211 |
IS 7014 (1973) - Specification for Length Bars |
Specification for Length Bars |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
7.4 (Length) |
9600.0 |
|
|
212 |
IS 11103 (1984) - Specification for Cylindrical Measuring Pins (Size Range from 0.1 mm up to and Including 20 mm) |
Specification for Cylindrical Measuring Pins (Size Range from 0.1 mm up to and Including 20 mm) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
7.1 (Diameter) |
7500.0 |
|
|
213 |
Custom - Used cooked oil |
Used cooked oil |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Moisture Content % by mass) |
1200.0 |
|
2 (Density) |
1200.0 |
|
3 (Free Fatty Acid) |
1200.0 |
|
4 (Kinematic Viscosity at Room Temp) |
1200.0 |
|
|
214 |
CUSTOM - Fly Ash |
Fly Ash |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Loss on Ignition) |
1200.0 |
|
2 (CaO) |
1200.0 |
|
3 (Fe2O3) |
1200.0 |
|
4 (MgO) |
1200.0 |
|
5 (Al2O3) |
1200.0 |
|
6 (SiO2) |
1200.0 |
|
|
215 |
IRS:TC 30-05 (2006) - Underground railway jelly filled telecom quad cables for signalling & telecom installations |
Underground railway jelly filled telecom quad cables for signalling & telecom installations |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
5.5.1 (Physical tests for conductor - Dimensions) |
500.0 |
|
5.7 (Test for thickness of insulation and sheaths) |
1000.0 |
|
5.8.2.3 (Physical tests for pe insulation, pe inner sheath, pvc intermediate and outer sheath - Shrinkage Test) |
500.0 |
|
5.9.3 (Conductor resistance test) |
1500.0 |
|
3.2.4 (Colour of insulated quad test) |
500.0 |
|
5.9.1 (High voltage test) |
3000.0 |
|
5.9.2.1 & 5.9.2.2 (Insulation Resistance Test) |
3000.0 |
|
5.6.1 (Physical test for armour tapes - Dimensions) |
1000.0 |
|
5.6.5 (Physical test for armour tapes - Test for closeness of armour) |
1000.0 |
|
- (Testing on extra core of 24 Quad Cable) |
46000.0 |
|
- (Testing of each extra core) |
2000.0 |
|
|
216 |
IS 13410 (1992) - Glass reinforced polyester sheet moulding compounds(Smc) - Specification |
Glass reinforced polyester sheet moulding compounds(Smc) - Specification |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
6.0 (Glass Content percent by mass) |
3000.0 |
|
6.0 (Izod Impact Strength) |
2000.0 |
|
6.0 (Tensile Strength) |
2000.0 |
|
6.0 (Flexural Strength) |
2000.0 |
|
|
217 |
IS 2095 : Part 1 (2011) - Gypsum Plaster Boards - Part 1 Plain Gypsum Plaster Boards |
Gypsum Plaster Boards - Part 1 Plain Gypsum Plaster Boards |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
7.3, Table3, 8.1 (Transverse Strength-IS: 2542 (Part 2/Sec 4)) |
4000.0 |
|
7.1, Table1 /Table2, 8.1 (Dimensions-IS: 2542 (Part 2/Sec 1)) |
500.0 |
|
7.2, 8.2 (Taper Profile-IS 2095 (1):2011) |
2000.0 |
|
|
218 |
B269-000-02-42-PCS-0001 Rev. 3 (2021) - F-15 Two components Epoxy phenolic coating cured with polyamine adduct hardener
EIL SPECIFICATION FOR SURFACE
PREPARATION AND PROTECTIVE COATING SYSTEM |
F-15 Two components Epoxy phenolic coating cured with polyamine adduct hardener
EIL SPECIFICATION FOR SURFACE
PREPARATION AND PROTECTIVE COATING SYSTEM |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Volume solids %) |
2000.0 |
|
2 (DFT per coat in microns) |
500.0 |
|
3 (Theoretical covering capacity meter square/coat/litre) |
500.0 |
|
4 (weight per litre of mix paint
Kg/litre) |
500.0 |
|
5 (Touch dry at 30 Deg C) |
500.0 |
|
6 (Hard dry at 30Deg C) |
500.0 |
|
7 (Full cure 30 Deg C(for immersion /high temp service)) |
500.0 |
|
8 (Over-coating interval) |
1000.0 |
|
9 (Pot life at 30 Deg C(For two components paint)) |
1000.0 |
|
10 (Adhesion (ASTM D 4541) MPa) |
3000.0 |
|
11 (Temperature Resistance
at 150 Deg C Method A ASTM D 2485) |
2500.0 |
|
|
219 |
EN 14399 Part-5 (2015) - High-strength structural bolting assemblies for Preloading –.Part 5: Plain washers |
High-strength structural bolting assemblies for Preloading –.Part 5: Plain washers |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
3 (Dimension) |
2000.0 |
|
4 & Table-3 (Mechanical Properties Vickers Hardness) |
2000.0 |
|
0 (Chemical Composition) |
2000.0 |
|
4.0 (Zinc coating thickness as per ISO 10684) |
2000.0 |
|
|
220 |
EN 14399 : Part 9 (2009) - High-Strength Structural Bolting Assemblies For Preloading - Part 9: System HR Or HV - Direct Tension Indicators For Bolt And Nut Assemblies |
High-Strength Structural Bolting Assemblies For Preloading - Part 9: System HR Or HV - Direct Tension Indicators For Bolt And Nut Assemblies |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
3.1 (Internal Diameter) |
500.0 |
|
3.1 (Protrusion internal Diameter) |
500.0 |
|
3.1 (Protrusion tangential Diameter) |
500.0 |
|
3.1 (Height of Protrusion) |
500.0 |
|
3.1 (Height over Protrusion) |
500.0 |
|
3.1 (Material Thickness) |
500.0 |
|
3.1 (External Diameter) |
500.0 |
|
3.1 (Dimensions as per EN 14399 - 9.) |
2500.0 |
|
3.2 (Mechanical Properties Vickers Hardness) |
2000.0 |
|
|
221 |
IS 277 (2018) - Galvanized Steel Sheets (Plain and Corrugated) |
Galvanized Steel Sheets (Plain and Corrugated) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
0 (Uniformity of Zinc Coating) |
2000.0 |
|
14 ,15 (Dimensions) |
1000.0 |
|
3.3 (Thickness of sheet (uncoated), mm) |
1000.0 |
|
5.1 (Carbon, % by mass) |
500.0 |
|
5.1 (Manganese, % by mass) |
500.0 |
|
5.1 (Sulphur, % by mass) |
500.0 |
|
5.1 (Phosphorous, % by mass) |
500.0 |
|
8.1 (Tensile Strength) |
2000.0 |
|
8.1 (Yield Stress) |
1000.0 |
|
8.1 (Elongation Percent) |
1000.0 |
|
8.2 (Bend Test) |
1000.0 |
|
12 (Freedom from Defects) |
1000.0 |
|
5.1 (Titanium) |
500.0 |
|
7 (Mass of Zinc Coating) |
2000.0 |
|
|
222 |
IS 1891 : Part 1 (2021) - CONVEYOR AND ELEVATOR TEXTILE BELTING – SPECIFICATION PART 1 GENERAL PURPOSE BELTING (Fifth Revision) |
CONVEYOR AND ELEVATOR TEXTILE BELTING – SPECIFICATION PART 1 GENERAL PURPOSE BELTING (Fifth Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
5.0 (Construction) |
1000.0 |
|
7.0 (Tensile Strength of Top Cover) |
1000.0 |
|
7.0 (Tensile Strength of Bottom Cover) |
1000.0 |
|
7.0 (Elongation at Break of Top Cover) |
500.0 |
|
7.0 (Elongation at Break of Bottom Cover) |
500.0 |
|
7.0 (Abrasion Loss of Top Cover) |
1500.0 |
|
7.0 (Abrasion loss of Bottom Cover) |
1500.0 |
|
8.0 (Freedom from Defects) |
1000.0 |
|
14.0 (Width) |
1000.0 |
|
14.0 (Cover Thickness) |
1000.0 |
|
15.0 (Full Thickness Tensile Strength, Longitudinal Direction) |
2500.0 |
|
15.0 (Full Thickness Tensile Strength, Transverse Direction) |
2500.0 |
|
15.0 (Full Thickness Elongation at Break, Longitudinal Direction) |
500.0 |
|
15.0 (Full Thickness Elongation at Break, Transverse Direction) |
500.0 |
|
15.0 (Elongation at Reference Load, Longitudinal Direction) |
1000.0 |
|
16.0 (Adhesion Strength Between Plies) |
3000.0 |
|
16.0 (Adhesion Strength Between Cover and Carcass) |
2000.0 |
|
Firm's request (Hardness (Shore A)) |
1000.0 |
|
|
223 |
CUSTOM - Grease |
Grease |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Consistency of the grease at 25±0.5°C,
Unworked penetration) |
1200.0 |
|
2 (Consistency of the grease at 25±0.5°C:
60 strokes) |
1200.0 |
|
3 (Free alkalinity, percent by mass) |
1200.0 |
|
|
224 |
CUSTOM - GOLD CONTENT (% by mass) |
GOLD CONTENT (% by mass) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Gold % by mass) |
2000.0 |
|
|
225 |
IS 9537 ( Part 3) (1983) - Specification for conduits for electrical installations ( Part 3) rigid plain conduits of insulating materials. |
Specification for conduits for electrical installations ( Part 3) rigid plain conduits of insulating materials. |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
7.0 (Dimensions) |
1000.0 |
|
8.0 (Construction) |
1000.0 |
|
9.3 (Compression Test) |
2000.0 |
|
11.0 (Resistance to Burning) |
5000.0 |
|
6.2 (Durability of Marking) |
1000.0 |
|
7.4 (Uniformity of Wall Thickness) |
1000.0 |
|
9.4 (Impact Test) |
2000.0 |
|
10.0 (Resistance to heat) |
2000.0 |
|
|
226 |
IS 14443 (1997) - Polycarbonate sheets - Specification |
Polycarbonate sheets - Specification |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
3.2.4 Table3 (Weight/Sq.M) |
1000.0 |
|
3.2.4 Table3 (Light Transmission) |
2000.0 |
|
3.2.2 (Identification of polymer) |
5000.0 |
|
3.2.2 (No of layers/Walls) |
500.0 |
|
3.2.2 (Profile) |
500.0 |
|
3.2.2 (Surface Texture) |
500.0 |
|
3.2.3 (Transparency) |
500.0 |
|
3.2.3 (Colour) |
500.0 |
|
3.2.4 (Flame Retardancy) |
5000.0 |
|
|
227 |
MMDTS19041 REV-02 DATE 01.01.2024 - - |
- |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
Cl 4 Table 1 Sr No 1 (Drying timeat25±2˚C a. Surface dry, max
IS:101-86 (Part3/Sec.1),
Reaffirmed 2017 or latest) |
250.0 |
|
Cl 4 Table 1 Sr No 1 (Drying time at2 5±2˚C b) Curing time
IS:101-86 (Part3/Sec.1),
Reaffirmed 2017 or latest) |
250.0 |
|
Cl 4 Table 1 Sr No 2 (Consistency
IS:101-89 (Part1/Sec.5),
Reaffirmed 2019 or latest) |
250.0 |
|
Cl 4 Table 1 Sr No 3 (Finish
IS:101-87 (Part 3/Sec.4),
Reaffirmed 2019 or latest) |
250.0 |
|
Cl 4 Table 1 Sr No 4 (Colour
IS:101-89 (Part 4/Sec.2),
Reaffirmed 2021 or latest) |
100.0 |
|
Cl 4 Table 1 Sr No 5 (Dry film thickness per coat,
by Spray
/dipping roller/wipes
IS:101-89 (Part3/Sec.2 )
Reaffirmed 2019 or latest version
ASTM D7091 (latest version)/by DFT gauge) |
250.0 |
|
Cl 4 Table 1 Sr No 7 (a )Scratch hardness(at1.5 Kg. load)
IS:101-88 (Part5/Sec.2),
Reaffirmed 2014 or Latest Version
b)Pencil Hardness test
ASTM D3363 or Latest Version) |
3500.0 |
|
Cl 4 Table 1 Sr No 8 (Flexibility & Adhesion (6.25 mm mandrel)
IS:101-88 (Part5/Sec.2),Reaffirmed 2014 or Latest Version) |
250.0 |
|
Cl 4 Table 1 Sr No 9 (Flash Point deg C
IS: 101-87(Part 1/ Sec.6),Reaffirmed 2019 or latest version) |
250.0 |
|
Cl 4 Table 1 Sr No 10 (Resistance to salt spray
For 3000 hours
ASTM B-117/2019 or latest version) |
125000.0 |
|
Cl 4 Table 1 Sr No 11 (Protection against
Corrosion under condition of
Condensation for 2500 hours
IS:101-88(Part6/Sec.1),Reaffirmed 2015 or latest) |
100000.0 |
|
Cl 4 Table 1 Sr No 13 (Spreading & Covering surface area Capacity, .@ DFT ≥5microns
Appendix-I of RDSO specification no. M&C/ PCN 100/ 2018) |
500.0 |
|
Cl 4 Table 1 Sr No 14 (Resistance to chemicals For 24 hours
1) 25% caustic soda solution (w/v)
2) 30% (V/V) H2SO4
IS:101-89 (Part7 /Sec.2) RA 2020 or latest) |
2000.0 |
|
Cl 4 Table 1 Sr No 15 (Mass in kg/ 10litres,
IS:101-87 (Part1/Sec.7)Reaffirmed 2020 or latest) |
500.0 |
|
Cl 4 Table 1 Sr No 16 (Impact resistance test
height 31 Inch, load 6.45pound (200 Inch pound load
ASTM2794-93 or latest) |
2000.0 |
|
Cl 4 Table 1 Sr No 17 (Resistance to tap Water or raw water for 3000 hours
IS: 101-90 (Part7/Sec.2)
Reaffirmed- 2005 or latest) |
7500.0 |
|
Cl 4 Table 1 Sr No 18 (Abrasion Resistance test 1000 cycle with CS-17 wheel & 1 kg load
ASTMD-4060 or latest) |
2500.0 |
|
Cl 4 Table 1 Sr No 19 (Glossat60 angle of incidence
IS:101-88 (Part 4/ Sec.4)
Reaffirmed-2020 or latest) |
1500.0 |
|
Cl 4 Table 1 Sr No20 (Anti-graffiti properties
ASTM D-6578/ 13 /(latest version)
Marker:Edding 3000) |
7500.0 |
|
Cl 4 Table 1 Sr No 21 (Durability Test–
Accelerated weathering test:
QUV 4 hours and 4 hours Condensation alternatively, (750hrs), Temp. 50 O C as per ASTM G154-or latest) |
25000.0 |
|
|
228 |
Meter Box Test as per customer requirement |
- |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Material Identification) |
4000.0 |
|
10 (Protection Against Electric shock) |
2000.0 |
|
13 (Protection against ingress of solid object (IP5X)) |
6000.0 |
|
13 (Protection against harmfull ingress of water (IPX5)) |
6000.0 |
|
18 (Glow wire test @ 650 Deg C (Resistance to heat and fire)) |
5000.0 |
|
19 (Resistance to tracking) |
5000.0 |
|
20 (Resistant to corrosion) |
5000.0 |
|
8 (Boiling Water) |
2000.0 |
|
9 (Tensile strength) |
2000.0 |
|
10 (Flexural strength) |
2000.0 |
|
11 (Modulus of Elasticity) |
2000.0 |
|
|
229 |
IS 2141 (2000) - Hot dip galvanized stay strand - Specification (Fourth Revision) |
Hot dip galvanized stay strand - Specification (Fourth Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
4 (Sulphur) |
500.0 |
|
4 (Phosphorus) |
500.0 |
|
6.2 (Breaking Force of Single Wire) |
2000.0 |
|
7 (Freedom from defect) |
1000.0 |
|
8.1 (Wrapping Test of wire) |
1000.0 |
|
9.1 (Breaking Force of Strand) |
3000.0 |
|
9.1 (Elongation of Strand) |
1000.0 |
|
8.1 (Wire Diameter) |
1000.0 |
|
9.2 (Mass of Zinc Coating) |
2000.0 |
|
|
230 |
IS 398 Part 2 RA 2018 (2018) - ALUMINIUM CONDUCTORS FOR OVERHEAD TRANSMISSION PURPOSES |
ALUMINIUM CONDUCTORS FOR OVERHEAD TRANSMISSION PURPOSES |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
3.3 (Direction of Lay) |
1000.0 |
|
3.3 (Measurement of Diameter of individual Aluminum Wires) |
3500.0 |
|
13.2 (Measurement of Diameter of Galvanized Steel Wires) |
1000.0 |
|
13.3 (Breaking Load Test of Wire) |
7000.0 |
|
13.4 (Ductility Test) |
1000.0 |
|
13.5 (Wrapping Test for Aluminum Wire) |
1000.0 |
|
13.6 (Resistance Test) |
2000.0 |
|
13.7 (Galvanizing Test) |
2000.0 |
|
13.8 (Lay Ratio) |
1000.0 |
|
7.1 (Freedom from defect) |
1000.0 |
|
9.2 (Joints in Aluminium Stranded Wires (Visual Examination)) |
1000.0 |
|
Annexure A-3 & Table 3 (Approximate breaking load of conductors) |
2000.0 |
|
|
231 |
IS 10647 (1983) - Specification for wheel bearing grease |
Specification for wheel bearing grease |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
2.3 (Consistency of the grease at 25+/- 0.5 degree C, 60 strokes) |
1200.0 |
|
2.3 (Drop Point) |
1200.0 |
|
2.3 (Copper strip corrosion test at 100 degree C for 24 hours) |
1200.0 |
|
2.3 (Water Content) |
1200.0 |
|
2.3 (consistency of grease, 25+/- 0.5 degree, unworked penetration) |
1200.0 |
|
2.3 (consistency of grease, 25+/- 0.5 degree, 10000 strokes) |
1200.0 |
|
|
232 |
IS 9537 : Part 3 (1983) - Specification for conduits for electrical installations: Part 3 rigid plain conduits of insulating meterials |
Specification for conduits for electrical installations: Part 3 rigid plain conduits of insulating meterials |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
11 (Resistance to Burning) |
2000.0 |
|
10 (Resistance to Heat) |
2000.0 |
|
9.5 (Collapse Test) |
2000.0 |
|
9.4 (Impact Test) |
2000.0 |
|
9.3 (Compression Test) |
2000.0 |
|
9.2 (Bending Test) |
2000.0 |
|
8 (Construction) |
1000.0 |
|
7.4 (Uniformity of Wall Thickness) |
1000.0 |
|
7 (Dimension) |
1000.0 |
|
9.4 (Visual) |
1000.0 |
|
6.4 (Durability of Marking) |
500.0 |
|
|
233 |
ASME BPVC Section V SE 165 - Standard Practice for Liquid Penetrant Examination for General Industry |
Standard Practice for Liquid Penetrant Examination for General Industry |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Flaw detection by Liquid Penetrant Test) |
1000.0 |
|
|
234 |
ASME BPVC Section V SD 7091 - Standard practice for Non-destructive measurement of Dry Film Thickness of Non-magnetic Coating applied to ferrous metals and Non-magnetic, Non-conductive coating applied to Non-ferrous Metals |
Standard practice for Non-destructive measurement of Dry Film Thickness of Non-magnetic Coating applied to ferrous metals and Non-magnetic, Non-conductive coating applied to Non-ferrous Metals |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Dry Film Thickness) |
2000.0 |
|
|
235 |
IS 13043 (1991) - Covered manual metal arc welding electrodes - Determination of efficiency, metal recovery and deposition co - Efficien |
Covered manual metal arc welding electrodes - Determination of efficiency, metal recovery and deposition co - Efficien |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Metal Recovery Test-Effective Electrode Efficiency) |
3000.0 |
|
|
236 |
IS 11802 (1986) - Methods for determination of diffusible hydrogen content of deposited weld metal from covered electrodes in welding mild and low alloy steels |
Methods for determination of diffusible hydrogen content of deposited weld metal from covered electrodes in welding mild and low alloy steels |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
5 (Volume of diffusible hydrogen) |
5000.0 |
|
|
237 |
IS 1608 (Part1): 2022 - Metallic Materials-Tensile Testing-Method of Test at Room Temperature |
Metallic Materials-Tensile Testing-Method of Test at Room Temperature |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Tensile Testing) |
5000.0 |
|
|
238 |
IS 1757 (PART 1): 2020 - Metallic Materials Charpy Pendulum Impact Test Part 1 Test Method |
Metallic Materials Charpy Pendulum Impact Test Part 1 Test Method |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Charpy Impact Test) |
3000.0 |
|
2 (Charpy Impact Test) |
5000.0 |
|
|
239 |
IS 1757 Part 1 (2020) - Metallic Materials — Charpy Pendulum Impact Test Part 1 Test Method ( Fourth Revision ) |
Metallic Materials — Charpy Pendulum Impact Test Part 1 Test Method ( Fourth Revision ) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
9 (Impact Test with sample preparation) |
5000.0 |
|
9 (Impact Test without sample preparation) |
4000.0 |
|
|
240 |
IS 3600 : Part 5 (2018) - Method of testing fusion welded joints and weld metal in steel: Part 5 destructive tests on welds in metallic materials - Bend tests (Third Revision) |
Method of testing fusion welded joints and weld metal in steel: Part 5 destructive tests on welds in metallic materials - Bend tests (Third Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (TRANSVERSE ROOT or FACE BEND TEST) |
1000.0 |
|
|