| 1771 |
National Test House (NR), Ghaziabad
| ETI/OHE/50(6/97) re-designated to TI/SPC/OHE/CAT(Cu-Cd)/0971 (2021) - Technical specification for Cadmium copper conductors for over head Electric Traction |
Technical specification for Cadmium copper conductors for over head Electric Traction |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 8.2.1 (Visual examination) |
1000.0 |
|
| 8.2.2 (Chemical composition) |
2000.0 |
|
| 8.2.3 (Measurement of diameter of individual wire and stranded conductor) |
2000.0 |
|
| 8.2.4 (Measurement of weight of wire and conductor) |
2000.0 |
|
| 8.2.5 (Measurement of lay length and lay ratio of each layer of stranded conductor) |
5000.0 |
|
| 8.2.6 (Measurement of Electrical resistance of wire and stranded conductor) |
15000.0 |
|
| 8.2.7 (Tensile test on wires) |
32000.0 |
|
| 8.2.8 (Wrapping test on wires) |
5000.0 |
|
|
| 1772 |
National Test House (NR), Ghaziabad
| ETI/OHE/76(6/97) - Technical specification for Hard Drawn Grooved Contact wire for Electric traction |
Technical specification for Hard Drawn Grooved Contact wire for Electric traction |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 4.1 (Chemical Composition) |
6000.0 |
|
| 8.5.1 (Visual Examination) |
1000.0 |
|
| 8.5.2 (Measurement of Dimensions) |
2000.0 |
|
| 8.5.3 (Compression Test) |
3000.0 |
|
| 8.5.4 (Tensile Strength) |
2000.0 |
|
| 8.5.4 (Elongation Test) |
1000.0 |
|
| 8.5.6 (Micro-structure Examination) |
3000.0 |
|
| 9.5.8 (Bending Test) |
1000.0 |
|
| 9.5.6 (Brinell Hardness Test) |
1.0 |
|
| 9.5.10 (Electrical Resistance Test) |
2000.0 |
|
| 9.5.5 (Measurement of Weight) |
1000.0 |
|
|
| 1773 |
National Test House (NWR), Jaipur
| IS 16651 (2017) - High Strength Deformed Stainless Steel Bars and Wires for Concrete Reinforcement - Specification |
High Strength Deformed Stainless Steel Bars and Wires for Concrete Reinforcement - Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6.3 (Mass per meter run.) |
1000.0 |
|
| 9.2 (0.2 percent proof stress) |
500.0 |
|
| 9.2 (Tensile Strength (dia of the bar 12-28 mm)) |
1500.0 |
|
| 9.3 (Bend Test) |
1000.0 |
|
| 9.4 (Re Bend Test) |
1000.0 |
|
| 9.2 (Percentage Elongation after Fracture.) |
500.0 |
|
| 4.3.1 (4) (Carbon (as C)) |
500.0 |
|
| 4.3.1 (11) (Phosphorus (as P)) |
500.0 |
|
| 4.3.1 (7) (Sulphur (as S)) |
500.0 |
|
| 4.3.1 (5) (Silicon (as Si)) |
500.0 |
|
| 4.3.1 (6) (Manganese (as Mn)) |
500.0 |
|
| 4.3.1 (8) (Chromium (as Cr)) |
500.0 |
|
| 4.3.1 (9) (Nickel (as Ni)) |
500.0 |
|
|
| 1774 |
National Test House (ER), Kolkata
| MoRTH Section 500 (2013) - Bituminous Bases and Surface Coarses - Bituminous Pavement Layers |
Bituminous Bases and Surface Coarses - Bituminous Pavement Layers |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 504 (Bituminous Macadam Mix Design on the lines of MoRTH Section 504.) |
35000.0 |
|
| 510 (Mix Design for open graded premix on lines of MoRTH / IRC) |
35000.0 |
|
| 505 (Mix Design for Dense Bituminous Macadam on lines of MoRTH) |
35000.0 |
|
|
| 1775 |
National Test House (WR), Mumbai
| - - GG-P-455B |
GG-P-455B |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| - (Abrasion Resistance) |
3000.0 |
|
| - (Acid Corrosion) |
1500.0 |
|
| - (Heat Resistance) |
2000.0 |
|
| - (Stain Resistance) |
1500.0 |
|
| - (Cleaning resistance (Any one media)) |
1500.0 |
|
| - (Low Temperature Resistance) |
5000.0 |
|
| - (Organic Solvent Resistance (any one solvent)) |
2000.0 |
|
| - (Salt Spray Corrosion Test) |
30000.0 |
|
| - (Accelerated Light & Weather Resistance test) |
24000.0 |
|
| - (Chemical composition of sheet) |
5000.0 |
|
|
| 1776 |
National Test House (NR), Ghaziabad
| TI/SPC/OHE/CAT (Cu-Mg)/0150 (2016) - Hard drawn stranded Magnesium Copper Conductors |
Hard drawn stranded Magnesium Copper Conductors |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5.1 (Copper Content, % by Mass) |
1000.0 |
|
| 5.1 (Magnesium Content, % by Mass) |
1000.0 |
|
| 5.1 (Chemical composition, % by Mass) |
5000.0 |
|
| 12.2 (Diameter, mm) |
1000.0 |
|
| Weight per Kilometre (Weight per Kilometre, kg) |
1000.0 |
|
| 12.2 (Resistance per km at 20 deg. C) |
2000.0 |
|
| 12.2 (Breaking load of individual wire) |
19000.0 |
|
| 12.2 (Tensile strength of wire) |
3000.0 |
|
| 0 (Lay length and Lay ratio) |
1000.0 |
|
| 0 (Wrapping test) |
1000.0 |
|
|
| 1777 |
National Test House (ER), Kolkata
| IS 15853 (2009) - Textiles – Polyester blended woven suiting for uniforms |
Textiles – Polyester blended woven suiting for uniforms |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 4.1 (Threads/dm (Weft)) |
2000.0 |
|
| 4.1 (Breaking Strength on 5 cm x 20 cm (Weft)) |
2000.0 |
|
| 4.1 (Colour fastness to washing) |
4000.0 |
|
| 4.1 (Breaking Strength on 5 cm x 20 cm strip (Warp)) |
2000.0 |
|
| 4.1 (Blend Composition) |
2000.0 |
|
| 4.1 (Mass) |
2000.0 |
|
| 4.1 (Threads/dm (Warp)) |
2000.0 |
|
|
| 1778 |
National Test House (ER), Kolkata
| 44 - IRON OXIDE PIGMENTS FOR PAINTS — SPECIFICATION |
IRON OXIDE PIGMENTS FOR PAINTS — SPECIFICATION |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5.3 (Volatile matter, percent by mass,) |
1200.0 |
|
| 5.3 (Residue on sieve, percent by mass,) |
1200.0 |
|
| 5.3 (Matter soluble in water, percent by mass,) |
1200.0 |
|
| 5.3 (Sum of water soluble chloride and sulphate expressed as Cl and SO4,
percent by mass,) |
1200.0 |
|
| 5.3 (Acidity ( as H2SO4 ) or alkalinity ( as NaOH ), percent by mass,) |
1200.0 |
|
| 5.3 (pH of aqueous extract) |
1200.0 |
|
| 5.3 (Total iron ( as Fe2O3 ), percent by mass,) |
1200.0 |
|
| 5.3 (Manganese content ( as MnO2 ), percent by mass,) |
1200.0 |
|
| 5.3 (Loss on ignition, percent by mass,) |
1200.0 |
|
|
| 1779 |
National Test House (ER), Kolkata
| IS 101 Part 5 Sec 2 -1988 - IS 101-5-2 (1988): Methods of sampling and test for paints, varnishes and related products, Part 5: Mechanical test on paint films, Section 2: Flexibility and adhesion |
IS 101-5-2 (1988): Methods of sampling and test for paints, varnishes and related products, Part 5: Mechanical test on paint films, Section 2: Flexibility and adhesion |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| A1 (Mechanical test on paint films-Flexibility and adhesion (Scratch test)) |
3000.0 |
|
|
| 1780 |
National Test House (ER), Kolkata
| IS 9000 Part 8 1981 RA 2021 - Basic environmental testing procedures for electronic and electrical items, Part 8: Vibration |
Basic environmental testing procedures for electronic and electrical items, Part 8: Vibration |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| A.1 (Basic environmental testing-Vibration) |
15000.0 |
|
|
| 1781 |
National Test House (ER), Kolkata
| CPWD--Specification for Flood light Fitting - CPWD--Specification for Flood light Fitting |
CPWD--Specification for Flood light Fitting |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| A.1 (Insulation Resistance (IS 10322 Part 5 Sec 5: 2013)) |
2000.0 |
|
| A.2 (Electric Strength (IS 10322 Part 5 Sec 5: 2013)) |
3000.0 |
|
| A.3 (Resistance to ingress of solid particle (IS 10322: Part 5: Sec 5: 2013)) |
6000.0 |
|
| A.4 (Resistance to Ingress of water (Moisture) (S 10322: Part 5: Sec 5: 2013)) |
6000.0 |
|
| A.5 (Endurance Test and Thermal test ((IS 10322: Part 5: Sec 5: 2013)) |
5500.0 |
|
| A.6 (Moisture (Humidity) Resistance Test (IS 16103 : Part 1 : 2012)) |
2000.0 |
|
| A.7 (Insulation Resistance after Moisture Resistance test (IS 16103: Part 1: 2012)) |
2000.0 |
|
| A.8 (Electrical Parameters – Input power, Current, Voltage, and power factor (IS 16106; 2012)) |
4000.0 |
|
| A.9 (Electrical Parameters – Output Current, output Voltage, and Total Circuit Power (IS 16104; 2012)) |
3000.0 |
|
| A.10 (Surge Test up to 10kV (IEC 61000-4-5)) |
10000.0 |
|
| A.11 (High Voltage Test ( IS 15885-Part 1: 2011)) |
3000.0 |
|
| A.12 (Drop Test (Mechanical Impact Test –IK08 as per IS 17050-2023)) |
1.0 |
|
| A.13 (Vibration (Sinusoidal) Test along 3 axis (IS 9000: Part 8: 1981)) |
15000.0 |
|
| A.14 (Scratch Test (L 3 of IS 101 Part 5 Sec 2)) |
1500.0 |
|
| A.16 (Photometry Test (IS 10322: Part 5: Sec 5: 2013)) |
10000.0 |
|
|
| 1782 |
National Test House (WR), Mumbai
| 15388 (2003) - Silica Fume Specification (Custom requirements) |
Silica Fume Specification (Custom requirements) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 4, Table 1(i) (Silica SiO2 (IS 1727), percent by mass) |
2000.0 |
|
| 4, Table 1(ii) (Moisture Content, percent by mass) |
800.0 |
|
| 4, Table 1(iii) (Loss on ignition (IS 1727), percent by mass) |
1000.0 |
|
| 4, Table 1(iv) (Alkalies as Na2O, (IS 4032), percent) |
1000.0 |
|
| 5, Table 2(ii) (Oversize particle retained on 45 micron IS sieve (IS 1727), percent) |
1000.0 |
|
| 5, Table 2(iv) (Compressive Strength at 7 days as per cent of control sample (IS 1727), %) |
3000.0 |
|
| - - (Bulk Density [IS 2386 (Part 3)], g/cc) |
1000.0 |
|
| - - (Specific Gravity [IS 2386(Part 3)]) |
1000.0 |
|
| 56 (Ferric Oxide [IS 1727 ], %) |
1000.0 |
|
| 5.7 of IS 1727 (Alumina [IS 1727 ], %) |
1000.0 |
|
| 5.8 (Calcium Oxide [IS 1727 ], %) |
1000.0 |
|
| 5.9 (Magnesia [IS 1727], %) |
1000.0 |
|
| 5.10 (Sulphuric Anhydride [IS 1727], %) |
1000.0 |
|
| 2.4 (Particle size [Sieve Analysis (IS 2386 Part 1)], Percentage passing.) |
2000.0 |
|
|
| 1783 |
National Test House (ER), Kolkata
| IS 7369 (1983) - Specification for wheels and castors (First Revision) |
Specification for wheels and castors (First Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 3.0 (Dimensions of Wheel) |
2000.0 |
|
| 3.0 (Identification of material) |
3000.0 |
|
| 6.0 (Load test) |
5000.0 |
|
|
| 1784 |
National Test House (NR), Ghaziabad
| IS 13498- 2017 (2017) - BATHING BAR SPECIFICATION (for NR) |
BATHING BAR SPECIFICATION (for NR) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Clauses 5.1, 7.3 and 8.1, Table 1 (Please see the annexure.) |
10000.0 |
|
|
| 1785 |
National Test House (NR), Ghaziabad
| IS 7884 (2023) - Shampoo - Specification |
Shampoo - Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| CL-3.4, Table 1 (Please see Annexure.) |
8000.0 |
|
|
| 1786 |
National Test House (NR), Ghaziabad
| IS 13114 (1991) - forged brass gate, globe and check valves for water works purposes |
forged brass gate, globe and check valves for water works purposes |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 7 (Dimensions) |
1000.0 |
|
| 9.2 (Materials) |
2000.0 |
|
| 9.3 (Shell Test (Hydrostatic Test)) |
2500.0 |
|
| 9.3 (Seat & Backseat Test (Hydrostatic Test)) |
2500.0 |
|
|
| 1787 |
National Test House (NR), Ghaziabad
| IS 13095 (2020) - Butterfly Valves for General Purposes ( First Revision ) |
Butterfly Valves for General Purposes ( First Revision ) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 10 (Face to Face Dimensions) |
1000.0 |
|
| 17.2 (Hydrostatic Test of Body) |
2500.0 |
|
| 17.3 (Hydrostatic Test of Seat) |
2500.0 |
|
| 15 (Materials) |
2000.0 |
|
| 17.4 (Hydrostatic Test of Disc Strength) |
2500.0 |
|
| 17.1 (Performance Test) |
5000.0 |
|
|
| 1788 |
National Test House (NWR), Jaipur
| CUSTOM-PI for IS 8042 (2015) - Performance Improver for white cement |
Performance Improver for white cement |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 4.1 (a) of IS 8042 (CaO + MgO, %) |
3000.0 |
|
| 4.1 (b) of IS 8042 (Whiteness, %) |
1000.0 |
|
|
| 1789 |
National Test House (NER), Guwahati
| IS:16353-2015 -CLINKER - PORTLAND CEMENT CLINKER |
PORTLAND CEMENT CLINKER |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Table 1 Cl 5 (Ratio of percentage of lime to percentages of silica, alumina and iron oxide) |
1000.0 |
|
| Table 1 Cl 5 (Ratio of percentage of Alumina to that of Iron Oxide) |
1000.0 |
|
| Table 1 Cl 5 (Total sulphur content calculated as sulphuric anhydride (SO3)) |
500.0 |
|
| Table 1 Cl 5 (Free lime, percent by mass,) |
1500.0 |
|
| Table 1 Cl 5 (Chloride content, percent by mass,) |
200.0 |
|
| Table 1 Cl 5 (Magnesia (as MgO), percent by mass) |
1500.0 |
|
| Table 1 Cl 5 (Insoluble residue, percent by mass) |
500.0 |
|
| Table 1 Cl 5 (Total loss on ignition , Percent by mass) |
500.0 |
|
| Table 1 Cl 5 (Alkali content (as Na2O), percent by mass) |
500.0 |
|
|
| 1790 |
National Test House (ER), Kolkata
| Custom/Shoe (2023) - Custom/Shoe |
Custom/Shoe |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1.0 (Tensile Strength) |
- |
|
| 2.0 (Elongation at break) |
- |
|
| 3.0 (Compression Set) |
- |
|
| 4.0 (Hardness, IRHD) |
- |
|
| 5.0 (Ross Flex Test) |
2000.0 |
|
|
| 1791 |
National Test House (SR), Chennai
| CSD Standard for Agarbatti (2023) - Agarbatti sample with CSD Index |
Agarbatti sample with CSD Index |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Dimension, inches) |
1000.0 |
|
| 2 (Colour) |
1000.0 |
|
| 3 (Visual inspection) |
1000.0 |
|
| 4 (Uniformity of coating) |
1000.0 |
|
| 5 (Fragrance) |
1000.0 |
|
| 6 (Size of the stick) |
1000.0 |
|
| 7 (Burning quality) |
1000.0 |
|
| 8 (Burning time, minutes) |
1000.0 |
|
|
| 1792 |
National Test House (ER), Kolkata
| Customer Specification NTH ER Electrical Alipore - Customer Specification NTH ER Electrical Alipore |
Customer Specification NTH ER Electrical Alipore |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Customer Specification NTH ER Electrical Alipore) |
5000.0 |
|
| 2 (Customer Specification NTH ER Electrical Alipore) |
10000.0 |
|
| 3 (Customer Specification NTH ER Electrical Alipore) |
15000.0 |
|
| 4 (Customer Specification NTH ER Electrical Alipore) |
20000.0 |
|
| 5 (Customer Specification NTH ER Electrical Alipore) |
25000.0 |
|
| 6 (Customer Specification NTH ER Electrical Alipore) |
30000.0 |
|
| 7 (Customer Specification NTH ER Electrical Alipore) |
35000.0 |
|
| 8 (Customer Specification NTH ER Electrical Alipore) |
40000.0 |
|
| 9 (Customer Specification NTH ER Electrical Alipore) |
45000.0 |
|
| 10 (Customer Specification NTH ER Electrical Alipore) |
50000.0 |
|
| 11 (Customer Specification NTH ER Electrical Alipore - Customer Specification NTH ER Electrical Alipore) |
55000.0 |
|
| 12 (Customer Specification NTH ER Electrical Alipore - Customer Specification NTH ER Electrical Alipore) |
60000.0 |
|
| 13 (Customer Specification NTH ER Electrical Alipore - Customer Specification NTH ER Electrical Alipore) |
65000.0 |
|
| 14 (Customer Specification NTH ER Electrical Alipore - Customer Specification NTH ER Electrical Alipore) |
70000.0 |
|
| 15 (Customer Specification NTH ER Electrical Alipore - Customer Specification NTH ER Electrical Alipore) |
75000.0 |
|
| 16 (Customer Specification NTH ER Electrical Alipore - Customer Specification NTH ER Electrical Alipore) |
80000.0 |
|
| 17 (Customer Specification NTH ER Electrical Alipore - Customer Specification NTH ER Electrical Alipore) |
85000.0 |
|
| 18 (Customer Specification NTH ER Electrical Alipore - Customer Specification NTH ER Electrical Alipore) |
90000.0 |
|
| 19 (Customer Specification NTH ER Electrical Alipore - Customer Specification NTH ER Electrical Alipore) |
95000.0 |
|
| 20 (Customer Specification NTH ER Electrical Alipore - Customer Specification NTH ER Electrical Alipore) |
100000.0 |
|
| 21 (Customer Specification NTH ER Electrical Alipore) |
110000.0 |
|
| 22 (Customer Specification NTH ER Electrical Alipore) |
120000.0 |
|
| 23 (Customer Specification NTH ER Electrical Alipore) |
130000.0 |
|
| 24 (Customer Specification NTH ER Electrical Alipore) |
140000.0 |
|
| 25 (Customer Specification NTH ER Electrical Alipore) |
150000.0 |
|
| 26 (Customer Specification NTH ER Electrical Alipore) |
160000.0 |
|
| 27 (Customer Specification NTH ER Electrical Alipore) |
170000.0 |
|
| 28 (Customer Specification NTH ER Electrical Alipore) |
180000.0 |
|
| 29 (Customer Specification NTH ER Electrical Alipore) |
190000.0 |
|
| 30 (Customer Specification NTH ER Electrical Alipore) |
200000.0 |
|
|
| 1793 |
National Test House (ER), Kolkata
| FCO 1985 NANO FERTILISER - The Fertiliser (Inorganic, Organic or Mixed) (Control) Order 1985 (As amended up to October 2024) |
The Fertiliser (Inorganic, Organic or Mixed) (Control) Order 1985 (As amended up to October 2024) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Schedule VII Clause 20 D(1) (As per Annexure (Attached)-NON NABL) |
7500.0 |
|
|
| 1794 |
National Test House (ER), Kolkata
| CUSTOM-31-ER-MCALI - Calibration of Inductive Probe |
Calibration of Inductive Probe |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Length) |
3000.0 |
|
|
| 1795 |
National Test House (ER), Kolkata
| CUSTOM-30-ER-MCALI - Calibration of Rudder Template |
Calibration of Rudder Template |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Angle) |
5000.0 |
|
|
| 1796 |
National Test House (NER), Guwahati
| FCO 1985 NANO FERTILISER - The Fertiliser (Inorganic, Organic or Mixed) (Control) Order 1985 (As amended up to October 2024) |
The Fertiliser (Inorganic, Organic or Mixed) (Control) Order 1985 (As amended up to October 2024) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
| 1797 |
National Test House (NR), Ghaziabad
| IS 1065 : Part 1 (2019) - Stable bleaching powder - Specification: Part 1 household and industrial use (Third Revision) |
Stable bleaching powder - Specification: Part 1 household and industrial use (Third Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5.3 (Available Chlorine) |
2500.0 |
|
|
| 1798 |
National Test House (WR), Mumbai
| Customer Specified - Specification |
Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
| 1799 |
National Test House (NER), Guwahati
| 1489_1 (BIS _NTH_NER) (2015) - Portland Pozzolana Cement - Specification: Part 1 Fly Ash Based |
Portland Pozzolana Cement - Specification: Part 1 Fly Ash Based |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6 Table 1_1 (Insoluble residue (IS 4032 : 1985), percent by mass) |
1000.0 |
|
| 6 Table 1_2 (Magnesia (IS 4032: 1985), Percent by mass) |
600.0 |
|
| 6 Table 1_3 (Total Sulphur Content calculated as sulphuric anhydride (SO3) ( IS 4032:1985), percent by mass) |
800.0 |
|
| 6 Table 1_4 (Loss on Ignition (IS 4032 : 1985), percent by mass) |
800.0 |
|
| 6 Table 1_5 (Chloride Content (IS 4032 : 1985), percent by mass) |
800.0 |
|
| 6 Table 1_6 (Alkali content (IS 4032: 1985), percent by mass) |
1000.0 |
|
| 7 Table 2_1 (Fineness [ IS 4031 (Part 2):1999], m^2/kg) |
750.0 |
|
| 7 Table 2_2 (Soundness by Le-Chatelier method [IS 4031 (Part 3):1988], in mm) |
500.0 |
|
| 7 Table 2_2 (Soundness by Autoclave method [IS 4031 (Part 3):1988], in percent) |
1000.0 |
|
| 7 Table 2_3 (Setting Time, Initial [IS 4031 (Part 5) : 1988], in minutes) |
250.0 |
|
| 7 Table 2_3 (Setting Time, Final [IS 4031 (Part 5) : 1988], in minutes) |
250.0 |
|
| 7 Table 2_4 (Compressive Strength - 3 days (72 +/-1 hr), [IS 4031 (Part 6): 1988], MPa) |
800.0 |
|
| 7 Table 2_4 (Compressive Strength - 7 days (168 +/-2 hr), [IS 4031 (Part 6): 1988], MPa) |
800.0 |
|
| 7 Table 2_4 (Compressive Strength - 28 days (672 +/-4 hr), [IS 4031 (Part 6): 1988], MPa) |
800.0 |
|
| 7 Table 2_6 (Drying Shrinkage [IS 4031 (Part 10):1988], in percent) |
800.0 |
|
|
| 1800 |
National Test House (WR), Mumbai
| Custom-23-ER-LM - FLEXIBLE COPPER WIRE |
FLEXIBLE COPPER WIRE |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Diameter of Wire) |
1000.0 |
|
| 2 (Thickness of Wire) |
1000.0 |
|
| 3 (Tensile Strength of Wire) |
3000.0 |
|
|