391 |
IS 14223 : Part 1 (1995) - Polished Building Stones: Part 1 Granite |
Polished Building Stones: Part 1 Granite |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
5 (Resistance to wear) |
4000.0 |
|
5 (Hardness) |
2000.0 |
|
5 (Ultrasonic pulse velocity) |
5000.0 |
|
5 (Shear strength) |
2000.0 |
|
5 (Tensile strength) |
2000.0 |
|
5 (Porosity) |
1000.0 |
|
5 (Water absorption) |
1000.0 |
|
5 (Compressive strength) |
2000.0 |
|
5 (Specific gravity) |
1000.0 |
|
5 (Dry density ) |
1000.0 |
|
5 (Moisture content) |
500.0 |
|
4 (Dimensions) |
500.0 |
|
|
392 |
IS 3316 (1974) - Structural Granite |
Structural Granite |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
3.3 (Water Absorption) |
1000.0 |
|
3.2 (Specific Gravity) |
1000.0 |
|
3.1 (Compressive Strength) |
2000.0 |
|
|
393 |
IS 1125 (1974) - Natural Building Stone |
Natural Building Stone |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
394 |
IEC 61427-1: 2013 (2013) - Secondary cells and batteries for renewable energy storage - General requirements and methods of test-
Part 1: Photovoltaic off-grid application |
Secondary cells and batteries for renewable energy storage - General requirements and methods of test-
Part 1: Photovoltaic off-grid application |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
8.1 (Capacity Test) |
60000.0 |
|
8.3 (Charge retension test) |
25000.0 |
|
8.4 (Cycling endurance test in photovoltaic applications(extreme conditions)) |
70000.0 |
|
|
395 |
IS 5154(Part 1 & 2): 2013 (2013) - Lead Acid Traction Batteries |
Lead Acid Traction Batteries |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
5.2 of IS 5154(Part-1)-2013 (5 h Capacity Test) |
25000.0 |
|
5.5 of IS 5154 (Part-1)-2013 (Cyclic Endurance Test) |
90000.0 |
|
3 and 5 of IS 5154(Part-2)-2013 (Dimensions of Traction Batteries) |
1000.0 |
|
5.4 (1 h High rate discharge performance test) |
15000.0 |
|
5.3 (Charge retention test) |
20000.0 |
|
|
396 |
Custom-32-ER-LM - Load Testing of Mounting Fixtures |
Load Testing of Mounting Fixtures |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Load Testing of the Mounting Fixture for 72Hours) |
15000.0 |
|
|
397 |
IEC 61439-1: 2009 & IS/IEC:60529-2001 - IP-65 Class of protection test
Drawing Verification
Power Frequency Voltage withstand test before and after IP test
Dielectric Properties test before and after IP test |
IP-65 Class of protection test
Drawing Verification
Power Frequency Voltage withstand test before and after IP test
Dielectric Properties test before and after IP test |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (IP-65 Class of Protection test) |
15000.0 |
|
2 (Drawing verification) |
3000.0 |
|
3 (Power frequency voltage withstand test) |
5000.0 |
|
4 (Di-electric properties test) |
5000.0 |
|
|
398 |
IS/IEC:60529-2001 & IEC 61439-1: 2009 - IP-42 Class of protection test
Drawing Verification
Power Frequency Voltage withstand test after IP test
Dielectric Properties test after IP test |
IP-42 Class of protection test
Drawing Verification
Power Frequency Voltage withstand test after IP test
Dielectric Properties test after IP test |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (IP-42 Class of protection test) |
15000.0 |
|
2 (Drawing verification) |
3000.0 |
|
3 (Power Frequency voltage withstand test) |
2500.0 |
|
4 (Di-electric Properties test) |
5000.0 |
|
|
399 |
JSG 0102:1984 - JOINT SERVICES GUIDE ON ENVIRONMENTAL TESTING ON ARMAMENT STORES |
JOINT SERVICES GUIDE ON ENVIRONMENTAL TESTING ON ARMAMENT STORES |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
As per specification & customer requirements (Discrete Tests) |
65000.0 |
|
|
400 |
IS 1708(Parts 1-18)1986: RA 2020 - METHODS OF TESTING OF SMALL CLEAR SPECIMENS OF TIMBER |
METHODS OF TESTING OF SMALL CLEAR SPECIMENS OF TIMBER |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Moisture content (IS 1708(1):1986)) |
1000.0 |
|
2 (Specific gravity (IS 1708(2):1986)) |
500.0 |
|
3 (Volumetric Shrinkage (IS 1708(3)1986)) |
1000.0 |
|
5 (Static bending strength (IS 1708(5):1986)
1.Fibre stress at limit of proportionality(FS at LP)
2.Equivalent fibre stress at maximum load(MOR)
3.Modulus of Elasticity( M of E)
4.Horizontal shear(HS)stress on neutral plan at LP
5.Horizontal shear stress at maximum load(ML)
6.Wk to LP
7.Wk to ML) |
3000.0 |
|
15 (Nail and Screw holding power(IS 1708(15):1986)) |
3000.0 |
|
8 (Compressive strength-Parallel to grain(IS 1708(8)1986)) |
1500.0 |
|
9 (Compressive strength-Perpendicular to grain(IS 1708(9):1986)) |
1500.0 |
|
12 (Tensile strength -Parallel to grain(IS 1708(12):1986)) |
2000.0 |
|
|
401 |
AMS 2630B (1995) - AEROSPACE MATERIAL SPECIFICATION |
AEROSPACE MATERIAL SPECIFICATION |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
4.1.1 (Ultrasonic Testing) |
2000.0 |
|
|
402 |
NTH ER HIGH POLYMER LAB (2022) - GLORIA BLUE Color
L*A*B* value testing using D65 light Source |
GLORIA BLUE Color
L*A*B* value testing using D65 light Source |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (GLORIA BLUE Color
L*A*B* value testing using D65 light Source) |
10000.0 |
|
|
403 |
ND Custom 6 (2023) - Aluminium and Aluminium Alloy Plates |
Aluminium and Aluminium Alloy Plates |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Tensile and Bend Test) |
4500.0 |
|
|
404 |
IS 398 : Part 5 (1992) - Aluminium conductor for overhead transmission purposes - Specification: Part 5 aluminium conductors - Galvanized steel - Reinforced for extra high voltage (400 KV And Above) (First Revision) |
Aluminium conductor for overhead transmission purposes - Specification: Part 5 aluminium conductors - Galvanized steel - Reinforced for extra high voltage (400 KV And Above) (First Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
13.3 (Measurement of Diameters of Individual Aluminium and Steel Wires) |
1000.0 |
|
13.4 (Measurement of Lay Ratio) |
2000.0 |
|
13.5.2 (Breaking Load Test on Individual Wires) |
3500.0 |
|
13.6 (Ductility Test) |
3500.0 |
|
13.7 (Wrapping Test) |
1000.0 |
|
13.8 (Resistance Test) |
5000.0 |
|
13.9 (Galvanizing Test) |
2000.0 |
|
|
405 |
IS 398 : Part 2 (1996) - Aluminium conductors for overhead transmission purposes - Specification: Part 2 aluminium conuuctors, galvanized steel - Reinforced (Third Revision) |
Aluminium conductors for overhead transmission purposes - Specification: Part 2 aluminium conuuctors, galvanized steel - Reinforced (Third Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
13.2 (Measurement of diameter of individual Aluminium wires (7 wire construction)) |
1000.0 |
|
13.3 (Breaking load of individual Aluminium wires (7 wire construction)) |
3500.0 |
|
13.4.1 (Ductility test-Torsion test on steel wires (7 Wire construction)) |
3500.0 |
|
13.5 (Wrapping test on Aluminium and Steel wires (7 wire construction)) |
1000.0 |
|
13.6 (Resistance of Aluminium wire (7 wire construction)) |
5000.0 |
|
13.8 (Measurement of lay ratio(7 wire construction)) |
2000.0 |
|
13.7(1) (Galvanizing test-Mass of zinc coating(7wire construction)) |
2000.0 |
|
|
406 |
AWWA C222-18 (2018) - Polyurethane Coatings and Linings for Steel Water Pipe and Fittings |
Polyurethane Coatings and Linings for Steel Water Pipe and Fittings |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
Prequalification requirements of polyurethane system (Appearance) |
1000.0 |
|
Prequalification requirements of polyurethane system (Electrical continuity inspection(Holiday test)) |
3500.0 |
|
Prequalification requirements of polyurethane system (Dry film thickness(DFT) microns) |
1000.0 |
|
Prequalification requirements of polyurethane system (Adhesion to steel(pull off ) ASTM D4541) |
5000.0 |
|
Prequalification requirements of polyurethane system (Hardness Shore D scale ASTM D2240) |
2000.0 |
|
Prequalification requirements of polyurethane system (Water absorption ASTM D570) |
1500.0 |
|
Prequalification requirements of polyurethane system (Dielectric strength. ASTM D149 (at 25 mils)) |
10000.0 |
|
Prequalification requirements of polyurethane system (Chemical resistance 30 percent sodium hydroxide (NaOH), immersion test for 30 days
ASTM D543 Practice A) |
1500.0 |
|
Prequalification requirements of polyurethane system (Chemical resistance 30 percent sodium chloride (NaCl), immersion test for 30 days
ASTM D543 Practice A) |
1500.0 |
|
Prequalification requirements of polyurethane system (Chemical resistance 10 % sulfuric acid (H2SO4) immersion test for 30 days
ASTM D543 Practice A) |
1500.0 |
|
Prequalification requirements of polyurethane system (Abrasion resistance CS17 wheel with a 1-kg weight (ASTM D4060 )) |
5000.0 |
|
Prequalification requirements of polyurethane system (Impact resistance (ASTM G14)) |
2500.0 |
|
Prequalification requirements of polyurethane system (Flexibility ASTM D522 Test Method B) |
1000.0 |
|
4 Polyurethane System Requirements (Cathodic disbondment (ASTM G8)) |
5000.0 |
|
Prequalification requirements of polyurethane system (Resistance to UV Degradation ( ASTM G154)
4 h UV at 60 (±3) °C Black Panel Temperature;
4 h Condensation at 50 (±3) °C Black Panel Temperature) |
3500.0 |
|
1a (Specific Gravity (after Mixing Comp A+ Comp B)) |
1000.0 |
|
additional parameter (Adhesion to steel) |
1200.0 |
|
|
407 |
ASTM D149-20, ASTM D 3330 and Customer Requirements - Discrete tests as per relevant specifications and Customer Requirements |
Discrete tests as per relevant specifications and Customer Requirements |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Dielectric Strength Test as per ASTM D149-20) |
10000.0 |
|
2 (Temperature Test) |
10000.0 |
|
3 (Thickness) |
1000.0 |
|
4 (Elongation at breaking) |
2000.0 |
|
5 (Adhesion to steel as per ASTM D-3330) |
2000.0 |
|
|
408 |
TI/SPC/OHE/CW/0971 - Hard drawn grooved copper(HDGC) contact Wire for Electrical Traction (Drawn out of continuous Cast copper wire Rod)
. |
Hard drawn grooved copper(HDGC) contact Wire for Electrical Traction (Drawn out of continuous Cast copper wire Rod)
. |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
9.1.1 (Visual Examination) |
1000.0 |
|
9.1.2 (Dimension) |
2000.0 |
|
9.1.3 (Weight) |
1500.0 |
|
9.1.4 (Resistance/km at 20 Deg. C) |
3000.0 |
|
9.1.5 (Brinell Hardness) |
2000.0 |
|
9.1.6 (Tensile Strength) |
2000.0 |
|
9.1.7 (Elongation at Gauge Length 200 mm) |
1000.0 |
|
9.1.8 (Bending Test) |
1000.0 |
|
9.1.9 ((Cu+Ag)) |
2000.0 |
|
9.1.10 (Micro structure Examination) |
3000.0 |
|
|
409 |
BS EN12385-1:2002 (2002) - Steel Wire ropes-Safety |
Steel Wire ropes-Safety |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
6.4.1 (Breaking Force) |
2000.0 |
|
A (Elongation as per customer request) |
1000.0 |
|
|
410 |
ND Custom 5 (2023) - Load Testing of Winch |
Load Testing of Winch |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1.0 (Load Testing of Single Drum Winch as per customer request) |
5000.0 |
|
2.0 (Load Testing of Single Drum Winch as per customer request) |
5000.0 |
|
|
411 |
NTH ER PAINT CUS SPECIFICATION BERGER 2023 (2023) - NTH ER PAINT CUS SPECIFICATION BERGER 2023
REML TEST SPECIFICATION |
NTH ER PAINT CUS SPECIFICATION BERGER 2023
REML TEST SPECIFICATION |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (REML TEST) |
100000.0 |
|
|
412 |
NTH ER PAINT CUS SPECIFICATION 2023 (2023) - NTH ER PAINT CUS SPECIFICATION 2023
(Anti-Carbonation |
NTH ER PAINT CUS SPECIFICATION 2023
(Anti-Carbonation |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (As per Customer Requirement) |
12000.0 |
|
|
413 |
Custom - Wood Pellets |
Wood Pellets |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1. (Total Moisture) |
1200.0 |
|
2 (Ash content) |
1200.0 |
|
3 (Volatile matter) |
1200.0 |
|
4 (Fixed Carbon) |
1200.0 |
|
5 (Gross Calorific value) |
2000.0 |
|
6 (Sodium + Potassium) |
1200.0 |
|
7 (Cadmium) |
1200.0 |
|
8 (Chromium) |
1200.0 |
|
9 (Copper) |
1200.0 |
|
10 (Lead) |
1200.0 |
|
11 (Nickel) |
1200.0 |
|
12 (Zinc) |
1200.0 |
|
|
414 |
IS : 2720 ( Part XXVII ) - 1977 - METHODS OF TEST FOR SOILS: PART (XXVII) DETERMINATION OF TOTAL SOLUBLE SULPHATES |
METHODS OF TEST FOR SOILS: PART (XXVII) DETERMINATION OF TOTAL SOLUBLE SULPHATES |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
2 (Total Soluble sulphate) |
2000.0 |
|
|
415 |
7514 (2020) - Grease, Low Temperature ―Specification |
Grease, Low Temperature ―Specification |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Drop point,) |
1200.0 |
|
5 (Water content,) |
1200.0 |
|
6 (Copper strip, corrosion at 25 ºC, 24 h) |
1200.0 |
|
7 (Oil separation, percent by mass, 168 hrs, Max) |
1200.0 |
|
11 (Consistency of worked grease at 25.0 ± 0.5ºC (60 double
strokes)) |
1200.0 |
|
|
416 |
IS 7514 (2020) - Grease, Low Temperature ? Specification ( Second Revision ) |
Grease, Low Temperature ? Specification ( Second Revision ) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
417 |
IS 12766 (1997) - Paper, computer - Specification (First Revision) |
Paper, computer - Specification (First Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
4.1.1 (Grammage (Sustance)) |
1000.0 |
|
4.6 (Table 1) (Bulk) |
1000.0 |
|
4.6 (Table 1) (Moisture Content) |
1000.0 |
|
4.6 (Table 1) (Ash) |
2000.0 |
|
4.6 (Table 1) (Tensile index) |
2000.0 |
|
4.6 (Table 1) (Burst index) |
2000.0 |
|
4.6 (Table 1) (Tear index) |
2000.0 |
|
4.6 (Table 1) (Cobb Test) |
1000.0 |
|
4.6 (Table 1) (Opacity) |
2000.0 |
|
4.6 (Table 1) (Brightness) |
2000.0 |
|
4.6 (Table 1) (Smoothness) |
1000.0 |
|
|
418 |
Custom-28-ER-LM - Impact Test |
Impact Test |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Impact Test) |
85000.0 |
|
|
419 |
IS 280 (2006) - Mild steel wire for general engineering purposes (Fourth Revision) |
Mild steel wire for general engineering purposes (Fourth Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
9.2 (Wrapping Test) |
1000.0 |
|
9.1 (Tensile Strength) |
3000.0 |
|
6 (Chemical Composition (Carbon)) |
625.0 |
|
6 (Chemical Composition (Manganese)) |
625.0 |
|
6 (Chemical Composition (Sulphur)) |
625.0 |
|
6 (Chemical Composition (Phosphorus)) |
625.0 |
|
0 (Mass of Zinc Coating) |
2000.0 |
|
0 (Uniformity of Coating) |
1000.0 |
|
0 (Coating Thickness) |
2000.0 |
|
0 (Weight) |
1000.0 |
|
0 (Tensile Strength of Wire) |
1000.0 |
|
7.1 (Wire Diameter) |
1000.0 |
|
7.1 (Wire Diameter) |
1000.0 |
|
13 (Freedom From Defects) |
1000.0 |
|
|
420 |
EN 10248-1 (1995) - Hot-rolled steel sheet piles - Part 1: Technical delivery conditions |
Hot-rolled steel sheet piles - Part 1: Technical delivery conditions |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
5 (Mass) |
2000.0 |
|
7.3 (Carbon) |
500.0 |
|
7.3 (Manganese) |
500.0 |
|
7.3 (Sulphur) |
500.0 |
|
7.3 (Phosphorus) |
500.0 |
|
7.3 (Silicon) |
500.0 |
|
7.3 (Nitrogen) |
500.0 |
|
7.4 (Yield Strength) |
1000.0 |
|
7.4 (Tensile Strength) |
1000.0 |
|
7.4 (Elongation) |
1000.0 |
|
8.7 (Dimensions) |
3000.0 |
|
|