| 721 |
National Test House (WR), Mumbai
| IS 8986 (2022) (2022) - Hexagonal Integral Drill Steel and Extension Rods and Hollow Round Drill Steel in Bar Form — Dimensions
(Second Revision) |
Hexagonal Integral Drill Steel and Extension Rods and Hollow Round Drill Steel in Bar Form — Dimensions
(Second Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 2 (Dimension - Hexagonal Integral Drill Steel and Extension Rods in mm Clause 2.1 and Table 1 of IS 8986 or any other relevant National & International Standard Specified) |
1000.0 |
|
| 2 (Dimension -Hollow Round Drill Steel in Bar Form for Extension Rods, in mm, Clause 2.2, Table 2 of IS 8986 or any other national or International Stanard specified) |
1000.0 |
|
| 2 (Mass per Meter in Kg/M as per Table 1 or 2 of IS 8986 or any other National or International Standard specified.) |
1000.0 |
|
| 0 (Rockwell Hardness Test in HRC) |
2000.0 |
|
| 0 (Mechanical Properties - Tensile Strength, Yield Strength and % of Elongation as per IS 1608 Prt-1 or ASTM E8 or any other relevant National or International specification.) |
4000.0 |
|
| 2 (Sectional Area in mm2 as per IS 8986 Clause 2 Table 1 /Table 2) |
1000.0 |
|
| 0 (Chemical Composition in mass% by OES method or any other National or International product specification specified test method.) |
3500.0 |
|
|
| 722 |
National Test House (SR), Chennai
| IS 2556(Part 15):2024 - Vitreous China Sanitary Appliances-Specification ( Part 15)-Specific requirements of Universal Water Closets |
Vitreous China Sanitary Appliances-Specification ( Part 15)-Specific requirements of Universal Water Closets |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 3 (General requirements-IS 2556(1)) |
6000.0 |
|
| 4 (Sizes) |
500.0 |
|
| 5 (Dimensions and Tolerances) |
2000.0 |
|
| 6 (Construction) |
1000.0 |
|
| 7 (Finish) |
500.0 |
|
| 8.2 (Flushing Test-Toilet Paper Test) |
600.0 |
|
| 8.3 (Flushing Test-Smudge Test) |
1000.0 |
|
| 8.4 (Flushing Test-Holding Capacity Test) |
1000.0 |
|
| 8.5.1 (Single ball Test) |
600.0 |
|
| 8.5.2 (Fifty Ball Test) |
600.0 |
|
| 8.6 (Saw Dust Test) |
600.0 |
|
| 8.7 (Splash Test) |
600.0 |
|
| 9 (Load bearing Test) |
1000.0 |
|
|
| 723 |
National Test House (ER), Kolkata
| CUSTOM/WPC DOOR SHUTTER/2025 - WPC DOOR SHUTTER |
WPC DOOR SHUTTER |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1.0 (Density) |
1000.0 |
|
| 2.0 (Dimension & Squareness Test) |
2000.0 |
|
| 3.0 (Impact Indentation Test) |
1000.0 |
|
| 4.0 (Edge Loading Test) |
1500.0 |
|
| 5.0 (Shock Resistance Test) |
1500.0 |
|
| 6.0 (Slamming Test) |
1000.0 |
|
| 7.0 (Screw Withdrawal Resistance Test) |
1500.0 |
|
|
| 724 |
National Test House (ER), Kolkata
| IS/RDSO-GE/0001:23 (2023) - Specification for Track Ballast |
Specification for Track Ballast |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 2.2 (Aggregate Abrasion Value, Average Value in %) |
2000.0 |
|
| 2.2 (Aggregate Impact Value, Average value in %) |
2000.0 |
|
| 2.2.3 (Water Absorption, in %) |
1000.0 |
|
| 2.3 (Sieve Analysis, Retention on 65mm sq. mesh sieve, in %) |
1000.0 |
|
| 203 (Sieve Analysis, Retention on 40mm sq. mesh sieve, in %) |
1000.0 |
|
| 2.3 (Sieve Analysis, Retention on 20mm sq. mesh sieve, in %) |
1000.0 |
|
|
| 725 |
National Test House (ER), Kolkata
| CUSTOM/PVC FURNITURE BOARD/2025 - PVC FURNITURE BOARD |
PVC FURNITURE BOARD |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1.0 (Visual Appearance) |
1000.0 |
|
| 2.0 (Density) |
1000.0 |
|
| 3.0 (Edge Loading Test) |
1500.0 |
|
| 4.0 (Shock Resistance Test) |
1500.0 |
|
| 5.0 (Buckling Resistance Test) |
1500.0 |
|
| 6.0 (Misuse Test) |
1000.0 |
|
| 7.0 (Slamming Test) |
1000.0 |
|
| 8.0 (Screw Withdrawal Resistance Test) |
1500.0 |
|
| 9.0 (Elastic Modulus) |
2000.0 |
|
| 10.0 (Water Absorption) |
1000.0 |
|
| 11.0 (Compressive Strength) |
2000.0 |
|
|
| 726 |
National Test House (ER), Kolkata
| CUSTOM/WPC DOOR FRAME/2025 - WPC DOOR FRAME |
WPC DOOR FRAME |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1.0 (Water Absorption) |
1000.0 |
|
| 2.0 (Density) |
1000.0 |
|
| 3.0 (Screw Withdrawal Strength) |
1500.0 |
|
| 4.0 (Compressive Strength) |
2000.0 |
|
| 5.0 (Modulus of Elasticity) |
2000.0 |
|
|
| 727 |
National Test House (WR), Mumbai
| IS 17044 (2018) - Intumescent fire retardant paint (Water Based) - Specification |
Intumescent fire retardant paint (Water Based) - Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Intumescent fire retardant paint (Water Based) - Specification (Please refer to the annexure for the test result) |
10000.0 |
|
|
| 728 |
National Test House (WR), Mumbai
| IS 5758 (2020) - Precast Concrete Kerbs, Channels, Edgings, Quadrants and Gutter Aprons |
Precast Concrete Kerbs, Channels, Edgings, Quadrants and Gutter Aprons |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 9.2 (Dimensions, Overall Length, in mm) |
500.0 |
|
| 9.2 (Dimensions, Overall Height, in mm) |
500.0 |
|
| 9.2 (Overall Thickness, in mm) |
500.0 |
|
| 9.3 (Bending Strength, N/mm^2) |
4000.0 |
|
| 9.4 (Water Absorption, in %) |
2000.0 |
|
| 4.2 (Shape and Profile) |
1000.0 |
|
|
| 729 |
National Test House (WR), Mumbai
| IS 15961 (2012) - Hot dip aluminium - Zinc alloy metallic coated steel strip and sheet (Plain) |
Hot dip aluminium - Zinc alloy metallic coated steel strip and sheet (Plain) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 9 (Triple Spot Coating Mass) |
2000.0 |
|
|
| 730 |
National Test House (WR), Mumbai
| IS 15965 : 2012 (2012) - Pre-painted Aluminium Zinc Alloy Metallic Coated Steel Strip and Sheet (Plain) |
Pre-painted Aluminium Zinc Alloy Metallic Coated Steel Strip and Sheet (Plain) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 3.3 (Total Coated Thickness (As received condition), mm) |
1000.0 |
|
| 8 (Tensile Strength (As per IS 15961), MPa) |
1000.0 |
|
| 8 (Yield Strength (As per IS 15961), MPa) |
1000.0 |
|
| 8 (% Elongation (As per IS 15961), %) |
1000.0 |
|
| 7.1 (Mass of Coating (Both sides), g/m²) |
2000.0 |
|
| 5 (Chemical composition (As per IS 513), % by mass) |
2500.0 |
|
| 1 (Composition of AZ Coating Material in %) |
3000.0 |
|
|
| 731 |
National Test House (ER), Kolkata
| Customs paint Road Marking (2025) - Customs paint Road Marking |
Customs paint Road Marking |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Film Thickness Dry) |
1200.0 |
|
| 2 (Film Thickness Wet) |
1200.0 |
|
| 3 (Colour) |
1200.0 |
|
| 4 (Condition) |
1200.0 |
|
| 5 (Surface Dry) |
1200.0 |
|
| 6 (Hard dry) |
1200.0 |
|
| 7 (Viscosity) |
1200.0 |
|
| 8 (Colour) |
1200.0 |
|
| 9 (Compatibility with Road marking paint) |
2500.0 |
|
| 10 (Prerequisite for Road marking paint testing
a)Mass in Kg/10L
b)Condition in container
c)Finish
d)Resistance to wear) |
5000.0 |
|
|
| 732 |
National Test House (WR), Mumbai
| Customized Specification for Plastic Bottle with cap - Customized Specification for Plastic Bottle with cap |
Customized Specification for Plastic Bottle with cap |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| - (Identification of Plastic bottle body by FTIR) |
2000.0 |
|
| - (Identification of plastic cap by FTIR) |
2000.0 |
|
|
| 733 |
National Test House (ER), Alipore
| Customs paint Road Marking (2025) - Customs paint Road Marking |
Customs paint Road Marking |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Film Thickness Dry) |
1200.0 |
|
| 2 (Film Thickness Wet) |
1200.0 |
|
| 3 (Colour) |
1200.0 |
|
| 4 (Condition) |
1200.0 |
|
| 5 (Surface Dry) |
1200.0 |
|
| 6 (Hard dry) |
1200.0 |
|
| 7 (Viscosity) |
1200.0 |
|
| 9 (Compatibility with Road marking paint) |
2500.0 |
|
| 10 (Prerequisite for Road marking paint testing
a)Mass in Kg/10L
b)Condition in container
c)Finish
d)Resistance to wear) |
5000.0 |
|
|
| 734 |
National Test House (SR), Chennai
| IS 15965 : 2012 (2012) - Pre-painted Aluminium Zinc Alloy Metallic Coated Steel Strip and Sheet (Plain) |
Pre-painted Aluminium Zinc Alloy Metallic Coated Steel Strip and Sheet (Plain) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 3.3 (Total Coated Thickness (As received condition), mm) |
1000.0 |
|
| 8 (Tensile Strength (As per IS 15961), MPa) |
1000.0 |
|
| 8 (Yield Strength (As per IS 15961), MPa) |
1000.0 |
|
| 8 (% Elongation (As per IS 15961), %) |
1000.0 |
|
| 7.1 (Mass of Coating (Both sides), g/m²) |
2000.0 |
|
| 5 (Chemical composition (As per IS 513), % by mass) |
2500.0 |
|
|
| 735 |
National Test House (WR), Mumbai
| - (2025) - Customize General chemical specifical NTH (WR) |
Customize General chemical specifical NTH (WR) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| - (Appearance) |
500.0 |
|
| - (Specific gravity) |
1000.0 |
|
| - (Releasing Properties) |
3000.0 |
|
| - (Flash Point by COC) |
1000.0 |
|
| - (Fire Point by COC) |
1000.0 |
|
| - (Aluminium Reactivity at 60 deg. C for 72 hours) |
1000.0 |
|
| - (Effect on Wooden Ply at 60 deg C. for 72 hours) |
1000.0 |
|
| - (Viscosity by Flow Cup) |
1000.0 |
|
|
| 736 |
National Test House (NWR), Jaipur
| IS 1367 : Part 3 (2017) - Technical Supply Conditions for Threaded Steel Fasteners Part 3 Mechanical Properties of Fasteners Made of Carbon Steel and Bolts, Screws and Studs |
Technical Supply Conditions for Threaded Steel Fasteners Part 3 Mechanical Properties of Fasteners Made of Carbon Steel and Bolts, Screws and Studs |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6 (Chemical Composition, % by mass) |
2500.0 |
|
| 7 (Mechanical and physical properties (Hardness,Rockwell C scale)) |
2000.0 |
|
| 7 (Mechanical and physical properties (Proof load test)) |
2000.0 |
|
| 7 (Mechanical and physical properties (ultimate tensile load)) |
3000.0 |
|
| 2 (Dimensions) |
1000.0 |
|
| 9.1.4 (Wedge Load test as per IS 1367 Part 3) |
3000.0 |
|
|
| 737 |
National Test House (SR), Chennai
| IS 9857:1990 (1990) - Welding Cable Specification |
Welding Cable Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
| 738 |
National Test House (NER), Guwahati
| CUS/SR/MECH-55 (2024) - Mechanical Properties of Metal |
Mechanical Properties of Metal |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 11.0 (Yield Load, kN) |
3000.0 |
|
| 10.0 (Tensile Load, kN) |
3000.0 |
|
| 17.0 (Mass per metre run, kg/m) |
1000.0 |
|
| 1.0 (Dimensions, mm) |
2000.0 |
|
| 8.0 (Percentage Elongation, %) |
1000.0 |
|
| 13.0 (Carbon, % by mass) |
500.0 |
|
| 14.0 (Sulphur, % by mass) |
500.0 |
|
| 15.0 (Phosphorus, % by mass) |
500.0 |
|
| 16.0 (Manganese, % by mass) |
500.0 |
|
| 18 (Aluminium, % by mass) |
1000.0 |
|
| 20 (Carbon Equivalent) |
2000.0 |
|
| 6.0 (Tensile strength, N/mm²) |
1000.0 |
|
| 7.0 (Yield strength, N/mm²) |
1000.0 |
|
| 21 (Yield Stress, N/mm²) |
1000.0 |
|
|
| 739 |
National Test House (ER), Kolkata
| IS 4229 (1992) - Textiles – Nylon sewing threads for aerospace purposes – Specification (second revision) |
Textiles – Nylon sewing threads for aerospace purposes – Specification (second revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Firm's request (Average Breaking Strength, N) |
2000.0 |
|
| Firm's request (Elongation at break , percent) |
1000.0 |
|
|
| 740 |
National Test House (NWR), Jaipur
| IS 3757 (1985) - Specification for high strength structural bolts (Second Revision) |
Specification for high strength structural bolts (Second Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 2 (Dimension (Length of bolt)) |
200.0 |
|
| 2 (Dimension (Shank Diameter)) |
200.0 |
|
| 2 (Dimension (Width across the flat)) |
400.0 |
|
| 2 (Dimension (Width across the edge)) |
400.0 |
|
| 2 (Dimension (Height of the head)) |
400.0 |
|
| 4 (Mechanical Properties(Tensile Strength) as per IS 1367(Part-3):2017 Clause No.- 7) |
3000.0 |
|
| 4 (Mechanical Properties(Proof Load Test) as per IS 1367(Part-3):2017 Clause No.- 7) |
2000.0 |
|
| 4 (Mechanical Properties(Ultimate Tensile Load) as per IS 1367(Part-3):2017 Clause No.- 7) |
2000.0 |
|
| 4 (Mechanical Properties(Vickers Hardness ) as per IS 1367(Part-3):2017 Clause No.- 7) |
2000.0 |
|
| 4 (Mechanical Properties( Rockwell Hardness Scale- C) as per IS 1367(Part-3):2017 Clause No.- 7) |
2000.0 |
|
| 4 (Carbon) |
500.0 |
|
| 4 (Sulfur) |
500.0 |
|
| 4 (Phosphorus) |
500.0 |
|
| 4 (Boron) |
500.0 |
|
|
| 741 |
National Test House (SR), Chennai
| IS 9143:1979 - Indian standard-Method for the determination of Unconfined Compressive strength of Rock materials |
Indian standard-Method for the determination of Unconfined Compressive strength of Rock materials |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6 (Unconfined Compressive strength /Uniaxial Compressive strength-N/ Sq mm) |
5000.0 |
|
|
| 742 |
National Test House (NER), Guwahati
| IS 1540 : Part 2 (1990) - Quicklime and hydrated lime for chemical industries - Specification: Part 2 hydrated lime (Third Revision) |
Quicklime and hydrated lime for chemical industries - Specification: Part 2 hydrated lime (Third Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5.2 (Moisture) |
1000.0 |
|
| 5.2 (Available Lime (as Ca(OH)2) |
1000.0 |
|
| 5.2 (Acid insoluble matter (as SiO2)) |
1000.0 |
|
| 5.2 (Magnesia ( as MgO)) |
1000.0 |
|
| 5.2 (Manganese ( as Mn2O3 )) |
1000.0 |
|
|
| 743 |
National Test House (ER), Kolkata
| Custom Specification for Molecular Hydrogen Oxygen Generator - Custom Specification for Molecular Hydrogen Oxygen Generator |
Custom Specification for Molecular Hydrogen Oxygen Generator |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| A1 (Physical Verification) |
2000.0 |
|
| A2 (Electrical Parameters) |
3000.0 |
|
| A3 (Electrical Safety Test) |
5000.0 |
|
| A4 (Environmental Test) |
20000.0 |
|
|
| 744 |
National Test House (WR), Mumbai
| 16720 (2018) - Pulverized Fuel Ash - Cement Bricks |
Pulverized Fuel Ash - Cement Bricks |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 8.1 (General) |
500.0 |
|
| 8.2 (Dimension, Length, in mm) |
500.0 |
|
| 8.2 (Dimensions, Width) |
500.0 |
|
| 8.2 (Dimensions, Thickness, in mm) |
500.0 |
|
| 8.3 (Density, in kg/m^3) |
1000.0 |
|
| 8.4 (Compressive Strength, in N/mm^2) |
2000.0 |
|
| 8.5 (Drying Shrinkage, in %) |
2000.0 |
|
| 8.6 (Water Absorption Test) |
1000.0 |
|
|
| 745 |
National Test House (WR), Mumbai
| IS 18387 (2023) - Gypsum Ceiling Tiles |
Gypsum Ceiling Tiles |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 7.1.1 (Dimensions and Tolerances on size, Length in mm) |
500.0 |
|
| 7.1.1 (Dimensions and Tolerances on Size, Width) |
500.0 |
|
| 7.1.2 (Dimensions and Tolerances on Edges Profile) |
500.0 |
|
| 7.2.2 (Tolerances on Squareness of Edges,) |
500.0 |
|
| 7.3 (Density, in kg/m^3) |
1000.0 |
|
| 7.4 (Flexural Breaking Strength (Length wise), in N) |
2000.0 |
|
| 7.4 (Flexural Breaking Strength (Across the length), in N) |
2000.0 |
|
| 7.5 (Water Absorption, in %) |
1000.0 |
|
| 7.8 (Humidified Deflection, in mm) |
5000.0 |
|
|
| 746 |
National Test House (ER), Alipore
| IS 2074 (2015) - Ready Mixed Paint, Air Drying, Red Oxide - Zinc Chrome, Priming - Specification |
Ready Mixed Paint, Air Drying, Red Oxide - Zinc Chrome, Priming - Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5.6, xii (Keeping properties) |
5000.0 |
|
| 5.6,xi (Accelerated storage stability test) |
200.0 |
|
| 5.6,x.c (Resistance to salt spray) |
500.0 |
|
| 5.6,x.b (Resistance to sea water (applicable for marine paints only)) |
50.0 |
|
| 5.6,x.a (Resistance to humidity) |
2500.0 |
|
| 5.6,ix (Volume solids) |
200.0 |
|
| 5.6,viii (Flash point) |
500.0 |
|
| 5.6,vii.b (Flexibility and adhesion: Scratch hardness (load 1000g)) |
100.0 |
|
| 5.6,vii.a (Flexibility and adhesion:Bend test (with 6.25 mm dia mandrel and in type 1 apparatus)) |
100.0 |
|
| 5.6,vi (Colour) |
50.0 |
|
| 5.6,v (Fineness of grind, microns) |
100.0 |
|
| 5.6,iv.b (Gloss, 60º) |
100.0 |
|
| 5.6,iv.a (Finish) |
100.0 |
|
| 5.6,iii.b (Drying: hard dry) |
100.0 |
|
| 5.6,iii.a (Drying: Surface dry) |
100.0 |
|
| 5.6,ii (Mass, kg/10litre) |
200.0 |
|
| 5.6,i. b (Viscosity by Ford cup No. 4 at 27 ± 2°C) |
200.0 |
|
| 5.6,i. a (Consistency) |
200.0 |
|
| 5.5 (Lead Restriction) |
200.0 |
|
| 5.3 (Compatibility with thinner) |
200.0 |
|
| 5.1.2 (Volatile vehicle) |
200.0 |
|
| 5.1.1.b (Synthetic red oxides of iron red
oxide (as Fe2O3)) |
1000.0 |
|
| 5.1.1.a (zinc oxide) |
500.0 |
|
| 5.1.1.a (chromic anhydride) |
1000.0 |
|
| 5.1.1.a (Zinc chrome) |
500.0 |
|
| 5.1.a (Pigment, percent by mass) |
1200.0 |
|
|
| 747 |
National Test House (ER), Alipore
| 15041:2001 (RA 2024) - Textiles – Flat woven webbing slings made of man-made fibres for general services |
Textiles – Flat woven webbing slings made of man-made fibres for general services |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 3.28 (Safe Working Load) |
3000.0 |
|
| 3.28 (Safe Working Load) |
6000.0 |
|
| 3.28 (Safe Working Load) |
8000.0 |
|
| 3.28 (Safe Working Load) |
10000.0 |
|
| 5.4 (Proof Load) |
3000.0 |
|
| 5.4 (Proof Load) |
5000.0 |
|
| 5.4 (Proof Load) |
8000.0 |
|
| 5.4 (Proof Load) |
10000.0 |
|
|
| 748 |
National Test House (ER), Alipore
| ASME BPVC Section V SE 165 - Standard Practice for Liquid Penetrant Examination for General Industry |
Standard Practice for Liquid Penetrant Examination for General Industry |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Flaw detection by Liquid Penetrant Test) |
1000.0 |
|
|
| 749 |
National Test House (ER), Alipore
| ASME BPVC Section V SD 7091 - Standard practice for Non-destructive measurement of Dry Film Thickness of Non-magnetic Coating applied to ferrous metals and Non-magnetic, Non-conductive coating applied to Non-ferrous Metals |
Standard practice for Non-destructive measurement of Dry Film Thickness of Non-magnetic Coating applied to ferrous metals and Non-magnetic, Non-conductive coating applied to Non-ferrous Metals |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Dry Film Thickness) |
2000.0 |
|
|
| 750 |
National Test House (ER), Alipore
| IS 1608 (Part1): 2022 - Metallic Materials-Tensile Testing-Method of Test at Room Temperature |
Metallic Materials-Tensile Testing-Method of Test at Room Temperature |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Tensile Testing) |
5000.0 |
|
|