451 |
ND Custom 7 (2023) - Sample of B-150 type OHE traction mast (Galvanized fabricated structure) |
Sample of B-150 type OHE traction mast (Galvanized fabricated structure) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Mass of Zinc Coating as per IS 6745) |
2000.0 |
|
2 (Zn Coating Thickness as per IS:3203 (1982)) |
2000.0 |
|
|
452 |
RDSO 153 (2011) - RDSO/SPN/153/2011 REVISION 4.1 (FOR LED SIGNAL LIGHTING UNIT) |
RDSO/SPN/153/2011 REVISION 4.1 (FOR LED SIGNAL LIGHTING UNIT) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
9.1.(ii) (Colour Co- Ordinates, Clause 9.1.(ii)) |
5000.0 |
|
Clause 5.2, 7.3 (Operating parameters ,Clause 5.2, 7.3 of RSDO/SPN/153/2011, Rev 4.1) |
5000.0 |
|
Clause 9.1 (vii) (Climatic Test Change in Temperature , Clause 9.1 (vii)) |
10000.0 |
|
Clause 9.1 (vii) (Climatic Test (Dry Heat Test) as per RDSO/SPN/153/2011, Rev 4.1) |
10000.0 |
|
,Clause 9.1 (vii) (Climatic ( Cold Test),Clause 9.1 (vii) as per RDSO/SPN/153/2011, REV- 4.1) |
10000.0 |
|
Clause 9.1 (vii) (Climatic ( Damp Heat Test Cyclic) ,Clause 9.1 (vii) as per RDSO/SPN/153/2011, Rev 4.1) |
10000.0 |
|
Clause 9.1 (vii) (Climatic Test ( Damp Heat Steady State) , Clause 9.1 (vii) as per RDSO/SPN/153/2011, Rev 4.1) |
25000.0 |
|
Clause 9.1 (vii) (Climatic Test ( Salt Mist) , Clause 9.1 (vii) as per RDSO/SPN/153/2011, Rev 4.1) |
10000.0 |
|
Clause 9.1 (vii) (Climatic Test ( Dust Test) , Clause 9.1 (vii) as per RDSO/SPN/153/2011, Rev 4.1) |
7500.0 |
|
Clause 9.1 (vii) (Climatic Test ( Water Immersion Test) , Clause 9.1 (vii) as per RDSO/SPN/153/2011, Rev 4.1) |
7500.0 |
|
Clause 9.1 (vii) (Climatic Test ( Driving Rain) , Clause 9.1 (vii) as per RDSO/SPN/153/2011, Rev 4.1) |
5000.0 |
|
Clause 9.1 (vii) (Climatic Test ( Shock Test ) , Clause 9.1 (vii) as per RDSO/SPN/153/2011, Rev 4.1) |
10000.0 |
|
Clause 9.1 (vii) (Climatic Test ( Vibration Test ) , Clause 9.1 (vii) as per RDSO/SPN/153/2011, Rev 4.1) |
15000.0 |
|
Clause 9.1 (vii) (Climatic Test (Thermal Cycling)Clause 9.1 (vii) of RDSO/SPN/153/2011 Rev 4.1) |
10000.0 |
|
Clause 9.1(xii) (Applied High Voltage Test ,Clause 9.1(xii) of RDSO/SPN/153/2011, Rev 4.1) |
3000.0 |
|
,Clause 9.1(xiii) (Insulation resistance Test ,Clause 9.1(xiii) of RDSO/SPN/153/2011, Rev 4.1) |
2000.0 |
|
Clause 9.1(xiv) (Minimum Lighting Voltage ,Clause 9.1(xiv) of RDSO/SPN/153/2011, Rev 4.1) |
2000.0 |
|
|
453 |
RDSO Standard STR No. C-8217 (Rev-1) - SCHEDULE Of" REQUIREMENTS FOR ALUMINIUM CHEQUERED SHEETS FOR USE AS FLOORING MATERIAL ON COACHING STOCK" (SUPERSEDES C-8217) . |
SCHEDULE Of" REQUIREMENTS FOR ALUMINIUM CHEQUERED SHEETS FOR USE AS FLOORING MATERIAL ON COACHING STOCK" (SUPERSEDES C-8217) . |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
4.2 (Dimension) |
1000.0 |
|
7.2 (Tensile Strength) |
2000.0 |
|
7.2 (0.2% Proof stress) |
1000.0 |
|
7.2 (Elongation) |
1000.0 |
|
7.2 (Bend Test) |
1500.0 |
|
4.1.2 (Chemical Composition of the material shall be as per IS 737:1986, Designation 65032) |
4500.0 |
|
|
454 |
CUSTOM/ILPT/2023 - CUSTOM/ILPT/2023 |
CUSTOM/ILPT/2023 |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1.0 (Full Belt Breaking Force(Warp)) |
- |
|
2.0 (Full Belt Elongation at Break) |
1000.0 |
|
3.0 (Full Belt Elongation at Ref. load(10 % FB)) |
- |
|
4.0 (Full Belt Breaking Force(Weft)) |
- |
|
|
455 |
CUSTOM - LOW SULPHUR HAVVY STOCK OIL |
LOW SULPHUR HAVVY STOCK OIL |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (POUR POINT) |
1200.0 |
|
2 (DENSITY AT 15 Dg C) |
1200.0 |
|
3 (KINEMATIC VISCOCITY) |
1200.0 |
|
|
456 |
Custom - Purity of Silicon |
Purity of Silicon |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Purity of Silicon) |
2000.0 |
|
|
457 |
RDSO/SPN/176/2013 (2014) - MULTI SECTION DIGITAL AXLE COUNTER |
MULTI SECTION DIGITAL AXLE COUNTER |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
11.5.5.1 (Change of Temperature Test) |
15000.0 |
|
11.5.5.2 (Dry Heat test) |
10000.0 |
|
11.5.5.3 (Cold test) |
10000.0 |
|
11.5.5.4 (Damp Heat Test (Cyclic)) |
35000.0 |
|
11.5.5.5 (Damp Heat Test (Steady state)) |
25000.0 |
|
11.5.8 (Vibration Test) |
15000.0 |
|
11.5.5.6 (Salt Mist Test) |
5000.0 |
|
11.5.5.7 (Driving Rain Test) |
15000.0 |
|
11.5.5.8 (Water Immersion Test) |
15000.0 |
|
11.5.5.9 (Dust Test) |
15000.0 |
|
11.5.4 (Insulation Resistance Test) |
18000.0 |
|
11.5.3 (Applied High Voltage Test) |
2000.0 |
|
|
458 |
Custom - Bitumen content DBM ,BM & BC |
Bitumen content DBM ,BM & BC |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Bitumen Content in DBM) |
3000.0 |
|
2 (Bitumen Content in BC) |
3000.0 |
|
|
459 |
3328:1993 - QUALITYTOLERANCES FOR WATER FOR SWIMMING POOLS |
QUALITYTOLERANCES FOR WATER FOR SWIMMING POOLS |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (pH value) |
1200.0 |
|
2 (Total Alkalinity (as CaCO3) mg/l) |
1200.0 |
|
3 (Aluminium (as Al) mg/l) |
1200.0 |
|
6 (Total Dissolved Solids, mg/l) |
1200.0 |
|
7 (Chloride (as Cl)) |
1200.0 |
|
8 (Iron) |
1200.0 |
|
9 (Heavy metals (as Pb)) |
1200.0 |
|
10 (Colour , Hazen Units) |
1200.0 |
|
11 (Turbidity, NTU) |
1200.0 |
|
12 (Odour) |
1200.0 |
|
13 (Taste) |
1200.0 |
|
3.3.2 (Coliform Organisms) |
1200.0 |
|
|
460 |
RDSO/SPN/176/2013 Ver 3.0 date Effective 31.03.2014 (2014) - Specification for Multi Section Digital Axle Counter |
Specification for Multi Section Digital Axle Counter |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
11.5.5.1 (Change of temperature test as per , clause 11.5.5.1 of RDSO/SPN/176/2013 Version 3) |
12000.0 |
|
11.5.5.2 (Dry Heat Test as per IS 9000/Pt-III, Sec-5, clause 11.5.5.2 of RDSO/SPN/176/2013 Version 3) |
12000.0 |
|
11.5.5.3 (Cold Test as per IS 9000/Pt-II, Sec- 3, clause 11.5.5.3 of RDSO/SPN/176/2013 Version 3) |
15000.0 |
|
11.5.5.4 (Damp Heat Test (Cyclic) as per IS 9000/Pt-V, , Sec 2 ,Clause 11.5.5.4 of RDSO/SPN/176/2013 Version 3) |
20000.0 |
|
11.5.5.5 (Damp Heat Test (Steady State) as per IS 9000/Pt-IV, Clause 11.5.5.5 of RDSO/SPN/176/2013 Version 3) |
27000.0 |
|
11.5.8 (Vibration Test As per IS 9000( Part VIII) Clause 11.5.8 of RDSO/SPN/176/2013 Version 3) |
15000.0 |
|
11.5.5.6 (Salt Mist Test, Clause 11.5.5.6, Test as per RDSO/SPN/144) |
15000.0 |
|
11.5.5.7 (Driving Rain Test ( For Axial Detector), Clause 11.5.5.7 of IS 9000 PT XVI
Shall Comply the requirements of IP-66) |
10000.0 |
|
11.5.5.8 (Water Immersion Test ( For Axial Detectors) clause 11.5.5.8 of RDSO/SPN/176/2013 and test as per IS : 9000, PT-XV/Section 7 shall comply the requirements of IP-68
After the test, sample shall be measure insulation resistance shall not be less than 10 Mega Ohms.) |
10000.0 |
|
11.5.5.9 of RDSO/SPN/176/2013, Version -3.0 (Dust Test as per IS : 9000, Part-XII. and requirement shall comply IP-60) |
15000.0 |
|
11.5.5.5 (Damp Heat Test(Steady State) as per IS : 9000/PT-IV and Clause 11.5.5.5 of RDSO/SPN/176/2013, Ver -3) |
27000.0 |
|
11.5.5.4 (Clause 11.5.5.4, of RDSO/SPN/176/2013,version 3, Damp Heat Test ( Cyclic) as per IS-9000/Pt.V, Sec-2) |
30000.0 |
|
11.5.5.3 (Cold Test , Clause No. 11.5.5.3 of RSDO/SPN/176/2013,version 3, and as per IS 9000/Part II Sec 3
Temp : -10 Deg C +2/-2 Deg C duration 2 Hrs) |
6000.0 |
|
11.5.5.2 (Dry Heat Test , Clause No. 11.5.5.2 of RSDO/SPN/176/2013,version 3, and as per IS 9000/Part III Sec 5
Temp : +70 Deg C +2/-2 Deg C duration 16 Hrs) |
10000.0 |
|
11.5.4 (Insulation Resistance Test as per Clause 11.5.4 of IDSO/SPN/176/2013, Ver 3) |
6000.0 |
|
11.5.3 (Applied High Voltage Test as per Clause 11.5.3 of RDSO/SPN/176/2013, Ve. 3) |
5000.0 |
|
11.8.8 (Vibration Test as per RSDO/SPN/176/2013, Ver. 3 and IS : 9000, Part -VIII
Frequency : 10 Hz to 55 Hz
Amp : 0.35 to to peak or 5 g
Nos of axis:3
Nos of sweep cycle :20
Duration :1 Hrs 45 Min) |
15000.0 |
|
|
461 |
NTHER-Calibration of Standard Capacitor - Calibration of Standard Capacitor |
Calibration of Standard Capacitor |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
A1 (Calibration of Capacitance) |
1500.0 |
|
|
462 |
IS 14223 : Part 1 (1995) - Polished Building Stones: Part 1 Granite |
Polished Building Stones: Part 1 Granite |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
5 (Resistance to wear) |
4000.0 |
|
5 (Hardness) |
2000.0 |
|
5 (Ultrasonic pulse velocity) |
5000.0 |
|
5 (Shear strength) |
2000.0 |
|
5 (Tensile strength) |
2000.0 |
|
5 (Porosity) |
1000.0 |
|
5 (Water absorption) |
1000.0 |
|
5 (Compressive strength) |
2000.0 |
|
5 (Specific gravity) |
1000.0 |
|
5 (Dry density ) |
1000.0 |
|
5 (Moisture content) |
500.0 |
|
4 (Dimensions) |
500.0 |
|
|
463 |
IS 3316 (1974) - Structural Granite |
Structural Granite |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
3.3 (Water Absorption) |
1000.0 |
|
3.2 (Specific Gravity) |
1000.0 |
|
3.1 (Compressive Strength) |
2000.0 |
|
|
464 |
IS 1125 (1974) - Natural Building Stone |
Natural Building Stone |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
465 |
IEC 61427-1: 2013 (2013) - Secondary cells and batteries for renewable energy storage - General requirements and methods of test-
Part 1: Photovoltaic off-grid application |
Secondary cells and batteries for renewable energy storage - General requirements and methods of test-
Part 1: Photovoltaic off-grid application |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
8.1 (Capacity Test) |
60000.0 |
|
8.3 (Charge retension test) |
25000.0 |
|
8.4 (Cycling endurance test in photovoltaic applications(extreme conditions)) |
70000.0 |
|
|
466 |
IS 5154(Part 1 & 2): 2013 (2013) - Lead Acid Traction Batteries |
Lead Acid Traction Batteries |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
5.2 of IS 5154(Part-1)-2013 (5 h Capacity Test) |
25000.0 |
|
5.5 of IS 5154 (Part-1)-2013 (Cyclic Endurance Test) |
90000.0 |
|
3 and 5 of IS 5154(Part-2)-2013 (Dimensions of Traction Batteries) |
1000.0 |
|
5.4 (1 h High rate discharge performance test) |
15000.0 |
|
5.3 (Charge retention test) |
20000.0 |
|
|
467 |
Custom-32-ER-LM - Load Testing of Mounting Fixtures |
Load Testing of Mounting Fixtures |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Load Testing of the Mounting Fixture for 72Hours) |
15000.0 |
|
|
468 |
IEC 61439-1: 2009 & IS/IEC:60529-2001 - IP-65 Class of protection test
Drawing Verification
Power Frequency Voltage withstand test before and after IP test
Dielectric Properties test before and after IP test |
IP-65 Class of protection test
Drawing Verification
Power Frequency Voltage withstand test before and after IP test
Dielectric Properties test before and after IP test |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (IP-65 Class of Protection test) |
15000.0 |
|
2 (Drawing verification) |
3000.0 |
|
3 (Power frequency voltage withstand test) |
5000.0 |
|
4 (Di-electric properties test) |
5000.0 |
|
|
469 |
IS/IEC:60529-2001 & IEC 61439-1: 2009 - IP-42 Class of protection test
Drawing Verification
Power Frequency Voltage withstand test after IP test
Dielectric Properties test after IP test |
IP-42 Class of protection test
Drawing Verification
Power Frequency Voltage withstand test after IP test
Dielectric Properties test after IP test |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (IP-42 Class of protection test) |
15000.0 |
|
2 (Drawing verification) |
3000.0 |
|
3 (Power Frequency voltage withstand test) |
2500.0 |
|
4 (Di-electric Properties test) |
5000.0 |
|
|
470 |
JSG 0102:1984 - JOINT SERVICES GUIDE ON ENVIRONMENTAL TESTING ON ARMAMENT STORES |
JOINT SERVICES GUIDE ON ENVIRONMENTAL TESTING ON ARMAMENT STORES |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
As per specification & customer requirements (Discrete Tests) |
65000.0 |
|
|
471 |
IS 1708(Parts 1-18)1986: RA 2020 - METHODS OF TESTING OF SMALL CLEAR SPECIMENS OF TIMBER |
METHODS OF TESTING OF SMALL CLEAR SPECIMENS OF TIMBER |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Moisture content (IS 1708(1):1986)) |
1000.0 |
|
2 (Specific gravity (IS 1708(2):1986)) |
500.0 |
|
3 (Volumetric Shrinkage (IS 1708(3)1986)) |
1000.0 |
|
5 (Static bending strength (IS 1708(5):1986)
1.Fibre stress at limit of proportionality(FS at LP)
2.Equivalent fibre stress at maximum load(MOR)
3.Modulus of Elasticity( M of E)
4.Horizontal shear(HS)stress on neutral plan at LP
5.Horizontal shear stress at maximum load(ML)
6.Wk to LP
7.Wk to ML) |
3000.0 |
|
15 (Nail and Screw holding power(IS 1708(15):1986)) |
3000.0 |
|
8 (Compressive strength-Parallel to grain(IS 1708(8)1986)) |
1500.0 |
|
9 (Compressive strength-Perpendicular to grain(IS 1708(9):1986)) |
1500.0 |
|
12 (Tensile strength -Parallel to grain(IS 1708(12):1986)) |
2000.0 |
|
|
472 |
AMS 2630B (1995) - AEROSPACE MATERIAL SPECIFICATION |
AEROSPACE MATERIAL SPECIFICATION |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
4.1.1 (Ultrasonic Testing) |
2000.0 |
|
|
473 |
NTH ER HIGH POLYMER LAB (2022) - GLORIA BLUE Color
L*A*B* value testing using D65 light Source |
GLORIA BLUE Color
L*A*B* value testing using D65 light Source |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (GLORIA BLUE Color
L*A*B* value testing using D65 light Source) |
10000.0 |
|
|
474 |
ND Custom 6 (2023) - Aluminium and Aluminium Alloy Plates |
Aluminium and Aluminium Alloy Plates |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Tensile and Bend Test) |
4500.0 |
|
|
475 |
IS 398 : Part 5 (1992) - Aluminium conductor for overhead transmission purposes - Specification: Part 5 aluminium conductors - Galvanized steel - Reinforced for extra high voltage (400 KV And Above) (First Revision) |
Aluminium conductor for overhead transmission purposes - Specification: Part 5 aluminium conductors - Galvanized steel - Reinforced for extra high voltage (400 KV And Above) (First Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
13.3 (Measurement of Diameters of Individual Aluminium and Steel Wires) |
1000.0 |
|
13.4 (Measurement of Lay Ratio) |
2000.0 |
|
13.5.2 (Breaking Load Test on Individual Wires) |
3500.0 |
|
13.6 (Ductility Test) |
3500.0 |
|
13.7 (Wrapping Test) |
1000.0 |
|
13.8 (Resistance Test) |
5000.0 |
|
13.9 (Galvanizing Test) |
2000.0 |
|
|
476 |
IS 398 : Part 2 (1996) - Aluminium conductors for overhead transmission purposes - Specification: Part 2 aluminium conuuctors, galvanized steel - Reinforced (Third Revision) |
Aluminium conductors for overhead transmission purposes - Specification: Part 2 aluminium conuuctors, galvanized steel - Reinforced (Third Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
13.2 (Measurement of diameter of individual Aluminium wires (7 wire construction)) |
1000.0 |
|
13.3 (Breaking load of individual Aluminium wires (7 wire construction)) |
3500.0 |
|
13.4.1 (Ductility test-Torsion test on steel wires (7 Wire construction)) |
3500.0 |
|
13.5 (Wrapping test on Aluminium and Steel wires (7 wire construction)) |
1000.0 |
|
13.6 (Resistance of Aluminium wire (7 wire construction)) |
5000.0 |
|
13.8 (Measurement of lay ratio(7 wire construction)) |
2000.0 |
|
13.7(1) (Galvanizing test-Mass of zinc coating(7wire construction)) |
2000.0 |
|
|
477 |
AWWA C222-18 (2018) - Polyurethane Coatings and Linings for Steel Water Pipe and Fittings |
Polyurethane Coatings and Linings for Steel Water Pipe and Fittings |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
Prequalification requirements of polyurethane system (Appearance) |
1000.0 |
|
Prequalification requirements of polyurethane system (Electrical continuity inspection(Holiday test)) |
3500.0 |
|
Prequalification requirements of polyurethane system (Dry film thickness(DFT) microns) |
1000.0 |
|
Prequalification requirements of polyurethane system (Adhesion to steel(pull off ) ASTM D4541) |
5000.0 |
|
Prequalification requirements of polyurethane system (Hardness Shore D scale ASTM D2240) |
2000.0 |
|
Prequalification requirements of polyurethane system (Water absorption ASTM D570) |
1500.0 |
|
Prequalification requirements of polyurethane system (Dielectric strength. ASTM D149 (at 25 mils)) |
10000.0 |
|
Prequalification requirements of polyurethane system (Chemical resistance 30 percent sodium hydroxide (NaOH), immersion test for 30 days
ASTM D543 Practice A) |
1500.0 |
|
Prequalification requirements of polyurethane system (Chemical resistance 30 percent sodium chloride (NaCl), immersion test for 30 days
ASTM D543 Practice A) |
1500.0 |
|
Prequalification requirements of polyurethane system (Chemical resistance 10 % sulfuric acid (H2SO4) immersion test for 30 days
ASTM D543 Practice A) |
1500.0 |
|
Prequalification requirements of polyurethane system (Abrasion resistance CS17 wheel with a 1-kg weight (ASTM D4060 )) |
5000.0 |
|
Prequalification requirements of polyurethane system (Impact resistance (ASTM G14)) |
2500.0 |
|
Prequalification requirements of polyurethane system (Flexibility ASTM D522 Test Method B) |
1000.0 |
|
4 Polyurethane System Requirements (Cathodic disbondment (ASTM G8)) |
5000.0 |
|
Prequalification requirements of polyurethane system (Resistance to UV Degradation ( ASTM G154)
4 h UV at 60 (±3) °C Black Panel Temperature;
4 h Condensation at 50 (±3) °C Black Panel Temperature) |
3500.0 |
|
1a (Specific Gravity (after Mixing Comp A+ Comp B)) |
1000.0 |
|
additional parameter (Adhesion to steel) |
1200.0 |
|
|
478 |
ASTM D149-20, ASTM D 3330 and Customer Requirements - Discrete tests as per relevant specifications and Customer Requirements |
Discrete tests as per relevant specifications and Customer Requirements |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Dielectric Strength Test as per ASTM D149-20) |
10000.0 |
|
2 (Temperature Test) |
10000.0 |
|
3 (Thickness) |
1000.0 |
|
4 (Elongation at breaking) |
2000.0 |
|
5 (Adhesion to steel as per ASTM D-3330) |
2000.0 |
|
|
479 |
TI/SPC/OHE/CW/0971 - Hard drawn grooved copper(HDGC) contact Wire for Electrical Traction (Drawn out of continuous Cast copper wire Rod)
. |
Hard drawn grooved copper(HDGC) contact Wire for Electrical Traction (Drawn out of continuous Cast copper wire Rod)
. |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
9.1.1 (Visual Examination) |
1000.0 |
|
9.1.2 (Dimension) |
2000.0 |
|
9.1.3 (Weight) |
1500.0 |
|
9.1.4 (Resistance/km at 20 Deg. C) |
3000.0 |
|
9.1.5 (Brinell Hardness) |
2000.0 |
|
9.1.6 (Tensile Strength) |
2000.0 |
|
9.1.7 (Elongation at Gauge Length 200 mm) |
1000.0 |
|
9.1.8 (Bending Test) |
1000.0 |
|
9.1.9 ((Cu+Ag)) |
2000.0 |
|
9.1.10 (Micro structure Examination) |
3000.0 |
|
|
480 |
BS EN12385-1:2002 (2002) - Steel Wire ropes-Safety |
Steel Wire ropes-Safety |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
6.4.1 (Breaking Force) |
2000.0 |
|
A (Elongation as per customer request) |
1000.0 |
|
|