391 |
NTHER- Calibration of Furnace - Calibration of Furnace |
Calibration of Furnace |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
A1 (Calibration of parameter Temperature) |
6000.0 |
|
A2 (Calibration of parameter Temperature) |
8000.0 |
|
|
392 |
NTHER Calibration of Hot air Oven - Calibration of Hot air Oven |
Calibration of Hot air Oven |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
A1 (Calibration of parameter Temperature) |
6000.0 |
|
A2 (Calibration of parameter Temperature) |
8000.0 |
|
|
393 |
17880 (2022) - GEOSYNTHETICS — SYNTHETIC POLYMER
ROPE GABIONS FOR COASTAL AND WATERWAYS
PROTECTION — SPECIFICATION |
GEOSYNTHETICS — SYNTHETIC POLYMER
ROPE GABIONS FOR COASTAL AND WATERWAYS
PROTECTION — SPECIFICATION |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
7.0 (Breaking Strength of Rope) |
5000.0 |
|
7.0 (Breaking Strength After Thermal Stability at 45 °C
for 3 hours) |
7000.0 |
|
|
394 |
IS 374:2019 (2019) - Electric Ceiling Type Fans - Specification |
Electric Ceiling Type Fans - Specification |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
11 (Starting) |
500.0 |
|
12 (Interchangeability) |
500.0 |
|
15.1 (Air Delivery Test) |
10000.0 |
|
15.1 (Service Value Test) |
500.0 |
|
14.5 (Power Factor) |
500.0 |
|
14.4 (Measurement of speed of Fan) |
500.0 |
|
9 (Cl.24 of IS 302-2-80) (Safety Requirements, Components) |
500.0 |
|
9 (Cl.29 of IS 302-2-80) (Safety Requirements,Creepage Distance & Clearance distance) |
500.0 |
|
9 (Cl.11 of IS 302-2-80) (Safety Requirements,Heating) |
500.0 |
|
9 (Cl.23 of IS 302-2-80) (Safety Requirements,Internal Wiring) |
500.0 |
|
9 (Cl.16 of IS 302-2-80) (Safety Requirements,Leakage Current and Electric Strength) |
1000.0 |
|
9 (Cl.21 of IS 302-2-80) (Safety Requirements,Mechanical Strength) |
1000.0 |
|
9 (Cl.15 of IS 302-2-80) (Safety Requirements,Moisture resistance test) |
1000.0 |
|
9 (Cl.10 of IS 302-2-80) (Safety Requirements,Power Input and Current) |
1000.0 |
|
9 (Cl.8 of IS 302-2-80) (Safety Requirements,Protection against access to live parts) |
500.0 |
|
9 (Cl.27 of IS 302-2-80) (Safety Requirements,Provision for earthing) |
500.0 |
|
9 (Cl.31 of IS 302-2-80) (Safety Requirements,Resistance to rusting) |
500.0 |
|
9 (Cl.25 of IS 302-2-80) (Safety Requirements,Supply connection and external flexible cords) |
500.0 |
|
9 (Cl.14 of IS 302-2-80) (Safety Requirements,Transient overvoltage) |
500.0 |
|
9 (Cl.13 of IS 302-2-80) (Safety Requirements,Leakage Current and Electric Strength at operating temperature) |
1000.0 |
|
9 (Cl.28 of IS 302-2-80) (Safety Requirements,Screws and Connection) |
500.0 |
|
13 (Silent Operation) |
500.0 |
|
17 (TEST FOR HARMONIC DISTORTION) |
5000.0 |
|
|
395 |
CUSTOM - Distance bush to grade RDSO |
Distance bush to grade RDSO |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Carbon, Percent) |
1200.0 |
|
2 (Manganese, Percent) |
1200.0 |
|
3 (Silicon, Percent) |
1200.0 |
|
4 (Sulphur, Percent) |
1200.0 |
|
5 (Phosphorus, Percent) |
1200.0 |
|
6 (Chromium Percent) |
1200.0 |
|
7 (Molybdenum, Percent) |
1200.0 |
|
8 (Nickel, Percent) |
1200.0 |
|
9 (Others) |
1200.0 |
|
|
396 |
CUSTOM-BOLT FOR FIAT-EN36A - BOLT FOR FIAT-EN36A |
BOLT FOR FIAT-EN36A |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Carbon ,Percent) |
1200.0 |
|
2 (Silicon, Percent) |
1200.0 |
|
3 (Manganese, Percent) |
1200.0 |
|
4 (Nickel, Percent) |
1200.0 |
|
5 (Chromium, Percent) |
1200.0 |
|
6 (Molybdenum, Percent) |
1200.0 |
|
7 (Sulphur, Percent) |
1200.0 |
|
8 (Phosphorus, Percent) |
1200.0 |
|
|
397 |
4432 - SPECIFICATION FOR CASE HARDENING STEELS |
SPECIFICATION FOR CASE HARDENING STEELS |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Carbon, Percent by mass) |
1200.0 |
|
2 (Silicon, Percent) |
1200.0 |
|
3 (Manganese, Percent) |
1200.0 |
|
4 (Nickel, Percent) |
1200.0 |
|
5 (Chromium, Percent) |
1200.0 |
|
6 (Molybdenum, Percent) |
1200.0 |
|
7 (Sulphur, Percent) |
1200.0 |
|
8 (Phosphorus, Percent) |
1200.0 |
|
|
398 |
IS:7098(Part 1)-1988 - Cross linked polyethylene insulated PVC sheathed cables, Part 1: For working voltage upto and including 1 100 V |
Cross linked polyethylene insulated PVC sheathed cables, Part 1: For working voltage upto and including 1 100 V |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
15.1 a) iv, b, c, d) i, ii, iii, iv e) i, ii, iii, iv, vi, viii, f, g,h (Discrete tests as per IS:7098(Part-1)-1988) |
22000.0 |
|
|
399 |
JHA BABA Specification (2023) - TEST of Environment |
TEST of Environment |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (HV test at 1.5 KV between live parts & neutral of MCB, Duration 1 Minute) |
3000.0 |
|
2 (IP 5X protection against Dust Test as per Clause 7.5 Table Cl of IS 13947 Part 1 ,1993) |
7500.0 |
|
3 (HV Test at 1.5 KV between Live & Neutral of MCB, Duration 01 Min) |
3000.0 |
|
4 (IP X 5
Protection against water Jet
Nozzle Dia : 6.3 mm
water Pressure 0.3 Bar
Distance :3 Meter
Duration :03 Minutes) |
7500.0 |
|
5 (High Voltage test at 1.5KV between live parts and neutral of MCB, Duration 1 Min) |
3000.0 |
|
|
400 |
IS 7608 (1987) - Specification for phosphor bronze wire for general engineering purposes (First Revision) |
Specification for phosphor bronze wire for general engineering purposes (First Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
4 (Freedom from defects - Surface Finish) |
1000.0 |
|
7.1 (Tensile Strength. (wire dia. 0.45 to 6.0 mm)) |
1500.0 |
|
7.1 (Elongation percent of gauge length.) |
1500.0 |
|
7.2 (Wrapping Test.) |
1000.0 |
|
8 (Diameter of the wire.) |
1000.0 |
|
6 (Tin) |
500.0 |
|
6.1 (Phosphorus) |
500.0 |
|
6.1 (Lead) |
500.0 |
|
6.1 (Copper) |
500.0 |
|
6.1 (Total Impurities) |
1000.0 |
|
|
401 |
Custom-30-ER-LM - Load Test on Solar Road Stud |
Load Test on Solar Road Stud |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Load Test on Winch) |
4000.0 |
|
2 (Load Test on Solar Road Stud) |
5000.0 |
|
|
402 |
IS 516 : Part 5 : Sec 4 (2020) - Hardened Concrete Methods of Test Part 5 Non-Destructive Testing of Concrete Section 4 Rebound Hammer Test ( First Revision ) |
Hardened Concrete Methods of Test Part 5 Non-Destructive Testing of Concrete Section 4 Rebound Hammer Test ( First Revision ) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
0 (Rebound hammer test (field test) -per Ten locations) |
15000.0 |
|
- - (Scientist charges (2 Scientists) for site testing / inspection) |
10000.0 |
|
|
403 |
RDSO TI/SPC/PSI/ISOLTR/0210 - 25KV Motorised/Manual operated and 50KV/66KV/100KV/110KV/132KV/220KV Manual operated single pole,Double pole and Triple Pole Isolators for Railway Electric Traction |
25KV Motorised/Manual operated and 50KV/66KV/100KV/110KV/132KV/220KV Manual operated single pole,Double pole and Triple Pole Isolators for Railway Electric Traction |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
7.1 (Visual Examination) |
1000.0 |
|
7.2 (Dimension) |
2000.0 |
|
7.10 (Mass of Zinc Coating as per ETI/OHE/13) |
2000.0 |
|
7.10 (Adherence Test as per ETI/OHE/13) |
2000.0 |
|
7.10 (Uniformity of coating as per ETI/OHE/13) |
1000.0 |
|
7.11.1 (Chemical Analysis) |
5000.0 |
|
7.11.2 (Physical Test on Fasteners as per RDSO specification No. TI/SPC/OHE/FASTENERS/0120) |
5000.0 |
|
7.11.3 (Physical Test on Copper Strips as per IS 1897) |
8000.0 |
|
|
404 |
EIL SOLVENT FREE GLASS FLAKE REINFORCED EPOXY (Two Pack) (0) - SOLVENT FREE GLASS FLAKE REINFORCED EPOXY (Two Pack) |
SOLVENT FREE GLASS FLAKE REINFORCED EPOXY (Two Pack) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (SOLID CONTENT (%)) |
1000.0 |
|
2 (DRY FILM THICKNESS/COAT (Microns)
ASTM-D-4400-84) |
1000.0 |
|
3 (RESISTANCE TO WET TEMPERATURE:14 deg C TO 60 deg C) |
10000.0 |
|
4 (IMPACT RESISTANCE at 250 microns coating at 23 deg C
reverse and direct
ASTM G14) |
3000.0 |
|
5 (ABRASION RESISTANCE at 1000g weight /1000 cycles /CS-17
ASTM D4060
loss in mg) |
5000.0 |
|
7 (ADHESION TO STEEL (Mpa)
ASTM D 4541) |
5000.0 |
|
8 (HARDENESS: SHORE D
ASTM D 3363) |
3500.0 |
|
9 (WATER ABSORPTION FOR IMMERSION OF 30 DAYS (g/m2)
ASTM -D-570) |
3000.0 |
|
10 (SALT SPRAY TEST FOR 1440 hrs
ISO 7253) |
35000.0 |
|
11 (HOLIDAY TEST at low voltage up to 2 kv
at 500 microns DFT
ASTM D 5162) |
2500.0 |
|
12 (MASS DENSITY OF base and hardener (wt. per ltr)
(gm/cm3) ASTM D 1475) |
1200.0 |
|
13 (Drying Time TOUCH DRY at 30 deg C
ASTM D 1640) |
1200.0 |
|
13 (FULL CURING FOR SERVICE EXPOSURE
ASTM D 1640) |
1200.0 |
|
14 (INTER COAT ADHESION
ASTM D 3359) |
1200.0 |
|
15 (EPOXY EQUIVALENT
ASTM D 1652) |
3500.0 |
|
16 (Overcoating Interval time
For Second coat ASTM D 1640) |
200.0 |
|
|
405 |
RDSO/SPN/176/2013 ver 3.0 eff date 31.03.2014 (2014) - Specification for Multi Section Digital Axel Counter |
Specification for Multi Section Digital Axel Counter |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
11.5.5.6 (Salt Mist Test(RDSO/SPN/144/2014)
Test Condition:2 hours +22 Hours(Mist + Damp Heat)
Temperature:35 (+/-)3 deg C
Humidity:93 % (+2% ,-3%)) |
5000.0 |
|
|
406 |
NTH PAINT 2023 Water Based PU Waterproofing Compound (2023) - Water Based PU Waterproofing Compound
(Cold liquid Elastomeric Waterproofing ) |
Water Based PU Waterproofing Compound
(Cold liquid Elastomeric Waterproofing ) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Colour & Apperance) |
200.0 |
|
2 (Specific gravity at 30Deg C) |
1000.0 |
|
3 (Solid Content % by mass) |
1000.0 |
|
4 (Dry Film Thickness ,(DFT) in mm) |
1000.0 |
|
5 (Elongation @break %) |
2000.0 |
|
6 (QUV test for 200 hours (Fluorescent UV-Condensation)
Exposures
ASTM D4587) |
8000.0 |
|
7 (Tensile Strength N/mm2) |
1000.0 |
|
8 (Pull off Adhesion Strength
(ASTM D 4541) on
concrete Substrate) |
3500.0 |
|
9 (Water Vapor Permeability Test
ASTM D1653) |
2000.0 |
|
10 (Surface Drying Time) |
500.0 |
|
|
407 |
ND Custom 8 (2023) - Load test for steel roller Assembly |
Load test for steel roller Assembly |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Compressive Load Test) |
10000.0 |
|
|
408 |
IS 3384 (1986) - bitumen primer for use in waterproofing and damp-proofing |
bitumen primer for use in waterproofing and damp-proofing |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
3.1 (i) (Viscocity 25dg,tar viscometer 4mm orifice) |
1200.0 |
|
ADDITIONAL pARAMETER (Specific gravity) |
1200.0 |
|
|
409 |
IS 1367 : Part 13 (2020) - Technical Supply Conditions for Threaded Steel Fasteners Part 13 Hot Dip Galvanized Coatings on Threaded Fasteners ( Third Revision ) |
Technical Supply Conditions for Threaded Steel Fasteners Part 13 Hot Dip Galvanized Coatings on Threaded Fasteners ( Third Revision ) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
8.3 (Coating Thickness) |
2000.0 |
|
|
410 |
IS 1254 (2007) - Corrugated aluminium sheet (Fourth Revision) |
Corrugated aluminium sheet (Fourth Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
7 (Dimension) |
1000.0 |
|
6 (Aluminium) |
500.0 |
|
6 (Copper) |
600.0 |
|
6 (Magnesium) |
500.0 |
|
6 (Silicon) |
500.0 |
|
6 (Iron) |
600.0 |
|
6 (Manganese) |
500.0 |
|
6 (Zinc) |
600.0 |
|
6 (Titanium) |
600.0 |
|
6 (Chromium) |
600.0 |
|
7.1 (Tensile strength) |
1000.0 |
|
6 (0.2% Proof Stress) |
1000.0 |
|
6 (Elongation on 50 mm Gauge Length) |
1000.0 |
|
6 (Bend Test) |
1500.0 |
|
|
411 |
CUSTOM-12-ER-MCALI - Poldi Hardness Tester |
Poldi Hardness Tester |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Hardness) |
4000.0 |
|
|
412 |
CUSTOM-11-ER-MCALI - Dynamic Hardness Tester (HRC, HRB & HBW) |
Dynamic Hardness Tester (HRC, HRB & HBW) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Hardness (HRC,HRB & HBW)) |
12000.0 |
|
|
413 |
CUSTOM-10-ER-MCALI - Steel Bar |
Steel Bar |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Dimension) |
1200.0 |
|
|
414 |
CUSTOM-09-ER-MCALI - Ultrasonic Step Gauge |
Ultrasonic Step Gauge |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Dimension) |
2000.0 |
|
|
415 |
IS 101 Part 1 Section 7 (2020) - Methods of Sampling and Test for Paints, Varnishes and Related Products - Part 1 Test on Liquid Paints ( General and Physical ) - Section 7 Mass per 10 litres-Determination of density-Pycnometer method |
Methods of Sampling and Test for Paints, Varnishes and Related Products - Part 1 Test on Liquid Paints ( General and Physical ) - Section 7 Mass per 10 litres-Determination of density-Pycnometer method |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
3.1 (Volume of Pyknometer) |
2000.0 |
|
|
416 |
CUSTOM-08-ER-MCALI - DIAL GAUGE OF PENETROMETER |
DIAL GAUGE OF PENETROMETER |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (DIMENSION) |
2000.0 |
|
|
417 |
IS 9440 (1979) - Laboratory Balances |
Laboratory Balances |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
9 (Double Pan Balance) |
4000.0 |
|
|
418 |
IS 9537(Part-I)-1980 & (Part-3)-1983 - SPECIFICATION FOR CONDUITS FOR ELECTRICAL INSTALLATIONS |
SPECIFICATION FOR CONDUITS FOR ELECTRICAL INSTALLATIONS |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
6 (MARKING) |
1000.0 |
|
7.1 (Outside Dia) |
2000.0 |
|
9.2 (Bending test) |
2500.0 |
|
9.3 (Compression test) |
2000.0 |
|
9.4 (Impact test) |
3000.0 |
|
10 (Resistance to heat) |
5000.0 |
|
11 (Resistance to burning) |
2000.0 |
|
12.1.2 (Insulation Resistance) |
5000.0 |
|
12.1.1 (Electrical Strength) |
5000.0 |
|
|
419 |
IS 737 - WROUGHT ALUMINIUM AND ALUMINIUM ALLOY SHEET AND STRIP FOR GENERAL ENGINEERING
PURPOSES - SPECIFICATION |
WROUGHT ALUMINIUM AND ALUMINIUM ALLOY SHEET AND STRIP FOR GENERAL ENGINEERING
PURPOSES - SPECIFICATION |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
9 (Dimension) |
1000.0 |
|
7.2 (Bend Test) |
1500.0 |
|
7.1 (Tensile strength) |
2000.0 |
|
7.1 (0.2% Proof Stress) |
1000.0 |
|
7.1 (Elongation on 50 mm Gauge Length) |
1000.0 |
|
6 (Aluminium) |
500.0 |
|
6 (Copper) |
1000.0 |
|
6 (Magnesium) |
500.0 |
|
6 (Silicon) |
500.0 |
|
6 (Iron) |
500.0 |
|
6 (Manganese) |
500.0 |
|
6 (Zinc) |
500.0 |
|
6 (Titanium) |
500.0 |
|
6 (Chromium) |
30.0 |
|
0 (Thickness of Anodic Coating) |
2000.0 |
|
|
420 |
IS 9537 (Part 1 & 3) - SPECIFICATION FOR CONDUITS FOR ELECTRICAL INSTALLATIONS |
SPECIFICATION FOR CONDUITS FOR ELECTRICAL INSTALLATIONS |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|