| 2311 |
National Test House (WR), Mumbai
| Custom - Berger QUV test - QUV test of Paint and Coating |
QUV test of Paint and Coating |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| A-2 (Salt spry for 96 hrs) |
5000.0 |
|
|
| 2312 |
National Test House (WR), Mumbai
| IS 2086 (1993) - Carriers and Bases in Electrical Fuses for voltages up to 650 V - Specification |
Carriers and Bases in Electrical Fuses for voltages up to 650 V - Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 9 (All possible tests as per customer requirement) |
20000.0 |
|
|
| 2313 |
National Test House (ER), Kolkata
| 2664 - Specification for Quenching Oil |
Specification for Quenching Oil |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 3 (Ash, Percent by mass) |
1000.0 |
|
| 4 (Pour point, Dg C) |
1000.0 |
|
| 6 (Kinematic Viscosity at 40 Dg C, cSt) |
1000.0 |
|
| 7 (Viscosity Index) |
1000.0 |
|
| 8 (Saponification Value) |
1000.0 |
|
| 9 (Volatility (Loss on heating at 150 dg C for two hours)) |
1000.0 |
|
| 11 (Copper strip corrosion test at 100 dg C for 3h) |
1000.0 |
|
|
| 2314 |
National Test House (WR), Mumbai
| IS 9968 : Part 1 (1984) - Elastomer Insulated Cables |
Elastomer Insulated Cables |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 10.2 (Conductor Resistance) |
2000.0 |
|
| 21.1 (Insulation resistance) |
1000.0 |
|
| 22.1 (High voltage (water immersion) test) |
1000.0 |
|
| 22.1 (Flammability test) |
1000.0 |
|
|
| 2315 |
National Test House (WR), Mumbai
| IS 3384 (1986) - bitumen primer for use in waterproofing and damp-proofing |
bitumen primer for use in waterproofing and damp-proofing |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 3.1(v)c (Test on residue from distillation upto 360 dg , c)matter soluble in carbon disulphide or ccl4 or tce) |
1200.0 |
|
| 3.1(v)b (Test on residue from distillation upto 360 dg , b)penetration 25 dg 100g 5 sec) |
1200.0 |
|
| 3.1(v) a (Test on residue from distillation upto 360 dg , a)ductility) |
1200.0 |
|
| 3.1(iv) (water Content ) |
1200.0 |
|
| 3.1(iii) (Flash point pensky martens closed type) |
1200.0 |
|
| ADDITIONAL pARAMETER (Specific gravity) |
1200.0 |
|
|
| 2316 |
National Test House (SR), Chennai
| IS 14862:2000 - Fibre cement flat sheets-Specification |
Fibre cement flat sheets-Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5.1 (Dimensional and Geometrical Characteristics) |
2000.0 |
|
| 5.2.1 (Mechanical and Physical Characteristics-Bending strength) |
4000.0 |
|
| 5.2.2 (Mechanical and Physical Characteristics-Apparent density) |
1000.0 |
|
| 6.1 (Type characteristics-Bending strength) |
8000.0 |
|
| 6.2 (Type characteristics-Water impermeability) |
4000.0 |
|
| 6.3 (Type characteristics-Frost Resistance) |
25000.0 |
|
| 6.4 (Type characteristics-Warm water) |
25000.0 |
|
| 6.6 (Type characteristics- Heat rain test) |
100000.0 |
|
| 6.5 (Type characteristics-soak- dry test) |
25000.0 |
|
|
| 2317 |
National Test House (NR), Ghaziabad
| IRC 137-2022 (2022) - Guideline on use of Fibre-reinforced polymer bars in road projects |
Guideline on use of Fibre-reinforced polymer bars in road projects |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 11.2.5.1 (Mean measured cross sectional area ASTM D7205) |
1000.0 |
|
| 4.1 (Guaranteed Ultimate tensile strength, ASTM D 7205) |
3000.0 |
|
| 0 (Mean Tensile Modulus of Elasticity, ASTM D 7205) |
2000.0 |
|
| 4.1 (Mean Ultimate Tensile Strain, ASTM D 7205) |
3000.0 |
|
| 0 (Guuaranteed Transeverse Shear Strength, ASTM D 7617) |
5000.0 |
|
| 0 (Guuaranteed Bond Strength, ASTM D 7913) |
10000.0 |
|
| 0 (Mean moisture Absorption to Saturation, ASTM D570) |
1000.0 |
|
|
| 2318 |
National Test House (NWR), Jaipur
| IS 2250:1981 - Code of Practice for Preparation and use of Masonry Mortars |
Code of Practice for Preparation and use of Masonry Mortars |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6,Table 1 (Grade of Mortar-Mortar mix ratio (IS 1199)) |
5000.0 |
|
| Custom ( ref 5.1.4) (Sulphate content) |
1200.0 |
|
| Custom (Chloride content) |
1200.0 |
|
|
| 2319 |
National Test House (NWR), Jaipur
| IS 17425 (2020) - Irrigation Equipment - Quick Coupled Polyethylene Pipes and Fittings for Sprinkler Irrigation Systems - Specification |
Irrigation Equipment - Quick Coupled Polyethylene Pipes and Fittings for Sprinkler Irrigation Systems - Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 7.1.2 (IS:17425 & Annex-A(Acceptance test)) |
5000.0 |
|
| 7.1.1 (IS:17425 (Visual Appearance)) |
500.0 |
|
| 6.2.1 (IS:2530 (C.B.C)) |
2000.0 |
|
| 4.1.4 (IS:2530 (CBD)) |
1000.0 |
|
| 7.1.3 (IS:17425 (Reversion)) |
1000.0 |
|
| 5.1.2 (IS:17425 (Ovality)) |
500.0 |
|
| 7.1.4 (IS:17425 & Annex-D (Tensile Strength)) |
2000.0 |
|
| 7.1.4 (IS:17425 & Annex-D (Elongation at Break)) |
2000.0 |
|
| 7.1.7 (IS:2530 (MFR)) |
2000.0 |
|
| 7.1.6 (IS:7328 (Density)) |
2000.0 |
|
| 7.1.2 (IS:17425 & Annex-A) (Quality test)) |
5000.0 |
|
| 5.1.1 (IS:17425 (OD)) |
500.0 |
|
| 5.1.1 (IS:17425 (Wall thickness)) |
500.0 |
|
| 7.2.1 (IS:17425 (Leakage Test)) |
5000.0 |
|
|
| 2320 |
National Test House (ER), Kolkata
| EN 438 (2016) - High Pressure decorative laminates(HPL) - Sheets based on thermosetting resins(Usually called laminates)-Part-3 : classification and Specifications for laminates less than 2 mm thick intended for bonding to supporting substrates. |
High Pressure decorative laminates(HPL) - Sheets based on thermosetting resins(Usually called laminates)-Part-3 : classification and Specifications for laminates less than 2 mm thick intended for bonding to supporting substrates. |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6.2.5 (Visual Inspection) |
500.0 |
|
| 6.2.5.3 (Edge Quality) |
500.0 |
|
| 6.3 (Thickness) |
1000.0 |
|
| 6.3 (Edges Straightness) |
1000.0 |
|
| 6.3 (Length) |
500.0 |
|
| 6.3 (Width) |
500.0 |
|
| 6.3 (Edges Squareness) |
1000.0 |
|
| 6.3 (Flatness) |
1000.0 |
|
| 6.4 (Resistance to Surface Wear) |
5000.0 |
|
| 6.4 (Resistance to immersion in boiling water) |
2000.0 |
|
| 6.4 (Resistance to Water Vapour) |
2000.0 |
|
| 6.4 (Resistance to dry heat(160 deg.C)) |
2000.0 |
|
| 6.4 (Dimensional stability at elevated temperature) |
2000.0 |
|
| 6.4 (Resistance to wet heat(100 deg.C)) |
2000.0 |
|
| 6.4 (Resistance to cracking under stress) |
2000.0 |
|
| 6.4 (Resistance to scratching) |
2000.0 |
|
| 6.4 (Resistance to staining) |
5000.0 |
|
| 6.4 (Light Fastness(Xenon arc)) |
3000.0 |
|
| 6.4 (Density) |
1000.0 |
|
|
| 2321 |
National Test House (NR), Ghaziabad
| Cable tray - Cable tray |
Cable tray |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Dimension Tests) |
1000.0 |
|
| 2 (Thickness Test) |
1000.0 |
|
| 3 (Perforation area) |
1000.0 |
|
| 4 (Galvanization Thickness Test) |
2000.0 |
|
| 5 (Load Test with applying 1.7 times SWL) |
3000.0 |
|
| 6 (Material Composition Test) |
3000.0 |
|
| 2 (Salt Spray Test, 24 hours) |
960.0 |
|
|
| 2322 |
National Test House (NR), Ghaziabad
| Junction Box - Junction Box |
Junction Box |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Dimensional Tests) |
1000.0 |
|
| 2 (Thickness Test) |
1000.0 |
|
| 3 (Mass of Zinc Coating) |
2000.0 |
|
| 4 (Vertical Load Test) |
3000.0 |
|
|
| 2323 |
National Test House (NR), Ghaziabad
| Race Way - Race Way |
Race Way |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 0 (Dimensional Tests) |
1000.0 |
|
| 1 (Thickness Test) |
1000.0 |
|
| 2 (Mass of Zinc Coating) |
2000.0 |
|
| 3 (Material Composition Test) |
3000.0 |
|
| 4 (Vertical Load Test) |
3000.0 |
|
|
| 2324 |
National Test House (SR), Chennai
| IS 16714:2018 - Ground Granulated Blast Furnace Slag for Use in Cement, Mortar and Concrete |
Ground Granulated Blast Furnace Slag for Use in Cement, Mortar and Concrete |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5.1 Table 1 (Chemical Requirements of GGBS) |
5000.0 |
|
| 5.2 (Moisture content of GGBS) |
1000.0 |
|
| 6,Table 2 (Physical requirements) |
5000.0 |
|
|
| 2325 |
National Test House (NWR), Jaipur
| IS 1161 (2014) - Steel tubes for structural purposes - Specification (Fifth Revision) |
Steel tubes for structural purposes - Specification (Fifth Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 11.3.1 (Cold Bend Test up to 50 mm NB) |
1000.0 |
|
| 11.3.2 (Flattening Test above 50 mm NB) |
1000.0 |
|
| 11.2 (Percentage Elongation, %) |
1000.0 |
|
| 11.2 (Yield Strength, MPa) |
1000.0 |
|
| 11.2 (Tensile Strength, MPa) |
1000.0 |
|
| 6 (Dimension) |
1000.0 |
|
| 6 (Mass per meter, kg/m) |
1000.0 |
|
| 8 (Coating thickness, micron) |
2000.0 |
|
| 5 (Chemical Composition) |
2500.0 |
|
| 0 (Mass of Zinc Coating) |
2000.0 |
|
|
| 2326 |
National Test House (ER), Kolkata
| CUSTOM-23-ER-MCALI - Calibration of Ultrasonic Thickness Gauge |
Calibration of Ultrasonic Thickness Gauge |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Length) |
1200.0 |
|
|
| 2327 |
National Test House (ER), Kolkata
| CUSTOM-22-ER-MCALI - Calibration of Wheel Gauge (B.G) for thick and wear adopter profile |
Calibration of Wheel Gauge (B.G) for thick and wear adopter profile |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Length) |
1200.0 |
|
|
| 2328 |
National Test House (ER), Kolkata
| CUSTOM-21-ER-MCALI - Calibration of Wheel Diameter Gauge |
Calibration of Wheel Diameter Gauge |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Length) |
1200.0 |
|
|
| 2329 |
National Test House (ER), Kolkata
| CUSTOM-20-ER-MCALI - Calibration of Buffer Height Gauge |
Calibration of Buffer Height Gauge |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Length) |
1200.0 |
|
|
| 2330 |
National Test House (ER), Kolkata
| CUSTOM-19-ER-MCALI - Calibration of WHEEL DISTANCE GAUGE |
Calibration of WHEEL DISTANCE GAUGE |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Length) |
1200.0 |
|
|
| 2331 |
National Test House (ER), Kolkata
| CUSTOM - WOODEN SAWDUST BRIQUETTE |
WOODEN SAWDUST BRIQUETTE |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (ASH CONTENT) |
1000.0 |
|
| 2 (GROSS CALORIFIC VALUE) |
2000.0 |
|
| 3 (Moisture) |
1000.0 |
|
|
| 2332 |
National Test House (ER), Kolkata
| CUSTOM-18-ER-MCALI - Calibration of BORE GAUGE |
Calibration of BORE GAUGE |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 0 (Length) |
1200.0 |
|
| 1 (Length) |
3000.0 |
|
|
| 2333 |
National Test House (ER), Kolkata
| CUSTOM-17-ER-MCALI - Calibration of COUNTER LIMIT GAUGE NO.2 |
Calibration of COUNTER LIMIT GAUGE NO.2 |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Length) |
1200.0 |
|
|
| 2334 |
National Test House (ER), Kolkata
| CUSTOM-16-ER-MCALI - Calibration of COUNTER LIMIT GAUGE NO.1 |
Calibration of COUNTER LIMIT GAUGE NO.1 |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Length) |
1200.0 |
|
|
| 2335 |
National Test House (ER), Kolkata
| CUSTOM-15-ER-MCALI - Calibration of KNOCKLE NOSE WEAR STRETCH LIMIT GAUGE |
Calibration of KNOCKLE NOSE WEAR STRETCH LIMIT GAUGE |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Length) |
1200.0 |
|
|
| 2336 |
National Test House (ER), Kolkata
| CUSTOM-14-ER-MCALI - Calibration of MECHANICAL DIAL FLANGE WEAR GAUGE FOR BG LOCO |
Calibration of MECHANICAL DIAL FLANGE WEAR GAUGE FOR BG LOCO |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Length) |
1200.0 |
|
|
| 2337 |
National Test House (ER), Kolkata
| CUSTOM-13-ER-MCALI - Calibration of MECHANICAL DIAL ROOT WEAR GAUGE FOR BG LOCO |
Calibration of MECHANICAL DIAL ROOT WEAR GAUGE FOR BG LOCO |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Dimension) |
1200.0 |
|
|
| 2338 |
National Test House (NR), Ghaziabad
| 781 (1984) - SPECIFICATION FOR CAST COPPER ALLOY SCREW DOWN BIB TAPS AND STOP VALVES FOR WATER SERVICES |
SPECIFICATION FOR CAST COPPER ALLOY SCREW DOWN BIB TAPS AND STOP VALVES FOR WATER SERVICES |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5 (Dimension, mm) |
2000.0 |
|
| 4 (Chemical Composition) |
5000.0 |
|
| 0 (Measurement of Weight) |
1000.0 |
|
| 0 (Hydrostatic Test of Body) |
5000.0 |
|
|
| 2339 |
National Test House (NWR), Jaipur
| IS 2046 NR CIVIL (1995 Reaffirmed 2005) - Decorative Thermosetting Synthetic Resin Bonded Laminated Sheets |
Decorative Thermosetting Synthetic Resin Bonded Laminated Sheets |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5.5 & 5.3 (Dimensions-Length, Width, Thickness, Wraping (Flatness), Reverse Side Bonding) |
4000.0 |
|
| 5.5 (Resistance to Immersion in Boiling Water (Mass increase, Thickness increase, Appearance)) |
3500.0 |
|
| 5.5 (Resistance to Steam) |
2000.0 |
|
| 5.5 (Resistance to Cracking) |
2000.0 |
|
|
| 2340 |
National Test House (ER), Kolkata
| CUSTOM - CAST IRON |
CAST IRON |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Cadmium) |
1200.0 |
|
| 2 (Lead) |
1200.0 |
|
| 3 (Mercury) |
1200.0 |
|
| 4 (Chromium) |
1200.0 |
|
| 5 (Carbon) |
500.0 |
|
| 6 (Manganese) |
500.0 |
|
| 7 (Silicon) |
1500.0 |
|
| 5 (Carbon) |
500.0 |
|
| 6 (Manganese) |
500.0 |
|
| 7 (Silicon) |
1500.0 |
|
| 5 (Carbon) |
500.0 |
|
| 6 (Manganese) |
500.0 |
|
| 7 (Silicon) |
1500.0 |
|
| 5 (Carbon) |
500.0 |
|
| 6 (Manganese) |
500.0 |
|
|