| 2701 |
National Test House (ER), Kolkata
| IS 2645 (2003) - Integral waterproofing compounds for cement mortar and concrete - Specification (Second Revision) |
Integral waterproofing compounds for cement mortar and concrete - Specification (Second Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 3.3.b (Compressive Strength-7days) |
2000.0 |
|
| 3.3.a (Compressive Strength-3 days) |
2000.0 |
|
| 3.2.b (Setting Time (Final Setting Time)) |
500.0 |
|
| 3.2.a (Setting Time (Initial Setting Time)) |
500.0 |
|
| 3.4 (Chloride Content, %) |
1000.0 |
|
|
| 2702 |
National Test House (NR), Ghaziabad
| IRS-T-46-2023 (2023) - INDIAN RAILWAY STANDARD SPECIFICATION FOR SPHEROIDAL GRAPHITE CAST IRON INSERTS |
INDIAN RAILWAY STANDARD SPECIFICATION FOR SPHEROIDAL GRAPHITE CAST IRON INSERTS |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
| 2703 |
National Test House (NR), Ghaziabad
| IRS-T-46 (1996) - Indian Railway Standard Specification for Spheroidal Graphite Cast Iron Inserts |
Indian Railway Standard Specification for Spheroidal Graphite Cast Iron Inserts |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
| 2704 |
National Test House (NR), Ghaziabad
| IS 6006 (2014) - Uncoated stress relieved strand for prestressed concrete - Specification (Second Revision) |
Uncoated stress relieved strand for prestressed concrete - Specification (Second Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 7.3 (3- Ply 3mm strand: Elongation) |
1000.0 |
|
| 7.2 (3- Ply 3mm strand: 0.2% Proof Load) |
1000.0 |
|
| 7.1 (3- Ply 3mm strand: Breaking Load, kN) |
3000.0 |
|
| 5.1 (Nominal Mass 3- Ply 3mm strand) |
1000.0 |
|
| 5.1 (Nominal Area 3- Ply 3mm strand) |
500.0 |
|
| 5.1 (Dimension 3- Ply 3mm strand: Nominal Diameter of element wire) |
500.0 |
|
| 4.2 (Length of lay of 3- Ply 3mm strand: 24-36 time of dia of element wire) |
1000.0 |
|
| 3.1.2 (Sulphur, % by mass.) |
750.0 |
|
| 3.1.2 (Phosphorus, % by mass) |
750.0 |
|
| 3.1.2 (Carbon, % by mass.) |
625.0 |
|
|
| 2705 |
National Test House (NR), Ghaziabad
| IRS T-46 (1996) - Indian Railway Standard Specification For Spheroidal Graphite Cast Iron Inserts |
Indian Railway Standard Specification For Spheroidal Graphite Cast Iron Inserts |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 13 (Weight) |
1000.0 |
|
| 12 (Dimensions) |
1000.0 |
|
| 11.7 (Internal Soundness) |
1000.0 |
|
| 11.6 (Micro Structure) |
2000.0 |
|
| 11.5 (Brinell Hardness) |
2000.0 |
|
| 11.4 (Elongation) |
3000.0 |
|
| 11.4 (Tensile Strength) |
3000.0 |
|
| 11.2 (Chemical Composition) |
2500.0 |
|
|
| 2706 |
National Test House (ER), Kolkata
| JIS D 5302-2004 - Lead Acid Batteries for Motorcycles |
Lead Acid Batteries for Motorcycles |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 8.3.2 (Capacity (10 hour rate)) |
25000.0 |
|
| 8.3.3 (High Rate Discharge test) |
15000.0 |
|
| 8.3.4 (Vibration resistance) |
20000.0 |
|
| Reference 1 (Deep Cycle Endurance) |
60000.0 |
|
| Reference 2 (Shallow Cycle Endurance) |
60000.0 |
|
| Reference 3 (Characteristics of Electrolyte Decrease) |
30000.0 |
|
| Reference 4 (Charge Retention test) |
20000.0 |
|
| 8.3.1 (Dimensions) |
1000.0 |
|
|
| 2707 |
National Test House (ER), Kolkata
| JISC 8702 : 2009 - Small- sized valve regulated lead-acid batteries |
Small- sized valve regulated lead-acid batteries |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 4 of JISC 8702-2:2009 (Dimensions) |
500.0 |
|
| 5.1 of JISC 8702-1:2009 (Capacity at 20 hr rate) |
20000.0 |
|
| 5.2 of JISC 8702-1:2009 (High rate discharge characteristics) |
20000.0 |
|
| 5.3 of JISC 8702-1:2009 (Cycle service Endurance) |
200000.0 |
|
| 5.4 of JISC 8702-1:2009 (Storage characteristic Test) |
20000.0 |
|
| 5.5 of JISC 8702-1:2009 (Maximum permissible current Characteristic) |
15000.0 |
|
| 5.6 of JISC 8702-1:2009 (Charge Acceptance characteristic after deep discharge.) |
15000.0 |
|
| 5.7 of JISC 8702-1:2009 (Endurance in Trickle application) |
100000.0 |
|
| 5.8 of JISC 8702-1:2009 (Endurance in trickle application at 40 Deg C) |
130000.0 |
|
| 5.9.a of JISC 8702-1:2009 (Gas Emission Intensity I) |
15000.0 |
|
| 5.10.a of JISC 8702-1:2009 (Gas recombinating characteristic - operation of vent valve) |
15000.0 |
|
| 5.11 of JISC 8702-1:2009 (Vibration Resistance Characteristics) |
15000.0 |
|
| 7.12 of JISC 8702-1:2009 (Shock Resistance Characteristics) |
15000.0 |
|
| 7.1.b (Actual Capacity at the 1 hour discharge rate) |
20000.0 |
|
| 5.10.b of JISC 8702-1:2009 (Gas recombinating characteristic - Liquid leakage resistance characteristics) |
15000.0 |
|
| 5.9.b of JISC 8702-1:2009 (Gas emission intensity II) |
15000.0 |
|
|
| 2708 |
National Test House (ER), Kolkata
| CQAL/637 :2006 - SPECIFICATION FOR BATTERY SECONDARY, LEAD ACID, LOW MAINTENANCE FOR MT PURPOSES |
SPECIFICATION FOR BATTERY SECONDARY, LEAD ACID, LOW MAINTENANCE FOR MT PURPOSES |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 15.1 (Visual Examination) |
1000.0 |
|
| 15.2 (Physical Examination) |
1000.0 |
|
| 15.3 (Dimensions and Layout) |
1000.0 |
|
| 15.4 (Marking) |
1000.0 |
|
| 15.5 (Capacity (5-h rate)) |
5000.0 |
|
| 15.6.1 (High Rate Discharge at -15 degree C) |
10000.0 |
|
| 15.6.3 (High Rate Discharge at Normal Temperature) |
15000.0 |
|
| 15.7 (Robustness of Handle) |
5000.0 |
|
| 15.8 (Charge Acceptance) |
15000.0 |
|
| 15.9 (Air Pressure Test) |
10000.0 |
|
| 15.10 (Life Cycle test) |
100000.0 |
|
| 15.11 (Vibration Resistance) |
10000.0 |
|
| 15.12 (Over Charge Endurance) |
20000.0 |
|
| 15.13 (Strength of Terminal) |
5000.0 |
|
| 15.14 (Robustness to Fastening) |
5000.0 |
|
| 15.15 (Test for Dry Charged Battery) |
10000.0 |
|
| 15.16 (High Voltage Test) |
5000.0 |
|
| 15.17 (Retention of Charge) |
15000.0 |
|
| 15.18 (Electrolyte Retention test) |
5000.0 |
|
|
| 2709 |
National Test House (ER), Kolkata
| RDSO SPECIFICATION No. M&C/PCN/123/2018 (2018) - SPECIFICATION FOR HIGH PERFORM ANTI-CORROSION EPOXY COATING (TWO PACK) |
SPECIFICATION FOR HIGH PERFORM ANTI-CORROSION EPOXY COATING (TWO PACK) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
| 2710 |
National Test House (ER), Kolkata
| RDSO M&C/ PCN/ 100/ 2018 (2018) - Specification for Epoxy Cum Polyurethane Painting System (Two Pack) for the Exterior Painting of Railway Coaches |
Specification for Epoxy Cum Polyurethane Painting System (Two Pack) for the Exterior Painting of Railway Coaches |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Chapter V (Table 1) (Viscosity (Efflux time by Ford cup No. 4 ) at 27 degree C) |
1200.0 |
|
| Chapter V (Table 1) (Fineness of grind) |
1200.0 |
|
| Chapter V (Table 1) (Theoretical Spreading rate) |
1200.0 |
|
| Chapter V (Table 1) (Pot life(After induction time)ii) 40 ± 2 Deg C) |
2000.0 |
|
| Chapter V (Table 1) (Pot life (After induction time) at i) 27 ± 2 Deg C) |
1500.0 |
|
| Chapter V (Table 1) (Abrasion resistance-1000 cycles) |
3000.0 |
|
| Chapter V (Table 1) (Humidity test.) |
11000.0 |
|
| Chapter V (Table 1) (Durability Tests : Accelerated weathering test) |
110000.0 |
|
| Chapter V (Table 1) (Accelerated Tests Resistance to water) |
1500.0 |
|
| Chapter V (Table 1) (Accelerated Tests Resistance to solvents) |
1500.0 |
|
| Chapter V (Table 1) (Accelerated Tests Resistance to oil) |
1500.0 |
|
| Chapter V (Table 1) (Accelerated Tests Resistance to 20% caustic potash (weight by volume)) |
1500.0 |
|
| Chapter V (Table 1) (Accelerated Tests (a) Resistance to 30% Sulphuric acid (weight by volume)) |
1500.0 |
|
| Chapter V (Table 1) (poly isocyanate, in hardener) |
3000.0 |
|
| Chapter V (Table 1) (Unreacted monomer) |
3000.0 |
|
| Chapter V (Table 1) (Gloss at 60 degree angle of incidence) |
1200.0 |
|
| Chapter V (Table 1) (Mass in Kg/10 litres) |
1200.0 |
|
| Chapter V (Table 1) (Keeping Properties for both the packs) |
5000.0 |
|
| Chapter V (Table 1) (Flash Point (b) Component B) |
1200.0 |
|
| Chapter V (Table 1) (Flash Point (a) Component A) |
1200.0 |
|
| Chapter V (Table 1) (Flexibility & Adhesion (6.25mm mandrel)) |
1200.0 |
|
| Chapter V (Table 1) (Scratch hardness (1.5 Kg LOAD)) |
1200.0 |
|
| Chapter V (Table 1) (Volume solids) |
1200.0 |
|
| Chapter V (Table 1) (Dry film thickness/Per coat) |
1200.0 |
|
| Chapter V (Table 1) (Colour) |
1200.0 |
|
| Chapter V (Table 1) (Finish) |
1200.0 |
|
| Chapter V (Table 1) (Consistency) |
1200.0 |
|
| Chapter V (Table 1) (Drying time c) Hard Dry at 70 Deg C) |
1200.0 |
|
| Chapter V (Table 1) (Drying time b) Hard Dry) |
1200.0 |
|
| Chapter V (Table 1) (Drying time a) Surface Dry) |
1200.0 |
|
| Chapter V (Table 1) (Identification of polyisocyanates) |
3000.0 |
|
| Chapter II/Cl. 4.1 (Protection against corrosion under condition of condensation) |
9000.0 |
|
| Chapter II/Cl. 4.1 (Resistance to salt spray) |
21000.0 |
|
|
| 2711 |
National Test House (SR), Chennai
| Industrial Training - Industrial Training - Electrical Laboratory |
Industrial Training - Electrical Laboratory |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Industrial Training - Electrical Laboratory) |
1.0 |
|
|
| 2712 |
National Test House (ER), Kolkata
| NTHER- Calibration of High Current Source (V/I Method) More than 100A - Calibration of High Current Source (V/I Method) More than 100A |
Calibration of High Current Source (V/I Method) More than 100A |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| A.1 (Calibration of High Current Source (V/I Method) up to 500A (ac or dc)) |
4500.0 |
|
| A.2 (Calibration of High Current Source (V/I Method) up to 800A (ac or dc)) |
5000.0 |
|
| A.3 (Calibration of High Current Source (V/I Method) up to 1000A (ac or dc)) |
6000.0 |
|
|
| 2713 |
National Test House (ER), Kolkata
| ETI/OHE/50(6/97) re-designated to TI/SPC/OHE/CAT(Cu-Cd)/0971 (2021) - Technical specification for Cadmium copper conductors for over head Electric Traction |
Technical specification for Cadmium copper conductors for over head Electric Traction |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 8.2.1 (Visual examination) |
1000.0 |
|
| 8.2.2 (Chemical composition) |
2000.0 |
|
| 8.2.3 (Measurement of diameter of individual wire and stranded conductor) |
2000.0 |
|
| 8.2.4 (Measurement of weight of wire and conductor) |
2000.0 |
|
| 8.2.5 (Measurement of lay length and lay ratio of each layer of stranded conductor) |
5000.0 |
|
| 8.2.6 (Measurement of Electrical resistance of wire and stranded conductor) |
15000.0 |
|
| 8.2.7 (Tensile test on wires) |
32000.0 |
|
| 8.2.8 (Wrapping test on wires) |
5000.0 |
|
|
| 2714 |
National Test House (NR), Ghaziabad
| NTH/NR/RPPT/Sanitary Napkin (2022) - Sanitary Napkin (Firm's Requirement) |
Sanitary Napkin (Firm's Requirement) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1.1 (Pad Length) |
500.0 |
|
| 1.2 (Pad Thickness) |
500.0 |
|
| 1.3 (Pad Width) |
500.0 |
|
| 1.4 (Pad Weight) |
500.0 |
|
| 1.5 (Top Sheet/Outer covering layer of pad) |
1000.0 |
|
| 1.6 (Absorbent Filler Material) |
1000.0 |
|
| 1.7 (Side Wings/Tab) |
500.0 |
|
| 1.8 (Back Strip/Barrier/Bottom Sheet) |
2000.0 |
|
| 1.9 (Absorbency) |
1000.0 |
|
| 1.10 (Disposability) |
500.0 |
|
|
| 2715 |
National Test House (NER), Guwahati
| IS 733 (2025) - SPECIFICATION FOR WROUGHT ALUMINIUM AND ALUMINIUM ALLOY BARS, RODS AND SECTIONS
(FOR GENERAL ENGINEERING PURPOSES) |
SPECIFICATION FOR WROUGHT ALUMINIUM AND ALUMINIUM ALLOY BARS, RODS AND SECTIONS
(FOR GENERAL ENGINEERING PURPOSES) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5.1.1 a Chemical composition (Aluminium (as Al )content,% by mass) |
3000.0 |
|
| 5.1.1 b Chemical composition (Copper (as Cu)content,% by mass) |
500.0 |
|
| 5.1.1 C Chemical composition (Magnesium(as Mg ) content,% by mass) |
500.0 |
|
| 5.1.1 d Chemical composition (Silicon (as Si) content,% by mass) |
500.0 |
|
| 5.1.1 e Chemical composition (Iron (as Fe) content,% by mass) |
500.0 |
|
| 5.1.1 f Chemical composition (Manganese (as Mn) content,% by mass) |
500.0 |
|
| 5.1.1 g Chemical composition (Zinc (as Zn ) content,% by mass) |
500.0 |
|
| 5.1.1 h Chemical composition (Titanium (as Ti) content,% by mass) |
500.0 |
|
| 5.1.1 i Chemical composition (Chromium (as Cr) content,% by mass) |
500.0 |
|
| 5.1.1 j Chemical composition (Vanadium (as V) content,% by mass) |
500.0 |
|
|
| 2716 |
National Test House (ER), Kolkata
| NTHER-Calibration of Micro-ohm Meter - NTHER-Calibration of Micro-ohm Meter |
NTHER-Calibration of Micro-ohm Meter |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| A1 (Calibration of Micro-ohm Meter(1A)) |
2000.0 |
|
| A2 (Calibration of Micro-ohm Meter(100A)) |
3000.0 |
|
|
| 2717 |
National Test House (WR), Mumbai
| ASTM D 257 (1999) - Solid insulating materials |
Solid insulating materials |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Solid insulating materials) |
1000.0 |
|
|
| 2718 |
National Test House (SR), Chennai
| IS 15778 (2007) - Chlorinated polyvinyl chloride (Cpvc) pipes for potable hot and cold water distribution supplies - Specification |
Chlorinated polyvinyl chloride (Cpvc) pipes for potable hot and cold water distribution supplies - Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 10.1 (Hydrostatic Characteristics) |
5000.0 |
|
| 7.1.3 (Length) |
1000.0 |
|
| 7.1.2 (Wall Thickness) |
1000.0 |
|
| 7.1.1 (Diameter at any point ) |
1000.0 |
|
| 9.4 (Reversion Test) |
2000.0 |
|
| 9.6 (Density) |
1000.0 |
|
| 9.2 (Opacity) |
2000.0 |
|
| 10.4 (Flattening Test) |
2000.0 |
|
| 10.5 (Tensile Strength ) |
2000.0 |
|
| 9.5 (Vicat Softening Temperature) |
1500.0 |
|
| Firm's Request (Fitment Test) |
2000.0 |
|
| 10.3 (Resistance to External Blows) |
2000.0 |
|
|
| 2719 |
National Test House (SR), Chennai
| Customer Specification ALL (2022) - Cust Spfn. Test Result |
Cust Spfn. Test Result |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Footwear Test Results) |
5500.0 |
|
| 2 (Results of the Tests - Electrical) |
1500.0 |
|
| 2 (Results of Tests) |
6000.0 |
|
| 3 (Test Results) |
5500.0 |
|
| 5 (Effect on water) |
2000.0 |
|
| 6 (Results of the Test(All other Custom Test)) |
15500.0 |
|
| 7 (Results of Test(all other Custom tests)) |
14000.0 |
|
| 8 (Vicat Softening Temperature) |
1500.0 |
|
| 9 (Opacity Test) |
2000.0 |
|
| 10 (Results of the Test) |
- |
|
| 11 (Results of the Tests) |
5000.0 |
|
| 12 (100% Cotton Test) |
2000.0 |
|
| 13 (100% Cotton Test) |
2000.0 |
|
| 14 (Identification of Material) |
2000.0 |
|
| 15 (Results of the Tests Handloom Cotton Bed sheet) |
26400.0 |
|
| 16 (Results of the Tests firms requirement handloom cotton bed sheet) |
9400.0 |
|
| 17 (Results of the Test Custom spfn) |
11000.0 |
|
| 18 (Results of Tests-Raincoat) |
9000.0 |
|
| 19 (Water Absorption Test at RT) |
1000.0 |
|
| 20 (Result of the Tests (Foam Material) Attached Annexure) |
6000.0 |
|
| 21 (Results of the Tests (SMC profile) Annexure attached) |
21500.0 |
|
| 22 (Result of the Tests (UPVC profile) Attached Annexure) |
16500.0 |
|
| 23 (Thickness, mm) |
1000.0 |
|
| 24 (Density at RT) |
1000.0 |
|
| 25 (Hardness Test - Shore A
(Normal Condition)) |
1000.0 |
|
| 26 (Hardness Test - Shore A
(After ageing Condition)) |
2000.0 |
|
| 27 (Results of the Test-Buckram (Annexure attached)) |
31500.0 |
|
| 28 (Accelerated Fading test (After72hours exposure)) |
5000.0 |
|
| 29 (Thickness, mm) |
3000.0 |
|
| 30 (Count) |
1000.0 |
|
| 31 (Fiber Composition) |
2000.0 |
|
| 32 (Results of the Tests (Annexure attached Dungricloth)) |
11000.0 |
|
| 33 (Scouring loss, %) |
1200.0 |
|
| 34 (pH value of aqueous extract (cold method)) |
1200.0 |
|
| 35 (Tensile Strength, MPa) |
2000.0 |
|
| 36 (Elongation, %) |
1000.0 |
|
| 37 (Tensile Strength, MPa & Elongation, %) |
2000.0 |
|
| 38 (Results of Test (Pl. see Annexure attached)) |
12500.0 |
|
| 39 (Results of Tests (Annexure Attached AF5200)) |
15000.0 |
|
| 40 (Softening point) |
2000.0 |
|
| 41 (Thickness test) |
1000.0 |
|
| 42 (Elongation, % at 23deg Both Longitudinal & Transverse direction) |
1000.0 |
|
| 43 (Joint Strength, N/5cm width, in Longitudinal & Transverse direction) |
2000.0 |
|
| 44 (Tear Strength, N in Longitudinal & Transverse direction) |
2000.0 |
|
| 45 (Cold Flexibility at (-)2degC) |
2000.0 |
|
| 46 (Results of the tests(Annexure-Polycarbonate Sheet)) |
9000.0 |
|
| 47 (Shore Hardness, Shore-A) |
1000.0 |
|
| 48 (Identification of Material-FTIR) |
2000.0 |
|
| 49 (Thickness of foam-Seat) |
1000.0 |
|
| 50 (Thickness of Foam-Back) |
1000.0 |
|
| 51 (Density of Foam-Seat) |
1000.0 |
|
| 52 (Density of Foam-Back) |
1000.0 |
|
| 53 (Powder coating thickness) |
2000.0 |
|
| 54 (Thickness of Fabric) |
1000.0 |
|
| 55 (Dimension Seat Size) |
1000.0 |
|
| 56 (Dimension Back size) |
1000.0 |
|
| 57 (UV Exposure (Protection) Test) |
5000.0 |
|
| 58 (Results of tests (Polycarbonate sheet)) |
4000.0 |
|
| 59 (Test Results of Tiffin Carrier Bag) |
8000.0 |
|
| 60 (Material of Zip Runner) |
1200.0 |
|
| 61 (Test results of Tiffin Carrier Bag - Dimensions & Visuals) |
2000.0 |
|
| 62 (Density) |
1000.0 |
|
| 63 (Tensile Strength) |
2000.0 |
|
| 64 (Compressibility(%)) |
1000.0 |
|
| 65 (Recovery (%)) |
1000.0 |
|
|
| 2720 |
National Test House (SR), Chennai
| IS 3203 (1982) - Methods of testing local thickness of electroplated coatings (First Revision) |
Methods of testing local thickness of electroplated coatings (First Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| IS 3203 (Coating thickness) |
2000.0 |
|
|
| 2721 |
National Test House (SR), Chennai
| IS 1868 (1996) - Anodic coatings on aluminium and its alloys - Specification (Third Revision) |
Anodic coatings on aluminium and its alloys - Specification (Third Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 9.2 c (Eddy current method) (Thickness of Coating, Micron) |
2000.0 |
|
|
| 2722 |
National Test House (SR), Chennai
| ASTM A240/A240M-15b (2015) - Chromium and Chromium-Nickel Stainless Steel Plate, Sheet, and Strip for Pressure Vessels and for General Applications |
Chromium and Chromium-Nickel Stainless Steel Plate, Sheet, and Strip for Pressure Vessels and for General Applications |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Table 1 (Carbon) |
1000.0 |
|
| Table 1 (Manganese) |
1000.0 |
|
| Table 1 (Phosphorus) |
1000.0 |
|
| Table 1 (Sulphur) |
1000.0 |
|
| Table 1 (Silicon) |
2000.0 |
|
| Table 1 (Chromium) |
1000.0 |
|
| Table 1 (Nickel) |
1000.0 |
|
| Table 1 (Molybdenum) |
1000.0 |
|
|
| 2723 |
National Test House (SR), Chennai
| ASTM A312 (2016) - Standard Specification for Seamless, Welded, and Heavily Cold Worked Austenitic Stainless Steel Pipes |
Standard Specification for Seamless, Welded, and Heavily Cold Worked Austenitic Stainless Steel Pipes |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 7 (Carbon) |
500.0 |
|
| 7 (Manganese) |
500.0 |
|
| 7 (Phosphorus) |
500.0 |
|
| 7 (Sulfur) |
500.0 |
|
| 7 (Silicon) |
500.0 |
|
| 7 (Chromium) |
500.0 |
|
| 7 (Nickel) |
500.0 |
|
| 7 (Molybdenum) |
500.0 |
|
| 9 (Wall Thickness, mm) |
1000.0 |
|
| 10 (Tensile Strength) |
1000.0 |
|
| 10 (Yield Strength) |
1000.0 |
|
| 10 (Elongation) |
1000.0 |
|
| 9.1 (Outside diameter, mm) |
1000.0 |
|
| 9.1 (Mass per meter, kg/m) |
1000.0 |
|
|
| 2724 |
National Test House (ER), Kolkata
| IS:14772-2000 (2000) - GE~NERAL REQUIREMENTS FOR ENCLOSURES FOR ACCESSORIES FOR HOUSEHOLD AND SIMILAR
FIXED ELECTRICAL INSTALLATIONS - SPECIFICATION |
GE~NERAL REQUIREMENTS FOR ENCLOSURES FOR ACCESSORIES FOR HOUSEHOLD AND SIMILAR
FIXED ELECTRICAL INSTALLATIONS - SPECIFICATION |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 15 (RESISTANCE OF INSULATING MATERIAL TO ABNORMAL HEAT AND TO FIRE) |
10000.0 |
|
|
| 2725 |
National Test House (SR), Chennai
| Manufacture/Customer Specification - Test as per Manufacturer/Customer Specification |
Test as per Manufacturer/Customer Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Test as per Manufacture / Customer Specification) |
25000.0 |
|
| 2 (Electrical conductivity test in IACS as per IS 613.) |
5000.0 |
|
| 3 (Electrical Resistance Test as per IS 3635.) |
3000.0 |
|
| 4 (Purity of Copper as per IS 191) |
2000.0 |
|
| 5 (Tensile and Elongation test for Insulation and Outer Sheath on the lines of IS 694.) |
3000.0 |
|
| 6 (Test for over all Dimension) |
1000.0 |
|
| 7 (Density) |
1000.0 |
|
| 8 (Electrical Resistivity Test IS 1897 in accordance with IS 3635.) |
1500.0 |
|
| 9 (CHEMICAL COMPOSITION as per IS 440) |
3000.0 |
|
| 10 (Uniformity of Zinc coating) |
1500.0 |
|
| 11 (Marking of Sample) |
1.0 |
|
| 12 (Dimensions as per Table 1 & 2 of IEC 62561-2) |
1000.0 |
|
| 13 (Electrical Resistivity - Table 2 & 4 of IEC 62561-2) |
2000.0 |
|
| 14 (Tensile Strength as per Cl.No:5.2.5 of IEC 62561-2 :2012) |
1500.0 |
|
| 15 (Coating Test as per Cl.No:5.2.2 of IEC 62561-2 :2012) |
2000.0 |
|
| 16 (Testing as per UL 94 Classification Requirement (V-0), Vertical Flame Test and Customer Test request.) |
5000.0 |
|
| 17 (LSZH Property) |
20000.0 |
|
| 19 (Mechanical Endurance test for 1000 cycles on the lines of relevant para of IEC 62271-103:2011) |
15000.0 |
|
| 20 (Electrical Resistivity Test as per IEC 62561-7) |
10000.0 |
|
| 21 (Determination of Insulation Resistance as per IS 10810: Part 43: 1984 (Reaffirmed Year: 2021 )) |
1500.0 |
|
| 22 (Thermal profile test – as per PGCIL Specification Cl. No 2.6) |
15000.0 |
|
| 23 (Magnetic power loss test as per PGCIL technical Specification Cl 2.5.) |
15000.0 |
|
| 24 (Drawing Verification) |
6000.0 |
|
| 25 (Functional Verification of Fail Safe Circuits in Heavy Escalator) |
20000.0 |
|
| 24 (Drawing Verification) |
6000.0 |
|
| 26 (Mechanical endurance test for 1000 Cycles on lines of relevant para of IEC 62271-102) |
15000.0 |
|
| 27 (Test as per RDSO Specification:T1/ SPC/OHE/CAT(CuCd)/0971 Effect from 04.01.2021 for Individual wire & Conductor (Values Specified / Declared by Power Grid)) |
64700.0 |
|
| 28 (Test as per RDSO Specification:T1/ SPC / OHE/ CW /0971 Effect from 01.01.2021 (Values Specified / Declared by Power Grid)) |
15000.0 |
|
| 29 (Type Test as per RDSO spec No. IRS : S76-89) |
25000.0 |
|
| 37 Note Authenticator Cum Sorting Machines (3+1) (Note Authenticator Cum Sorting Machines (3+1)
Tests and observations as per Bank Specification) |
40000.0 |
|
| 31 (onsite : Scientist charges) |
5000.0 |
|
| 32 (Lightning Impulse Voltage Dry Test) |
15000.0 |
|
| 33 Note Authenticator Cum Sorting Machines (2+1) (Note Authenticator Cum Sorting Machines (2+1)
Tests and observations as per Bank Specification) |
40000.0 |
|
| 34 Note Authenticator Cum Sorting Machines (4+1) (Note Authenticator Cum Sorting Machines (4+1)
Tests and observations as per Bank Specification) |
50000.0 |
|
| 35 Note Authenticator Cum Sorting Machines (8+1) (Note Authenticator Cum Sorting Machines (8+1)
Tests and observations as per Bank Specification) |
50000.0 |
|
| 36 (Scientist Charges ( for 2 persons, 5 days)) |
50000.0 |
|
| 30 Note Authenticator Cum Sorting Machines (1+1) (Note Authenticator Cum Sorting Machines (1+1) Tests and observations as per Bank Specification) |
35000.0 |
|
| 1 (Test as per Manufacture / Customer Specification) |
25000.0 |
|
| 38 (Manufacture/Customer Specification - Test as per Manufacturer/Customer Specification) |
3000.0 |
|
| 39 (Tests as per Manufacture/Customer Specification) |
5000.0 |
|
| 40 (Tests as per Manufacture/Customer Specification) |
10000.0 |
|
| 41 (Tests as per Manufacture/Customer Specification) |
15000.0 |
|
| 42 (Tests as per Manufacture/Customer Specification) |
20000.0 |
|
| 43 (Conformity Tests for Battery operated platform truck as per IS:10311-1982) |
30000.0 |
|
| 44 (Manufacture/Customer Specification) |
40000.0 |
|
| 47 (Manufacture/Customer Specification) |
100000.0 |
|
| 48 (Manufacture/Customer Specification) |
200000.0 |
|
|
| 2726 |
National Test House (ER), Kolkata
| IS 2250:1981 - Code of Practice for Preparation and use of Masonry Mortars |
Code of Practice for Preparation and use of Masonry Mortars |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 2.4,6.1, Table 1 & Appendix A (Compressive strength of Masonry Mortar) |
4000.0 |
|
| 9.1.1 Table 1,Appendix B (Consistency of Masonry Mortar) |
500.0 |
|
| 6,Table 1 (Grade of Mortar-Mortar mix ratio (IS 1199)) |
5000.0 |
|
|
| 2727 |
National Test House (WR), Mumbai
| ISO / EN / ASTM - Custom Specn Adhesive / Coating NTH(WR) |
Custom Specn Adhesive / Coating NTH(WR) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 9 (Pull out test of coating, (ISO 4624), N/mm^2) |
5000.0 |
|
| 8 (Pull-off Adhesion Strength of Coating on Concrete (on the lines of ASTM D 7234-12), MPa) |
5000.0 |
|
| 8 (Average Tensile Strength (on the lines of ASTM D 412), N/mm^2) |
2000.0 |
|
| 8 (Average Elongation at Break (on the lines of ASTM D 412), in %) |
2000.0 |
|
| 5 (Depth of Permeability of Water under pressure (on lines of BS EN 12390), in mm) |
10000.0 |
|
| 5 (Depth of Permeability of Water under pressure-comparison with controlled specimen (on lines of BS EN 12390), in mm) |
15000.0 |
|
|
| 2728 |
National Test House (ER), Kolkata
| ND Custom 3 (2022) - Stainless Steel Wire 420 Grade |
Stainless Steel Wire 420 Grade |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Tensile Strength) |
3000.0 |
|
| 2 (Carbon) |
500.0 |
|
| 2 (Manganese) |
500.0 |
|
| 2 (Silicon) |
500.0 |
|
| 2 (Phosphorus) |
500.0 |
|
| 2 (Sulphur) |
500.0 |
|
| 2 (Chromium) |
500.0 |
|
| 2 (Nickel) |
500.0 |
|
|
| 2729 |
National Test House (ER), Kolkata
| Custom BHU Soil |
- |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (pH) |
1000.0 |
|
| 2 (Manganese) |
1000.0 |
|
| 3 (Zinc) |
1000.0 |
|
| 4 (Total Nitrogen) |
1000.0 |
|
| 5 (Iron) |
1000.0 |
|
|
| 2730 |
National Test House (ER), Kolkata
| IS 1148 (2009) - Steel Rivet Bars (medium And High Tensile)--For Structural Purposes--For Structural Purposes |
Steel Rivet Bars (medium And High Tensile)--For Structural Purposes--For Structural Purposes |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 13 (Shear Test (Medium Tensile Steel)) |
3000.0 |
|
| 9 (Diameter of Bar (Over 24mm)) |
500.0 |
|
| 6 (Carbon) |
500.0 |
|
| 6 (Sulphur) |
500.0 |
|
| 6 (Phosphorus) |
500.0 |
|
|