211 |
IS 9537 ( Part 3) (1983) - Specification for conduits for electrical installations ( Part 3) rigid plain conduits of insulating materials. |
Specification for conduits for electrical installations ( Part 3) rigid plain conduits of insulating materials. |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
7.0 (Dimensions) |
1000.0 |
|
8.0 (Construction) |
1000.0 |
|
9.3 (Compression Test) |
2000.0 |
|
11.0 (Resistance to Burning) |
5000.0 |
|
6.2 (Durability of Marking) |
1000.0 |
|
7.4 (Uniformity of Wall Thickness) |
1000.0 |
|
9.4 (Impact Test) |
2000.0 |
|
10.0 (Resistance to heat) |
2000.0 |
|
|
212 |
IS 14443 (1997) - Polycarbonate sheets - Specification |
Polycarbonate sheets - Specification |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
3.2.4 Table3 (Weight/Sq.M) |
1000.0 |
|
3.2.4 Table3 (Light Transmission) |
2000.0 |
|
3.2.2 (Identification of polymer) |
5000.0 |
|
3.2.2 (No of layers/Walls) |
500.0 |
|
3.2.2 (Profile) |
500.0 |
|
3.2.2 (Surface Texture) |
500.0 |
|
3.2.3 (Transparency) |
500.0 |
|
3.2.3 (Colour) |
500.0 |
|
3.2.4 (Flame Retardancy) |
5000.0 |
|
|
213 |
MMDTS19041 REV-02 DATE 01.01.2024 - - |
- |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
Cl 4 Table 1 Sr No 1 (Drying timeat25±2˚C a. Surface dry, max
IS:101-86 (Part3/Sec.1),
Reaffirmed 2017 or latest) |
250.0 |
|
Cl 4 Table 1 Sr No 1 (Drying time at2 5±2˚C b) Curing time
IS:101-86 (Part3/Sec.1),
Reaffirmed 2017 or latest) |
250.0 |
|
Cl 4 Table 1 Sr No 2 (Consistency
IS:101-89 (Part1/Sec.5),
Reaffirmed 2019 or latest) |
250.0 |
|
Cl 4 Table 1 Sr No 3 (Finish
IS:101-87 (Part 3/Sec.4),
Reaffirmed 2019 or latest) |
250.0 |
|
Cl 4 Table 1 Sr No 4 (Colour
IS:101-89 (Part 4/Sec.2),
Reaffirmed 2021 or latest) |
100.0 |
|
Cl 4 Table 1 Sr No 5 (Dry film thickness per coat,
by Spray
/dipping roller/wipes
IS:101-89 (Part3/Sec.2 )
Reaffirmed 2019 or latest version
ASTM D7091 (latest version)/by DFT gauge) |
250.0 |
|
Cl 4 Table 1 Sr No 7 (a )Scratch hardness(at1.5 Kg. load)
IS:101-88 (Part5/Sec.2),
Reaffirmed 2014 or Latest Version
b)Pencil Hardness test
ASTM D3363 or Latest Version) |
3500.0 |
|
Cl 4 Table 1 Sr No 8 (Flexibility & Adhesion (6.25 mm mandrel)
IS:101-88 (Part5/Sec.2),Reaffirmed 2014 or Latest Version) |
250.0 |
|
Cl 4 Table 1 Sr No 9 (Flash Point deg C
IS: 101-87(Part 1/ Sec.6),Reaffirmed 2019 or latest version) |
250.0 |
|
Cl 4 Table 1 Sr No 10 (Resistance to salt spray
For 3000 hours
ASTM B-117/2019 or latest version) |
125000.0 |
|
Cl 4 Table 1 Sr No 11 (Protection against
Corrosion under condition of
Condensation for 2500 hours
IS:101-88(Part6/Sec.1),Reaffirmed 2015 or latest) |
100000.0 |
|
Cl 4 Table 1 Sr No 13 (Spreading & Covering surface area Capacity, .@ DFT ≥5microns
Appendix-I of RDSO specification no. M&C/ PCN 100/ 2018) |
500.0 |
|
Cl 4 Table 1 Sr No 14 (Resistance to chemicals For 24 hours
1) 25% caustic soda solution (w/v)
2) 30% (V/V) H2SO4
IS:101-89 (Part7 /Sec.2) RA 2020 or latest) |
2000.0 |
|
Cl 4 Table 1 Sr No 15 (Mass in kg/ 10litres,
IS:101-87 (Part1/Sec.7)Reaffirmed 2020 or latest) |
500.0 |
|
Cl 4 Table 1 Sr No 16 (Impact resistance test
height 31 Inch, load 6.45pound (200 Inch pound load
ASTM2794-93 or latest) |
2000.0 |
|
Cl 4 Table 1 Sr No 17 (Resistance to tap Water or raw water for 3000 hours
IS: 101-90 (Part7/Sec.2)
Reaffirmed- 2005 or latest) |
7500.0 |
|
Cl 4 Table 1 Sr No 18 (Abrasion Resistance test 1000 cycle with CS-17 wheel & 1 kg load
ASTMD-4060 or latest) |
2500.0 |
|
Cl 4 Table 1 Sr No 19 (Glossat60 angle of incidence
IS:101-88 (Part 4/ Sec.4)
Reaffirmed-2020 or latest) |
1500.0 |
|
Cl 4 Table 1 Sr No20 (Anti-graffiti properties
ASTM D-6578/ 13 /(latest version)
Marker:Edding 3000) |
7500.0 |
|
Cl 4 Table 1 Sr No 21 (Durability Test–
Accelerated weathering test:
QUV 4 hours and 4 hours Condensation alternatively, (750hrs), Temp. 50 O C as per ASTM G154-or latest) |
25000.0 |
|
|
214 |
Meter Box Test as per customer requirement |
- |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Material Identification) |
4000.0 |
|
10 (Protection Against Electric shock) |
2000.0 |
|
13 (Protection against ingress of solid object (IP5X)) |
6000.0 |
|
13 (Protection against harmfull ingress of water (IPX5)) |
6000.0 |
|
18 (Glow wire test @ 650 Deg C (Resistance to heat and fire)) |
5000.0 |
|
19 (Resistance to tracking) |
5000.0 |
|
20 (Resistant to corrosion) |
5000.0 |
|
8 (Boiling Water) |
2000.0 |
|
9 (Tensile strength) |
2000.0 |
|
10 (Flexural strength) |
2000.0 |
|
11 (Modulus of Elasticity) |
2000.0 |
|
|
215 |
IS 2141 (2000) - Hot dip galvanized stay strand - Specification (Fourth Revision) |
Hot dip galvanized stay strand - Specification (Fourth Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
4 (Sulphur) |
500.0 |
|
4 (Phosphorus) |
500.0 |
|
6.2 (Breaking Force of Single Wire) |
2000.0 |
|
7 (Freedom from defect) |
1000.0 |
|
8.1 (Wrapping Test of wire) |
1000.0 |
|
9.1 (Breaking Force of Strand) |
3000.0 |
|
9.1 (Elongation of Strand) |
1000.0 |
|
8.1 (Wire Diameter) |
1000.0 |
|
9.2 (Mass of Zinc Coating) |
2000.0 |
|
|
216 |
IS 398 Part 2 RA 2018 (2018) - ALUMINIUM CONDUCTORS FOR OVERHEAD TRANSMISSION PURPOSES |
ALUMINIUM CONDUCTORS FOR OVERHEAD TRANSMISSION PURPOSES |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
3.3 (Direction of Lay) |
1000.0 |
|
3.3 (Measurement of Diameter of individual Aluminum Wires) |
3500.0 |
|
13.2 (Measurement of Diameter of Galvanized Steel Wires) |
1000.0 |
|
13.3 (Breaking Load Test of Wire) |
7000.0 |
|
13.4 (Ductility Test) |
1000.0 |
|
13.5 (Wrapping Test for Aluminum Wire) |
1000.0 |
|
13.6 (Resistance Test) |
2000.0 |
|
13.7 (Galvanizing Test) |
2000.0 |
|
13.8 (Lay Ratio) |
1000.0 |
|
7.1 (Freedom from defect) |
1000.0 |
|
9.2 (Joints in Aluminium Stranded Wires (Visual Examination)) |
1000.0 |
|
Annexure A-3 & Table 3 (Approximate breaking load of conductors) |
2000.0 |
|
|
217 |
IS 10647 (1983) - Specification for wheel bearing grease |
Specification for wheel bearing grease |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
2.3 (Consistency of the grease at 25+/- 0.5 degree C, 60 strokes) |
1200.0 |
|
2.3 (Drop Point) |
1200.0 |
|
2.3 (Copper strip corrosion test at 100 degree C for 24 hours) |
1200.0 |
|
2.3 (Water Content) |
1200.0 |
|
2.3 (consistency of grease, 25+/- 0.5 degree, unworked penetration) |
1200.0 |
|
2.3 (consistency of grease, 25+/- 0.5 degree, 10000 strokes) |
1200.0 |
|
|
218 |
IS 9537 : Part 3 (1983) - Specification for conduits for electrical installations: Part 3 rigid plain conduits of insulating meterials |
Specification for conduits for electrical installations: Part 3 rigid plain conduits of insulating meterials |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
11 (Resistance to Burning) |
2000.0 |
|
10 (Resistance to Heat) |
2000.0 |
|
9.5 (Collapse Test) |
2000.0 |
|
9.4 (Impact Test) |
2000.0 |
|
9.3 (Compression Test) |
2000.0 |
|
9.2 (Bending Test) |
2000.0 |
|
8 (Construction) |
1000.0 |
|
7.4 (Uniformity of Wall Thickness) |
1000.0 |
|
7 (Dimension) |
1000.0 |
|
9.4 (Visual) |
1000.0 |
|
6.4 (Durability of Marking) |
500.0 |
|
|
219 |
ASME BPVC Section V SE 165 - Standard Practice for Liquid Penetrant Examination for General Industry |
Standard Practice for Liquid Penetrant Examination for General Industry |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Flaw detection by Liquid Penetrant Test) |
1000.0 |
|
|
220 |
ASME BPVC Section V SD 7091 - Standard practice for Non-destructive measurement of Dry Film Thickness of Non-magnetic Coating applied to ferrous metals and Non-magnetic, Non-conductive coating applied to Non-ferrous Metals |
Standard practice for Non-destructive measurement of Dry Film Thickness of Non-magnetic Coating applied to ferrous metals and Non-magnetic, Non-conductive coating applied to Non-ferrous Metals |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Dry Film Thickness) |
2000.0 |
|
|
221 |
IS 13043 (1991) - Covered manual metal arc welding electrodes - Determination of efficiency, metal recovery and deposition co - Efficien |
Covered manual metal arc welding electrodes - Determination of efficiency, metal recovery and deposition co - Efficien |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Metal Recovery Test-Effective Electrode Efficiency) |
3000.0 |
|
|
222 |
IS 11802 (1986) - Methods for determination of diffusible hydrogen content of deposited weld metal from covered electrodes in welding mild and low alloy steels |
Methods for determination of diffusible hydrogen content of deposited weld metal from covered electrodes in welding mild and low alloy steels |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
5 (Volume of diffusible hydrogen) |
5000.0 |
|
|
223 |
IS 1608 (Part1): 2022 - Metallic Materials-Tensile Testing-Method of Test at Room Temperature |
Metallic Materials-Tensile Testing-Method of Test at Room Temperature |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Tensile Testing) |
5000.0 |
|
|
224 |
IS 1757 (PART 1): 2020 - Metallic Materials Charpy Pendulum Impact Test Part 1 Test Method |
Metallic Materials Charpy Pendulum Impact Test Part 1 Test Method |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Charpy Impact Test) |
3000.0 |
|
2 (Charpy Impact Test) |
5000.0 |
|
|
225 |
IS 1757 Part 1 (2020) - Metallic Materials — Charpy Pendulum Impact Test Part 1 Test Method ( Fourth Revision ) |
Metallic Materials — Charpy Pendulum Impact Test Part 1 Test Method ( Fourth Revision ) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
9 (Impact Test with sample preparation) |
5000.0 |
|
9 (Impact Test without sample preparation) |
4000.0 |
|
|
226 |
IS 3600 : Part 5 (2018) - Method of testing fusion welded joints and weld metal in steel: Part 5 destructive tests on welds in metallic materials - Bend tests (Third Revision) |
Method of testing fusion welded joints and weld metal in steel: Part 5 destructive tests on welds in metallic materials - Bend tests (Third Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (TRANSVERSE ROOT or FACE BEND TEST) |
1000.0 |
|
|
227 |
IS 3848:1981 - Method for end quench test for hardenability of steel (First Revision) |
Method for end quench test for hardenability of steel (First Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Hardenability Test) |
8000.0 |
|
|
228 |
IS 6416:2022 - Methods for Measuring Case Depth of Steel |
Methods for Measuring Case Depth of Steel |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
7 (Case Depth of Steel by Macrostructure Method) |
3000.0 |
|
8 (Case Depth of Steel by Microstructure Method) |
3000.0 |
|
|
229 |
ASTM E114-20 - Standard Practice for Ultrasonic Pulse-Echo Straight Beam Contact Testing |
Standard Practice for Ultrasonic Pulse-Echo Straight Beam Contact Testing |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Ultrasonic Pulse-Echo Straight Beam Contact Testing) |
1000.0 |
|
|
230 |
ASTM E164-19 - Standard Practice for Contact Ultrasonic Testing of Weldments |
Standard Practice for Contact Ultrasonic Testing of Weldments |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Ultrasonic Testing of Weldments) |
1000.0 |
|
|
231 |
ASTM E 94-17 - Standard Guide for Radiographic Examination using Industrial Radiographic Film |
Standard Guide for Radiographic Examination using Industrial Radiographic Film |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Radiographic Examination using Industrial Radiographic Film) |
1000.0 |
|
|
232 |
ASTM E1032-19 - Standard Practice for Radiographic Examination of Weldments using Industrial X-Ray Film |
Standard Practice for Radiographic Examination of Weldments using Industrial X-Ray Film |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Radiographic Examination of Weldments) |
1000.0 |
|
|
233 |
ASTM E1030-15 - Standard Practice for Radiographic Examination of Metallic Castings |
Standard Practice for Radiographic Examination of Metallic Castings |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Radiographic Examination of Metallic Castings) |
1000.0 |
|
|
234 |
IS 3664:1981 - Code of practice for ultrasonic pulse echo testing by contact and immersion methods (first revision) |
Code of practice for ultrasonic pulse echo testing by contact and immersion methods (first revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Ultrasonic Pulse Echo Testing by Contact Method) |
1000.0 |
|
|
235 |
ASTM E709-15 - Standard Guide for Magnetic Particle Testing |
Standard Guide for Magnetic Particle Testing |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Magnetic Particle Testing) |
1000.0 |
|
|
236 |
ASTM E112-13 - Standard Test Method for Determining Average Grain Size |
Standard Test Method for Determining Average Grain Size |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
10 (Determining Average Grain Size) |
3000.0 |
|
|
237 |
IS 7754 (Part 1) (2022) - Microstructure of Cast Iron-Graphite Classification by visual analysis |
Microstructure of Cast Iron-Graphite Classification by visual analysis |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
6 (Determination of Graphite Shape and Distribution) |
3000.0 |
|
|
238 |
IS 7754 (2022) - Microstructure of Cast Iron-Graphite Classification by Visual analysis |
Microstructure of Cast Iron-Graphite Classification by Visual analysis |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Microstructure of Graphite in Cast Iron) |
3000.0 |
|
|
239 |
CUSTOM - Chemical Composition of Galvalume Sheet |
Chemical Composition of Galvalume Sheet |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Aluminium, % by weight) |
1200.0 |
|
2 (Zinc, % by weight) |
1200.0 |
|
3 (Silicon, % by weight) |
1200.0 |
|
|
240 |
IRS:S88/2004 (2004) - LOW MAINTENANCE LEAD ACID STATIONARY SECONDARY CELLS FOR S&T INSTALLATIONS |
LOW MAINTENANCE LEAD ACID STATIONARY SECONDARY CELLS FOR S&T INSTALLATIONS |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
7.2 (Verification of constructional Requirements) |
500.0 |
|
7.3 (Verification of Marking) |
500.0 |
|
7.4 (Verification of dimension) |
500.0 |
|
7.5 (Test for Capacity) |
20000.0 |
|
7.6 (Test for loss of capacity on storage) |
10000.0 |
|
7.7 (Endurance Test) |
45000.0 |
|
7.8 (Ampere Hour & Watt Hour Efficiency Test) |
20000.0 |
|
7.9 (Test for voltage during discharge) |
5000.0 |
|
7.10 (Life Test) |
240000.0 |
|
7.11 (Storage Test) |
10000.0 |
|
7.12 (Water loss Test) |
5000.0 |
|
7.13 (Equilibrium Float Current Test) |
5000.0 |
|
7.14 (Sulphation Test) |
20000.0 |
|
7.15 (Air Pressure Test on containers consisting of finished cell/Battery) |
10000.0 |
|
|