| 61 |
National Test House (SR), Chennai
| # IS 12894 (2002) - Pulverized Fuel Ash Lime Bricks -Full test |
Pulverized Fuel Ash Lime Bricks -Full test |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5.1 (Dimensions) |
1000.0 |
|
| 7.1 (Compressive strength) |
2000.0 |
|
| 7.4 (Water absorption) |
1000.0 |
|
| 7.3 (Efflorescence) |
1000.0 |
|
| 7.2 (Drying shrinkage) |
2000.0 |
|
|
| 62 |
National Test House (SR), Chennai
| # IS 2185 (1984) - Autoclaved cellular(aerated)Concrete blocks |
Autoclaved cellular(aerated)Concrete blocks |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 8.1 (General Observation) |
500.0 |
|
| 8.2 (Dimension) |
500.0 |
|
| 8.3 (Block Density) |
1000.0 |
|
| 8.4 (Compressive strength) |
12000.0 |
|
| 8.6 (Drying shrinkage) |
2000.0 |
|
| 8.5 (Thermal conductivity) |
5000.0 |
|
|
| 63 |
National Test House (SR), Chennai
| # IS 15965 - AZ Coated Sheet |
AZ Coated Sheet |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Cl 11 (Dimensions) |
1000.0 |
|
| Cl 5 (Mass of AZ coating) |
2000.0 |
|
| Cl 11 (Total coated thickness (As per test request)) |
1000.0 |
|
| Cl 11 (Base Metal Thickness (As per test request)) |
1000.0 |
|
| Cl 6.1 (Tensile test) |
3000.0 |
|
| Cl 5 (Chemical composition) |
2000.0 |
|
| Cl 8.3 (Adhesion Test) |
2000.0 |
|
|
| 64 |
National Test House (NWR), Jaipur
| IS 6649 (1985) - Specification for hardened and tempered washers for high strength structural bolts and nuts (First Revision) |
Specification for hardened and tempered washers for high strength structural bolts and nuts (First Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 7 (Hardness Rockwell C/ Vickers) |
2000.0 |
|
| 3 (Sulphur) |
500.0 |
|
| 3 (Phosphorus) |
500.0 |
|
| 3 (Thickness, S) |
500.0 |
|
| 3 (Chemical Composition as per IS 1570 Part-2.) |
500.0 |
|
|
| 65 |
National Test House (NWR), Jaipur
| ASTM F 959M 06 - Standard Specification for Compressible-Washer-Type Tension Indicator for use with structural Fastener |
Standard Specification for Compressible-Washer-Type Tension Indicator for use with structural Fastener |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
| 66 |
National Test House (NR), Ghaziabad
| # IS 6419 - Welding Rods and Bare Electrodes for Gas Sheilded Arc welding of structural steels (For Grades S2,S3,S4,S5) |
Welding Rods and Bare Electrodes for Gas Sheilded Arc welding of structural steels (For Grades S2,S3,S4,S5) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 14.3.3 (14.3.3 (All weld Impact test)) |
3000.0 |
|
| 14.3.2 (14.3.2 : All Weld Metal Mechanical Te - Ultimate Tensile Strength) |
1000.0 |
|
| 14.3.2 (14.3.2: All Weld Metal Mechanical Test - Yeild Strength) |
1000.0 |
|
| 14.3.2 (14.3.2 : All Weld Metal Mechanical Test - Percent Elongation) |
1000.0 |
|
| 14.3.1 (14.3.1 (Preparation of Weld assembly)) |
7000.0 |
|
| 14.2 (14.2 (Radiography Test)) |
1000.0 |
|
| 10.2.3 (10.2.3 (Helix)) |
250.0 |
|
| 10.2.2 (10.2.2 (Cast)) |
250.0 |
|
| 10.2.1 (10.2.1 (Temper)) |
250.0 |
|
| 10.1 (10.1 (Finish)) |
250.0 |
|
| 8.3 (8.3 (Dimension of Coils)) |
250.0 |
|
| 8.2 (8.2 (Dimension of Rims)) |
250.0 |
|
| 8.1 (8.1 (Dimension of Spools)) |
250.0 |
|
| 5 (5 (Diameter of Wire)) |
250.0 |
|
| 6 (6 (Reels of Wire)) |
250.0 |
|
| 7 (7 (Reeling Conditions)) |
250.0 |
|
| 12 (Chemical Composition (09 elements)) |
5000.0 |
|
| 12 (Chemical Composition (11 elements)) |
6500.0 |
|
|
| 67 |
National Test House (SR), Chennai
| # IS 15622 (2017) - Ceramic tiles (for Group BI & BII) -Full test |
Ceramic tiles (for Group BI & BII) -Full test |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Clause 6 (Dimensions Length) |
500.0 |
|
| Clause 6 (Dimensions Width) |
500.0 |
|
| Clause 6 (Dimensions Thickness) |
500.0 |
|
| Clause 6 (Straigthnessof sides) |
500.0 |
|
| Clause 6 (Rectangularity) |
500.0 |
|
| Clause 6 (Surface flatness) |
1000.0 |
|
| Clause 6 (Surface quality) |
1000.0 |
|
| Clause 6 (Water absoption) |
1000.0 |
|
| Clause 6 (Breaking strength) |
2000.0 |
|
| Clause 6 (Modulus of rupture) |
2000.0 |
|
| Clause 6 (Moisture expansion) |
1000.0 |
|
| Clause 6 (Scratch hardness of surface(Moh's)) |
1000.0 |
|
| Clause 6 (Co-efficient of linear thermal expansion) |
2000.0 |
|
| Clause 6 (Impact resistance-Coefficient of restitution) |
1000.0 |
|
| Clause 6 (Crazing resistance) |
1500.0 |
|
| Clause 6 (Resistance to staining of glazed tiles) |
2500.0 |
|
| Clause 6 (Bulk density) |
1000.0 |
|
| Clause 6 (Breaking strength (for size more than 600 x 600mm) |
4000.0 |
|
| Clause 6 (Modulus of rupture (for size more than 600 x 600mm)) |
4000.0 |
|
| Clause 6 (Resistance to staining of glazed tiles) |
2500.0 |
|
|
| 68 |
National Test House (NWR), Jaipur
| # IS 1077 (2025) - Burnt Clay Building Bricks -Full test |
Burnt Clay Building Bricks -Full test |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
| 69 |
National Test House (SR), Chennai
| # IS 9758:1981 (RA 2022) - Flush Valves and fittings for water closets and urinals |
Flush Valves and fittings for water closets and urinals |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| CL 5 (Manufacture & Construction ) |
2000.0 |
|
| CL 6.1 (DISCHARGE CAPACITY) |
3000.0 |
|
| CL 6.2 (Discharge Rate) |
3000.0 |
|
| CL 6.3 (Working Pressure) |
3000.0 |
|
| CL 7.1 (Hydraulic Pressure Test) |
3000.0 |
|
| CL 7.2 (Endurance Test) |
10000.0 |
|
|
| 70 |
National Test House (SR), Chennai
| # IS 8931: 2021. - Copper alloy single taps, combination tap assemblies, stop valves and single lever mixers for water services as per IS 8931: 2021. |
Copper alloy single taps, combination tap assemblies, stop valves and single lever mixers for water services as per IS 8931: 2021. |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| CL 6 (Manufacture, Workmanship & Construction) |
2000.0 |
|
| CL 7 (Dimension) |
3000.0 |
|
| CL 10.2 (Water Tightness Characterstics) |
4000.0 |
|
| CL 10.3 (Pressure Resistance Characterstics) |
4000.0 |
|
| CL 10.4 (Hydraulic Characteristics) |
4000.0 |
|
| CL 10.5 (Mechanical Strength Characterstics) |
4000.0 |
|
| CL 9 (Measurement of Electroplated Thickness (Coulometric Method) for all taps, faucets and other bathroom fittings as per IS IS1068:1993) |
5000.0 |
|
|
| 71 |
National Test House (SR), Chennai
| CUSTOM/TEXTILE/2024 - CUSTOM/TEXTILE/2024 |
CUSTOM/TEXTILE/2024 |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1.0 (Average GSM) |
1000.0 |
|
| 2.0 (Thread per inch (Warp)) |
500.0 |
|
| 3.0 (Threads per inch (Weft)) |
500.0 |
|
| 4.0 (Yarn Count (warp)) |
1000.0 |
|
| 5.0 (Yarn Count (Weft)) |
1000.0 |
|
| 6.0 (Blend Composition %) |
2000.0 |
|
| 7.0 (Colour Fastness to Washing) |
2000.0 |
|
| 8.0 (Type of Weave) |
500.0 |
|
| 9.0 (pH) |
1000.0 |
|
| 10 (Tensile Strength) |
2000.0 |
|
| 1 (Dimensional change / Shrinkage after washing) |
2000.0 |
|
| 2 (Colour fastness to rubbing) |
2000.0 |
|
| 3 (Colour fastness to perspiration) |
2000.0 |
|
| 4 (Pilling Resistance) |
2000.0 |
|
| 5 (Tear Strength) |
2000.0 |
|
| 6 (Seam Strength) |
1000.0 |
|
|
| 72 |
National Test House (SR), Chennai
| # IS 383 (2016) - Coarse and Fine aggregate for Concrete {Coarse aggregate (Crushed/Partially crushed/Uncrushed)from Natural resources} |
Coarse and Fine aggregate for Concrete {Coarse aggregate (Crushed/Partially crushed/Uncrushed)from Natural resources} |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5.2.1 (Dleterious materials & Organic compounds) |
2000.0 |
|
| 5.3 (Combined flakiness & Elongation index) |
3000.0 |
|
| 5.4.1 (Aggregate Crushing Value) |
1500.0 |
|
| 5.4.1 (Ten percent fines value) |
1500.0 |
|
| 5.4.2 (Aggregate Impact value) |
1500.0 |
|
| 5.4.3 (Aggregate abrasion value) |
1500.0 |
|
| 5.5 (Soundness) |
2000.0 |
|
| 5.6 (Alkali aggregate reaction(Chemical/MB method)) |
3000.0 |
|
| 6 (Size and Grading of aggregates) |
2000.0 |
|
| 5.7 & 7.2 (Total alkali content) |
1000.0 |
|
| 5.7 & 7.2 (Total Sulphate content) |
1200.0 |
|
| 5.7 & 7.2 (Water soluble chloride content) |
1200.0 |
|
| 5.7 (Water absorption) |
1000.0 |
|
| 5.7 (Specific Gravity) |
1000.0 |
|
| 7.2 (Bulk density -Loosely packed) |
500.0 |
|
| 7.2 (Bulk density -Compacted) |
500.0 |
|
|
| 73 |
National Test House (ER), Alipore
| IS 398 : Part 5 (1992) - Aluminium conductor for overhead transmission purposes - Specification: Part 5 aluminium conductors - Galvanized steel - Reinforced for extra high voltage (400 KV And Above) (First Revision) |
Aluminium conductor for overhead transmission purposes - Specification: Part 5 aluminium conductors - Galvanized steel - Reinforced for extra high voltage (400 KV And Above) (First Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 13.3 (Measurement of Diameters of Individual Aluminium and Steel Wires) |
1000.0 |
|
| 13.4 (Measurement of Lay Ratio) |
2000.0 |
|
| 13.5.2 (Breaking Load Test on Individual Wires) |
3500.0 |
|
| 13.6 (Ductility Test) |
3500.0 |
|
| 13.7 (Wrapping Test) |
1000.0 |
|
| 13.8 (Resistance Test) |
5000.0 |
|
| 13.9 (Galvanizing Test) |
2000.0 |
|
|
| 74 |
National Test House (ER), Alipore
| IS 398 : Part 4 (1994) - Aluminium conductors for overhead transmission purposes: Part 4 aluminium alloy stranded conductors (Aluminium - Magnesium - Silicon Type) - Specification (Third Revision) |
Aluminium conductors for overhead transmission purposes: Part 4 aluminium alloy stranded conductors (Aluminium - Magnesium - Silicon Type) - Specification (Third Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 12.2 (Breaking load test of individual Aluminium Alloy wire (7 wire construction)) |
1000.0 |
|
| 12.3 (Elongation test of Aluminium Alloy wire(7 wire construction)) |
1000.0 |
|
| 12.4 (Resistance test of Aluminium Alloy wire(7 wire construction)) |
1000.0 |
|
| 12.2 (Breaking load test of individual Aluminium Alloy wire (19 wire construction)) |
2000.0 |
|
| 12.3 (Elongation test of Aluminium Alloy wire(19 wire construction)) |
2000.0 |
|
| 12.4 (Resistance test of Aluminium Alloy wire (19 wire construction)) |
2000.0 |
|
| 7.2.1 (Measurement of diameter of Aluminium Alloy wire(7 wire construction)) |
1000.0 |
|
| 7.2.1 (Measurement of diameter of Aluminium Alloy wire(19 wire construction)) |
2000.0 |
|
| 9.2 (Measurement of lay ratio (7 wire construction)) |
1000.0 |
|
| 9.2(1) (Measurement of lay ratio-Inner layer(19 wire construction)) |
1000.0 |
|
| 9.2(2) (Measurement of lay ratio - Outer layer(19 wire construction)) |
1000.0 |
|
|
| 75 |
National Test House (ER), Alipore
| IS 398 : Part 2 (1996) - Aluminium conductors for overhead transmission purposes - Specification: Part 2 aluminium conuuctors, galvanized steel - Reinforced (Third Revision) |
Aluminium conductors for overhead transmission purposes - Specification: Part 2 aluminium conuuctors, galvanized steel - Reinforced (Third Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 13.8(3) (Measurement of lay ratio-Outermost layer (30 or 54 wire construction)) |
1000.0 |
|
| 13.2 (Measurement of diameter of individual Aluminium wires (7 wire construction)) |
1000.0 |
|
| 13.8 (Measurement of lay ratio(7 wire construction)) |
2000.0 |
|
| 13.3 (Breaking load of individual Aluminium wires (7 wire construction)) |
3500.0 |
|
| 13.4.1 (Ductility test-Torsion test on steel wires (7 Wire construction)) |
3500.0 |
|
| 13.5 (Wrapping test on Aluminium and Steel wires (7 wire construction)) |
1000.0 |
|
| 13.6 (Resistance of Aluminium wire (7 wire construction)) |
5000.0 |
|
| 13.7(1) (Galvanizing test-Mass of zinc coating(7wire construction)) |
2000.0 |
|
| 13.2 (Measurement of diameter of individual Aluminium wires (30 or 54 Wire construction)) |
1000.0 |
|
| 13.8(1) (Measurement of lay ratio - steel core (30 or 54 wire construction)) |
1000.0 |
|
| 13.3 (Breaking load of individual Aluminium wires (30 or 54 Wire construction)) |
1500.0 |
|
| 13.4.1 (Ductility lest-Torsion test on steel wires (30 or 54 Wire construction)) |
1000.0 |
|
| 13.5 (Wrapping test on Aluminium and Steel wires (30 or 54 Wire construction)) |
1000.0 |
|
| 13.6 (Conductor Resistance test (30 or 54 Wire construction)) |
1000.0 |
|
| 13.7(1) (Galvanizing test-Mass of Zing coating(30 or 54 wire construction)) |
1000.0 |
|
| 13.2(1) (Measurement of diameter of individual steel wire(30 or 54 Wire construction)) |
1000.0 |
|
| 13.3(1) (Breaking load of individual steel wires(30 or 54 wire construction)) |
1500.0 |
|
| 13.4.2 (Ductility test-Elongation test on steel wires (7 Wire construction)) |
3500.0 |
|
| 13.7(2) (Galvanizing - Uniformity of Zinc coating test (7 wire construction)) |
2000.0 |
|
| 13.8(2) (Measurement of Lay ratio-Layer immediately beneath the outer most layer(30 or 54 wire construction)) |
1000.0 |
|
| 13.6 (Resistance Test as per Clause 13.6 (Table 1) in Ohms/km) |
3000.0 |
|
| 13.9 (d. c. Resistance test) |
2000.0 |
|
|
| 76 |
National Test House (ER), Alipore
| IS 398 : Part 1 (1996) - Aluminium conductors for overhead transmission purposes - Specification: Part 1 aluminium stranded conductors (Third Revision) |
Aluminium conductors for overhead transmission purposes - Specification: Part 1 aluminium stranded conductors (Third Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 12.2 (Measurement of diameter of Aluminium wire(7 wire construction)) |
1000.0 |
|
| 12.6(2) (Measurement of lay ratio-Outer layer(19 wire construction)) |
1500.0 |
|
| 12.3 (Breaking load test of individual Aluminium(7 wire construction)) |
1000.0 |
|
| 12.4 (Wrapping test of Aluminium wire (7 wire construction)) |
1000.0 |
|
| 12.5 (Resistance test of Aluminium wire(7 wire construction)) |
1000.0 |
|
| 12.6 (Measurement of lay ratio (7 wire construction)) |
1000.0 |
|
| 12.2 (Measurement of diameter of Aluminium wire(19 wire construction)) |
3000.0 |
|
| 12.3 (Breaking load test of individual Aluminium (19 wire construction)) |
3000.0 |
|
| 12.4 (Wrapping test of Aluminium wire(19 wire construction)) |
3000.0 |
|
| 12.5 (Resistance test of Aluminium wire(19 wire construction)) |
3000.0 |
|
| 12.6(1) (Measurement of lay ratio-Inner layer(19 wire construction)) |
1500.0 |
|
| 9 (Construction(7 or 19 wire construction)) |
- |
|
| 11 (Markings (7 or 19 wire construction)) |
- |
|
|
| 77 |
National Test House (SR), Chennai
| IS 4853 (1982) - Recommended practice for radiographic inspection of fusion welded butt joints in steel pipes (First Revision) |
Recommended practice for radiographic inspection of fusion welded butt joints in steel pipes (First Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| IS 4853 (Radiography) |
2000.0 |
|
|
| 78 |
National Test House (ER), Kolkata
| IS 13757-1993 RA 2011 (1993 RA 2011) - Burnt Clay Fly Ash Building Bricks-specification |
Burnt Clay Fly Ash Building Bricks-specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6.0 Dimensions and Tolerances (Length, Width, Height mm) |
1000.0 |
|
| 7.1 Compressive strength (Compressive strength) |
2000.0 |
|
| 7.2 Water Absorption (Water absorption, %) |
1000.0 |
|
| 7.3 Efflorescence (Efflorescence) |
1000.0 |
|
|
| 79 |
National Test House (ER), Alipore
| NTH_CUSTOM/2026/033 - INDIAN RAILWAYS STANDARD SPECIFICATION FOR CLASSIFICATION, TESTING AND ACCEPTANCE CRITERIA OF FILLER WIRES FOR MIG/MAG WELDING |
INDIAN RAILWAYS STANDARD SPECIFICATION FOR CLASSIFICATION, TESTING AND ACCEPTANCE CRITERIA OF FILLER WIRES FOR MIG/MAG WELDING |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6.2.1 A1 (Welding Performance) |
2000.0 |
|
| 6.2.1 A2 (Accelerated Storage Stability Test) |
3000.0 |
|
| 6.2.2 (Copper Coating) |
1000.0 |
|
| 6.2.3 (Cast and Helix) |
1000.0 |
|
| 6.2.4 (Preparation of weld assembly) |
5000.0 |
|
| 6.2.4 (UTS) |
1000.0 |
|
| 6.2.4 (YS) |
1000.0 |
|
| 6.2.4 (% Elongation) |
500.0 |
|
| 6.2.4 (% Reduction in area) |
500.0 |
|
| 6.2.5 (Carbon) |
500.0 |
|
| 6.2.5 (Manganese) |
500.0 |
|
| 6.2.5 (Silicon) |
500.0 |
|
| 6.2.5 (Sulphur) |
500.0 |
|
| 6.2.5 (Phosphorus) |
500.0 |
|
| 6.2.5 (Molybdenum) |
500.0 |
|
| 6.2.5 (Nickel) |
500.0 |
|
| 6.2.5 (Copper) |
500.0 |
|
| 6.2.5 (Chromium) |
500.0 |
|
| 6.2.5 (Vanadium) |
500.0 |
|
| 6.2.6 (Radiography) |
1500.0 |
|
| 6.2.7 (Hydrogen Content) |
5000.0 |
|
| 6.2.8 (Hardness Survey) |
1000.0 |
|
| 6.2.9 (Macro Examination) |
1000.0 |
|
| 6.2.10 (Fillet Weld Test) |
3000.0 |
|
| 6.2.11 (Corrosion resistance test) |
5000.0 |
|
| 6.2.12 (Charpy Impact Test) |
3000.0 |
|
| 8 (Shelf Life) |
1000.0 |
|
|
| 80 |
National Test House (NWR), Jaipur
| 7098 : Part 1 : 2025 - Crosslinked Polyethylene Insulated Thermoplastic Sheathed Cables - Specification - Part 1 For Working Voltages up to and including 1 100 Volts |
Crosslinked Polyethylene Insulated Thermoplastic Sheathed Cables - Specification - Part 1 For Working Voltages up to and including 1 100 Volts |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Type Tests(3.5 Core/4 Core) (Type Tests,Category-01.) |
29500.0 |
|
| Tests(3Core) (Type Tests,Category-01.) |
27500.0 |
|
| Type Test (1 Core) (Type Test,Category-01.) |
20000.0 |
|
|
| 81 |
National Test House (NR), Ghaziabad
| Custom specification NTH WR IS 101 & other paint - Custom specification NTH WR IS 101 & other paint test methods |
Custom specification NTH WR IS 101 & other paint test methods |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Custom specification NTH WR IS 101 & other paint test methods (Please refer the annexure for test results) |
6000.0 |
|
| Custom specification NTH WR IS 101 & other paint test methods (Please refer the annexure for the test result) |
8400.0 |
|
| RDSO (RDSO, Please see the annexure for test) |
3000.0 |
|
| Custom specification NTH WR IS 101 & other paint test methods (Please refer the annexure for the test result) |
12000.0 |
|
| Custom specification NTH WR IS 101 & other paint test methods (Please refer the annexure for the test result) |
18000.0 |
|
| Custom specification NTH WR IS 101 & other paint test methods (Please refer annexure for the test result) |
24000.0 |
|
| Custom specification NTH WR IS 101 & other paint test methods (Please refer annexure for the test result) |
30000.0 |
|
| Custom specification NTH WR IS 101 & other paint test methods (Please refer annexure for the test result) |
32700.0 |
|
| Custom specification NTH WR IS 101 & other paint (Resistance to Alkali (Annex F IS 15489 : 2013)) |
1500.0 |
|
| Custom specification NTH WR IS 101 & other paint (Accelerated Weathering Test: UV Light 340, 700 Hrs, (ASTM G 154), 4 Hrs UV 4 Hrs Condensation) |
42000.0 |
|
| Custom specification NTH WR IS 101 & other paint (Volatile Organic Compounds (VOC)) |
4000.0 |
|
| Custom specification NTH WR IS 101 & other paint (Inter Laboratory Comparison (ILC Sample) : Please referred annexure for the observed values) |
- |
|
| Custom specification NTH WR IS 101 & other paint (Colour (Visual)) |
1200.0 |
|
| Custom specification for paint samples (Identification of Material by FTIR) |
2000.0 |
|
| Custom specification NTH WR IS 101 & other paint (Resistance to Alkali (Annex F IS 15489 : 2013)) |
1500.0 |
|
|
| 82 |
National Test House (ER), Kolkata
| IRSM 46 (2020) - Filler Wire for MIG/MAG Welding |
Filler Wire for MIG/MAG Welding |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| - (Testing of Welding Electrode) |
17000.0 |
|
| - (Chemical Composition) |
3000.0 |
|
|
| 83 |
National Test House (SR), Chennai
| # MORTH-V 406 - Wet mixmacadam sub-base/base |
Wet mixmacadam sub-base/base |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 404.2.1 (Combined Flakiness and Elongation Indices) |
3000.0 |
|
| 404.2.1 (Water absorption) |
1000.0 |
|
| 400-13 (Grading requirement as per table 400-13) |
2000.0 |
|
| 5 (Plasticity index) |
3000.0 |
|
| 404.2.1 (Soundness) |
1000.0 |
|
| 404.2.1 (Los Angeles abrasion value or aggregate impact value) |
1500.0 |
|
| Custom (Grading requirement as per IS 2386 (1)) |
2000.0 |
|
|
| 84 |
National Test House (SR), Chennai
| NTH_CUSTOM/2026/030 - Custom Standard for Textile Fabric |
Custom Standard for Textile Fabric |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Material Identification of base fabric) |
2000.0 |
|
| 2 (Denier of base fabric) |
1000.0 |
|
| 3 (Base Fabric Weight) |
1000.0 |
|
| 4 (Tensile Strength) |
2000.0 |
|
| 5 (Material Identification of inner coating) |
2000.0 |
|
| 6 (Thickness of inner coating) |
1000.0 |
|
| 7 (GSM of inner coating) |
1000.0 |
|
| 8 (Material Identification of outer coating) |
2000.0 |
|
| 9 (Thickness of outer coating) |
1000.0 |
|
| 10 (GSM of outer coating) |
1000.0 |
|
| 11 (GSM of finished fabric) |
1000.0 |
|
|
| 85 |
National Test House (SR), Chennai
| NTH_CUSTOM/2026/031 - Custom Standard for Wool disc for Cleaning rod |
Custom Standard for Wool disc for Cleaning rod |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Density) |
1000.0 |
|
| 2 (Tensile Strength) |
2000.0 |
|
| 3 (Elongation at break) |
1000.0 |
|
| 4 (Moisture content) |
1500.0 |
|
| 5 (Content of non-woolen fibre) |
2000.0 |
|
|
| 86 |
National Test House (SR), Chennai
| # IS 516 (2021) - Hardened concrete methods of test part 1 testing of strength of hardened concrete section 1 compressive,flexucal and split tensile strength (First Revision) |
Hardened concrete methods of test part 1 testing of strength of hardened concrete section 1 compressive,flexucal and split tensile strength (First Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 3 (Concrete -Compressive Strength of CC Cube 1 set) |
1200.0 |
|
|
| 87 |
National Test House (ER), Kolkata
| # IS 14268 - Uncoated Stress Releived Low Relaxation 7 Ply Strand |
Uncoated Stress Releived Low Relaxation 7 Ply Strand |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6 (Dimensions) |
2000.0 |
|
| 4.5 (Workmanship & finish) |
1000.0 |
|
| 6.2 (Tensile test) |
5000.0 |
|
| - (Chemical test) |
1000500.0 |
|
|
| 88 |
National Test House (ER), Kolkata
| #IS 9537 - Conduits for Electrical installations |
Conduits for Electrical installations |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Cl 7 (Dimensions) |
1000.0 |
|
| Cl 7.2 (Checking outer dia) |
1500.0 |
|
| Cl 9.2 (Bend test) |
2000.0 |
|
| Cl 9.2 (Compression test) |
2000.0 |
|
|
| 89 |
National Test House (ER), Kolkata
| #IS 4270 - Steel tubes for Water Wells |
Steel tubes for Water Wells |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Cl 14 (Visual Examination/Workmenship) |
1000.0 |
|
| Cl 7 (Dimensions) |
1000.0 |
|
| Cl 7.3 (Straightness) |
1000.0 |
|
| Cl 6.1 (Tensile test) |
3000.0 |
|
| Cl 6.2 (Bend test /Flattening) |
1000.0 |
|
| Cl 7.1 (Mass Per Meter) |
1000.0 |
|
|
| 90 |
National Test House (WR), Mumbai
| # IS 6012 - Measurement of coating thickness by eddy current method- 05 spots |
Measurement of coating thickness by eddy current method- 05 spots |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6.1 (Measurement of coating thickness by eddy current method- 05 spots) |
2000.0 |
|
|