| 1 |
CSD PaperBox Tissues - CSD PaperBox Tissues |
CSD PaperBox Tissues |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| - (CSD Index no. and attached annexure) |
6000.0 |
|
|
| 2 |
CSD Oxo Biodegradable Garbage bag - CSD Oxo Biodegradable Garbage bag |
CSD Oxo Biodegradable Garbage bag |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| - (CSD Index no. and attached annexure) |
5000.0 |
|
|
| 3 |
CSD Brush - CSD Brush |
CSD Brush |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| - (As per CSD Index no. and attached annexure) |
6000.0 |
|
|
| 4 |
CSD Ladies handbag - CSD Ladies handbag |
CSD Ladies handbag |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| - (As per CSD Index no. and attached annexure) |
5500.0 |
|
|
| 5 |
CSD Bagpack - CSD Bagpack |
CSD Bagpack |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| - (As per CSD Index no. and attached annexure) |
6000.0 |
|
|
| 6 |
CSD Cello Opalware Dinnerset - CSD Cello Opalware Dinnerset |
CSD Cello Opalware Dinnerset |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| - (As per CSD Index and attached annexure) |
10000.0 |
|
|
| 7 |
CSD-TDS Samples (2023-12) - CSD TDS ALL Index |
CSD TDS ALL Index |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Dimensions) |
1000.0 |
|
| 2 (Weight) |
1000.0 |
|
| 3 (Colour (visual)) |
1000.0 |
|
| 4 (Design (visual as per TDS)) |
1000.0 |
|
| 5 (Composition/Active Ingredients (visual)) |
1000.0 |
|
| 8 (Raw material/Fillers (Visual/Standard method)) |
2000.0 |
|
| 9 (Parts and their specification (Visual Annexure-1)) |
1000.0 |
|
| 10 (Identification Marks/Marking (visual)) |
1000.0 |
|
| 11 (item as SECONDS (visual)) |
1000.0 |
|
| 12 (Finish and Workmanship (visual)) |
1000.0 |
|
| 13 (Mesh GSM) |
1000.0 |
|
| 14 (Lace Strength) |
2000.0 |
|
| 15 (Lining GSM) |
1000.0 |
|
| 16 (Synthetic GSM) |
1000.0 |
|
| 17 (item as REJECT (visual)) |
1000.0 |
|
| 18 (Capacity with Tolerance (ID)) |
1000.0 |
|
| 19 (Capacity in volume, Ltrs.) |
1000.0 |
|
| 20 (Luggage Type(visual)) |
1000.0 |
|
| 21 (Fabric (Polyester)) |
2000.0 |
|
| 22 (Wheels (visual)) |
1000.0 |
|
| 23 (Locks (FCL) (visual)) |
1000.0 |
|
| 24 (Interior - Polyester Lining) |
2000.0 |
|
| 25 (Interior packing Strap (visual)) |
1000.0 |
|
| 26 (Interior- One Net pad pocket (visual)) |
1000.0 |
|
| 27 (Puller (visual)) |
1000.0 |
|
| 28 (Trolley(visual)) |
1000.0 |
|
| 29 (Handle (visual)) |
1000.0 |
|
| 30 (Pocket (visual)) |
1000.0 |
|
| 31 (Visual Inspection) |
1000.0 |
|
| 32 (Polyester Fabric (material)) |
2000.0 |
|
| 33 (Combination Lock (visual)) |
1000.0 |
|
| 34 (Trolley system (visual)) |
1000.0 |
|
| 35 (Expandable features (visual)) |
1000.0 |
|
| 36 (Front zipper pocket(visual)) |
1000.0 |
|
| 37 (Wheeling system 360deg (visual)) |
1000.0 |
|
| 38 (Internal packing pocket (visual)) |
1000.0 |
|
| 39 (Full side corner guards (visual)) |
5.0 |
|
| 40 (Nylon Twill fabric (material identification)) |
2000.0 |
|
| 41 (Three compartment and Padded Handle (visual)) |
1000.0 |
|
| 42 (Two Water Bottle Holder (visual)) |
1000.0 |
|
| 43 (Multilevel organiser and coin pouch (visual)) |
1000.0 |
|
| 44 (Front and Secret pocket (visual)) |
1000.0 |
|
| 45 (Interior Skybag Logo Printed (visual)) |
1000.0 |
|
| 46 (Interior One main compartment with top, bottom and side opening (visual)) |
1000.0 |
|
| 47 (Interior Side mesh pocket (visual)) |
1000.0 |
|
| 48 (Interior Top pocket (visual)) |
1000.0 |
|
| 49 (Raincover (visual)) |
1000.0 |
|
| 50 (600D Polyester with EVA lamination on Front) |
4000.0 |
|
| 51 (Steel square trolley with push button (visual)) |
5.0 |
|
| 52 (1U shape pocket (visual)) |
1000.0 |
|
| 53 (EVA Laminated on back (Material identification)) |
2000.0 |
|
| 54 (Non Padded Handle (visual)) |
1000.0 |
|
| 55 (Shoulder Carrying Strap in Webbing (visual)) |
1000.0 |
|
| 56 (170D Lining inside with Safari Logo (visual)) |
1000.0 |
|
| 57 (Composition/Active Ingredients GM Chopper (Standard method)) |
12000.0 |
|
| 58 (Packing type & Specification (visual)) |
1000.0 |
|
| 59 (Colour Fastness to Light) |
5000.0 |
|
| 60 (Material 100% Cotton) |
2000.0 |
|
| 61 (Colour fastness to Rubbing (Dry and Wet)) |
4000.0 |
|
| 62 (Colour Fastness to Washing, change in colour) |
2000.0 |
|
| 63 (As per Annexure) |
10000.0 |
|
|
| 8 |
IS 16286 (2014) - Spoons - Specification |
Spoons - Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 4 (Dimensions) |
2000.0 |
|
| 5 (Manufacture, Workmanship and Finish) |
500.0 |
|
| 6.1 (Staining test) |
1000.0 |
|
| 6.2 (Bending test) |
1000.0 |
|
| 6.3 (Load test) |
1000.0 |
|
| 6.4.1 (Boiling test) |
2000.0 |
|
| 6.4.2 (Impact test) |
1000.0 |
|
| 3 (Materials) |
3500.0 |
|
|
| 9 |
IS 15905 (2024) - Hubless Centrifugally Cast (Spun) Iron Pipes, Fittings and Accessories — Spigot Series — Specification( First Revision ) |
Hubless Centrifugally Cast (Spun) Iron Pipes, Fittings and Accessories — Spigot Series — Specification( First Revision ) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 7 (Visual Inspection and Hammer Test as per IS 15905) |
1000.0 |
|
| 8 (Crush Tests on Pipes Ring as per IS 15905) |
2000.0 |
|
| 9 (Hydrostatic Test as per IS 15905) |
2500.0 |
|
| 10 (Dimensions and Tolerances as per IS 15905 (> 10 measurments)) |
2000.0 |
|
|
| 10 |
IS 4270 (2001) - Steel tubes used for water wells specification (Third Revision) |
Steel tubes used for water wells specification (Third Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5.2 (Chemical analysis) |
2500.0 |
|
| 9 (Outside diameter) |
3000.0 |
|
| 6.2 (Flattening) |
1000.0 |
|
| 6.1 (Tensile test) |
3000.0 |
|
| 7 (Weight in kg/m) |
1000.0 |
|
| 7 (Length) |
250.0 |
|
| 7 (Thickness) |
250.0 |
|
| 7 (Outside diameter) |
250.0 |
|
| 14 (Visual examination) |
1000.0 |
|
| 5.2 (Sulphur) |
1250.0 |
|
| 6.2 (Flattening Test) |
1500.0 |
|
| 6.1 (% Elongation) |
1000.0 |
|
| 6.1 (Tensile Strength) |
1000.0 |
|
| 6.1 (Yield Strength) |
1000.0 |
|
| 7 (Thickness) |
1000.0 |
|
| 14 (Workmanship) |
1000.0 |
|
| 5.2 (Phosphorus) |
1250.0 |
|
|
| 11 |
BS EN 12467 (2012) - Fibre - cement flat sheets - Product specification and test method. |
Fibre - cement flat sheets - Product specification and test method. |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5.3.2 (Nominal Length, in mm) |
500.0 |
|
| 5.3.2 (Nominal Width, mm) |
500.0 |
|
| 503.3 (Thickness, in mm) |
1000.0 |
|
| 5.3.4.1 (Tolerance on length, in mm) |
500.0 |
|
| 5.3.4.1 (Tolerance in Width, in mm) |
500.0 |
|
| 5.3.4.2 (Tolerance on thickness, in mm or %) |
500.0 |
|
| 5.3.5.1 (Straightness of Edges, in %) |
500.0 |
|
| 5.3.5.2 (Squareness of edges, in mm/m) |
500.0 |
|
| 5.4.2 (Apparent Density) |
1000.0 |
|
| 5.4.3 (Moisture Movement, in %) |
2000.0 |
|
| 5.4.4 (Bending Strength (MOR) in Ambient Laboratory condition, in MPa.) |
4000.0 |
|
| 5.4.4 (Bending Strength (MoR) in Wet Condition, MPa) |
8000.0 |
|
| 5.4.5 (Water Impermeability,) |
4000.0 |
|
| 5.5.2 (Freeze Thaw Test) |
25000.0 |
|
| 5.5.4 (Warm Water Durability test) |
25000.0 |
|
| 5.5.5 (Soak Dry Durability Test) |
25000.0 |
|
|
| 12 |
Custom - Concrete - Custom Physical Tests on hardened Concrete |
Custom Physical Tests on hardened Concrete |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| - - (Compressive Strength , MPa) |
1200.0 |
|
| - - (Water Absorption) |
1000.0 |
|
| - - (Water Absorption after 24 hours) |
1000.0 |
|
| - - (Density of concrete) |
1000.0 |
|
|
| 13 |
NTH/WR/RPPT/Inspection of Paper - NTH/WR/RPPT/Inspection of Paper |
NTH/WR/RPPT/Inspection of Paper |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| - (Paper Inspection Report) |
30798.0 |
|
|
| 14 |
NTH/WR/RPPT/2025/Inspection of papers - Inspection of Papers [-] |
Inspection of Papers |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| - (Firms requirements) |
115000.0 |
|
|
| 15 |
NTH/NR/RPPT/Paper Inspection (2024) - Inspection of Papers |
Inspection of Papers |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Firm's Requirements (Inspection Report) |
99225.0 |
|
|
| 16 |
Custom - Cement Sand mix. - Cement - Sand Mix. [- -] |
Cement - Sand Mix. |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| -- (Sand Content and cement content, %) |
3000.0 |
|
| - - (Visual Examination) |
2000.0 |
|
| - - (Physical Properties) |
2000.0 |
|
| - - (Chemical composition of cement) |
5000.0 |
|
|
| 17 |
Custom (0) - Cement Sand ratio |
Cement Sand ratio |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1. (Cement sand ratio) |
5000.0 |
|
|
| 18 |
IS 2347 (2023) - Domestic pressure cooker - Specification (Sixth Revision) |
Domestic pressure cooker - Specification (Sixth Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 4.1 (Capacity) |
500.0 |
|
| 6.1.1 (Vent pipe inside diameter) |
500.0 |
|
| 8.1 (Air Pressure of domestic pressure cooker) |
1000.0 |
|
| 8.2 (Proof Pressure of domestic pressure cooker) |
2000.0 |
|
| 8.3 (Operating pressure for Pressure Regulating Device) |
1000.0 |
|
| 8.4.1 Annex-H cl. No. H-1.1 (Operating pressure of Safety Pressure Relief Device for destructible device) |
1000.0 |
|
| 8.6.1 (Removal of Lid under Pressure (For Outer Lid Cooker)) |
1000.0 |
|
| 8.6.2 (Removal of Lid under Pressure (For Inner Lid Cooker)) |
1000.0 |
|
| 8.5 (Bursting Pressure Test) |
3000.0 |
|
| 5.3 (Performance Test on Gasket) |
1000.0 |
|
| 7.4 Annex-E cl. No. E-2 (Coating thickness for body) |
2000.0 |
|
| 7.4 Annex-E cl. No. E-3 (Abrasion resistance for body) |
500.0 |
|
| 7.4 Annex-E cl. No. E-4 (Micro Vickers Hardness for body) |
2000.0 |
|
| 8.9 (Test for Induction Bottom) |
5000.0 |
|
| TDS 1 (Weight, kg.) |
- |
|
| 5.1 (Chemical Composition, % by mass.) |
6000.0 |
|
| TDS-2 (Overall Dimension- Thickness, mm.) |
- |
|
| 7.4 Annex-E cl. No. E-2 (Coating thickness for lid) |
2000.0 |
|
| 7.4 Annex-E cl. No. E-3 (Abrasion resistance for lid) |
500.0 |
|
| 7.4 Annex-E cl. No. E-4 (Micro Vickers Hardness for lid) |
2000.0 |
|
| 5.4 (Performance test for pressure cooker handle as per IS 13395) |
11000.0 |
|
| 0 (Test Result as per Annexure.) |
20000.0 |
|
| 8.4.1 Annex-H cl. No. H-1.2 (Operating pressure of Safety Pressure Relief Device for Gasket Release System.) |
1000.0 |
|
| 0 (CSD - Pressure Cooker -All Possible Test as per TDS and IS 2347) |
5000.0 |
|
|
| 19 |
IS 14255 (1995) - "AERIAL BUNCHED CABLES-FOR WORKING VOLTAGES UPTO AND INCLUDING 11OOVOLTS " |
"AERIAL BUNCHED CABLES-FOR WORKING VOLTAGES UPTO AND INCLUDING 11OOVOLTS " |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 10.1 (Type tests) |
20000.0 |
|
| 10.2 (Acceptance tests) |
10000.0 |
|
|
| 20 |
14255 (1995) - Aerial Bunched Cables for working
voltages up to and including 1100 Volts-Reaffirmed 2020 specification |
Aerial Bunched Cables for working
voltages up to and including 1100 Volts-Reaffirmed 2020 specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
| 21 |
IS 10322 : PART 5 : SEC 3 (2012) - Luminaires: Part 5 particular requirements: Sec 3 luminaires for road and street lighting (First Revision) |
Luminaires: Part 5 particular requirements: Sec 3 luminaires for road and street lighting (First Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 9 (Provision for earthing) |
1200.0 |
|
| 12 (Protection against Electric Shock) |
1200.0 |
|
|
| 22 |
IS 733 (1983 RA 2022) - SPECIFICATION FOR WROUGHT ALUMINIUM AND ALUMINIUM ALLOY BARS, RODS AND SECTIONS
(FOR GENERAL ENGINEERING PURPOSES) |
SPECIFICATION FOR WROUGHT ALUMINIUM AND ALUMINIUM ALLOY BARS, RODS AND SECTIONS
(FOR GENERAL ENGINEERING PURPOSES) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5.1.1 a Chemical composition (Aluminium (as Al )content,% by mass) |
3000.0 |
|
| 5.1.1 b Chemical composition (Copper (as Cu)content,% by mass) |
500.0 |
|
| 5.1.1 C Chemical composition (Magnesium(as Mg ) content,% by mass) |
500.0 |
|
| 5.1.1 d Chemical composition (Silicon (as Si) content,% by mass) |
500.0 |
|
| 5.1.1 e Chemical composition (Iron (as Fe) content,% by mass) |
500.0 |
|
| 5.1.1 f Chemical composition (Manganese (as Mn) content,% by mass) |
500.0 |
|
| 5.1.1 g Chemical composition (Zinc (as Zn ) content,% by mass) |
500.0 |
|
| 5.1.1 h Chemical composition (Titanium (as Ti) content,% by mass) |
500.0 |
|
| 5.1.1 i Chemical composition (Chromium (as Cr) content,% by mass) |
500.0 |
|
| 5.1.1 j Chemical composition (Vanadium (as V) content,% by mass) |
500.0 |
|
| 7 (Dimension) |
1000.0 |
|
| 9.1 (Tensile Strenth) |
2000.0 |
|
| 9.1 (0.2% Proof Stress) |
1000.0 |
|
| 9.1 (Elongation) |
1000.0 |
|
| 5 (Chemical composition, % by mass) |
6000.0 |
|
| 0 (Anodic Coating) |
2000.0 |
|
| 0 (Weight, kg) |
1000.0 |
|
|
| 23 |
Shore D hardness - Shore D hardness |
Shore D hardness |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| - (Shore D hardness) |
1000.0 |
|
|
| 24 |
4021 (1995 Reaf. 2022) - Timber Door, Window and Ventilator Frames |
Timber Door, Window and Ventilator Frames |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 4.1 (Specific Gravity / Density, g/cc (kg/cum)) |
1000.0 |
|
| 4.1.2 (Moisture Content, %) |
1000.0 |
|
| 6.2 (Size and Type) |
1000.0 |
|
| 6.1 (Dimensions of Frame and Tolerances, in mm) |
1000.0 |
|
|
| 25 |
Manufacturer/Customer's specifications & GTP - Manufacturer/Customer's specifications & GTP |
Manufacturer/Customer's specifications & GTP |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1.00 (Conformity Tests for Battery operated platform truck as per IS: 10311-1982) |
30000.0 |
|
| 1.00 (AC High Voltage Test at power frequency) |
5000.0 |
|
| 1.00 (Neutral Grounding Resistance (Grid Resistance)-03 Resistors) |
30000.0 |
|
| 1.00 (Neutral Grounding Resistance (Grid Resistance) Single Resistor) |
10000.0 |
|
| 1.00 (Neutral Grounding Resistance (Grid Resistance) Two Resistor) |
20000.0 |
|
|
| 26 |
IS 650:1991 - Standard sand for testing cement |
Standard sand for testing cement |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 4.2 (Size-Sieve analysis -Particle size distribution) |
2000.0 |
|
| 5.1 (The loss of mass -on extraction with hot HCl) |
1200.0 |
|
| 5.1 (Organic Impurities) |
1000.0 |
|
|
| 27 |
IS 8662 (2004) - Enamel, synthetic exterior: (A) undercoating (B) finishing, for railway coaches - Specification (Second Revision) |
Enamel, synthetic exterior: (A) undercoating (B) finishing, for railway coaches - Specification (Second Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6.6.xiii (Keeping properties) |
5000.0 |
|
| 6.6.xii (Accelerated storage stability test, at 60 degC, 96 h) |
3000.0 |
|
| 6.6.xi.b (Phthalic anhydride content of
non-volatile vehicle) |
3000.0 |
|
| 6.6.xi.a (Volume solids) |
3000.0 |
|
| 6.6.x (Flash point) |
1500.0 |
|
| 6.6.ix (Flexibility and adhesion) |
1200.0 |
|
| 6.6.viii (Scratch hardness after 48 h air
drying (1 000 g weight)) |
1500.0 |
|
| 6.6.vii (Water content (if suspected to be present) - IS 101 (Part 2/Sec 1)) |
1200.0 |
|
| 6.6.vi (Colour) |
1200.0 |
|
| 6.6.v (Fineness of grind,) |
1200.0 |
|
| 6.6.iv.b (Gloss , 60 deg) |
1500.0 |
|
| 6.6.iv.a (Fnish) |
1200.0 |
|
| 6.6.iii.d (Drying time Tack Free) |
1200.0 |
|
| 6.6.iii.c (Hard dry at 70 DegC
with 15 min flash-
off time) |
1200.0 |
|
| 6.6.iii.a (Drying time Surface Dry) |
1200.0 |
|
| 6.6.ii (Mass, in kg/101itres) |
1500.0 |
|
| 6.6.i.b (Viscosity byFord cup No. 4) |
1200.0 |
|
| 6.6.i.a (Consistency) |
1200.0 |
|
| 6.5 (Resistance to Alkali (for Finishing Only) |
1500.0 |
|
| 6.4 (Resistance to Acid (for Finishing Only)) |
1500.0 |
|
| 6.3 (Durability( Normal Outdoor Exposer)) |
10000.0 |
|
| 6.2.6 (Application Properties) |
1200.0 |
|
| 6.2.5 (Thinning Properties) |
1200.0 |
|
| 6.2.4 (Skin Formation) |
1200.0 |
|
| 6.2.3 (Freedom from Coarse Particles) |
1200.0 |
|
| 6.2 (Condition in Container) |
1200.0 |
|
| CLAUSE-4.5.2,Table-1 (Dry Film Thickness(DFT)) |
1500.0 |
|
| 6.7 (Pigment content) |
1000.0 |
|
| Cl.6.8 Table 2 (Test Result, General parameters only- (Please see Annexure)) |
10000.0 |
|
| ICF/MD/Specn. 045 (Durability test (QUV Accelerated Weathering, 250 Hrs), Accelerated Storage Test, Wet abrasion test) |
20000.0 |
|
| Enamel, synthetic exterior: (A) undercoating (B) finishing, for railway coaches - Specification (Second Revision) (Keeping Properties 12 months) |
5000.0 |
|
|
| 28 |
General RDSO Specification NTH WR - General RDSO Specification NTH WR [-] |
General RDSO Specification NTH WR |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| General RDSO Specification NTH WR (Painting system of FRP Components- MTDS: 118 REV 01: - 2-Component polyurethane Base Primer) |
15900.0 |
|
| General specification RDSO (Painting system of FRP Components- MTDS: 118 REV 01: - 2-Component polyurethane Base Primer for 12 months Keeping properties) |
10000.0 |
|
|
| 29 |
NTH(WR)/MECH/CUSTOM/029 (2025) - Student Bench - Specification for Student Bench |
Specification for Student Bench |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Type of Seating, Suitable for age group, Number of Seating Capacity
Desk with Self (Under Storage)
Height, Width and Length
MS Pipe Size, MS Pipe gauge (Thickness), MS Pipe Frame size
Supportign MS Pipe and Supporting Angle size
BEJ Type
SAG Border Patti
Writing Pad
Bag Bad
Back Hight, Back Length
Color of Buch
Fitting Type
Finishing) |
6500.0 |
|
|
| 30 |
NTH(WR)/MECH/CUSTOM/028 (2025) -Breathing Air Compressor (2025) - High Pressure, 3 Stage, Reciprocating type, Air cooled, Oil Lubricated Breathing Air Compressor |
High Pressure, 3 Stage, Reciprocating type, Air cooled, Oil Lubricated Breathing Air Compressor |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Acceptance Test -Customer Specification: (Ref, Stanadrd IS 15879:2009 and Customer Acceptance Test Procedure Annexure-A , B & C)
1. Specification Check - Scope Verification and Air flow diagram verification (As per sketch)
2. Weights and Measures
3. Records of Test Run Parameters- Medium, Intake pressure, Final discharge Pressure,
3. a.Air Leak test- Leak detector spray Method
3.b. Noise / sound level HP air compressor- ≤85 db(A) at a distance of 1meter
3.c Calculated capacity LPM - Customer Specified Method
4. Record of Functional Test - Safety Relief Valve ( 330 bar +/- 10% and 225 bar +/- 10%), Functioning of
Condensate drain) |
28000.0 |
|
| 2 (Acceptance Test Procure reference with IS 15879:2009
Verification of material of construction -
Method of Checking Magnetic or Non Magnetic Type
Crankcase, Cylinders,Cylinder Heads, Crankshaft, Connecting rods, Pistons, Valves and Flywheel) |
8000.0 |
|
|