| 121 |
National Test House (SR), Chennai
| IS 6956 : 2001(Reaffirmed 2022) - Cover paper-Specification |
Cover paper-Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
| 122 |
National Test House (SR), Chennai
| IS 1397 (2020) - Kraft Paper for Packing and Wrapping — Specification ( Third Revision ) |
Kraft Paper for Packing and Wrapping — Specification ( Third Revision ) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5.5 (Burst Index) |
2000.0 |
|
| 5.5 (Tear Index(MD)) |
1000.0 |
|
| 5.5 (Tear Index (CD)) |
1000.0 |
|
| 5.5 (Tensile Index (MD)) |
1000.0 |
|
| 5.5 (Tensile Index(CD)) |
1000.0 |
|
| 5.5 (Cobb Test) |
1000.0 |
|
| 5.4 (Substance) |
1000.0 |
|
| 5.5 (pH) |
1000.0 |
|
| 5.5 (Moisture Content) |
1000.0 |
|
| 5.2 (Finish) |
1000.0 |
|
| 5.5 (Folding Endurance) |
1500.0 |
|
|
| 123 |
National Test House (NWR), Jaipur
| IS 383:2016 - FINE AND COARSE AGGREGATE FOR CONCRETE-SPECIFICATION (All tests for the Coarse aggregates as per IS 2386) |
FINE AND COARSE AGGREGATE FOR CONCRETE-SPECIFICATION (All tests for the Coarse aggregates as per IS 2386) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5.3 (Combined Flakiness and Elongation Index) |
1500.0 |
|
| 5.4.1 (Aggregate Crushing Value) |
1000.0 |
|
| 5.4.1 (Ten Percent fines value) |
1000.0 |
|
| 5.4.2 (Aggregates Impact Value) |
1000.0 |
|
| 5.4.3 (Aggregate Abrasion value) |
1000.0 |
|
| 6 (Size and grading of aggregates-Sieve analysis) |
1500.0 |
|
| 5.2.1 Table 2 (Deleterious materials) |
1500.0 |
|
| 5.3 (Flakiness Index) |
750.0 |
|
| 5.3 (Elongation Index) |
750.0 |
|
| 5.4.1 (Ten Percent fines value) |
1000.0 |
|
| 5.4.2 (Aggregates Impact Value) |
1000.0 |
|
| 5.4.3 (Aggregate abrasion value) |
1000.0 |
|
| 5.7,Table 3 /Custom (Specific gravity) |
500.0 |
|
| custom (Bulk density -Loose weight) |
500.0 |
|
| custom (Bulk density-Rodded or Compacted weight) |
500.0 |
|
| 5.7,Table 3 /Custom (Water absorption, Percent) |
1000.0 |
|
|
| 124 |
National Test House (NWR), Jaipur
| IS 383:2016 - COARSE AND FINE AGGREGATE FOR CONCRETE-SPECIFICATION (All tests for the fine aggregates as per IS 2386) |
COARSE AND FINE AGGREGATE FOR CONCRETE-SPECIFICATION (All tests for the fine aggregates as per IS 2386) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5.7 (Specific gravity) |
500.0 |
|
| 5.7 (Water absorption) |
1000.0 |
|
| 6 (Size and grading of aggregates-Sieve analysis) |
2000.0 |
|
| 7.2 (Bulk density-Compacted) |
500.0 |
|
| 7.2 (Bulk density-Loose) |
500.0 |
|
|
| 125 |
National Test House (WR), Mumbai
| ISO / ASTM / IS - Insulating Coating and Allied Materials |
Insulating Coating and Allied Materials |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 7 (Thermal Conductivity) |
5000.0 |
|
| 9 (Thermal Conductivity) |
5000.0 |
|
| - - (Thickness of DFT) |
2000.0 |
|
| - - (Surface Burning Characteristics for 1 hour) |
2000.0 |
|
| - - (Surface Burning Characteristics for 2 hour) |
4000.0 |
|
|
| 126 |
National Test House (ER), Alipore
| MMDTS 18034 Rev.05 - Technical specification for PU based Wet-on-Wet applicable Exterior Painting System of LHB type coaches |
Technical specification for PU based Wet-on-Wet applicable Exterior Painting System of LHB type coaches |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 3.X (Anti-graffiti Test) |
5000.0 |
|
| 3.VIII (Cyclic Corrosion (ISO-11997-1 Cycle A for 1000 hours)) |
50000.0 |
|
| 3.IX (Distinctness of Image (DOI)) |
10000.0 |
|
|
| 127 |
National Test House (NER), Guwahati
| 398 (Part-4) (1994) - ALUMINIUM CONDUCTORS FOR OVERHEAD TRANSMISSION PURPOSES,
PART 4 ALUMINIUM ALLOY STRANDED CONDUCTORS (ALUMINIUM-MAGNESIUM-SILICON TYPE) |
ALUMINIUM CONDUCTORS FOR OVERHEAD TRANSMISSION PURPOSES,
PART 4 ALUMINIUM ALLOY STRANDED CONDUCTORS (ALUMINIUM-MAGNESIUM-SILICON TYPE) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 3.1.4 (Lay Ratio) |
1000.0 |
|
| 7.1 (Wire Diameter) |
1000.0 |
|
| 12.2.1 (Breaking Load Test of Strand) |
3000.0 |
|
| 12.3 (Elongation Test) |
3000.0 |
|
| 12.4 (Resistance Test) |
2000.0 |
|
|
| 128 |
National Test House (ER), Kolkata
| IS: 1155-2022 (2022) - ATTA SPECIFICATION |
ATTA SPECIFICATION |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 4.4 Table 1 (Moisture, percent by mass) |
2000.0 |
|
|
| 129 |
National Test House (NR), Ghaziabad
| IS 2932 (2013) - Enamel, Synthetic, Exterior : (a) Undercoating (b) Finishing |
Enamel, Synthetic, Exterior : (a) Undercoating (b) Finishing |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Cl no 6 Table 2 (All parameters (Please see the Annexure) NABL) |
8000.0 |
|
| Cl no 6 Table 2 (All parameters (Please see the Annexure) NON NABL) |
1.0 |
|
|
| 130 |
National Test House (WR), Mumbai
| Proficiency Testing - Proficiency Testing [-] |
Proficiency Testing |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| - (Threads per unit Length) |
1000.0 |
|
| - (Force at rupture(Tensile Strength)) |
2000.0 |
|
| - (Mass per unit area) |
1000.0 |
|
|
| 131 |
National Test House (NER), Guwahati
| 14255 (1995) - Aerial Bunched Cables for working
voltages up to and including 1100 Volts-Reaffirmed 2020 specification |
Aerial Bunched Cables for working
voltages up to and including 1100 Volts-Reaffirmed 2020 specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 10.1 sl no 1(b)(i) ,10.2 sl no(c) (Test on messenger conductor Breaking load) |
1000.0 |
|
| 10.1 sl no 1(b)(ii), 10.2 (d) (Test on messenger conductor Elongation test) |
1500.0 |
|
| 10.2 (e) (Conductor resistance test) |
2000.0 |
|
| 10.1 sl no 1(e),10.2(f) (Test for thickness of insulation) |
1500.0 |
|
| 10.1 sl no 1(g),10.2(k) (High Voltage test) |
1500.0 |
|
| 10.1 sl no 1(c)(i),10.2 (g) (Physical test for XLPE insulation Tensile strength and elongation at break) |
1500.0 |
|
| 10.1 sl no 1(c)(iii),10.2(h) (Physical test for XLPE insulation Hot set test) |
2000.0 |
|
| 10.1 sl no 1(f),10.2(j) (Insulation resistance (Volume Resistivity) test) |
1500.0 |
|
|
| 132 |
National Test House (WR), Mumbai
| EPDM RUBBER - EPDM RUBBER |
EPDM RUBBER |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| - (Hardness) |
1000.0 |
|
| - (Specific Gravity) |
1000.0 |
|
| - (i)Colour ii)Odour) |
1000.0 |
|
|
| 133 |
National Test House (SR), Chennai
| IS 16014 (2024) - Mechanically woven, double - Twisted, hexagonal wire mesh gabions, revet mattresses, rock fall netting and other products for civil engineering purposes (Galvanized Steel Wire Or Galvanized Steel Wire With Polymer Coating) - Specification (First Revision) |
Mechanically woven, double - Twisted, hexagonal wire mesh gabions, revet mattresses, rock fall netting and other products for civil engineering purposes (Galvanized Steel Wire Or Galvanized Steel Wire With Polymer Coating) - Specification (First Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6.1 (Tensile Strength of Mesh Wire(Steel)) |
2000.0 |
|
| 6.1 (Elongation of Mesh Wire) |
1000.0 |
|
|
| 134 |
National Test House (WR), Mumbai
| Dollar BiggBoss - Dollar BiggBoss |
Dollar BiggBoss |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| - (As per annexure attached) |
8000.0 |
|
|
| 135 |
National Test House (NR), Ghaziabad
| IS 15801 (2008) - Polypropylene - Random copolymer pipes for hot and cold water supplies - Specification |
Polypropylene - Random copolymer pipes for hot and cold water supplies - Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 8.0 (Visual Appearance) |
1000.0 |
|
| 7.1 (Outside Diameter) |
1000.0 |
|
| 7.2 (Wall Thickness) |
1000.0 |
|
| 9.5 (Density) |
1000.0 |
|
| 9.6 (Melt Flow Rate) |
2000.0 |
|
| 9.3 (Reversion Test) |
2000.0 |
|
| Clause 9.1 (Hydrostatic Pressure Test @R/T for 1 hr.) |
5000.0 |
|
| Clause 9.1 (Hydrostatic Pressure Test at 95°C for 22 hrs.) |
5000.0 |
|
|
| 136 |
National Test House (SR), Chennai
| IS 516 : Part 1 : Sec 1 (2021) - Hardened concrete methods of test part 1 testing of strength of hardened concrete section 1 compressive,flexucal and split tensile strength (First Revision) |
Hardened concrete methods of test part 1 testing of strength of hardened concrete section 1 compressive,flexucal and split tensile strength (First Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 3 (Compressive strength of Concrete, in N/mm^2) |
1200.0 |
|
| 4 (Flexural Strength of Concrete Beam [as per IS 516 (Part 1) : 2021], in N/mm^2) |
4000.0 |
|
| 3 (Compressive strength of Concrete (With Additives), in N/mm^2) |
1200.0 |
|
|
| 137 |
National Test House (SR), Chennai
| ASTM B221M (2007) - Specification for Aluminnium and aluminium alloy extruded bar, rod, wire, profile, tube |
Specification for Aluminnium and aluminium alloy extruded bar, rod, wire, profile, tube |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 15 (Dimension) |
1000.0 |
|
| 8 (Yield Strength (0.2 % offset)) |
1000.0 |
|
| 8 (Tensile Strength) |
1000.0 |
|
| 8 (%Elongation) |
1000.0 |
|
| 8 (Chemical composition) |
5000.0 |
|
|
| 138 |
National Test House (WR), Mumbai
| 516 (2018 and 2020) - Hardened Concrete —Methods of Test Part 5 Non-destructive Testing of Concrete |
Hardened Concrete —Methods of Test Part 5 Non-destructive Testing of Concrete |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6 (Most likely value of Compressive Strength) |
15000.0 |
|
| - - (Scientist Charges 2 Nos 2 days) |
20000.0 |
|
| 2 (Average Value of Pulse Velocity,) |
15000.0 |
|
| 2 (Average Value of Pulse Velocity (additional Spots 10 Nos), km/s) |
20000.0 |
|
| 6 (Most likely value of Compressive Strength (10 spots additional)) |
15000.0 |
|
| Part 5, Section 4, Clause 6 (Rebound Hammer Test-On site) |
15000.0 |
|
| Part 5, Section 1, Clause 2 (Ultrasonic Pulse Velocity Test (additional 5 spots), km/s) |
10000.0 |
|
| Part 5, Section 1, Clause 2 (Ultrasonic Pulse Velocity Test, km/s (for 5 spots)) |
15000.0 |
|
|
| 139 |
National Test House (NER), Guwahati
| IS 9845 (1998) - Determination of overall migration of constituents of plastics materials and articles intended to come in contact with foodstuffs - Method of analysis (Second Revision) |
Determination of overall migration of constituents of plastics materials and articles intended to come in contact with foodstuffs - Method of analysis (Second Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Overall migration in simulant A) |
3000.0 |
|
| 1 (Overall migration in simulant 'B') |
3000.0 |
|
| 1 (Overall migration in simulant 'C1') |
3000.0 |
|
| 1 (Overall migration in simulant 'C2') |
3000.0 |
|
| 1 (Overall migration in simulant 'D') |
3000.0 |
|
| 1 (Overall migration in simulant 'E') |
3000.0 |
|
|
| 140 |
National Test House (NR), Ghaziabad
| IS 10322 : PART 5 : SEC 3 (2012) - Luminaires: Part 5 particular requirements: Sec 3 luminaires for road and street lighting (First Revision) |
Luminaires: Part 5 particular requirements: Sec 3 luminaires for road and street lighting (First Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Tests (Marking,Construction,Provision for Earthing,Insulation Resistance & Electric Strength (HV Test),Protection Against Electric Shock,Ingress Protection (IP Test): IP5X,Resistance to Heat and Fire: Ball Presuure and Glow wire test and Creepage and Clearance Distances.) |
16000.0 |
|
|
| 141 |
National Test House (ER), Kolkata
| Custom - Concrete - Hardened Concrete Physical & Chemical properties. |
Hardened Concrete Physical & Chemical properties. |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| - - (Test for Sulphate content [IS 4032 or relevant specification], %) |
1000.0 |
|
|
| 142 |
National Test House (ER), Kolkata
| FCO -1985 (1985) - The Fertiliser (Control) Order 1985 (as amended upto Oct 2024) |
The Fertiliser (Control) Order 1985 (as amended upto Oct 2024) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Test parameters 7-above (Test Results (as per Annexure/Form L)) |
7000.0 |
|
| Test parameters 4-6 (Test Results (as per Annexure/Form L)) |
4000.0 |
|
| Test parameters 1-3 (Test Results (as per Annexure/Form L)) |
2000.0 |
|
| Custom (7-above) (Test Results (as per Annexure/Form L; Non-NABL)) |
7000.0 |
|
| Custom (4-6) (Test Results (as per Annexure/Form L; Non-NABL)) |
4000.0 |
|
| Custom (1-3) (Test Results (as per Annexure/Form L; Non-NABL)) |
2000.0 |
|
| 0 (Annexure_NABL) |
- |
|
| 0 (Annexure_Non NABL) |
- |
|
|
| 143 |
National Test House (WR), Mumbai
| Custom specification- Purity of Silver (Contact tip) - Custom specification- Purity of Silver (Contact tip). |
Custom specification- Purity of Silver (Contact tip). |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Purity of Silver, percent by mass) |
2000.0 |
|
|
| 144 |
National Test House (ER), Kolkata
| custom specification-ER/Leather/2025 - custom specification-ER/Leather/2025 |
custom specification-ER/Leather/2025 |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Firm's request (Thickness) |
1000.0 |
|
| Firm's request (Width) |
1000.0 |
|
| Firm's request (Tensile Strength) |
1000.0 |
|
| Firm's request (Elongation at Break, %) |
1000.0 |
|
| Firm's request (Tear Strength) |
2000.0 |
|
| Firm's request (Water Absorption) |
1000.0 |
|
|
| 145 |
National Test House (ER), Kolkata
| CUSTOMER SPEC : EIL SOW & SPEC Vol 2 (Civil) F-6A/B - Epoxy-High Build Coating |
Epoxy-High Build Coating |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Clause 6.0 Table-2 (Please see Annexure) |
40000.0 |
|
|
| 146 |
National Test House (ER), Kolkata
| Custom - Grease WD-24-MIsc-2003 (Rev-1) |
Grease WD-24-MIsc-2003 (Rev-1) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 7.2 (Consistency (Penetration at 25 dg C)) |
1000.0 |
|
| 7.3 (Drop point dg C) |
1000.0 |
|
| 7.4 (Moisture) |
1000.0 |
|
|
| 147 |
National Test House (NER), Guwahati
| IS 516 (Part-11) (2020) - Hardened Concrete - Determination of Portland cement Content of Hardened Hydraulic Cement Concrete |
Hardened Concrete - Determination of Portland cement Content of Hardened Hydraulic Cement Concrete |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Clause no.6 (Ratio of Cement : Concrete) |
6000.0 |
|
|
| 148 |
National Test House (NR), Ghaziabad
| IS 3025 - Water/Raw water/Sewage/Drainage |
Water/Raw water/Sewage/Drainage |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Please see the Annexure) |
15000.0 |
|
|
| 149 |
National Test House (ER), Kolkata
| 16720 (2018) - Pulverized Fuel Ash - Cement Bricks |
Pulverized Fuel Ash - Cement Bricks |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 8.1 (General) |
500.0 |
|
| 8.2 (Dimension, Length, in mm) |
500.0 |
|
| 8.2 (Dimensions, Width) |
500.0 |
|
| 8.2 (Dimensions, Thickness, in mm) |
500.0 |
|
| 8.3 (Density, in kg/m^3) |
1000.0 |
|
| 8.4 (Compressive Strength, in N/mm^2) |
2000.0 |
|
| 8.5 (Drying Shrinkage, in %) |
2000.0 |
|
| 8.6 (Water Absorption Test) |
1000.0 |
|
|
| 150 |
National Test House (ER), Kolkata
| IS 516(Part 1/Section 1):2021 - Hardened Concrete-Methods of Tests-( Part 1-Testing of strength of Hardened Concrete-Determination of Compressive, Flexural strength and Split tensile strength) |
Hardened Concrete-Methods of Tests-( Part 1-Testing of strength of Hardened Concrete-Determination of Compressive, Flexural strength and Split tensile strength) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 3 (Compressive strength of concrete cubes(MPa)) |
1200.0 |
|
|