961 |
IP CODE : IS/IEC :60529 (2001 reaff : 2019) - Degree of protection provided by Enclosure(IP Code) |
Degree of protection provided by Enclosure(IP Code) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
13.2 First Characteristic Numeral 1 (13.2 First Characteristic Numeral 1 :Protection against solid foreign objects of 50 mm dia and greater) |
7500.0 |
|
13.2 First Characteristic Numeral 2 (13.2 First Characteristic Numeral 2 :Protection against solid foreign objects of 12.5 mm dia and greater) |
7500.0 |
|
13.2 First Characteristic Numeral 3 (13.2 First Characteristic Numeral 3 : Protected against solid foreign objects of 2.5 mm dia and greater) |
7500.0 |
|
13.2 First Characteristic Numeral 4 (13.2 First Characteristic Numeral 4 :protected against solid foreign object of 1.0 mm dia and greater) |
7500.0 |
|
13.4/13.5 First Characteristic Numeral 5 (13.4/13.5 First Characteristic Numeral 5 : Dust Protected) |
7500.0 |
|
13.4/13.5 First Characteristic Numeral 6 (13.4/13.5 First Characteristic Numeral 6 : Dust - Tight) |
7500.0 |
|
14.2.1 Second Characteristic Numeral 1 (14.2.1 Second Characteristic Numeral 1 : Protected against vertically falling water drops) |
7500.0 |
|
14.2.2 Second Characteristic Numeral 2 (14.2.2 Second Characteristic Numeral 2 : Protection against vertically falling water drops when enclosure tilted upto 15 degree) |
7500.0 |
|
14.2.5 Second characteristic numeral 5 (14.2.5 Second characteristic numeral 5: Protected against Water Jet) |
7500.0 |
|
14.2.6 Second characteristic numeral 6 (14.2.6 Second characteristic numeral 6: Protected against powerful water Jet) |
7500.0 |
|
14.2.7, Second characteristic numeral 7 (14.2.7, Second characteristic numeral 7:Protected against the effects of temporary immersion in water) |
7500.0 |
|
14.2.8, Second Characteristic numeral 8 (14.2.8, Second Characteristic numeral 8: Protected against the effects of continuous immersion in water.
if water has entered, it shall not be sufficient to interfere with the correct operation of the equipment or impair safety.) |
7500.0 |
|
14.2.4 Second characteristic numeral 4 (14.2.4 Second characteristic numeral 4 with oscillating tube or spray nozzle) |
7500.0 |
|
14.2.3 second characteristic numeral 3 (14.2.3 second characteristic numeral 3:Protected against spraying water) |
7500.0 |
|
Drawing Verification (As per drawing with respect to dimension only and customer requirement) |
3000.0 |
|
|
962 |
IS/IEC : 60529 (2001 reaff : 2019) - Degree of Protection Provided by Enclosure(IP CODE) |
Degree of Protection Provided by Enclosure(IP CODE) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
13.2 First Characteristic Numeral 1 (Protection against solid foreign object of 50mm dia and greater,First Characteristic Numeral 1, cl 13.2) |
7500.0 |
|
13.2 First Characteristic Numeral 2 (First Characteristic Numeral 2,Protection against solid foreign objects of 12.5 mm dia and greater.) |
7500.0 |
|
13.2 First Characteristic Numeral 3 (First Characteristic Numeral 3, Protection against solid foreign objects of 2.5 mm dia and greater.) |
7500.0 |
|
13.2 First Characteristic Numeral 4 (Protection against solid foreign objects of 1.0 mm dia and greater,First Characteristic Numeral 4) |
7500.0 |
|
13.4/13.5 First Characteristic Numeral 5 (Dust Protected) |
7500.0 |
|
13.4/13.5 First Characteristic Numeral 6 (No ingress of Dust) |
7500.0 |
|
14.2.1 Second Characteristic Numeral 1 (Protected against vertically falling water drops) |
7500.0 |
|
14.2.2 Second Characteristic numeral 2 (Protection against vertically falling water drops when enclosure tilted upto 15 degree) |
7500.0 |
|
14.2.3 second characteristic numeral 3 (14.2.3 second characteristic numeral 3 :Protected against spring water) |
7500.0 |
|
14.2.4 Second characteristic numeral 4 (14.2.4 Second characteristic numeral 4 :Protected against splashing water) |
7500.0 |
|
14.2.5 Second characteristic numeral 5 (Protection against water Jets,14.2.5 Second characteristic numeral 5) |
7500.0 |
|
14.2.6 Second characteristic numeral 6 (14.2.6 Second characteristic numeral 6 : Protected against powerful Jet) |
7500.0 |
|
14.2.7, Second characteristic numeral 7 (14.2.7, Second characteristic numeral 7 :Protected against the effects of temporary immersion in water) |
7500.0 |
|
14.2.8, Second Characteristic numeral 8 (Protection against the effects of continuous immersion in water:14.2.8, Second Characteristic numeral 8) |
7500.0 |
|
Drawing Verification withe respect to dimension (Drawing Verification with respect to dimension) |
3000.0 |
|
|
963 |
IS 1730 (1989) - Dimensions for steel plates,sheets strips and flats for general engineering purposes |
Dimensions for steel plates,sheets strips and flats for general engineering purposes |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
4 (Length of Cover Plate) |
1000.0 |
|
5 (Thickness of Cover Plate) |
1000.0 |
|
6 (Width of Cover Plate) |
1000.0 |
|
7 (Thickness of Omega Clamp) |
1000.0 |
|
9 (Mass of Zinc Coating) |
2000.0 |
|
|
964 |
IS 2266 (2019) - Steel Wire Ropes for General Engineering Purpose |
Steel Wire Ropes for General Engineering Purpose |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
4 (Diameter) |
1000.0 |
|
5 (Breaking Force) |
3000.0 |
|
10 (Mass of Zinc Coating) |
2000.0 |
|
|
965 |
IS 1622 (1981) - Methods of sampling and microbiological examination or water (First Revision) |
Methods of sampling and microbiological examination or water (First Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
3.3 (Coliform) |
1000.0 |
|
|
966 |
IS 1835 (1976) - Round Steel Wire for Ropes |
Round Steel Wire for Ropes |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
5 (Chemical Analysis) |
4000.0 |
|
7 (Freedom from Defects) |
1000.0 |
|
10 (Diameter) |
1000.0 |
|
11.2 (Uniformity of Zinc Coating) |
2000.0 |
|
11.3 (Mass of Zinc Coating) |
2000.0 |
|
12.2 (Tensile Strength) |
3000.0 |
|
12.3 (Torsion Test) |
2000.0 |
|
12.5 (Wrapping Test) |
2000.0 |
|
|
967 |
OPTICAL FIBER CABLE - OPTICAL FIBER CABLE |
OPTICAL FIBER CABLE |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
4.1(i) (Transmission of Light Test of Fiber Cable) |
1000.0 |
|
4.1(h) (Overall Diameter of Jacket) |
500.0 |
|
4.1(g) (Colour of Jacket) |
500.0 |
|
4.1(f) (Any other Detail of fiber cable) |
500.0 |
|
4.1(e) (Mylar Fiber and Colour) |
500.0 |
|
4.1(d) (Colour of Sheath) |
500.0 |
|
4.1(c) (Individual Sheathed of Fiber Cable) |
8000.0 |
|
4.1(b) (Presence of Sheath/Covering in addition to coat on Fiber) |
500.0 |
|
4.1(a) (Nos of Fibers) |
1000.0 |
|
4 (Construction of Optical Fiber Cable) |
500.0 |
|
3 (Marking on Optical Fiber Cable) |
500.0 |
|
2 (Description of Optical Fiber Cable) |
500.0 |
|
1 (Marking) |
500.0 |
|
|
968 |
IS 16014 (2024) - Mechanically woven, double - Twisted, hexagonal wire mesh gabions, revet mattresses, rock fall netting and other products for civil engineering purposes (Galvanized Steel Wire Or Galvanized Steel Wire With Polymer Coating) - Specification (First Revision) |
Mechanically woven, double - Twisted, hexagonal wire mesh gabions, revet mattresses, rock fall netting and other products for civil engineering purposes (Galvanized Steel Wire Or Galvanized Steel Wire With Polymer Coating) - Specification (First Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
6.1 (Tensile Strength of Mesh Wire(Steel)) |
2000.0 |
|
6.1 (Elongation of Mesh Wire) |
1000.0 |
|
8 (Diameter of Mesh Wire without Polymer Coating) |
1000.0 |
|
7.1 (Mass of Zinc/Zinc Alloy Coating of Mesh Wire) |
2000.0 |
|
7.2 (Specific Gravity of Polymer Coating Material of Mesh Wire) |
1000.0 |
|
7.2 (Tensile Strength of Polymer Coating Material of Mesh Wire) |
1000.0 |
|
7.2 (Hardness of Polymer Coating Material of Mesh Wire) |
1000.0 |
|
8 (Diameter of Mesh Wire without Polymer Coating) |
1000.0 |
|
8 (Mesh Size) |
1000.0 |
|
8 (Thickness of Polymer Coating of Mesh Wire) |
1000.0 |
|
8 (Mesh Size) |
1000.0 |
|
8 (Diameter of Edge/Selvedge Wire without Polymer Coating) |
1000.0 |
|
8 (Diameter of Lacing Wire without Polymer Coating) |
500.0 |
|
8 (Diameter of Mesh Wire with Polymer Coating) |
500.0 |
|
8 (Size of Gabion Box/ Revet Mattress/ Reinforced Soil Structure (L x W x H)) |
1000.0 |
|
8 (Size of Sack Gabion (L x D)) |
1000.0 |
|
8 (Size of Rockfall Netting (L x W)) |
1000.0 |
|
6.1 (Tensile Strength of Edge/Selvedge Wire (steel)) |
2000.0 |
|
6.1 (Tensile Strength of Lacing Wire(steel)) |
2000.0 |
|
6.1 (Elongation of Edge/Selvedge Wire) |
1000.0 |
|
6.1 (Elongation of Lacing Wire) |
1000.0 |
|
7.1 (Mass of Zinc/Zinc Alloy Coating of Edge/Selvedge Wire) |
2000.0 |
|
7.1 (Mass of Zinc/Zinc Alloy Coating of Lacing Wire) |
2000.0 |
|
7.2 (Hardness of Polymer Coating Material of Edge/Selvedge Wire) |
1000.0 |
|
7.2 (Tensile Strength of Polymer Coating Material of Edge/Selvedge Wire) |
1000.0 |
|
7.2 (Tensile Strength of Polymer Coating Material of Lacing Wire) |
1000.0 |
|
7.2 (Specific Gravity of Polymer Coating Material of Edge/Selvedge Wire) |
1000.0 |
|
7.2 (Specific Gravity of Polymer Coating Material of Lacing Wire) |
1000.0 |
|
8 (Thickness of Polymer Coating of Edge/Selvedge Wire) |
1000.0 |
|
8 (Thickness of Polymer Coating of Lacing Wire) |
1000.0 |
|
8 (Diameter of Edge/Selvedge Wire with Polymer Coating) |
1000.0 |
|
7.2 (Hardness of Polymer Coating Material of Lacing Wire) |
1000.0 |
|
|
969 |
LP -01 (Emergency Light) - Testing of LED Emergency Light |
Testing of LED Emergency Light |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Total Luminous Flux (lm)) |
5000.0 |
|
|
970 |
IS 5493 (1981) - Dimensions for wrought copper and copper alloy tubes (First Revision) |
Dimensions for wrought copper and copper alloy tubes (First Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
2.1 (Out Side Diameter) |
1000.0 |
|
2.2 (Thickness) |
1000.0 |
|
2.3 (Roundness) |
1000.0 |
|
|
971 |
ICAO Annex 14 - On the lines of ICAO annexure 14(test for aviation obstruction light) |
On the lines of ICAO annexure 14(test for aviation obstruction light) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
A.1 (Peak Intensity (cd) in single-mode (non flashing mode)) |
10000.0 |
|
A.2 (Peak Intensity (cd) in dual mode (non flashing mode )) |
20000.0 |
|
|
972 |
IS-9537(Part-II)-1981 Reaff. 2017 - Conduits for Electrical Installations- Rigid Steel Conduits |
Conduits for Electrical Installations- Rigid Steel Conduits |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
5 (Classification) |
2000.0 |
|
6 (Marking) |
1000.0 |
|
7 (Dimensions) |
2000.0 |
|
9.2 (As per Specification) |
5000.0 |
|
9.3 (Compression Test as specification) |
5000.0 |
|
8 (Smoothness of inside and outside surface of Conduit) |
3000.0 |
|
|
973 |
Custom (0) - Cement Sand ratio |
Cement Sand ratio |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1. (Cement sand ratio) |
5000.0 |
|
|
974 |
IS 456-II (2000) - Plain and Reinforced Concrete - CONCRETE CHEMICAL [Custom] |
Plain and Reinforced Concrete - CONCRETE CHEMICAL |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
5.4.1.2 (Compressive strength of water sample) |
4000.0 |
|
5.4.1.3 (Setting time of water sample) |
2000.0 |
|
|
975 |
On the lines of ICAO Annexure 14 - Aviation Obstruction Light |
Aviation Obstruction Light |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Light Intensity ( cd)) |
10000.0 |
|
2 (Degree of Protection IP-6X ( Dust Tight) as per IS/IEC 60529) |
6000.0 |
|
3 (Degree of Protection IP-X5 ( Protection against Water Jet as per IS/IEC 60529)) |
6000.0 |
|
|
976 |
IS 516 : Part 1 : Sec 1 (2021) - Hardened concrete methods of test part 1 testing of strength of hardened concrete section 1 compressive,flexucal and split tensile strength (First Revision) |
Hardened concrete methods of test part 1 testing of strength of hardened concrete section 1 compressive,flexucal and split tensile strength (First Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
3 (Compressive Strength of CC Cube 1 set IS 516 (Part1)/Sec1:2021) |
1200.0 |
|
|
977 |
IS 9000 : Part 8 (1981) - Basic environmental testing procedures for electronic and electrical items: Part 8 vibration (Sinusoidal) test |
Basic environmental testing procedures for electronic and electrical items: Part 8 vibration (Sinusoidal) test |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
NA (Frequency Range : 5 Upto 3000Hz) |
15000.0 |
|
|
978 |
5154 - Lead Acid Traction Battery |
Lead Acid Traction Battery |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
3 (Dimensions) |
500.0 |
|
4 (Marking and polarity) |
500.0 |
|
3.1 (Test For Capacity) |
10000.0 |
|
3.4 (Cyclic Endurance Test) |
50000.0 |
|
3.2 (Test for retention of Charge) |
20000.0 |
|
3.3 (High Rate Discharge) |
20000.0 |
|
|
979 |
IS 15622 (2017) - Pressed Ceramic Tiles - Specification (First Revision) |
Pressed Ceramic Tiles - Specification (First Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
6, Tables 5 to 9, Sl No (ii), (e) (Scratch Hardness of surface (Mohs' Scale)-IS13630 (Part 13):2019) |
2000.0 |
|
6, Tables 5 to 9, Sl No (ii), (c) (Breaking of strength in N- IS13630 (Part 6):2019) |
2000.0 |
|
6, Tables 8 and 9, Sl No (ii), (q) (Bulk Density-IS13630 (Part 2):2019) |
1000.0 |
|
6, Tables 5 to 9, Sl No (ii), (b) (Modulus of rupture in N/mm²- IS13630 (Part6):2019) |
2000.0 |
|
6, Tables 5 to 9, Sl No (ii), (a) (Water Absorption-IS13630 (Part 2):2019) |
1000.0 |
|
6, Tables 5 to 9, Sl No (i), (e-1,2,3) (Surface Flatness-Maximum deviation in percent from flatness-(Centre curvature, Edge curvature & warpage) -IS: 13630 (Part1):2019) |
500.0 |
|
6, Tables 5 to 9, Sl No (i), (c) (Straightness of sides(Facial sides)Maximum deviation in percent to corresponding work size- IS13630 (Part1):2019) |
500.0 |
|
6, Tables 5 to 9, Sl No (i), (d) (Rectangularity-Maximum deviation in percent to corresponding work size-IS: 13630 (Part1):2019) |
500.0 |
|
6, Tables 5 to 9, Sl No (i), (b) (Dimension-Thickness-Deviation in percent from work size -IS: 13630 (Part1):2019) |
1000.0 |
|
6, Tables 5 to 9, Sl No (i), (a) (Dimensions-Width -IS:13630 (Part1):2019) |
1000.0 |
|
6, Tables 5 to 9, Sl No (i), (a) (Dimensions-Length-IS13630 (Part1):2019) |
1000.0 |
|
6, Tables 5 to 9, Sl No (iii), (a) (Resistance to staining IS 13630(8)/(7):2019) |
1000.0 |
|
6. iii)b (Resistance to household chemicals and swimming pool water cleansers except HF and its compounds) |
1500.0 |
|
6. iii)a (Resistance to acids and alkalis(with the exceptions of HF & its compounds)) |
1000.0 |
|
6.ii) k (Impact resistance-Co-efficient of restitution (on the lines of IS 13630(14):2019)) |
1000.0 |
|
|
980 |
IRS S 88 (2004) - Low maintenance Lead Acid Stationary Secondary Cells for S&T Installation |
Low maintenance Lead Acid Stationary Secondary Cells for S&T Installation |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
7.2 (Verifiational of Constructional requirements) |
20000.0 |
|
7.3 (Verification of Marking and packing) |
500.0 |
|
7.4 (Dimensions) |
500.0 |
|
7.5 (Capacity in Ah) |
20000.0 |
|
7.6 (Test for Loss of Capacity on storage in Ah) |
20000.0 |
|
7.7 (Endurance Test) |
90000.0 |
|
7.8 (Ampere-hour and watt hour efficiency test) |
20000.0 |
|
7.9 (Test for Voltage during discharge in Ah) |
1000.0 |
|
7.10 (Life Test total 1100 cycle) |
100000.0 |
|
7.11 (Storage Test for 2 years) |
20000.0 |
|
7.12 (Water Loss Test) |
10000.0 |
|
7.13 (Equilibrium Float Current Test) |
20000.0 |
|
7.14 (Sulphation Test) |
20000.0 |
|
7.15 (Air Pressure Test) |
10000.0 |
|
|
981 |
AS 1397 (2021) - Continuous hot-dip metallic coated steel sheet and strip - Coatings of zinc and zinc alloyed with aluminium and magnesium |
Continuous hot-dip metallic coated steel sheet and strip - Coatings of zinc and zinc alloyed with aluminium and magnesium |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
3.4 (Both surface -Triple spot) |
2000.0 |
|
3.2 (One surface- Single spot) |
2000.0 |
|
2.2 (Sulfur) |
500.0 |
|
2.2 (Carbon) |
500.0 |
|
2.2 (Phosphorus) |
500.0 |
|
2.2 (Mangnese) |
500.0 |
|
2.3 (Tensile strength) |
1000.0 |
|
2.3 (Yield Stress) |
1000.0 |
|
2.3 (% Elongation) |
1000.0 |
|
2.5.1 (Total Coated Thickness) |
1000.0 |
|
2.5 (Base Metal Thickness) |
1000.0 |
|
3.3 (Coating Adherence Test) |
1000.0 |
|
2.4 (Bend Test) |
1000.0 |
|
2.5 (Base Metal Thickness) |
1000.0 |
|
3.3 (Coating Adherence Test) |
1000.0 |
|
2.4 (Bend Test) |
1000.0 |
|
|
982 |
MORTH : Part 5 (2013) - SPECIFICATIONS FOR ROAD AND BRIDGE WORKS/ASTM |
SPECIFICATIONS FOR ROAD AND BRIDGE WORKS/ASTM |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
983 |
EIL B224-000-79-41-PLS-01 : Part 5 (2019) - Job specification for surface preparation and protective coating |
Job specification for surface preparation and protective coating |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
984 |
IEC 60896 : Part 21-22 (2004) - Stationary Lead Acid Batteries Valve Regulated Type |
Stationary Lead Acid Batteries Valve Regulated Type |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
6.1 (Gas Emission Test) |
30000.0 |
|
6.2 (High Current tolerance Test) |
20000.0 |
|
6.6 (Content and durability of required marking) |
500.0 |
|
6.7 (Material Identification) |
3000.0 |
|
6.11 (Discharge Capacity) |
60000.0 |
|
6.12 (Charge retention during Storage) |
50000.0 |
|
6.13 (Float Service with daily discharges) |
30000.0 |
|
6.14 (Recharge behaviour) |
30000.0 |
|
6.15 (Service Life at an operating temp. at 40 Deg C) |
300000.0 |
|
6.16 (Impact of a stress temperature of 50Deg C or 60 Deg C) |
250000.0 |
|
6.17 (Abusive over discharge) |
60000.0 |
|
6.19 (Low temperature sensitivity) |
30000.0 |
|
|
985 |
IS 13252 (2010) - Information Technology Equipments, Class I Product |
Information Technology Equipments, Class I Product |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
2.1.1.6 (Manual Controls) |
2000.0 |
|
2.3.3 (Separations from Hazardous Voltages) |
1000.0 |
|
2.5 (Limited Power Source) |
1000.0 |
|
2.6 (Protective earthing Conductors and protective bonding Conductors) |
2000.0 |
|
2.7 (Over Current and earth fault protection primary Circuit) |
1000.0 |
|
2.8 (Protection requirements for safety interlocks) |
500.0 |
|
2.9 (Humidity Condition) |
10000.0 |
|
2.10.2 (Determination of Working Voltage) |
1000.0 |
|
3 (Wiring Connection and Supplies) |
1000.0 |
|
4.2.1,4.2.2,4.2.3,4.2.4 (Steady force Test) |
1000.0 |
|
4.2.5 (Impact Test Apparatus) |
500.0 |
|
4.2.6 (Drop Test) |
1000.0 |
|
4.2.7 (Stress Relief Test) |
1000.0 |
|
4.3.1 (Edges and corners) |
500.0 |
|
4.3.4 (Securing of Parts) |
500.0 |
|
4.3.6 (Direct Plug in Equipment) |
1000.0 |
|
4.3.8 (Batteries) |
1000.0 |
|
4.3.9 (Oil & Grease) |
500.0 |
|
4.4.2 (Protected in operator access area) |
1000.0 |
|
4.4.3 (Protected in restricted access Location) |
1000.0 |
|
4.4.4 (Protected in service access Location) |
1000.0 |
|
4.5.2. (Temperature Test) |
1000.0 |
|
4.5.3. (Temperature Limits for Materials) |
2000.0 |
|
4.5.4. (Touch Temperature Limits) |
1000.0 |
|
4.5.5. (Resistance to abnormal Heat) |
2000.0 |
|
4.6.3,4.6.4,4.6.4.1,4.6.4.2,4.6.4.3 (Top, Bottom and Side Opening) |
500.0 |
|
4.6.5 (Adhesives for Constructional Purposes) |
500.0 |
|
5.2 (Electric Strength) |
5000.0 |
|
6.1.1,6.1.2 (Protection of Telecommunication network service person and user to network Protection from Hazardous Voltages) |
1000.0 |
|
6.2.1 (Protection of equipments user from overvoltage on Telecommunication network) |
1000.0 |
|
6.2.2 (Electrical Strength Test) |
2000.0 |
|
6.3 (Protection of the Telecommunication wiring system from over heating) |
2000.0 |
|
7.2 (Protection of cable distribution system service persons and user of other equipment connected to the system from hazardous voltage in the equipment) |
2000.0 |
|
7.3 (Protection of equipment user from over voltages on the cable distribution) |
1000.0 |
|
4.7.2,4.7.2.1,4.7.2.2 (Resistance to force (Reducing the risk of ignition and spread of flame)) |
1000.0 |
|
IS 13252 (PART 1) (Neutral conductor) |
500.0 |
|
IS 13252 (PART 1) (Voltage Limit of Hand held equipment) |
500.0 |
|
IS 13252 (PART 1) (Voltage Surge Test) |
2000.0 |
|
2.1.1.8 (Energy Hazard DC Mains Supply) |
1000.0 |
|
|
986 |
IS 616 (2017) - Audio, video and similar electronic apparatus - Safety requirements (Fifth Revision) |
Audio, video and similar electronic apparatus - Safety requirements (Fifth Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
5 (Marking & Instructions) |
500.0 |
|
7.1.1 (Heating under normal Operating Conditions, Accessible parts) |
5000.0 |
|
7.1.3 (Parts other than windings, providing Electrical Insulation) |
1000.0 |
|
7.1.4 (Parts acting as a support or a mechanical barrier & Winding) |
1000.0 |
|
7.2 (Heat Resistance of insulating Material) |
1000.0 |
|
8.1 to 8.16 (Constructional Requirements with regard to the Protection against Electrical Shock) |
1000.0 |
|
8.17 (Requirement of Insulating winding wires for use without additional interleaved insulation) |
500.0 |
|
8.18 (Endurance Test for wound components with insulated winding wires without additional interleaved insulation) |
500.0 |
|
8.19.1,&8..19.2 (Disconnection from the mains) |
1000.0 |
|
8.20 & 8.21 (Main Switch) |
500.0 |
|
9.1.2 & 9.1.3 (Shafts of operating, Knobs , handles, levers and the like) |
500.0 |
|
9.1.4 (Terminals) |
500.0 |
|
9.1.5 (Preset Controls) |
1000.0 |
|
9.1.6 (Withdrawal of main Plugs) |
1000.0 |
|
9.1.7 (Resistance to external s-force) |
1000.0 |
|
9.2 (Removal of protective cover) |
500.0 |
|
10.2 (Surge Test) |
10000.0 |
|
10.3 (humidity Treatment) |
20000.0 |
|
10.4 (Insulation Resistance and Dielectric Strength) |
500.0 |
|
11.1 (Electrical Shock Hazard) |
500.0 |
|
11.2,11.2.1, 11.2.2,11.2.3,11.2.4,11.2.5, (Heating) |
3000.0 |
|
12.1.3 (Vibration Test) |
5000.0 |
|
12.1.4 (Impact Test) |
500.0 |
|
12.1.5 (Drop Test) |
500.0 |
|
12.1.6 (Stress Relief Test) |
500.0 |
|
12.2 (Fixing of actuating Elements) |
1000.0 |
|
12.3 (Remote Control devices held in hand) |
500.0 |
|
|
987 |
IS 1652 (2013) - Stationary cells and batteries, lead - Acid type with plante positive plates - Specification (Fourth Revision) |
Stationary cells and batteries, lead - Acid type with plante positive plates - Specification (Fourth Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
5 (Verification of Constructional Requirements) |
5000.0 |
|
7 (Verification of Marking) |
2000.0 |
|
6.1 (Verification of Dimensions) |
3000.0 |
|
10.6 (Test for Capacity) |
25000.0 |
|
10.11 (Test for Voltage during Discharge) |
10000.0 |
|
10.10 (Ampere-hour and watt hour efficiency test) |
10000.0 |
|
10.8 (Test for loss of Capacity on Storage) |
10000.0 |
|
10.9 (Endurance Test) |
90000.0 |
|
10.12 (Loss of water test) |
10000.0 |
|
10.13 (Test for suitability of floating battery operation) |
10000.0 |
|
10.14 (Short circuit & Internal Resistance Test) |
15000.0 |
|
|
988 |
IS 6304 (1992) - Stationary batteries - Lead - Acid type - With pasted positive plates - Specification (Second Revision) |
Stationary batteries - Lead - Acid type - With pasted positive plates - Specification (Second Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
4.3,4.4,4.6,,4.8,4.9,4.10 &7 (Visual Inspection) |
10000.0 |
|
4.1,4.2,4.5,4.7&4.11 (Physical Verification) |
25000.0 |
|
6 (Physical Verification) |
500.0 |
|
8.6 (Capacity) |
20000.0 |
|
8.7 (Capacity) |
10000.0 |
|
8.8.1 (Ampere- Hour Efficiency) |
7500.0 |
|
8.8.2 (Watt Hour Efficiency) |
7500.0 |
|
8.9 (Capacity) |
45000.0 |
|
8.1 (Voltage during Discharge) |
5000.0 |
|
9.8 (Voltage) |
10000.0 |
|
|
989 |
IS 14257 (2019) - Lead - Acid storage batteries for motor vehicles with light weight and high cranking performance - Specification (First Revision) |
Lead - Acid storage batteries for motor vehicles with light weight and high cranking performance - Specification (First Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
9.3.1 (Physical Examination) |
20000.0 |
|
9.3.2 (Dimensions and layout) |
500.0 |
|
9.3.3 (Marking) |
500.0 |
|
9.3.4 (5-hr capacity Test) |
20000.0 |
|
9.3.5 (High rate discharge test at -15℃) |
20000.0 |
|
9.3.6 (Cold cranking Ampere at -18℃) |
20000.0 |
|
9.3.7 (Reserve Capacity Test) |
20000.0 |
|
9.3.8 (Charge Acceptance test) |
15000.0 |
|
9.3.9 (water loss in percent) |
10000.0 |
|
9.3.10 (Charge retention test) |
5000.0 |
|
9.3.11 (Light load Endurance test) |
30000.0 |
|
9.3.12 (Life cycle test) |
50000.0 |
|
9.3.13 (Over-charge Endurance test) |
5000.0 |
|
9.3.14 (Electrolyte retention test) |
5000.0 |
|
9.3.15 (Vibration resistance test) |
10000.0 |
|
9.3.16 (Strength of terminal test) |
5000.0 |
|
9.3.17 (Robustness to fastening test) |
5000.0 |
|
Annex. B-1.2 (Residual Capacity Test) |
10000.0 |
|
|
990 |
IS 16270 (2014) - Secondary cells and batteries for solar photovoltaic application - General requirements and methods of test |
Secondary cells and batteries for solar photovoltaic application - General requirements and methods of test |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
8.1 (Rated Capacity) |
20000.0 |
|
8.2 (Endurance Test) |
80000.0 |
|
8.3 (Charge retention test) |
10000.0 |
|
8.4 (Cycling Endurance in photovoltaic application( Extreme Conditions)) |
90000.0 |
|
8.5 (Recovery from sulphation Test) |
10000.0 |
|
8.6 (Water loss Test) |
10000.0 |
|
|