| 181 |
National Test House (ER), Kolkata
| #IS 6003 - Indented Wire for Prestressed Concrete |
Indented Wire for Prestressed Concrete |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Cl 5.1 (Dimensions) |
1000.0 |
|
| Cl 5.2 (Geometric consideration) |
1000.0 |
|
| Cl 7.1 (Tensile test) |
3000.0 |
|
| Cl 8.5 (Reverse bend test) |
1500.0 |
|
| Cl 4 (Chemical analysis) |
1000.0 |
|
|
| 182 |
National Test House (ER), Kolkata
| #IS 6006 - Uncoated Stress Relieved Strand for prestressed concrete |
Uncoated Stress Relieved Strand for prestressed concrete |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Cl 4.5 (Workmanship and finish) |
1000.0 |
|
| Cl 5 (Dimensions) |
1000.0 |
|
| Cl 8.2 (Tensile test) |
5000.0 |
|
| Cl 4.1.2 (Chemical analysis) |
1000.0 |
|
|
| 183 |
National Test House (ER), Kolkata
| #IS 2721 - Galvanised Chain Link |
Galvanised Chain Link |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Cl.7 (Workmanship) |
1000.0 |
|
| Cl.6 (Dimensions) |
1000.0 |
|
| Cl.9.1.1 (Tensile test) |
3000.0 |
|
| Cl.9.1.2 (Wrapping test) |
1000.0 |
|
| Cl.9.1.3 (Torsion test) |
1000.0 |
|
| Cl.9.2 (Galavanisation) |
3000.0 |
|
| Cl.5 (Chemical analysis) |
2000.0 |
|
|
| 184 |
National Test House (Satellite Centre), Varanasi
| IS 17568 (2021) - THERMAL PAPER SPECIFICATION |
THERMAL PAPER SPECIFICATION |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 4.3 (Grammage) |
1000.0 |
|
| 4.2 (Tensile Index, MD) |
1000.0 |
|
| 4.2 (Tensile Index, CD) |
1000.0 |
|
| 4.2 (Tear Index, MD) |
1000.0 |
|
| 4.2 (Tear Index, CD) |
1000.0 |
|
| 4.2 (Opacity) |
2000.0 |
|
| 4.2 (Brightness ISO) |
2000.0 |
|
| 4.2 (Gloss at 75 deg.) |
1500.0 |
|
| 4.2 (Smoothness (Bendtsen)) |
2000.0 |
|
| 4.2 (Wax Pick) |
2000.0 |
|
|
| 185 |
National Test House (Satellite Centre), Varanasi
| IS 1060 - METHODS OF SAMPLING AND TEST FOR PAPER AND ALLIED PRODUCTS |
METHODS OF SAMPLING AND TEST FOR PAPER AND ALLIED PRODUCTS |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| IS 1060 (Part5/Sec5) (Substance (Grammage)) |
1000.0 |
|
| IS 1060 (Part 5/Sec 3) (Thickness) |
1000.0 |
|
|
| 186 |
National Test House (NER), Guwahati
| 14255:1995 - AERIAL BUNCHED CABLES-FOR WORKING VOLTAGES UPTO AND INCLUDING 11OOVOLTS |
AERIAL BUNCHED CABLES-FOR WORKING VOLTAGES UPTO AND INCLUDING 11OOVOLTS |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Tests (a)Tests on phase/street light conductor: i) Tensile test ii) Resistance test,b)Insulation resistance (Volume resistivity) test for XLPE Conductor,c)Test on messenger conductor: i) Breaking load ii) Elongation test iii)Resistance test,c)Physical tests for XLPE Insulation: i) Tensile strength and elongation at break,ii)Hot Se Test,d)Test for the thickness of insulation,e)High voltage test .) |
8500.0 |
|
|
| 187 |
National Test House (WR), Mumbai
| IS 2250/On the lines of ASTM/IS 1727/2770 - MICRO CONCRETE |
MICRO CONCRETE |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| custom (Flow Test(on the lines of IS 2250)) |
1000.0 |
|
| custom (Compressive strength (on the lines of IS /ASTM)-1 Day) |
2000.0 |
|
| custom (Compressive strength (on the lines of IS /ASTM)-7 Days) |
2000.0 |
|
| custom (Compressive strength (on the lines of IS /ASTM)-28 Days) |
2000.0 |
|
| custom (Flexural strength -(on the lines of IS/ASTM)1 Day) |
2000.0 |
|
| custom (Flexural strength (on the lines of IS /ASTM)-7 Days) |
2000.0 |
|
| custom (Flexural strength (on the lines of IS /ASTM)-28 Days) |
2000.0 |
|
| custom (Drying Shrinkage (IS 1727)) |
1000.0 |
|
| custom (Split Tensile strength (IS 5816)) |
2000.0 |
|
| custom (Scratch Hardness-Mohs' scale(-on the lines of IS 13630(13))) |
1500.0 |
|
| custom (Co-efficient of Thermal Expansion(IS /ASTM)) |
3000.0 |
|
|
| 188 |
National Test House (WR), Mumbai
| IS 2250:1981 - Code of Practice for Preparation and use of Masonry Mortars |
Code of Practice for Preparation and use of Masonry Mortars |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 2.4,6.1, Table 1 & Appendix A (Compressive strength of Masonry Mortar) |
4000.0 |
|
| 9.1.1 Table 1,Appendix B (Consistency of Masonry Mortar) |
500.0 |
|
| 6,Table 1 (Grade of Mortar-Mortar mix ratio (IS 1199)) |
5000.0 |
|
| Custom ( ref 5.1.4) (Sulphate content) |
1200.0 |
|
| Custom (Chloride content) |
1200.0 |
|
| custom (Bulk density-kg/cum:{on the lines of IS 2386(III)}) |
500.0 |
|
| custom (Tensile strength (on the lines of IS 15477)) |
4000.0 |
|
| custom (Pot life (on the lines of IS 5410)) |
1000.0 |
|
|
| 189 |
National Test House (WR), Mumbai
| CSD Samples - CSD Samples : Test as per CSD Data sheet |
CSD Samples : Test as per CSD Data sheet |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Automatic cooker-Tests as per IS: 11879: 1986) |
20000.0 |
|
| 2 (LED Bulb Test as per CSD Data Sheet & IS: 302-1:2008) |
4000.0 |
|
| 3 (Performance / Functional Tests as per relevant IS Specification of IS 4280:1980 (or) CSD Technical data Specification.) |
20000.0 |
|
| 4 (Performance / Functional Tests as per relevant IS 11514 (or) Technical data Specification.) |
7000.0 |
|
| 5 (Performance / Functional Tests as per relevant IS 366 (or) Technical data Specification.) |
10000.0 |
|
| 6 (Test as per IS: 374 -1979, Reaffirmed 2007 (Up to amendment 8)) |
8000.0 |
|
| 7 (All possible Performance / Functional Tests as per relevant IS 302-2-6 : 2009 or IS 2994 (or) Technical data Specification.) |
8000.0 |
|
| 8 (All possible Performance / Functional Tests as per relevant IS 302-2-9 : 2009 (or) Technical data Specification.) |
8000.0 |
|
| 9 (All possible Performance / Functional Tests as per relevant IS 8144 : 1997 (or) Technical data Specification.) |
7000.0 |
|
| 10 (All possible Performance / Functional Tests as per IS 368 (1992): Electric Immersion Water Heaters) |
14000.0 |
|
|
| 190 |
National Test House (WR), Mumbai
| #IS 6003 - Indented Wire for Prestressed Concrete |
Indented Wire for Prestressed Concrete |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Cl 5.1 (Dimensions) |
1000.0 |
|
| Cl 5.2 (Geometric consideration) |
1000.0 |
|
| Cl 7.1 (Tensile test) |
3000.0 |
|
| Cl 8.5 (Reverse bend test) |
1500.0 |
|
| Cl 8.7 (Relaxation Test (Optional)) |
1000.0 |
|
| Cl 4 (Chemical analysis) |
1000.0 |
|
|
| 191 |
National Test House (WR), Mumbai
| #IS 6006 - Uncoated Stress Relieved Strand for prestressed concrete |
Uncoated Stress Relieved Strand for prestressed concrete |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Cl 4.5 (Workmanship and finish) |
1000.0 |
|
| Cl 5 (Dimensions) |
1000.0 |
|
| Cl 8.2 (Tensile test) |
5000.0 |
|
| Cl 8.5 (Relaxation Test) |
1000.0 |
|
| Cl 4.1.2 (Chemical analysis) |
1000.0 |
|
|
| 192 |
National Test House (WR), Mumbai
| #IS 1786 - HSD Bar (28 -32 mm) |
HSD Bar (28 -32 mm) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Cl.3 (Mass per meter run) |
1000.0 |
|
| Cl 9.2 (Tensile test) |
3500.0 |
|
| Cl.9.3 (Bend test) |
1000.0 |
|
| Cl.9.4 (Rebend test) |
1500.0 |
|
| Cl.5.7 (Pull out test (Fee Ratio 70:30 among Mechanical & Civil)) |
15000.0 |
|
| Cl.8 (Rib area) |
1000.0 |
|
| Cl.8 (TS/YS Ratio) |
500.0 |
|
| Cl.5 (Total Elongation at Maximum Force) |
500.0 |
|
| Cl.4.2 (Chemical analysis without CE) |
2000.0 |
|
| Cl.4.2 (HSDS Bar (C, S, P, & S+P, CE)) |
2500.0 |
|
| Cl.4.2 (Chemical Analysis with Micro Alloys without CE) |
4000.0 |
|
| Cl.4.2 (Chemical Analysis with Micro Alloys & CE / Chemical Analysis including CE) |
4500.0 |
|
| Cl 9.1.3 (Phase Distribution - TM Ring test (Optional)) |
3000.0 |
|
|
| 193 |
National Test House (WR), Mumbai
| #IS 1786n - HSD Bar (12 - 28 mm) |
HSD Bar (12 - 28 mm) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Cl.3 (Mass per meter run) |
1000.0 |
|
| Cl.9.2 (Tensile test) |
3000.0 |
|
| Cl.9.3 (Bend test) |
1000.0 |
|
| Cl.9.4 (Pull out test (Fee Ratio 70:30 among Mechanical & Civil)) |
15000.0 |
|
| Cl.5.7 (Rebend test) |
1000.0 |
|
| Cl.5 (Rib area) |
1000.0 |
|
| Cl.4.2 (Chemical analysis without CE) |
2000.0 |
|
| Cl.4.2 (HSDS Bar (C, S, P, & S+P, CE)) |
2500.0 |
|
| Cl.4.2 (Chemical Analysis with Micro Alloys without CE) |
4000.0 |
|
| Cl.4.2 (Chemical Analysis with Micro Alloys & CE / Chemical Analysis including CE) |
4500.0 |
|
| Cl 9.1.3 (Phase Distribution - TM Ring test (Optional)) |
1000.0 |
|
| 4.2 (carbon by mass) |
500.0 |
|
| 4.2 (sulphur) |
500.0 |
|
| 4.2 (Phosphorus) |
500.0 |
|
| 4.2 (Sulphur plus Phosphorus) |
500.0 |
|
| 4.2 (C.E.) |
2000.0 |
|
| Cl.8 () |
500.0 |
|
|
| 194 |
National Test House (WR), Mumbai
| #IS 1786 - HSD Bar (up to 12 mm) |
HSD Bar (up to 12 mm) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Cl.3 (Mass per meter run) |
1000.0 |
|
| Cl.9.2 (Tensile test) |
2000.0 |
|
| Cl.9.3 (Bend test) |
1000.0 |
|
| Cl.9.4 (Rebend test) |
1000.0 |
|
| Cl.5.7 (Pull out test (Fee Ratio 70:30 among Mechanical & Civil)) |
10000.0 |
|
| Cl.8 (TS/YS Ratio) |
500.0 |
|
| Cl.8 (Total Elongation at Maximum Force) |
500.0 |
|
| Cl.5 (Rib area) |
1000.0 |
|
| Cl.4.2 (Chemical analysis without CE) |
2000.0 |
|
| Cl.4.2 (HSDS Bar (C, S, P, & S+P, CE)) |
2500.0 |
|
| Cl.4.2 (Chemical Analysis with Micro Alloys without CE) |
4000.0 |
|
| Cl 9.1.3 (Phase Distribution - TM Ring test (Optional)) |
3000.0 |
|
|
| 195 |
National Test House (WR), Mumbai
| NTH/WI/MC (On the lines of DKD-R 6-1:01/2014) 8 - Calibration of Pressure Gauges |
Calibration of Pressure Gauges |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1.1 (Industrial pressure gauge calibration) |
1200.0 |
|
|
| 196 |
National Test House (SR), Chennai
| # IS 14276 (2016) - Cement bonded particle borad -Full test |
Cement bonded particle borad -Full test |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 7.1 , 7.3, & 10.2 (Dimension-Length) |
500.0 |
|
| 7.1 , 7.3, & 10.2 (Dimension-Width) |
500.0 |
|
| 7.2 , 7.3, & 10.2 (Dimension-Thickness) |
500.0 |
|
| 7.3 10.2 (Squareness) |
500.0 |
|
| 7.3 10.2 (Edge straightness) |
500.0 |
|
| 8.1 & 10.3 (Density) |
500.0 |
|
| 8.2 & 10.3 (Moisture content) |
1000.0 |
|
| 8.3 & 10.5 (Water absorption (2 & 24 h soaking)) |
1000.0 |
|
| 8.5 (Workability) |
1000.0 |
|
| 10.7 Table 1 (Modulus of Rupture & Elasticity (Dry condition)) |
2500.0 |
|
| 10.8 Table 1 (Modulus of Rupture & Elasticity (Wet condition)) |
2500.0 |
|
| 10.9 Table 1 (Tensile Strength perpendicular to surface (Dry)) |
2000.0 |
|
| 10.9 Table 1 (Tensile Strength perpendicular to surface(accelerated ageing)) |
2000.0 |
|
| 10.10 Table 1 (Screw withdrawl strength (face&edge)) |
1500.0 |
|
| 9.2.j (pH value) |
1000.0 |
|
| 8.4,10.6 (Swelling in water (2 h soaking)) |
1000.0 |
|
|
| 197 |
National Test House (ER), Kolkata
| # IS 15965 - AZ Coated Sheet |
AZ Coated Sheet |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Cl 8.3.1 (Bend test) |
1000.0 |
|
| Cl 11 (Dimensions) |
1000.0 |
|
| Cl 5 (Mass of AZ coating) |
2000.0 |
|
| Cl 11 (Total coated thickness (As per test request)) |
1000.0 |
|
| Cl 11 (Base Metal Thickness (As per test request)) |
1000.0 |
|
| Cl 6.1 (Tensile test) |
3000.0 |
|
| Cl 5 (Chemical composition) |
2000.0 |
|
| Cl 8.5 (Scratch Hardness) |
2000.0 |
|
| Cl 8.4 (Pensile Hardness) |
2000.0 |
|
| Cl 8.3 (Adhesion Test) |
2000.0 |
|
| Cl 7 (Paint Coating test) |
1000.0 |
|
| Cl 9.1 (Freedom from Defects) |
1000.0 |
|
|
| 198 |
National Test House (ER), Kolkata
| #IS 16172 - Reinforcement Couplers for Mechanical Splices of Bars in Concrete (28-32mm) |
Reinforcement Couplers for Mechanical Splices of Bars in Concrete (28-32mm) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Cl 7 (Workmanship and Finish) |
1000.0 |
|
| Cl 8 (Dimension) |
1000.0 |
|
| Cl 9.2 (Tensile test) |
4000.0 |
|
| Cl 9.2 (Location of Failure) |
1000.0 |
|
| Cl 9.2 (Tenslie testing of TMT(Optional)) |
4000.0 |
|
|
| 199 |
National Test House (ER), Kolkata
| #IS 16172 - Reinforcement Couplers for Mechanical Splices of Bars in Concrete (12-28mm) |
Reinforcement Couplers for Mechanical Splices of Bars in Concrete (12-28mm) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Cl 7 (Workmanship and Finish) |
1000.0 |
|
| Cl 8 (Dimension) |
1000.0 |
|
| Cl 9.2 (Tensile test) |
3500.0 |
|
| Cl 9.2 (Location of Failure) |
1000.0 |
|
| Cl 9.2 (Percentage Elongation) |
1000.0 |
|
| Cl 9.2 (Tenslie testing of TMT(Optional)) |
3500.0 |
|
|
| 200 |
National Test House (ER), Kolkata
| #IS 16172 - Reinforcement Couplers for Mechanical Splices of Bars in Concrete (0-12mm) |
Reinforcement Couplers for Mechanical Splices of Bars in Concrete (0-12mm) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Cl 7 (Workmanship and Finish) |
1000.0 |
|
| Cl 8 (Dimension) |
1000.0 |
|
| Cl 9.2 (Tensile test) |
3000.0 |
|
| Cl 9.2 (Location of Failure) |
1000.0 |
|
| Cl 9.2 (Percentage Elongation) |
1000.0 |
|
| Cl 9.2 (Tenslie testing of TMT(Optional)) |
3000.0 |
|
|
| 201 |
National Test House (ER), Kolkata
| # IS 738 - WROUGHTALUMINIUM AND ITS ALLOYS DRAWN TUBES FOR GENERAL ENGINEERING PURPOSES |
WROUGHTALUMINIUM AND ITS ALLOYS DRAWN TUBES FOR GENERAL ENGINEERING PURPOSES |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Cl 6 (Freedom form defects) |
1000.0 |
|
| Cl 7 (Dimensions(Including straightness)) |
2000.0 |
|
| Cl 9.1.1 (Tensile test) |
3000.0 |
|
| Cl 9.1.2 (Flattening Test) |
1000.0 |
|
| Cl 5 (Chemical analysis) |
5500.0 |
|
|
| 202 |
National Test House (ER), Kolkata
| # IS 733 - ALUMINIUM ALLOY BARS, RODS AND SECTIONS |
ALUMINIUM ALLOY BARS, RODS AND SECTIONS |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Cl 5 (Freedom form defects) |
1000.0 |
|
| Cl 9 (Dimensions(Including straightness)) |
2000.0 |
|
| Cl 7 (Tensile test) |
3000.0 |
|
| Cl 5 (Chemical analysis) |
5500.0 |
|
|
| 203 |
National Test House (ER), Kolkata
| #IS 1285 - Aluminum Sections |
Aluminum Sections |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Cl 6 (Freedom form defects) |
1000.0 |
|
| Cl 8 (Dimensions (Including straightness)) |
2500.0 |
|
| Cl 10 (Tensile test) |
3000.0 |
|
| Cl 9 (Chemical analysis) |
5000.0 |
|
|
| 204 |
National Test House (ER), Kolkata
| # IS 6649 - Washer/DTI Washer |
Washer/DTI Washer |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Cl 3 (Dimensions) |
1500.0 |
|
| Cl 8 (Finish) |
1000.0 |
|
| Cl 8 (Zn coating Test) |
2000.0 |
|
| Cl 8 (Uniformity of Coating) |
1000.0 |
|
| Cl 7 (Hardness test) |
2000.0 |
|
| Cl 5 (Cheimcal Test) |
2000.0 |
|
|
| 205 |
National Test House (ER), Kolkata
| # IS 5986 - W Beam & C Post |
W Beam & C Post |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| - (Chemical composition) |
3500.0 |
|
| Cl 8.3 (Yield strength) |
1000.0 |
|
| Cl 8.3 (Tensile strength) |
1000.0 |
|
| Cl 8.3 (% Elongation) |
1000.0 |
|
| Cl 16 (Weight per meter) |
1000.0 |
|
| Cl 13 (Freedom from defect) |
1000.0 |
|
| Cl 9 (Bend Test) |
1000.0 |
|
| - (Mass of Zinc Coating) |
2000.0 |
|
| - (Uniformity of Coating) |
1000.0 |
|
| Cl 15 (Dimensions) |
1000.0 |
|
|
| 206 |
National Test House (NER), Guwahati
| #IS 1489(1 & 2 ) (2015) - Cement-PPC full test |
Cement-PPC full test |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
| 207 |
National Test House (SR), Chennai
| IS 456-II (2000) - Plain and Reinforced Concrete - CONCRETE CHEMICAL [Custom] |
Plain and Reinforced Concrete - CONCRETE CHEMICAL |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
| 208 |
National Test House (SR), Chennai
| # IS 456 (2000) - CONSTRUCTION WATER |
CONSTRUCTION WATER |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5.4.1.3 (Setting time of water sample) |
2000.0 |
|
| 5.4.1.2 (Compressive strength of water sample) |
4000.0 |
|
| 5 (To neutralize 100 ml sample of water, using phenolphthalein as an indicator, it should not require more than 5 ml of 0.02 normal NaOH.) |
750.0 |
|
| 5 (To neutralize 100 ml sample of water, using mixed indicator, it should not require more than 25 ml of 0.02 normal H,SO 4') |
1000.0 |
|
| 5.4.2 (PH) |
1000.0 |
|
| 5.4 (Organic Solids) |
700.0 |
|
| 5.4 (Inorganic Solids) |
600.0 |
|
| 5.4 (Suspended matter) |
600.0 |
|
|
| 209 |
National Test House (NR), Ghaziabad
| 1077 (2025) - Common Burnt Clay Building Bricks |
Common Burnt Clay Building Bricks |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6.1 (Dimensions) |
1000.0 |
|
| 7.1 (Compressive Strength,) |
2000.0 |
|
| 7.2 (Water Absorption) |
1000.0 |
|
| 7.3 (Efflorescence) |
1000.0 |
|
|
| 210 |
National Test House (NR), Ghaziabad
| NTH_CUSTOM/2026/026 - CUSTOM NR HV- PROBE TYPE HEAT DETECTOR |
CUSTOM NR HV- PROBE TYPE HEAT DETECTOR |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| customer requirement (Perfomance Test) |
15000.0 |
|
|