| 361 |
National Test House (ER), Alipore
| F-6A EIL Specification No. 6-79-0020 Rev.1 (2024) - F-6A Epoxy High Build Coating |
F-6A Epoxy High Build Coating |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Volume Solid) |
2000.0 |
|
| 2 (Dry Film Thickness) |
1200.0 |
|
| 3 (Theoretical Covering capacity in sq.mt/coat/litre.) |
1500.0 |
|
| 4 (Weight per Litre) |
1200.0 |
|
| 5 (Touch dry at 30 deg.C) |
1200.0 |
|
| 6 (Hard Dry at 30 deg.c) |
1200.0 |
|
| 7 (Full cure at 30 deg.C) |
1200.0 |
|
| 8 (Over-coat interval) |
1200.0 |
|
| 9 (Pot Life at 30 deg.C for Two Component Paints) |
1500.0 |
|
| 10 (Adhesion (ASTM D 4541)) |
5000.0 |
|
| 11 (Temperature Resistance (Min)) |
3000.0 |
|
|
| 362 |
National Test House (ER), Alipore
| F-17 EIL Specification No. 6-79-0020 Rev.1 (2024) - F-17 Novolac Epoxy Phenolic Coating Cured with Polyamine Adduct Hardener |
F-17 Novolac Epoxy Phenolic Coating Cured with Polyamine Adduct Hardener |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Volume Solid) |
2000.0 |
|
| 2 (Dry Film Thickness) |
1200.0 |
|
| 3 (Theoretical Covering capacity in sq.mt/coat/litre.) |
1500.0 |
|
| 4 (Weight per Litre) |
1200.0 |
|
| 5 (Touch dry at 30 deg.C) |
1200.0 |
|
| 6 (Hard Dry at 30 deg.C) |
1200.0 |
|
| 7 (Full cure at 30 deg.C) |
1200.0 |
|
| 8 (Over-coat interval) |
1200.0 |
|
| 9 (Pot Life at 30 deg.C for Two Component Paints) |
1500.0 |
|
| 10 (Adhesion (ASTM D 4541)) |
5000.0 |
|
| 11 (Temperature Resistance (Min)) |
3000.0 |
|
|
| 363 |
National Test House (ER), Alipore
| F-15 EIL Specification No. 6-79-0020 Rev.1 - F-15, Two Component Epoxy Phenolic Coating Cured with Polyamine adduct Hardener |
F-15, Two Component Epoxy Phenolic Coating Cured with Polyamine adduct Hardener |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Volume Solid) |
2000.0 |
|
| 2 (Dry Film Thickness) |
1200.0 |
|
| 3 (Theoretical Covering capacity in sq.mt/coat/litre.) |
1500.0 |
|
| 4 (Weight per Litre) |
1200.0 |
|
| 5 (Touch dry at 30 deg.C) |
1200.0 |
|
| 6 (Hard Dry at 30 deg.C) |
1200.0 |
|
| 7 (Full cure at 30 deg.C) |
1200.0 |
|
| 8 (Over-coat interval) |
1200.0 |
|
| 9 (Pot Life at 30 deg.C for Two Component Paints) |
1500.0 |
|
| 10 (Adhesion (ASTM D 4541)) |
5000.0 |
|
| 11 (Temperature Resistance (Min)) |
3000.0 |
|
|
| 364 |
National Test House (ER), Alipore
| F-12 EIL Specification No. 6-79-0020 Rev.1 (2024) - F-12 Heat Resistance Silicon Aluminium paint |
F-12 Heat Resistance Silicon Aluminium paint |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Volume Solid) |
2000.0 |
|
| 2 (Dry Film Thickness) |
1200.0 |
|
| 3 (Therotical Covering capacity in sq.mt/coat/litres) |
1500.0 |
|
| 4 (Weight per Litre) |
1200.0 |
|
| 5 (Touch dry at 30 deg.C) |
1200.0 |
|
| 6 (Hard Dry at 30 deg.c) |
1200.0 |
|
| 7 (Over-coat interval) |
1200.0 |
|
| 8 (Temperature Resistance (Min)) |
3000.0 |
|
|
| 365 |
National Test House (ER), Alipore
| F14 EIL Specification No. 6-79-0020 Rev.1 (2014) - F-14 Polyamine cure coal tar epoxy |
F-14 Polyamine cure coal tar epoxy |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Volume Solid) |
2000.0 |
|
| 2 (Dry Film Thickness) |
1200.0 |
|
| 4 (Weight per Litre) |
1200.0 |
|
| 5 (Touch dry at 30 deg.C) |
1200.0 |
|
| 6 (Hard Dry at 30 deg.c) |
1200.0 |
|
| 7 (Full cure at 30 deg.) |
1200.0 |
|
| 8 (Over-coat interval) |
1200.0 |
|
| 9 (Pot Life at 30 deg.C for Two Component Paints) |
1500.0 |
|
| 10 (Adhesion (ASTM D 4541)) |
5000.0 |
|
| 11 (Temperature Resistance (Min)) |
3000.0 |
|
| 3 (Theoretical Covering capacity in sq.mt/coat/litre.) |
1500.0 |
|
|
| 366 |
National Test House (NR), Ghaziabad
| IS 8183:1993 - Bonded Mineral Wool |
Bonded Mineral Wool |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 4.1. (Description) |
1000.0 |
|
| 4.2 (Bulk density (IS 3144 )) |
1000.0 |
|
| 4.3 (Recovery after Compression(IS 3144)) |
1500.0 |
|
| 4.5 (Moisture content (IS 3144)) |
1000.0 |
|
| 4.5 (Moisture Absorption (IS 3144)) |
1000.0 |
|
| 4.8 (Sulphur content(IS 3144)) |
1000.0 |
|
| 4.9 (Dimension) |
1000.0 |
|
| 4.10.6 (Alkalinity ( IS 3144)) |
1000.0 |
|
| 4.4 (Shot Content) |
2000.0 |
|
|
| 367 |
National Test House (SR), Chennai
| on the lines of ASTM C109 & ASTM 1660 - Thin-bed Mortar for Autoclaved Aerated Concrete (AAC) masonry |
Thin-bed Mortar for Autoclaved Aerated Concrete (AAC) masonry |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| custom (Compressive strength -7 days & 28 days (on the lines of ASTM/IS)) |
4000.0 |
|
| custom (Split Tensile strength-On the lines of ASTM/IS
(7 days /28 days)) |
4000.0 |
|
|
| 368 |
National Test House (SR), Chennai
| IS 2250/On the lines of ASTM/IS 1727/2770 - MICRO CONCRETE |
MICRO CONCRETE |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| custom (Flow Test(on the lines of IS 2250)) |
1000.0 |
|
| custom (Compressive strength (on the lines of IS /ASTM)-1 Day) |
2000.0 |
|
| custom (Compressive strength (on the lines of IS /ASTM)-7 Days) |
2000.0 |
|
| custom (Compressive strength (on the lines of IS /ASTM)-28 Days) |
2000.0 |
|
| custom (Flexural strength -(on the lines of IS/ASTM)1 Day) |
2000.0 |
|
| custom (Flexural strength (on the lines of IS /ASTM)-7 Days) |
2000.0 |
|
| custom (Flexural strength (on the lines of IS /ASTM)-28 Days) |
2000.0 |
|
| custom (Drying Shrinkage (IS 1727)) |
1000.0 |
|
| custom (Split Tensile strength (IS 5816)) |
2000.0 |
|
| custom (Rebar Pull out Bond Strength(Max load in kN)) |
4000.0 |
|
| custom (Alkali aggregate reactivity(Mortar bar method)-IS/ASTM) |
3000.0 |
|
| custom (Co-efficient of Thermal Expansion(IS /ASTM)) |
3000.0 |
|
| custom (Scratch Hardness-Mohs' scale(-on the lines of IS 13630(13))) |
1500.0 |
|
|
| 369 |
National Test House (NWR), Jaipur
| IS/IEC 60168 (2000) - Tests on indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V |
Tests on indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 0 (Bending Test) |
5000.0 |
|
| 0 (Compression Test) |
5000.0 |
|
|
| 370 |
National Test House (NR), Ghaziabad
| CUSTOMER SPEC SILT - CUSTOMER SPEC SILT |
CUSTOMER SPEC SILT |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 4 (pH value) |
1200.0 |
|
| 3 (Electrical Conductivity) |
1200.0 |
|
| 2 (Moisture Content) |
1200.0 |
|
| 1 (Loss of ignition) |
1200.0 |
|
|
| 371 |
National Test House (ER), Alipore
| F-11 EIL Specification No. 6-79-0020 Rev.1 - F-11 Heat Resistance synthetic medium based Two pack Aluminium paint |
F-11 Heat Resistance synthetic medium based Two pack Aluminium paint |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Volume Solid) |
2000.0 |
|
| 2 (Dry Film Thickness) |
1200.0 |
|
| 3 (.Therotical Covering capacity in sq.mt/coat/litres.) |
1500.0 |
|
| 4 (Weight per Litre) |
1200.0 |
|
| 5 (Touch dry at 30 deg.C) |
1200.0 |
|
| 6 (Hard Dry at 30 deg.C) |
1200.0 |
|
| 7 (Over-coat interval) |
1200.0 |
|
| 8 (Temperature Resistance (Min)) |
1200.0 |
|
|
| 372 |
National Test House (ER), Alipore
| F-9 EIL Specification No. 6-79-0020 Rev.1 (2024) - F-9 Inorganic zinc silicate Coating |
F-9 Inorganic zinc silicate Coating |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Volume Solid) |
2000.0 |
|
| 2 (Dry Film Thickness) |
1200.0 |
|
| 3 (Theoretical Covering capacity in sq.mt/coat/litre) |
1500.0 |
|
| 4 (Weight per Litre) |
1200.0 |
|
| 5 (Touch dry at 30 deg.C) |
1200.0 |
|
| 6 (Hard Dry at 30 deg. C) |
1200.0 |
|
| 7 (Pot Life at 30 deg.C for Two Component Paints) |
1200.0 |
|
| 8 (Adhesion (ASTM D 4541)) |
5000.0 |
|
| 10 (Temperature Resistance (Min)) |
3000.0 |
|
| 9 (Over-coat interval) |
1200.0 |
|
|
| 373 |
National Test House (ER), Alipore
| F-7 EIL Specification No. 6-79-0020 Rev.1 (2024) - F-7 High build coal tar epoxy Coating |
F-7 High build coal tar epoxy Coating |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Volume Solid) |
2000.0 |
|
| 3 (Therotical Covering capacity in sq.mt/coat/litres.) |
1500.0 |
|
| 4 (Weight per Litres) |
1200.0 |
|
| 5 (Touch dry at 30 deg.C) |
1200.0 |
|
| 2 (Dry Film Thickness) |
1200.0 |
|
| 6 (Hard Dry at 30 deg.c) |
1200.0 |
|
| 7 (Full cure at 30 deg.C) |
1200.0 |
|
| 8 (Over-coat interval) |
1200.0 |
|
| 9 (Pot Life at 30 deg.C for Two Component Paints) |
1500.0 |
|
| 10 (Adhesion (ASTM D 4541)) |
5000.0 |
|
| 11 (Temperature Resistance (Min)) |
3000.0 |
|
|
| 374 |
National Test House (ER), Alipore
| P-4 EIL Specification No. 6-79-0020 Rev.1 (2024) - P-4 Etch Primer/Wash Primer |
P-4 Etch Primer/Wash Primer |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Volume Solid) |
2000.0 |
|
| 2 (Dry Film Thickness) |
1200.0 |
|
| 3 (Therotical Covering Capacity) |
1500.0 |
|
| 4 (Weight per Litres) |
1200.0 |
|
| 5 (Touch dry at 30 deg.C) |
1200.0 |
|
| 6 (Hard Dry at 30 deg.c) |
1200.0 |
|
| 7 (Over-coat interval) |
1200.0 |
|
|
| 375 |
National Test House (ER), Alipore
| F-8 EIL Specification No. 6-79-0020 Rev.1 (2024) - F-8 Self priming type Surface tolerant High build coal tar epoxy Coating |
F-8 Self priming type Surface tolerant High build coal tar epoxy Coating |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Volume Solid) |
2000.0 |
|
| 2 (Dry Film Thickness) |
1200.0 |
|
| 3 (Theoretical Covering capacity in sq.mt/coat/litres) |
1500.0 |
|
| 4 (Weight per Litres) |
1200.0 |
|
| 5 (Touch dry at 30 deg.C) |
1200.0 |
|
| 6 (Hard Dry at 30 deg.c) |
1200.0 |
|
| 7 (Full cure at 30 deg.) |
1200.0 |
|
| 8 (Over-coat interval) |
1200.0 |
|
| 9 (Pot Life at 30 deg.C for Two Component Paints) |
1500.0 |
|
| 10 (Adhesion (ASTM D 4541)) |
5000.0 |
|
| 11 (Temperature Resistance (Min)) |
3000.0 |
|
|
| 376 |
National Test House (ER), Alipore
| F-2 EIL Specification No. 6-79-0020 Rev.1 (2024) - F-2 Acrylic Polyurethane Finish Paint |
F-2 Acrylic Polyurethane Finish Paint |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Volume Solid) |
2000.0 |
|
| 2 (Dry Film Thickness) |
1200.0 |
|
| 3 (Theoretical Covering capacity in sq.mt/coat/litres.) |
1500.0 |
|
| 4 (Weight per Litre) |
1200.0 |
|
| 5 (Touch dry at 30 deg. C) |
1200.0 |
|
| 6 (Hard Dry at 30 deg.c) |
1200.0 |
|
| 7 (Full cure at 30 deg.C) |
1200.0 |
|
| 8 (Over-coat interval) |
1200.0 |
|
| 9 (Pot Life at 30 deg.C for Two Component Paints) |
1500.0 |
|
| 10 (Adhesion (ASTM D 4541)) |
5000.0 |
|
| 11 (Abrasion Resistance (ASTM D4060)) |
5000.0 |
|
| 12 (Temperature Resistance (Min) deg. c (ASTM D 2485)) |
3000.0 |
|
|
| 377 |
National Test House (ER), Alipore
| P-6 EIL Specification No. 6-79-0020 Rev. 1 - P-6 Epoxy Zinc Phosphate Primer |
P-6 Epoxy Zinc Phosphate Primer |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Volume Solid) |
2000.0 |
|
| 2 (Dry Film Thickness) |
1200.0 |
|
| 3 (Therotical Covering Capacity) |
1500.0 |
|
| 4 (Weight per Litres) |
1200.0 |
|
| 5 (Touch dry at 30 deg.C) |
1200.0 |
|
| 6 (Hard Dry at 30 deg.c) |
1200.0 |
|
| 7 (Over-coat interval) |
1200.0 |
|
| 8 (Pot Life at 30 deg.C for Two Component Paints) |
1500.0 |
|
| 9 (Adhesion (ASTM D 4541)) |
5000.0 |
|
| 10 (Temperature Resistance (Min)) |
3000.0 |
|
|
| 378 |
National Test House (ER), Alipore
| F-7 EIL SPECIFICATION for surface preparation & Protective coating System - High Build Coal Tar Epoxy Coating |
High Build Coal Tar Epoxy Coating |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Volume Solid) |
2000.0 |
|
| 2 (Dry Film Thickness) |
1200.0 |
|
| 3 (Therotical Covering capacity in sq.mt/coat/litres.) |
1500.0 |
|
| 4 (Weight per Litres) |
1200.0 |
|
| 5 (Touch dry at 30 deg.C) |
1200.0 |
|
| 6 (Hard Dry at 30 deg.c) |
1200.0 |
|
| 7 (Full cure at 30 deg.C) |
1200.0 |
|
| 8 (Over-coat interval) |
1200.0 |
|
| 9 (Pot Life at 30 deg.C for Two Component Paints) |
1500.0 |
|
| 10 (Adhesion (ASTM D 4541)) |
5000.0 |
|
| 11 (Temperature Resistance (Min)) |
3000.0 |
|
|
| 379 |
National Test House (NR), Ghaziabad
| Custom NR HV TPMO - As per Customer Test Request |
As per Customer Test Request |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1.0 (As per DVVNL GTP (Annexure Attached)) |
56000.0 |
|
|
| 380 |
National Test House (WR), Mumbai
| IS 383 (2016) & CPWD Vol. I Specifications - Specification for Coarse & Fine Aggregate |
Specification for Coarse & Fine Aggregate |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6.3 (Sieve Analysis) |
2000.0 |
|
| 2386 Part 3 (Moisture Content) |
1000.0 |
|
| 2386 Part 3 (Specific Gravity) |
500.0 |
|
| CPWD Specs (Silt Content) |
1000.0 |
|
| MoRTH Specs (Fineness Modulus) |
500.0 |
|
| 2386 Part 3 (Water Absorption) |
1000.0 |
|
| 2.1 (Aggregate Crushing Value) |
1500.0 |
|
| 3 of 2386-IV (Fine Value) |
1500.0 |
|
| 4 of 2386-IV (Aggregate Impact Value) |
1500.0 |
|
| 5 of 2386-IV (Aggregate Abrasion Value) |
1500.0 |
|
| 4 of 2386 Part 1 (Flakiness Index, %) |
1500.0 |
|
| 5 of IS 2386-I (Elongation Index, %) |
1500.0 |
|
| 4, 5 of IS 2386 (Combined Flakiness & Elongation Indices) |
3000.0 |
|
| 4.0 Bulking of Sand (Bulking of Sand) |
1000.0 |
|
| Organic Impurities (Organic Impurities) |
1000.0 |
|
| 5.7 (Acid soluble chloride / Chloride content) |
1000.0 |
|
| 5.7 (Sulphate Content) |
1000.0 |
|
| 5.6 (3) (Alkali Aggregate Reaction (Accelerated Mortar Bar Method)) |
5000.0 |
|
| 5.6 (2) (Alkali Aggregate Reaction (Mortar Bar Method)) |
4000.0 |
|
| 5.6 (2) (Alkali Aggregate Reaction (Mortar Bar Method)) |
5000.0 |
|
| 506 (2) (Alkali Aggregate Reaction (Mortar Bar Method)) |
8000.0 |
|
| 5.6 (2) (Alkali Aggregate Reaction (Mortar Bar Method)) |
10000.0 |
|
|
| 381 |
National Test House (NR), Ghaziabad
| IS 16985 (2018) - Duplex board/coated duplex board - Specification |
Duplex board/coated duplex board - Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6.3 (Thickness) |
1000.0 |
|
| 6.4 (Grammage) |
1000.0 |
|
| Table 1(i) (Bulk) |
1000.0 |
|
| Table 1(ii) (Moisture Content) |
1000.0 |
|
| Table 1(iii) (One minute cobb, Top) |
1000.0 |
|
| Table 1(iii) (One minute cobb, Back) |
1000.0 |
|
| Table 1(iv) (Taber Stiffness) |
2000.0 |
|
| Table 1(v) (Brightness) |
2000.0 |
|
| Table 1(vi) (Gloss) |
2000.0 |
|
|
| 382 |
National Test House (WR), Mumbai
| 3670 (1989) - Construction of Timber Floors - Code of Practice |
Construction of Timber Floors - Code of Practice |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6.2 (Moisture Content) |
1000.0 |
|
| Annex D-2.2 (Modulus of Rupture, N/mm^2) |
2000.0 |
|
| Annex D-2.1 (Modulus of Elasticity, N/mm^2) |
2000.0 |
|
| Annex D-1.2 (Hardness under static indentation, N) |
1500.0 |
|
| - - (Test for Screw and Nail Withdrawal, N) |
3000.0 |
|
| - - (Test for Specific Gravity) |
500.0 |
|
|
| 383 |
National Test House (NWR), Jaipur
| IS 7904 (2018) - High carbon steel wire rods - Specification (Second Revision) |
High carbon steel wire rods - Specification (Second Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 7 (Carbon) |
500.0 |
|
| 7 (Chromium) |
500.0 |
|
| 7 (Sulphur) |
500.0 |
|
| 7 (Manganese) |
500.0 |
|
| 10 (Mechanical Properties (Tensile, Yield, Elongation & RA)) |
4000.0 |
|
|
| 384 |
National Test House (ER), Alipore
| IS 101 (2015) - Determination of Volatile Organic Compound (VOC) Content gram per litre— Difference Method |
Determination of Volatile Organic Compound (VOC) Content gram per litre— Difference Method |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 8.3 (Volatile Organic Compound (VOC) Content gram per liter
(on the lines of IS 101part2/Sec-1):1988 & IS 101 Part 2/Sec2):1986) |
4000.0 |
|
|
| 385 |
National Test House (WR), Mumbai
| IS 3854:2023 (2023) - Switches for Domestic and Similar Purposes [upto 63A] |
Switches for Domestic and Similar Purposes |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 26.1 (Type Tests) |
20000.0 |
|
| 26.2 (Acceptance tests) |
10000.0 |
|
| 19.1 (Normal Operation) |
5000.0 |
|
| 19.2 (Test for Switches Intended for Externally Ballasted Lamp Loads) |
5000.0 |
|
| 19.3 (Test for Switches Intended for Self-ballasted Lamp Loads) |
5000.0 |
|
|
| 386 |
National Test House (SR), Chennai
| on the lines of IS 2547(1)/IS 2250/IS 15477/Customer technical specification - on the lines of Gypsum plaster /Masonry Mortars/Jointing Mortar |
on the lines of Gypsum plaster /Masonry Mortars/Jointing Mortar |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| custom (Chloride Content) |
1200.0 |
|
| custom (Bulk density -on the lines of IS 2386 (Part 3)) |
2000.0 |
|
| custom (Drying shrinkage (on the lines of Is 1727)) |
2000.0 |
|
| custom (Compressive strength ( duration 3,7, 28 days)) |
4000.0 |
|
| custom (Physical Requirements
(on the lines of IS/ customer Technical specifications)) |
15000.0 |
|
|
| 387 |
National Test House (NWR), Jaipur
| IS:16647:2017 - Oriented Unplasticized Polyvinyl Chloride (PVC-O) Pipes for water Supply |
Oriented Unplasticized Polyvinyl Chloride (PVC-O) Pipes for water Supply |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 7.1 (Visual Appreance, IS:16647) |
1000.0 |
|
| 7.2 (Colour, IS:16647) |
1000.0 |
|
| 5.5 (Density, IS:12235(part-14)) |
2000.0 |
|
| 7.3 (Opacity, IS:12235 (Part3)) |
1000.0 |
|
| 8.1.1.1 (Nominal Outside diameter, IS:16647) |
1000.0 |
|
| 8.1.1.2 (Diameter at any point, IS:16647) |
1000.0 |
|
| 8.1.2 (Wall Thickness, IS:16647) |
1000.0 |
|
| 8.3 (Pipe Ends) |
1000.0 |
|
| 9.1.1 (Resistance to Hydrostatic Pressure (Acceptance test), IS:16647) |
5000.0 |
|
| 9.2 (Resistance to External Blows at 0 deg.C, IS:12235(Part-9)) |
2000.0 |
|
| 10 (Vicat softening Temperature, IS:12235(Part-2)) |
2000.0 |
|
| 10 (Resistance to Di-chloromethane at a specific temperature, IS:12235(Part-11)) |
2000.0 |
|
| 10 (Effect on Water, IS:12235 (Part-4&10)) |
5000.0 |
|
|
| 388 |
National Test House (WR), Mumbai
| None - Pumice for Use as Filter Medium |
Pumice for Use as Filter Medium |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 4.4.1 (Particle Size Distribution [on the lines of IS 2720 - Part 4],) |
2000.0 |
|
| 4.1.1 (Effective Size [ on the lines of IS 2720 - Part 4],) |
1000.0 |
|
| 4.1.1 (Specific Gravity [IS 2386 - Part 3]) |
1000.0 |
|
| 4.1.1 (Loose Bulk Density [IS 2386 - Part 3], kg/m^3) |
500.0 |
|
| 4.1.1 (Compacted Bulk Density [IS 2386 - Part 3], kg/m^3) |
500.0 |
|
| 4.1.4 (Loss on Ignition [on the lines of IS 17955 - Annex C]) |
1000.0 |
|
| 4.1.1 (Silica as SiO2 [ on the lines of IS 2000 - Part 2], %) |
2000.0 |
|
| - (Sodium as Na2O [on the lines of IS 1917 - Part 2], %) |
500.0 |
|
| - (Potassium as K2O [on the lines of IS 1917 - Part 2], %) |
500.0 |
|
| - (Aluminium as Al2O3 [on the lines of IS 1917 - Part 4], %) |
500.0 |
|
| - (Iron as Fe2O3 [on the lines of IS 1917 - Part 5], %) |
500.0 |
|
| - (Cromium as Cr2O3 [using AAS method], %) |
1000.0 |
|
| - (Calcium as CaO [on the lines of IS 1917 - Part 6], %) |
500.0 |
|
| - (Magnesium as MgO [on the lines of IS 1917 - Part 6], %) |
500.0 |
|
| - (Titania as TiO2 [on the lines of IS 1917 - Part 7], %) |
1000.0 |
|
| - (pH of aqueous solution) |
1000.0 |
|
|
| 389 |
National Test House (WR), Mumbai
| - - - Micro Sand for Use as Filter Medium |
Micro Sand for Use as Filter Medium |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 4.2.2 (Effective Size (on the lines of IS 17955 )) |
1000.0 |
|
| 4.2.2 (Uniformity Coefficient (on the lines of IS 17955)) |
1000.0 |
|
| 4.2.2 (Grain Size Analysis ( on the lines of IS 2720-Part 4)) |
2000.0 |
|
| 4.1.4 (Loss on Ignition [on lines of Annex C of IS 17955]) |
1000.0 |
|
| 4.1.2 (Silica Content (SiO2) [ on the lines of IS 17955]) |
2000.0 |
|
| - - (Sodium as Na2O [on the lines of IS 1917(Part 2)], %) |
500.0 |
|
| - - (Potassium as K2O [on the lines of IS 1917(Part 2)], %) |
500.0 |
|
| - - (Iron as Fe2O3 [on the lines of IS 1917(Part 5)], %) |
500.0 |
|
| - - (Calcium as CaO [on the lines of IS 1917(Part 6)], %) |
500.0 |
|
| - - (Aluminium as Al2O3 [on the lines of IS 1917(Part 4)], %) |
500.0 |
|
| - - (Titania as TiO [on the lines of IS 1917(Part 7)], %) |
1000.0 |
|
| - - (Cromium as Cr2O3 [using AAS], %) |
1000.0 |
|
| - - (pH of aqueous solution) |
1000.0 |
|
| - - (Magnesium as MgO [on the lines of IS 1917(Part 6)], %) |
500.0 |
|
|
| 390 |
National Test House (ER), Kolkata
| Custom/Jute Yarn |
- |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1.0 (Breaking Load) |
1000.0 |
|
| 2.0 (Elongation at break) |
1000.0 |
|
| 3.0 (Twist in Yarn) |
1000.0 |
|
| 4.0 (Universal Count of Jute Yarn) |
1000.0 |
|
|