| 1051 |
National Test House (SR), Chennai
| IS 1626 : Part 3 (1994) - Asbestos Cement Building types and Pipe Fittings, Gutters and Gutter Fittings and Roofing Fittings - Part 3 : Roofing Fittings |
Asbestos Cement Building types and Pipe Fittings, Gutters and Gutter Fittings and Roofing Fittings - Part 3 : Roofing Fittings |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6 (Impermeability test) |
1500.0 |
|
| 5 (Dimensions & Visual examination) |
5000.0 |
|
| 7 (General appearance & Finish) |
1000.0 |
|
|
| 1052 |
National Test House (SR), Chennai
| IS 2721 (2003) - Galvanized Steel Chain Link Fence Fabric |
Galvanized Steel Chain Link Fence Fabric |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6.2 (Mesh Size) |
500.0 |
|
| 6.3 (Width) |
500.0 |
|
| 6.3 (Length) |
500.0 |
|
| 6.1 (Nominal Dia of Mesh Wire) |
500.0 |
|
| 6.1 (Diameter of Line wire) |
500.0 |
|
| 9.1.1 (Tensile strength of Mesh wire) |
1500.0 |
|
| 9.1.1 (Tensile strength of Line wire) |
1500.0 |
|
| 9.1.2 (Wrapping Test of Mesh Wire) |
1000.0 |
|
| 9.1.2 (Wrapping test of Line wire) |
1000.0 |
|
| 9.1.3 (Twist Test of Mesh Wire) |
2000.0 |
|
| 9.1.3 (Twist Test of Line Wire) |
2000.0 |
|
| 9.1.4 (Bend test of Mesh wire) |
500.0 |
|
| 9.1.4 (Bend Test of Line wire) |
500.0 |
|
| 9.2 (Mass of Zinc Coating of Mesh Wire) |
2000.0 |
|
| 9.2 (Mass of Zinc Coating of Line Wire) |
2000.0 |
|
|
| 1053 |
National Test House (ER), Kolkata
| IS 17048 (2018) - Halogen Free Flame Retardant (HFFR) Cables for Working Voltages up to and including 1100 Volts-Specification |
Halogen Free Flame Retardant (HFFR) Cables for Working Voltages up to and including 1100 Volts-Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 15.6 Table 2 (iii) (a) (i) (Conductor Resistance Test) |
1500.0 |
|
| 15.6 Table 2 (iii) (a) (ii) (Annealing Test (For copper)) |
1000.0 |
|
| 15.6 Table 2 (iii) (b) (Test for Overall Dimensions and Thickness of Insulation and Sheath) |
1000.0 |
|
| 15.6 Table 2 (iii) (c) (iii) (Insulation Resistance Test) |
2000.0 |
|
| 15.6 Table 2 (iii) (c) (ii) or (iii) (f) (i) (High Voltage Test) |
1500.0 |
|
| 15.6 Table 2 (ii) (f) (Tensile strength and elongation at break) |
1500.0 |
|
| 15.6 Table 2 (iii) (c) (xiii) & (iii) (f) (v) (Flame Retardant Test) |
3000.0 |
|
| 15.6 Table 2 (iii) (f) (ii) (Flammability test) |
500.0 |
|
| - (Test on 2nd Core) |
2000.0 |
|
| - (Test on 3rd Core) |
2000.0 |
|
| - (Test on 4th Core) |
2000.0 |
|
|
| 1054 |
National Test House (NWR), Jaipur
| Custom Standard for RPPT Lab. Jaipur (2024) - Custom Standard for RPPT Lab. Jaipur |
Custom Standard for RPPT Lab. Jaipur |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Average Thickness in mm) |
2000.0 |
|
|
| 1055 |
National Test House (ER), Kolkata
| IS 9537 : Part 2 (1981) - Specification for conduits for electrical installations: Part 2 rigid steel conduits |
Specification for conduits for electrical installations: Part 2 rigid steel conduits |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 9.2 (Bending Test (With Seam on the Outside of flank)) |
500.0 |
|
| 9.2 (Bending Test (With Seam on the flank)) |
500.0 |
|
| 13 (External Influence Test (With Seam on the flank)) |
1000.0 |
|
| 13 (External Influence Test (With Seam on the Outside of the Bend)) |
1000.0 |
|
| 9.3 (Compression Test) |
3000.0 |
|
| 7 (Wall thickness) |
500.0 |
|
| 7 (Outside Diameter) |
500.0 |
|
| 7.2 (Checking the Minimum outside diameter.) |
750.0 |
|
| 7.2 (Checking the Maximum outside diameter) |
750.0 |
|
|
| 1056 |
National Test House (SR), Chennai
| IS 15961 :2025 (2025) - Hot Dip Aluminium-Zinc Alloy Metallic Coated Steel Strip and Sheet (Plain)- Specification |
Hot Dip Aluminium-Zinc Alloy Metallic Coated Steel Strip and Sheet (Plain)- Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 9.1 (Mass of coating (Both sides), g/Sq m) |
2000.0 |
|
| 8.3 (Tensile Strength) |
1000.0 |
|
| 8.3 (Yield Strength) |
1000.0 |
|
| 8.3 (Percent Elongation) |
1000.0 |
|
| 7.1 (Carbon. percent) |
500.0 |
|
| 7.1 (Manganese, percent) |
500.0 |
|
| 7.1 (Sulphur, percent) |
500.0 |
|
| 7.1 (Phosphorous, percent) |
500.0 |
|
| 7.1 (Aluminium, Percent) |
500.0 |
|
| 7.1 (Silicon, Percent) |
500.0 |
|
| 3.2 (Thickness of Sheet (base metal thickness), mm) |
1000.0 |
|
| 3.3 (Coated thickness (total coated thickness), mm) |
1000.0 |
|
|
| 1057 |
National Test House (NR), Ghaziabad
| IS: 1155-2022 (2022) - ATTA SPECIFICATION |
ATTA SPECIFICATION |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 4.4 Table 1 (Moisture, percent by mass) |
2000.0 |
|
| 4.4 Table 1 (Total ash (on dry basis), percent by mass) |
2000.0 |
|
| 4.4 Table 1 (Acid insoluble ash (on dry basis), percent by mass) |
2000.0 |
|
| 4.4 Table 1 (Gluten (on dry basis), percent by mass) |
2000.0 |
|
| 4.4 Table 1 (Alcoholic acidity (as H2SO4) in 90 percent alcohol, percent by mass) |
2000.0 |
|
|
| 1058 |
National Test House (NR), Ghaziabad
| Custom/Indo-Rusian Rifle (2024) - Indo-Rusian Rifle |
Indo-Rusian Rifle |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Hardness Test) |
2000.0 |
|
| 2 (Chemical Composition) |
4000.0 |
|
| 3 (Coating Thickness) |
1000.0 |
|
| 4 (Yield Strength) |
3000.0 |
|
| 5 (Elongation) |
1000.0 |
|
|
| 1059 |
National Test House (SR), Chennai
| IS 13238 (2021) - Epoxy Based Zinc Phosphate Primer (Two Pack ) — Specification |
Epoxy Based Zinc Phosphate Primer (Two Pack ) — Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Epoxy Based Zinc Phosphate Primer (Two Pack) — Specification (Please refer annexure for tests result) |
23000.0 |
|
|
| 1060 |
National Test House (ER), Kolkata
| CUSTOM/SHARPENER/2024 - Material |
Material |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1.0 (Material) |
1000.0 |
|
|
| 1061 |
National Test House (ER), Kolkata
| CUSTOM/CRAYONS/2024 - CUSTOM/CRAYONS/2024 |
CUSTOM/CRAYONS/2024 |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1.0 (No. of Shades) |
500.0 |
|
| 2.0 (Material) |
500.0 |
|
| 3.0 (Colour) |
500.0 |
|
| 4.0 (Crayons Shape) |
500.0 |
|
| 5.0 (Crayon length) |
1000.0 |
|
| 6.0 (Crayon Diameter) |
1000.0 |
|
|
| 1062 |
National Test House (ER), Kolkata
| CUSTOM/ERASER/2024 - CUSTOM/ERASER/2024 |
CUSTOM/ERASER/2024 |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1.0 (Material) |
1000.0 |
|
| 2.0 (Dimension) |
1000.0 |
|
|
| 1063 |
National Test House (ER), Kolkata
| CUSTOM/PENCIL/2024 - CUSTOM/PENCIL/2024 |
CUSTOM/PENCIL/2024 |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1.0 (Material) |
1000.0 |
|
| 2.0 (Length) |
1000.0 |
|
|
| 1064 |
National Test House (ER), Kolkata
| CUSTOM/PENCIL BOX/2024 - CUSTOM/PENCIL BOX/2024 |
CUSTOM/PENCIL BOX/2024 |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1.0 (Material) |
1000.0 |
|
| 2.0 (Type) |
1000.0 |
|
| 3.0 (Dimension) |
1000.0 |
|
| 4.0 (Pattern) |
500.0 |
|
| 5.0 (Weight) |
1000.0 |
|
|
| 1065 |
National Test House (NR), Ghaziabad
| NTH/NR/RPPT/2024/FRP (2024) - Glass Fiber Reinforced Composite Material |
Glass Fiber Reinforced Composite Material |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Firm's Requirement (Density) |
2000.0 |
|
| Firm's Requirement (Hardness, Shore'D') |
2000.0 |
|
| Firm's Requirement (Identification of Polymer) |
5000.0 |
|
| Firm's Requirement (Tensile Strength) |
2000.0 |
|
| Firm's Requirement (Yield Strength @Tension) |
2000.0 |
|
|
| 1066 |
National Test House (NR), Ghaziabad
| NTH/NR/RPPT/2024/Plastic Granules (2024) - Plastic Granules |
Plastic Granules |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Firm's Requirements (Density) |
2000.0 |
|
| Firm's Requirement (Identification of Polymer) |
5000.0 |
|
| Firm's Requirement (Hardness, Shore'D') |
2000.0 |
|
|
| 1067 |
National Test House (ER), Kolkata
| ASTM D 1653 - Water Vapor Transmission |
Water Vapor Transmission |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Water Vapor Transmission) |
5000.0 |
|
|
| 1068 |
National Test House (NR), Ghaziabad
| 17531:2021 (2021) - PORTABLE ELECTRIC INDOOR AIR PURIFIER |
PORTABLE ELECTRIC INDOOR AIR PURIFIER |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5.1 (Clean Air Delivery Rate (CADR)) |
15000.0 |
|
| 5.2 (Capacity of Air Purifier and Room Size) |
10000.0 |
|
| 5.3 (Noise Level (Sound Power Level)) |
5000.0 |
|
| 5.4 (Power Consumption) |
3000.0 |
|
| 5.5 (Standby Power) |
3000.0 |
|
|
| 1069 |
National Test House (WR), Mumbai
| IS 4250 (1980) - Specification for domestic electric food - Mixers (Liquidizers And Grinders) (First Revision) |
Specification for domestic electric food - Mixers (Liquidizers And Grinders) (First Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 10 (Power Input and Current, is 4250 & IS 302-1) |
1000.0 |
|
| 13 (Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
1500.0 |
|
| 13 (Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
1500.0 |
|
| 16 (Insulation Resistance and Electric Strength at Operating Temperature: IS 302-1) |
1500.0 |
|
| 10 (Power Input and Current, is 4250 & IS 302-1) |
1000.0 |
|
| 13 (Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
1500.0 |
|
| 13 (Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
1500.0 |
|
| 10 (Power Input and Current, is 4250 & IS 302-1) |
1000.0 |
|
| 13 (Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
1500.0 |
|
| 13 (Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
1500.0 |
|
|
| 1070 |
National Test House (WR), Mumbai
| Portable LED Light Tower - Portable LED Light Tower |
Portable LED Light Tower |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| A (Dimensions) |
5000.0 |
|
| B (Telescopic Tower Mast Detail (Construction)) |
5000.0 |
|
| C (LED Luminaire) |
57000.0 |
|
| E (General Set Up Parameters) |
10000.0 |
|
| F (Photometric Parameters of System) |
10000.0 |
|
| G (Accessories and Packing) |
2000.0 |
|
| H (Genset Details) |
35000.0 |
|
| I (as per customer requirement) |
90000.0 |
|
|
| 1071 |
National Test House (SR), Chennai
| 6047 (2009) - Scouring products for utensil cleaning - Specification |
Scouring products for utensil cleaning - Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 4.2 (Retention on 250-micron IS Sieve) |
1200.0 |
|
| 4.2 (Active matter) |
1200.0 |
|
| 4.2 (Active (Reserve) alkalinity) |
1200.0 |
|
| 4.2 (Matter insoluble in alcohol) |
1200.0 |
|
| 4.2 (Moisture and volatile matter content at 105°C) |
2400.0 |
|
| 4.2 (Lather) |
1200.0 |
|
| 4.2 (Cleaning efficacy, number of plates cleaned per 5g of sample) |
1200.0 |
|
| 4.2 (Tough soil cleaning) |
1200.0 |
|
| 4.2 (Surface damage) |
1200.0 |
|
|
| 1072 |
National Test House (ER), Kolkata
| Custom Specification for Electrical Testing Laboratory ,NTH(ER),Salt Lake - Custom Specification for Electrical Testing Laboratory ,NTH(ER),Salt Lake |
Custom Specification for Electrical Testing Laboratory ,NTH(ER),Salt Lake |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| A10 (Custom Specification 10) |
100000.0 |
|
| A1 (Custom Specification 1) |
10000.0 |
|
| A2 (Custom Specification 2) |
20000.0 |
|
| A7 (Custom Specification 7) |
70000.0 |
|
| A5 (Custom Specification-A5) |
50000.0 |
|
|
| 1073 |
National Test House (SR), Chennai
| ASME B 29.1 (2011) - Precision Power Transmission Roller Chain |
Precision Power Transmission Roller Chain |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 3.3 (Dimensions, mm) |
2000.0 |
|
| 3.3 (Chain length, mm) |
1000.0 |
|
| 3.4.2 (Breaking load, kN) |
4000.0 |
|
|
| 1074 |
National Test House (SR), Chennai
| CUS/SR/MECH-54 (2024) - Standard Step Chain |
Standard Step Chain |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1.0 (Dimensions, mm) |
2000.0 |
|
| 2.0 (Chain length, mm) |
1000.0 |
|
| 3.0 (Breaking load, kN) |
4000.0 |
|
| 4.0 (Rockwell Hardness, HRC) |
10000.0 |
|
|
| 1075 |
National Test House (NWR), Jaipur
| IS 210 (2009) - Grey iron castings - Specification (First Revision) |
Grey iron castings - Specification (First Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 15 (Tensile Strength) |
2500.0 |
|
| 16 (Brinell Hardness) |
2000.0 |
|
| 6 (Chemical Composition (Sulphur)) |
500.0 |
|
| 6 (Chemical Composition (Phosphorus)) |
1000.0 |
|
|
| 1076 |
National Test House (ER), Kolkata
| ND Custom 10 (2024) - Load Bearing Capacity for RCPC Slabs |
Load Bearing Capacity for RCPC Slabs |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Firm's Requirement (Load Bearing Capacity Test) |
3000.0 |
|
|
| 1077 |
National Test House (NR), Ghaziabad
| NTH/NR/XR/EPDM/01 (2024) - Customized Specification for EPDM Rubber Sheet |
Customized Specification for EPDM Rubber Sheet |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Firm's Requirement (Thickness) |
1000.0 |
|
| Firm's Requirment (Breaking Strength (Grab Test Method)) |
2000.0 |
|
| Firm's Requirment (Breaking Strength (Cut Strip Method)) |
2000.0 |
|
| Firm's Requirement (Tearing Resistance (Tounge Tear Test)) |
2000.0 |
|
| Firm's Requirement (Elongation@break) |
2000.0 |
|
| Firm's Requirement (Resistance to Water Absorption) |
5000.0 |
|
| Firm's Requirement (Heat Resistance Properties) |
5000.0 |
|
|
| 1078 |
National Test House (NR), Ghaziabad
| EN 12225:2019 (2019) - Geosynthetics - Method for determining the microbiological resistance by a soil burial test |
Geosynthetics - Method for determining the microbiological resistance by a soil burial test |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Cl. 8.2 (Tensile Strength, before exposure) |
2000.0 |
|
| Cl. 8.2 (Tensile Strength, after exposure) |
17000.0 |
|
| Cl 8.2 (Visual Observation after exposure) |
1000.0 |
|
|
| 1079 |
National Test House (NWR), Jaipur
| MMDTS-22001 - Technical Requirements of Anodized Aluminium Braille Stickers for Signage on Railway coaches |
Technical Requirements of Anodized Aluminium Braille Stickers for Signage on Railway coaches |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Heat Resistance at 120 deg. C for 3 hours) |
1200.0 |
|
| 2 (Ease of Cleaning) |
1500.0 |
|
|
| 1080 |
National Test House (WR), Mumbai
| Customized Specification for HVN Liners - Customized Specification for HVN Liners |
Customized Specification for HVN Liners |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| - (Specific Gravity as per BS EN ISO 1183-1:2019) |
1000.0 |
|
| - (Ash Contents as per Appendix III B) |
2000.0 |
|
| - (Tensile Strength as per ASTM D 638-14) |
2000.0 |
|
| - (Elongation at Break %) |
2000.0 |
|
| - (Dielectric Strength as per ASTM D 149-20) |
2000.0 |
|
| - (Volume Resistivity as per BS ISO 14309:2019) |
3000.0 |
|
| - (Flexural Strength as per Appendix X) |
2000.0 |
|
| - (Flexural Modulus as per ASTM D 790) |
3000.0 |
|
|