| 3721 |
National Test House (SR), Chennai
| IS 14252 (2015) - Textiles – High density polyethylene (HDPE)/ polypropylene (PP) woven sack for filling sand – Specification (second revision) |
Textiles – High density polyethylene (HDPE)/ polypropylene (PP) woven sack for filling sand – Specification (second revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 4 (Avg. Breaking Strength of fabric after UV exposure) |
2000.0 |
|
| 4 (Elongation at break of fabric, Widthwise) |
500.0 |
|
| 4 (Elongation at break of fabric, Lengthwise) |
500.0 |
|
| 4 (Average Breaking Strength of bottom seam) |
2000.0 |
|
| 4 (Avg. Breaking Strength of fabric, Widthwise) |
1000.0 |
|
| 4 (Avg. Breaking Strength of fabric, Lengthwise) |
1000.0 |
|
| 4 (Mass of Sack (without tying cord)) |
1000.0 |
|
| 4 (Picks/dm) |
500.0 |
|
| 4 (Ends/dm) |
500.0 |
|
| 4 (Dimensions, Outside Width) |
500.0 |
|
| 4 (Dimensions, Outside Length) |
500.0 |
|
| 4 (Mass of Bale) |
2000.0 |
|
| 3.3 (Tying cord Material Identification) |
2000.0 |
|
| 3.4.1 (Mouth of Sack, Channel secured with ) |
2000.0 |
|
| 3.4.1 (Mouth of Sack, Channel withturn-in) |
2000.0 |
|
| 3.4.1 (Mouth of Sack, Channel width) |
2000.0 |
|
| 3.4.1 (Bottom Seam, Number of Stitchs per dm) |
2000.0 |
|
| 3.4.1 (Bottom Seam, Double fold seam depth) |
2000.0 |
|
| 3.4.1 (Bottom Seam, Outer stitch distance from outer edge) |
2000.0 |
|
| 3.4.1 (Bottom Seam, Two row separation distance) |
2000.0 |
|
|
| 3722 |
National Test House (NWR), Jaipur
| IS 12406 (2021) - Medium density fibre boards for general purpose - Specification (First Revision) |
Medium density fibre boards for general purpose - Specification (First Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 9, Table 3 and 4, Table 3 & 4, Sl. No. (iii) & (iv) (Moisture Content-IS 2380 (Part 3): 1977) |
1000.0 |
|
| 8, Table 2 (Dimension & Tolerances-IS 12406:2021, Annex A) |
500.0 |
|
| 9, Table 3 and 4, Table 3 & 4, Sl. No. (iii) & (iv) (Moisture Content-IS 2380 (Part 3): 1977) |
1000.0 |
|
| 9, Table 3 & 4, Sl. No. (i) & (ii) (Density-IS 2380 (Part 3): 1977) |
500.0 |
|
| 9, Table 3 and 4, Sl No (xi) (Formaldehyde content-IS 13745:1993.) |
3000.0 |
|
| 9, Table 3 and 4, Sl. No. (v) (Linear Expansion (thickness swelling of water) due to general absorption after 24 hr soaking -IS 2380 (Part17): 1977) |
1000.0 |
|
| 9, Table 3 and 4, Sl No (ix) (Modulus of Elasticity-IS 2380 (Part 4): 1977) |
2000.0 |
|
| 9, Table 3 and 4, Sl No (viii) (Modulus of Rupture -IS 2380 (Part 4): 1977) |
2500.0 |
|
| 9, Table 3 and 4, Sl No (vi) (Internal Bond Strength-IS 2380 (Part 5): 1977) |
2000.0 |
|
| 9, Table 3 and 4, Sl No (vii) (Internal Bond strength after cyclic/accelerated water resistance test-IS 12406:2021 & IS 2380 (Part 5): 1977) |
2000.0 |
|
| 9, Table 3 and 4, Sl No (x) (Screw Withdrawal Strength-IS 2380 (Part 14): 1977) |
1500.0 |
|
|
| 3723 |
National Test House (NWR), Jaipur
| IS 10262 (2019) - Concrete Mix Proportioning — Guidelines ( Second Revision ) |
Concrete Mix Proportioning — Guidelines ( Second Revision ) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 4 (Concrete Mix Design (IS 10262:2019)) |
35000.0 |
|
|
| 3724 |
National Test House (NWR), Jaipur
| IS 8419 : Part 1 (1977) - Requirements for filtration equipment: Part 1 filtration media - Sand and gravel |
Requirements for filtration equipment: Part 1 filtration media - Sand and gravel |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 3.1.2 (Percentage of volume of sand (clay, slit, loam etc.)) |
1000.0 |
|
| 3.1.4 (Loss on Ignition) |
1000.0 |
|
| 3.1.1 (Silica) |
1000.0 |
|
| 3.1.3 (Acid Soluble Matter) |
1000.0 |
|
|
| 3725 |
National Test House (NWR), Jaipur
| IS 4990 (2011) - Plywood for concrete shuttering works - Specification (Third Revision) |
Plywood for concrete shuttering works - Specification (Third Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 10.1.1 (Moisture content-IS 4990:2011 & IS 1734 (Part 1):1983) |
1000.0 |
|
| 8 (Workmanship & Finish- IS 4990:2011,) |
1000.0 |
|
| 7 (Dimension and Tolerances- IS 4990:2011, Annex C) |
1000.0 |
|
| 10.1.2.1 (Glue Shear Strength in dry state-IS 1734 (Part 4):1983) |
2000.0 |
|
| 10.1.2.2 (Adhesion of Plies in dry state-IS 1734 (Part 5):1983) |
1000.0 |
|
| 10.1.3.1.1 (Glue Shear Strength, after Water Resistance-IS 4990:2011 & IS 1734 (Part 4):1983) |
2000.0 |
|
| 10.1.3.1.2 (Glue Adhesion, after, after water resistance-IS 4990:2011 & IS 1734 (Part 5):1983) |
500.0 |
|
| 10.1.5.1 (Glue Shear Strength, after Mycological Test-IS 1734 (Part 7):1983 & IS 1734 (Part 4):1983) |
2000.0 |
|
| 10.1.5.2 (Glue Adhesion, after Mycological Test-IS 1734 (Part 7):1983 & IS 1734 (Part 5):1983 -) |
500.0 |
|
| 10.1.5.1 (Glue Shear Strength, after Mycological Test-IS 1734 (Part 7):1983 & IS 1734 (Part 4):1983) |
2000.0 |
|
| 10.1.6 (Tensile Strength-IS 1734 (Part 9):1983) |
2500.0 |
|
| 10.1.7, Table 2 (Static Bending Strength-IS 1734 (Part 11):1983) |
2000.0 |
|
| 10.1.8, Table 3 (Wet Bending Strength--IS 4990:2011 & IS 1734 (Part 11):1983) |
2000.0 |
|
|
| 3726 |
National Test House (NWR), Jaipur
| IS 4457 (2007) - Ceramic unglazed vitreous acid resisting tiles - Specification (Second Revision) |
Ceramic unglazed vitreous acid resisting tiles - Specification (Second Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 4 (Water Absorption) |
1000.0 |
|
| 2 ( Surface Quality) |
500.0 |
|
| 3 (Dimension-Length) |
1000.0 |
|
| 4 (Abrasion resistance) |
2500.0 |
|
| 4 (Modulus of rupture) |
2000.0 |
|
| 4 (Warpage) |
1000.0 |
|
| 4 (Breaking Strength) |
2000.0 |
|
|
| 3727 |
National Test House (NWR), Jaipur
| IS 3466 (1988) - Specification For Masonry Cement |
Specification For Masonry Cement |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 3 (Fineness) |
1000.0 |
|
| 3 (Compressive strength,7 days) |
1250.0 |
|
| 3 (Compressive strength,28 days) |
1250.0 |
|
| 3 (Soundness-Lechatlier method) |
500.0 |
|
| 3 (Soundness-autoclave method) |
1000.0 |
|
| 3 (Setting time Initial) |
250.0 |
|
| 3 (Setting time,Final) |
250.0 |
|
| 3 (Fineness) |
1000.0 |
|
|
| 3728 |
National Test House (NWR), Jaipur
| IS 3316 (1974) - Structural Granite |
Structural Granite |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 3.3 (Water Absorption) |
1000.0 |
|
| 3.2 (Specific Gravity) |
1000.0 |
|
| 3.1 (Compressive Strength) |
2000.0 |
|
|
| 3729 |
National Test House (NER), Guwahati
| IS 16186 (2014) - Textiles - Light weight jute sacking bags for packing 50 kg foodgrains - Specification |
Textiles - Light weight jute sacking bags for packing 50 kg foodgrains - Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5.1(vi) (Seam Strength) |
1000.0 |
|
| 5.1(v) (Breaking Load,Weftway) |
1000.0 |
|
| 5.1(v) (Breaking Load,Warpway) |
1000.0 |
|
| 5.1(iv) (Corrected Mass) |
1000.0 |
|
| 5.1(iii) (Picks/dm) |
1000.0 |
|
| 5.1(ii) (Ends/dm) |
1000.0 |
|
| 5.1(i) (Outside Width) |
1000.0 |
|
| 5.1(i) (Outside Length) |
1000.0 |
|
| 4.3 (Sitches/dm) |
1000.0 |
|
|
| 3730 |
National Test House (NWR), Jaipur
| IS 3097 (2006) - Veneered Particle Boards -Specification |
Veneered Particle Boards -Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 7 (Dimensions and Tolerances-IS 3097:2006, Annex C) |
500.0 |
|
| 9.1 a (Density-IS 2380 (Part 3):1977) |
500.0 |
|
| 9.1 b (Moisture Content-IS 2380 (Part 3):1977) |
1000.0 |
|
| 9.1 c (Water Absorption-IS 2380 (Part 16):1977) |
1000.0 |
|
| 9.1 d (Water Resistance Test--IS 3097:2006) |
1000.0 |
|
| 9.1 e (Swelling in Water-IS 2380 (Part 17):1977) |
2000.0 |
|
| 9.1 f (Adhesion of Plies-IS 3097:2006) |
500.0 |
|
| 9.1 g (Modulus of Rupture and Modulus of Elasticity-IS 2380 (Part 4):1977) |
2500.0 |
|
|
| 3731 |
National Test House (SR), Chennai
| IS 11652 (2017) - Textiles – High density polyethylene (HDPE)/ polypropylene (PP) woven sacks for packaging of 50 kg cement – Specification (third revision) |
Textiles – High density polyethylene (HDPE)/ polypropylene (PP) woven sacks for packaging of 50 kg cement – Specification (third revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5 (Elongation at break of fabric, Widthwise) |
2000.0 |
|
| 5 (Elongation at break of fabric, Lengthwise) |
2000.0 |
|
| 5 (Breaking Strength of Top &bottom seam) |
2000.0 |
|
| 5 (Avg. Breaking Strength of fabric, Widthwise) |
2000.0 |
|
| 5 (Avg. Breaking Strength of fabric, Lengthwise) |
2000.0 |
|
| 5 (Mass of Sack (Gusset Type)) |
2000.0 |
|
| 5 (Mass of Sack (Non-Gusset type)) |
2000.0 |
|
| 5 (Picks/dm) |
2000.0 |
|
| 5 (Ends/dm) |
2000.0 |
|
| 5.1 (Mass of Bale) |
2000.0 |
|
| 5 (Dimension, Depth of valve(Non-Gusset sack)) |
2000.0 |
|
| 5 (Dimension, Depth of valve(Gusset sack)) |
2000.0 |
|
| 5 (Dimension, Width of valve) |
2000.0 |
|
| 5 (Dimension, Width of Sack inside) |
2000.0 |
|
| 5 (Dimension, Length of Sack inside) |
2000.0 |
|
| 4.4 (Seam Stitch, Number of Stitchs per dm) |
2000.0 |
|
| 4.4 (Seam Stitch, Double fold seam depth) |
2000.0 |
|
| 4.4 (Seam Stitch, Outer stitch distance from outer edge) |
2000.0 |
|
| 4.4 (Top & Bottom Seam Stitching, Two row separation distance) |
2000.0 |
|
|
| 3732 |
National Test House (NWR), Jaipur
| IS 3087 (2005) - Practicle boards of wood and other lingnocellulosic materials (medium density) for general purposes -Specification |
Practicle boards of wood and other lingnocellulosic materials (medium density) for general purposes -Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 8 and 11.2 (Dimensions and Tolerances-IS 2380 (Part 2):1977) |
500.0 |
|
| 9.1 & 11.3, Table 1, Sl No.(i) (Density-IS 2380 (Part 3):1977) |
500.0 |
|
| 9.2 & 11.4 (Moisture content-IS 2380 (Part 3):1977) |
1000.0 |
|
| 9.3 & 11.5, Table 1, Sl No.(ii) (Water Absorption-IS 2380 (Part 16):1977) |
1000.0 |
|
| 9.4 & 11.6, Table 1, Sl No.(iii) & (iv) (Swelling in water-IS 2380 (Part 17):1977) |
1500.0 |
|
| 9.5 & 11.7Table 1, Sl No.(v) , (Swelling due to surface absorption-IS 2380 (Part 17):1977) |
2000.0 |
|
| 11.8, Table 1, Sl No.(vi) & (vii) (Modulus of Rupture and Modulus of Elasticity-IS 2380 (Part 4):1977) |
2500.0 |
|
| 11.9, Table 1, Sl No.(viii) (Tensile strength perpendicular to surface-IS 2380 (Part 5):1977) |
2000.0 |
|
| 11.9.1, Table 1, Sl No.(ix), a & b (Tensile strength perpendicular to surface after cyclic/accelerated water resistance test-IS 2380 (Part 5):1977) |
2000.0 |
|
| 11.10, Table 1, Sl No.(x) (Screw Withdrawal Strength-IS 2380 (Part 14):1977) |
1500.0 |
|
|
| 3733 |
National Test House (NWR), Jaipur
| IS 2691 (2017) - Burnt Clay Facing Bricks - Specification (Third Revision) |
Burnt Clay Facing Bricks - Specification (Third Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6.3 (Efflorescence IS 3495(2)) |
1000.0 |
|
| 6.4 (Warpage IS 3495(4)) |
500.0 |
|
| 6.2 (Water Absorption IS 3495(2)) |
1000.0 |
|
| 4 (General quality IS 2691) |
500.0 |
|
| 6.1 (Compressive Strength IS 3495(1)) |
2000.0 |
|
| 5 (Dimensions & Tolerances S 2691) |
500.0 |
|
|
| 3734 |
National Test House (NWR), Jaipur
| IS 2645 (2003) - Integral waterproofing compounds for cement mortar and concrete - Specification (Second Revision) |
Integral waterproofing compounds for cement mortar and concrete - Specification (Second Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 3.2.a (Setting Time (Initial Setting Time)) |
500.0 |
|
| 3.2.b (Setting Time (Final Setting Time)) |
500.0 |
|
| 3.3.a (Compressive Strength-3 days) |
2000.0 |
|
| 3.1 (Permeability to Water) |
3000.0 |
|
|
| 3735 |
National Test House (NWR), Jaipur
| IS 2222 (1991) - Specification for burnt clay perforated building bricks (Third Revision) |
Specification for burnt clay perforated building bricks (Third Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 4 (General quality) |
500.0 |
|
| 5 (Dimensions & Tolerances) |
500.0 |
|
| 6 (Perforations) |
500.0 |
|
| 7.1 (Compressive Strength) |
2000.0 |
|
| 7.2 (Water Absorption) |
1000.0 |
|
| 7.3 (Efforescence) |
1000.0 |
|
| 7.4 (Warpage) |
500.0 |
|
|
| 3736 |
National Test House (NWR), Jaipur
| IS 2202 : Part 2 (1983) - Wooden Flush Door Shutters (solid Core Type): Part 2 Particle Board And Hardboard Face Panels |
Wooden Flush Door Shutters (solid Core Type): Part 2 Particle Board And Hardboard Face Panels |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 7 (Workmanship and Finish-IS 2202 (Part 1):1999) |
1000.0 |
|
| 8.1 & 11.1 (Dimensions and Squareness-IS 4020 (Part 2):1998) |
2000.0 |
|
| 11.2 (General Flatness-IS 4020 (Part 3):1998) |
1000.0 |
|
| 11.3 (Local planeness Test-IS 4020 (Part 4):1998) |
1000.0 |
|
| 11.4 (Impact Indentation-IS 4020 (Part 5):1998) |
1000.0 |
|
| 11.5 (Flexure Test-IS 4020 (Part 6):1998) |
1000.0 |
|
| 11.6 (Edge loading test-IS 4020 (Part 7):1998) |
1500.0 |
|
| 11.7 (Shock Resistance test-IS 4020 (Part 8):1998) |
1500.0 |
|
| 11.8 (Buckling Test-IS 4020 (Part 9):1998) |
1500.0 |
|
| 11.9 (Slamming Test-IS 4020 (Part 10):1998) |
1000.0 |
|
| 11.10 (Misuse Test-IS 4020 (Part 11):1998) |
1000.0 |
|
| 11.11 (Varing Humidity Test-IS 4020 (Part 12):1998) |
3000.0 |
|
| 11.12 (End Immersion Test-IS 4020 (Part 13):1998) |
1000.0 |
|
| 11.13 (Knife test-IS 4020 (Part 14):1998) |
1000.0 |
|
| 11.14 (Glue Adhesion Test-IS 4020 (Part 15):1998) |
1000.0 |
|
| 11.15 (Screw Withdrawal Resistance Test-IS 4020 (Part 16):1998) |
1000.0 |
|
|
| 3737 |
National Test House (NWR), Jaipur
| IS 2202 : Part 1 (2023) - Wooden flush door shutters (Solid Core Type) - Specification: Part 1 plywood face panels (Sixth Revision) |
Wooden flush door shutters (Solid Core Type) - Specification: Part 1 plywood face panels (Sixth Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 11.9.2 or 11.9.3 (Slamming Test-Cl 2.1 or 3.1 of IS 4020 (Part 10):1998) |
1000.0 |
|
| 11.10 (Misuse Test-IIS 4020 (Part 11):1998) |
1000.0 |
|
| 11.12 (End Immersion Test-IS 4020 (Part 13):1998 for BWP and 3cycle for MR) |
1000.0 |
|
| 11.13 (Knife test-IS 4020 (Part 14):1998) |
1000.0 |
|
| 11.15 (Screw Withdrawal Resistance Test-IS 4020 (Part 16):1998) |
1500.0 |
|
| 11.14 (Glue Adhesion Test-IS 4020 (Part 15):1998 for BWP and (60± 2)°C for MR) |
1000.0 |
|
| 9 (Workmanship and Finish-IS 2202 (Part 1):1999) |
1000.0 |
|
| 11.1 (Dimensions and Squareness-IS 4020 (Part 2):1998) |
2000.0 |
|
| 11.2 (General Flatness-IS 4020 (Part 3):1998) |
1000.0 |
|
| 11.3 (Local planeness Test-IS 4020 (Part 4):1998) |
1000.0 |
|
| 11.4 (Impact Indentation-IS 4020 (Part 5):1998) |
1000.0 |
|
| 11.5 (Flexure Test-IS 4020 (Part 6):1998) |
1000.0 |
|
| 11.6 (Edge loading test-IS 4020 (Part 7):1998) |
1500.0 |
|
| 11.7.1 and 11.7.2 (Shock Resistance test- Cl 2.1 & 3.1 of IS 4020 (Part 8):1998) |
1500.0 |
|
| 11.8 (Buckling Test-IS 4020 (Part 9):1998) |
1500.0 |
|
| 11.11 (Varying Humidity Test-IS 4020 (Part 12):1998) |
3000.0 |
|
|
| 3738 |
National Test House (NWR), Jaipur
| IS 2185 : Part 3 (1984) - Concrete Masonry Units Part 3 Autoclaved Cellular Aerated Concrete Blocks |
Concrete Masonry Units Part 3 Autoclaved Cellular Aerated Concrete Blocks |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 8.1 (General ) |
500.0 |
|
| 8.3 (Block Density, kg/m³) |
1000.0 |
|
| 8.4 (Compressive Strength, in N/mm²) |
12000.0 |
|
| 8.6 (Drying Shrinkage, in %) |
1000.0 |
|
| 8.2 (Dimensions (Length, width and thickness)) |
3000.0 |
|
|
| 3739 |
National Test House (NWR), Jaipur
| IS 2185 : Part 1 (2005) - Concrete masonry units - Specification: Part 1 hollow and solid concrete blocks (Third Revision) |
Concrete masonry units - Specification: Part 1 hollow and solid concrete blocks (Third Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 9.1 (General -IS 2185 : Part 1) |
500.0 |
|
| 9.3 & 5 (Block Density-Annex C of -IS 2185 : Part 1) |
1000.0 |
|
| 9.4 & Table2 (Compressive Strength-Annex D of -IS 2185 : Part 1) |
4000.0 |
|
| 9.5 (Water Absorption-Annex E of -IS 2185 : Part 1) |
1000.0 |
|
| 9.6 (Drying Shrinkage-Annex F of -IS 2185 : Part 1) |
2000.0 |
|
| 9.7 (Moisture movement-Annex G of -IS 2185 : Part 1) |
1000.0 |
|
| 9.2, 4.2.3 & Table 1 (Dimensions-Annex B of -IS 2185 : Part 1) |
500.0 |
|
|
| 3740 |
National Test House (NER), Guwahati
| IS 15138 (2010) - Textiles – Jute bags for packing 50 kg sugar – Specification (first revision) |
Textiles – Jute bags for packing 50 kg sugar – Specification (first revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5.1(vi) (Seam Strength,Weft way) |
1000.0 |
|
| 5.1(vi) (Seam Strength,Warp way) |
1000.0 |
|
| 5.1(v) (Breaking Load,Weftway) |
1000.0 |
|
| 5.1(v) (Breaking Load,Warpway) |
1000.0 |
|
| 5.1(iv) (Mass of Liner) |
1000.0 |
|
| 5.1(iv) (Corrected Mass) |
1000.0 |
|
| 5.1(iii) (Picks/dm) |
1000.0 |
|
| 5.1(ii) (Ends/dm) |
1000.0 |
|
| 5.1(i) (Outside Width) |
1000.0 |
|
| 5.1(i) (Outside Length) |
1000.0 |
|
| 4.2 (Sitches/dm) |
1000.0 |
|
|
| 3741 |
National Test House (NWR), Jaipur
| IS 2180 (1988) - Specification for heavy duty burnt clay building bricks (Third Revision) |
Specification for heavy duty burnt clay building bricks (Third Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6.3 (Efforescence) |
1000.0 |
|
| 4 (General quality) |
500.0 |
|
| 6.2 (Water Absorption) |
1000.0 |
|
| 6.1 (Compressive Strength) |
2000.0 |
|
| 6.4 (Bulk Density) |
500.0 |
|
| 5 (Dimensions & Tolerances) |
500.0 |
|
|
| 3742 |
National Test House (NWR), Jaipur
| IS 1659 (2004) - Block boards - Specification (Fourth Revision) |
Block boards - Specification (Fourth Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 9.2.2 (Water Resistance Test -IS 1659:2004, Clause 8.2.3 & Annex F and G) |
2000.0 |
|
| 9.2.3 (Adhesion of Plies-IS 1659:2004, Clause 8.2.3 & Annex G) |
1000.0 |
|
| 9.2.4 (Mycological Tests-IS 1659:2004, Clause 8.2.3 & Annex H) |
2000.0 |
|
| 9.2.6 (Spot Test-IS 1659:2004, Clause 8.2.3 & Annex K) |
2000.0 |
|
| 7, 8.1.4, and 8.1.5 (Dimension & Tolerances-IS 1659:2004, Annex D) |
1000.0 |
|
| 9.2.1 (Dimensional Changes caused by Humidity-IS 1659:2004, Clause 8.2.3 & Annex E) |
1000.0 |
|
| 9.2.5 (Modulus of Rupture & Modulus of Elasticity-IS 1659:2004, Clause 8.2.3 & Annex J) |
2000.0 |
|
| 8.1.3 (Defects--IS 1659:2004, Clause 6.3.3 and IS 303 / IS 1328) |
1000.0 |
|
|
| 3743 |
National Test House (NWR), Jaipur
| IS 1328 (1996) - Veneered Decorative Plywood -Specification |
Veneered Decorative Plywood -Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 11.1.1 (Moisture Content IS 1734 (Part 1):1983) |
1000.0 |
|
| 11.1.2 (Water Resistance test--IS 1328:1996) |
2000.0 |
|
| 8 (Dimension and tolerances-IS 1328:1996) |
1000.0 |
|
|
| 3744 |
National Test House (NWR), Jaipur
| IS 1130 (1969) - Marble (blocks, Slabs And Tiles) |
Marble (blocks, Slabs And Tiles) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 7 (Moisture Absorption (as per 1124), %) |
1000.0 |
|
| 7 (Hardness) |
2000.0 |
|
| 7 (Specific Gravity) |
1000.0 |
|
|
| 3745 |
National Test House (NWR), Jaipur
| IS 1077 (1992) - Common burnt clay building bricks - Specification (Fifth Revision) |
Common burnt clay building bricks - Specification (Fifth Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5 (GENERAL QUALITY IS 1077 : 1992) |
500.0 |
|
| 7.1 (Compressive Strength-IS 3495 (Part 1) : 2019) |
2000.0 |
|
| 7.2 (Water Absorption IS 3495 (Part 2) : 2019) |
1000.0 |
|
| 7.3 (Efflorescence IS 3495 (Part 3) : 2019) |
1000.0 |
|
| 6 (DIMENSIONS AND TOLERANCES-IS 1077 : 1992) |
500.0 |
|
|
| 3746 |
National Test House (NWR), Jaipur
| IS 710 (2010) - Marine plywood - Specification (Second Revision) |
Marine plywood - Specification (Second Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 9.1.8 (ACC (acid-copper-chrome)) |
3000.0 |
|
| 9.1.8 (CCB (copper-chrome-boron)) |
3000.0 |
|
| 9.1.8 (CCA(Copper-chrome-arsenic)) |
4000.0 |
|
|
| 3747 |
National Test House (NER), Guwahati
| IS 1161 (2014) - Steel tubes for structural purposes - Specification (Fifth Revision) |
Steel tubes for structural purposes - Specification (Fifth Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 11.3.2 (Flattening Test above 50 mm NB) |
1000.0 |
|
| 11.2 (Percentage Elongation, %) |
1000.0 |
|
| 11.2 (Yield Strength, MPa) |
1000.0 |
|
| 11.2 (Tensile Strength, MPa) |
1000.0 |
|
| 6 (Mass per meter, kg/m) |
1000.0 |
|
| 5 (Chemical Composition) |
2500.0 |
|
| 6 (Thickness, mm) |
500.0 |
|
| 6 (Outside diameter, mm) |
500.0 |
|
|
| 3748 |
National Test House (NWR), Jaipur
| IS 456 (2000) - Plain and reinforced concrete - WATER FOR CONSTRUCTION (Fourth Revision) |
Plain and reinforced concrete - WATER FOR CONSTRUCTION (Fourth Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5.4 (pH) |
500.0 |
|
| 5.4 (Volume (in ml) of 0.02 (N) H2SO4 required for Neutralization of 100 ml water using mixed indicator.) |
500.0 |
|
| 5.4 (Volume (in ml) of 0.02 (N) NaOH required for Neutralization of 100 ml water using phenolphthalein as an indicator.) |
500.0 |
|
| 5.4 (Suspended Matter) |
500.0 |
|
| 5.4 (Chlorides (as Cl)) |
1000.0 |
|
| 5.4 (Sulphates ( as SO3)) |
1000.0 |
|
| 5.4 (Total Inorganic Solids) |
500.0 |
|
| 5.4 (Total Organic Solids) |
500.0 |
|
| 5.4.1.2 (Test for Compressive strength (IS 516)) |
4000.0 |
|
| 5.4.1.3 (Initial setting time of test block with sample water compared with distilled water(IS 4031 (Part 5):1988) |
2000.0 |
|
|
| 3749 |
National Test House (NER), Guwahati
| IS 432 : Part 1 (1982) - Mild Steel and Medium Tensile Steel Bars and Hard-Drawn Steel Wire for Concrete Reinforcement: Part 1 Mild Steel and Medium Tensile Steel Bars |
Mild Steel and Medium Tensile Steel Bars and Hard-Drawn Steel Wire for Concrete Reinforcement: Part 1 Mild Steel and Medium Tensile Steel Bars |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 9.3 (Bend test) |
1000.0 |
|
| 9.2 (% Elongation) |
500.0 |
|
| 9.2 (Ultimate Tensile Stress) |
1000.0 |
|
| 6.1 (Dimensions) |
600.0 |
|
| 6 (Mass per meter) |
600.0 |
|
|
| 3750 |
National Test House (NER), Guwahati
| IS 4923 (2017) - Hollow steel sections for structural use - Specification (Third Revision) |
Hollow steel sections for structural use - Specification (Third Revision) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 15.2 (Elongation, %) |
1000.0 |
|
| 15.2 (Yield Strength, MPa) |
1000.0 |
|
| 15.2 (Tensile Strength, MPa) |
1000.0 |
|
| 9.1 (Dimension, mm) |
1000.0 |
|
| 9.1 (Weight, kg/m) |
1000.0 |
|
| 10.2 (Outside Dimension (B), mm) |
500.0 |
|
| 10.2 (Outside Dimension (H), mm) |
- |
|
| 10.3 (Thickness, mm) |
500.0 |
|
| 7.1 (Sulphur, % by mass) |
500.0 |
|
| 7.1 (Phosphorus, % by mass) |
500.0 |
|
|