spools, Overall Width, B) |
500.0 |
|
| 4.4.3 (Spools, Inner Diameter, C) |
500.0 |
|
| 4.4.3 (Spools, Distance Between Axes D) |
500.0 |
|
| 4.4.3 (Spools, Driving Hole Diameter E) |
500.0 |
|
| 4.4.3 (Spools, Weight, Max) |
500.0 |
|
| 5.8 (Chemical Analysis) |
5000.0 |
|
| 5.2 (Radiographic Examination) |
1500.0 |
|
| 5.3 (Tensile Test) |
3000.0 |
|
| 5.4 (Charpy Impact Test) |
3000.0 |
|
| 5.1.3.2 (Dimension of Fillet Weld) |
500.0 |
|
| 5.1.3.2 (Fillet Weld Fracture) |
4000.0 |
|
| 5.5 (Transverse Tensile Test) |
3000.0 |
|
| 5.6 (Longitudinal Guided Bend Test) |
1000.0 |
|
| 5.7 (Diffusible Hydrogen Test) |
5000.0 |
|
|
| 382 |
Customized Specification for Struct Guard Carbon Sheet - Customized Specification for Struct Guard Carbon Sheet |
Customized Specification for Struct Guard Carbon Sheet |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| - (Tensile Strength(N/sq.mm.) as per ASTM D 3039) |
2000.0 |
|
| - (Tensile Modulus(N/sq.mm) as per ASTM D 3039) |
2000.0 |
|
| - (Elongation(%) as per ASTM D 3039) |
2000.0 |
|
|
| 383 |
NTH/WR/ME(CAL)/SOP/07 - Calibration of Measuring Tape |
Calibration of Measuring Tape |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Linear Measurment of Measuring Tape (up to 1 meter)) |
1200.0 |
|
| 2 (Linear Measurment of Measuring Tape (up to 3 meter)) |
2000.0 |
|
| 3 (Linear Measurment of Measuring Tape (up to 5 meter)) |
2500.0 |
|
| 4 (Linear Measurment of Measuring Tape (up to 15 meter)) |
3500.0 |
|
| 5 (Linear Measurment of Measuring Tape (up to 50 meter)) |
5000.0 |
|
|
| 384 |
NTH/WR/ME(CAL)/SOP/06 (2023) - Calibration of Measuring Steel Scale (0-1000mm) |
Calibration of Measuring Steel Scale (0-1000mm) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Linear Measurment of Steel Scale (0-300mm)) |
1200.0 |
|
| 2 (Linear Measurment of Steel Scale (0-600mm)) |
1200.0 |
|
| 3 (Linear Measurment of Steel Scale (0-1000mm)) |
1200.0 |
|
|
| 385 |
NTH/WR/ME(CAL)/SOP/05 (2023) - Calibration of Direct Pressure Indicating Device |
Calibration of Direct Pressure Indicating Device |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Calibration of Direct Pressure Indicating device/Master Pressure Gauge (Range 1 to 690) bar
by Comparison Method) |
3000.0 |
|
|
| 386 |
NTH/WR/ME(CAL)/SOP/04 (2023) - Verification of UTM/Tension/Compression Testing Machine |
Verification of UTM/Tension/Compression Testing Machine |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Calibration of UTM in Tension Mode up to 50kN (1 Scale)) |
6000.0 |
|
| 2 (Calibration of UTM in Compression Mode up to 500kN (1 Scale)) |
7000.0 |
|
|
| 387 |
NTH/WR/ME(CAL)/SOP/01 (2023) - Calibration of External Micrometer |
Calibration of External Micrometer |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Calibration of External Micrometer (up to 25mm)) |
1200.0 |
|
|
| 388 |
NTH/WR/ME(CAL)/SOP /03 (2023) - Calibration of Test Sieves for Wire Cloth Test Sieves and Perforated Plate Test Sieves |
Calibration of Test Sieves for Wire Cloth Test Sieves and Perforated Plate Test Sieves |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Test Sieves ( Aperture Size By Comparison Method - Tool Maker Microscope)) |
2000.0 |
|
| 2 (Test Sieves ( Aperture Size By Comparison Method - Vernier Caliper)) |
2000.0 |
|
|
| 389 |
NTH/WR/ME(CAL)/SOP /02 (2023) - Calibration of Vernier Caliper/Digital Caliper |
Calibration of Vernier Caliper/Digital Caliper |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Dimension - Length ( Range 0-300mm)) |
1200.0 |
|
| 2 (Dimension - Length ( Range 0-600mm)) |
2000.0 |
|
| 3 (Dimension-Length ( Range 0-1000mm)) |
2000.0 |
|
|
| 390 |
IS 16491 : Part 1 (2024) - Geometrical product specifications (GPS) - Dimensional measuring equipment: Part 1 calipers; design and metrological characteristics |
Geometrical product specifications (GPS) - Dimensional measuring equipment: Part 1 calipers; design and metrological characteristics |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5 (Length) |
1200.0 |
|
| 5 (Length) |
2000.0 |
|
| 5 (Length) |
2000.0 |
|
| 5 (Length) |
2000.0 |
|
|