1 |
IS 1745 (2018) - Petroleum hydrocarbon solvents - Specification (Third Revision) |
Petroleum hydrocarbon solvents - Specification (Third Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
Cl 1 Table 1 (ANNEXURE) |
10000.0 |
|
|
2 |
IS 3203 (1982) - Methods of testing local thickness of electroplated coatings (First Revision) |
Methods of testing local thickness of electroplated coatings (First Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
IS 3203 (Coating thickness) |
3000.0 |
|
|
3 |
13209 (1991) - Indelible Ink-Specification |
Indelible Ink-Specification |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
3.2 (Description) |
1000.0 |
|
3.3 (Colour) |
1000.0 |
|
3.4 (Acidity) |
1000.0 |
|
3.5 (Total solids) |
1000.0 |
|
3.6 (Development) |
1000.0 |
|
3.7.1 (Performance- Resistance to Bleaching) |
1000.0 |
|
3.7.2 (Performance- Resistance to organic solvents) |
1000.0 |
|
|
4 |
IS 5352 : Part 1 (1999) - Textile – Glass and glass-polyester fibre woven tapes Part 1 Specification (third revision) |
Textile – Glass and glass-polyester fibre woven tapes Part 1 Specification (third revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
5.1 (Alkali percent as Sodium Oxide) |
2000.0 |
|
5.1 (Identification of Yarn) |
2000.0 |
|
5.2 (Weave) |
500.0 |
|
5.3 (Locking Thread) |
500.0 |
|
5.4 (Centre Marking) |
500.0 |
|
5.5 (Identification of Types of Tapes) |
500.0 |
|
6.1 (Thickness) |
1000.0 |
|
6.2 (Width) |
500.0 |
|
6.3 (Length) |
500.0 |
|
6.4 (Tensile Strength) |
2000.0 |
|
6.5 (Effect of heating in air) |
3000.0 |
|
6.5 (Glass Content) |
2000.0 |
|
|
5 |
IS 7307 : Part 1 (1974) - Approval tests for welding procedures: Part 1 fusion welding of steel |
Approval tests for welding procedures: Part 1 fusion welding of steel |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
7.2.1 (Magnetic Particle Testing) |
1000.0 |
|
7.2.1 (Penetrant Testing) |
1000.0 |
|
7.2.1 (Ultrasonic Testing) |
1000.0 |
|
7.2.1 (Radiographic Examination) |
1000.0 |
|
7.3.1 (Macro Examination) |
3000.0 |
|
7.3.1 (Hardness Survey) |
2000.0 |
|
7.3.1 (Transverse Tensile Test) |
3000.0 |
|
7.3.1 (All weld tensile test) |
3000.0 |
|
7.3.1 (Bend Test) |
3000.0 |
|
7.3.1 (Fillet weld fracture test) |
3000.0 |
|
|
6 |
NTH/NR/RPPT/Nitrile Insulation (2025) - Nitrile Insulation |
Nitrile Insulation |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
Firm's requirement (Results of Test) |
10000.0 |
|
|
7 |
IS 1838 (Part 3) (2011) - PREFORMED FILLERS FOR EXPANSION JOINTS IN CONCRETE PAVEMENTS AND STRUCTURES
(NON-EXTRUDING AND RESILIENT TYPE) |
PREFORMED FILLERS FOR EXPANSION JOINTS IN CONCRETE PAVEMENTS AND STRUCTURES
(NON-EXTRUDING AND RESILIENT TYPE) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
5 (Dimensions) |
3000.0 |
|
Table 1(i) (Resistance to Handling) |
2000.0 |
|
Table 1(ii) (Recovery) |
5000.0 |
|
Table 1(iii) (Compression) |
5000.0 |
|
Table 1(iv) (Extrusion) |
2000.0 |
|
Table 1(v) (Water Absorption) |
2000.0 |
|
Table 1(vi) (Density) |
1000.0 |
|
Table 1(vii) (Weathering) |
25000.0 |
|
|
8 |
NTH/NR/IRCON/Seat Plate (2025) - Seat Plate |
Seat Plate |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
Firm's requirement (Results of Test) |
5000.0 |
|
|
9 |
NTH/NR/IRCON/Booted Sleeper Pad (2025) - Booted Sleeper Pad |
Booted Sleeper Pad |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
Firm's Requirements (Results of Test) |
3000.0 |
|
|
10 |
NTH/NR/IRCON/Rubber Boot (2025) - Rubber Boot |
Rubber Boot |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
Firm's requirement (Results of Test) |
13000.0 |
|
|
11 |
NTH/NR/IRCON/PVC Membrane (2025) - PVC Water Proofing Membrane |
PVC Water Proofing Membrane |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
Firm's requirement (Results of Test) |
36000.0 |
|
|
12 |
NTH/NR/IRCON/Geotextile (2025) - Non Woven Geotextiles |
Non Woven Geotextiles |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
Firm's requirement (Results of Test) |
10000.0 |
|
|
13 |
IS 16532 (2017) - APP Modified Bituminous Waterproofing and DampProofing Membrane with Polyester
Reinforcement - Specification |
APP Modified Bituminous Waterproofing and DampProofing Membrane with Polyester
Reinforcement - Specification |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
5.1 (Dimensions) |
1000.0 |
|
5.2 (Weight (GSM)) |
1000.0 |
|
Table 4 (i) (Thickness of Membrane) |
500.0 |
|
Table 4 (ii) (Cold Flexibility) |
2000.0 |
|
Table 4 (iii) (Softening Point) |
1500.0 |
|
Table 4 (iv) (Tensile Strength, Longitudinal) |
1000.0 |
|
Table 4 (iv) (Tensile Strength, Transverse) |
1000.0 |
|
Table 4 (v) (Elongation, Longitudinal) |
500.0 |
|
Table 4 (v) (Elongation, Tarnsverse) |
500.0 |
|
Table 4 (vi) (Tear Strength, Longitudinal) |
1000.0 |
|
Table 4 (vi) (Tear Strength, Transverse) |
1000.0 |
|
Table 4 (vii) (Heat Resistance) |
1000.0 |
|
Table 4 (viii) (Penetration @25°C, 100g, 5s) |
2000.0 |
|
Table 4 (ix) (Water Absorption) |
1000.0 |
|
Table 4 (x) (Dimension stability, longitudinal/transverse) |
1000.0 |
|
Table 4 (xi) (Pressure Head Test) |
1000.0 |
|
4.1.1 (Type of Reinforcement) |
1000.0 |
|
|
14 |
IS 1180 : Part 1 (2014) - Outdoor Type Oil Immersed Distribution Transformers - Specification Part 1 Mineral Oil Immersed (Fourth Revision) ( 501kVA TO 1000 kVA ) [501kVA TO 1000 kVA] |
Outdoor Type Oil Immersed Distribution Transformers - Specification Part 1 Mineral Oil Immersed (Fourth Revision) ( 501kVA TO 1000 kVA ) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
21.3(b) (Temperature Rise Test) |
35000.0 |
|
21.2(a) (Measurement of Winding Resistance) |
1000.0 |
|
21.2(b) (Measurement of voltage ratio and, check of voltage vector relationship) |
1500.0 |
|
21.5.1.121.5.2.121.5.3.1 (Vacuum Pressure (Type Test)) |
15000.0 |
|
21.5.1.221.5.2.221.5.3.2 (Pressure test (routine)) |
5000.0 |
|
21.4.(d) (Adhesion by Tape Test) |
5000.0 |
|
21.5.1.321.5.2.321.5.3.3 (Oil leakage test) |
7000.0 |
|
21.2(c) (Measurement of impedance voltage (principal tapping), short circuit impedance and load loss (At 50% and 100% load)) |
7000.0 |
|
7.9 & 8.9 (Measurement of Permissible flux density and over fluxing) |
20000.0 |
|
21.4( c) (Measurement of No load current at 112.5 percent voltage) |
2000.0 |
|
21.2(e) (Measurement of insulation resistance) |
1500.0 |
|
21.2(d) (Measurement of no Load and loss and current) |
6000.0 |
|
21.2(f) (lnduced Over Voltage withstand test) |
3000.0 |
|
21.4(a) (Determination of sound levels) |
6000.0 |
|
21.4( e) (BDV of Oil in the transformer) |
10000.0 |
|
21.3(a) (Lightning Impulse Voltage Test) |
50000.0 |
|
21.2(g) (AC High Voltage Withstand Test) |
2500.0 |
|
As per CBIP Manual No. 317 Cl. (Harmonics of No-load Current) |
12000.0 |
|
As per CBIP No. 317 Cl. 3.10 (Zero Sequence Impedance Measurement) |
5000.0 |
|
As per CBIP No. 317 Cl. 3.10 (Magnetic Balance Test) |
5000.0 |
|
N.A. (Unbalance Current) |
5000.0 |
|
|
15 |
IS 1180 : Part 1 (2014) - Outdoor Type Oil Immersed Distribution Transformers - Specification Part 1 Mineral Oil Immersed (Fourth Revision) ( 101kVA to 200KVA ) [101kVA to 200KVA] |
Outdoor Type Oil Immersed Distribution Transformers - Specification Part 1 Mineral Oil Immersed (Fourth Revision) ( 101kVA to 200KVA ) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
21.3(b) (Temperature Rise Test) |
24000.0 |
|
21.2(a) (Measurement of Winding Resistance) |
1000.0 |
|
21.2(b) (Measurement of voltage ratio and, check of voltage vector relationship) |
1500.0 |
|
21.5.1.121.5.2.121.5.3.1 (Vacuum Pressure (Type Test)) |
10000.0 |
|
21.5.1.221.5.2.221.5.3.2 (Pressure test (routine)) |
5000.0 |
|
21.4.(d) (Adhesion by Tape Test) |
5000.0 |
|
21.5.1.321.5.2.321.5.3.3 (Oil leakage test) |
7000.0 |
|
21.2(c) (Measurement of impedance voltage (principal tapping), short circuit impedance and load loss (At 50% and 100% load)) |
5000.0 |
|
7.9 & 8.9 (Measurement of Permissible flux density and over fluxing) |
10000.0 |
|
21.4( c) (Measurement of No load current at 112.5 percent voltage) |
2000.0 |
|
21.2(e) (Measurement of insulation resistance) |
1000.0 |
|
21.2(d) (Measurement of no Load and loss and current) |
5500.0 |
|
21.2(f) (lnduced Over Voltage withstand test) |
2500.0 |
|
21.4(a) (Determination of sound levels) |
5000.0 |
|
21.4( e) (BDV of Oil in the tranformer) |
10000.0 |
|
21.3(a) (Lighting Impulse Voltage Test) |
35000.0 |
|
21.2(g) (AC High Voltage Withstand Test) |
2500.0 |
|
As per CBIP Pub No. 317 Cl. 3.17 (Magnetic Balance Test) |
3000.0 |
|
As per CBIP Manual No. 317 Cl (Harmonics of No-load Current) |
10000.0 |
|
As per CBIP No. 317 Cl. 3.10 (Zero Sequence Impedance Measurement) |
3000.0 |
|
N.A. (Unbalance Current) |
3000.0 |
|
|
16 |
IS 1180 : Part 1 (2014) - Outdoor Type Oil Immersed Distribution Transformers - Specification Part 1 Mineral Oil Immersed (Fourth Revision) ( 1kVA to 100kVA ) [1kVA to 100kVA] |
Outdoor Type Oil Immersed Distribution Transformers - Specification Part 1 Mineral Oil Immersed (Fourth Revision) ( 1kVA to 100kVA ) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
21.3(b) (Temperature Rise Test) |
15000.0 |
|
21.2(a) (Measurement of Winding Resistance) |
700.0 |
|
21.2(b) (Measurement of voltage ratio and, check of voltage vector relationship) |
700.0 |
|
21.5.1.121.5.2.121.5.3.1 (Vacuum Pressure (Type Test)) |
6000.0 |
|
21.5.1.221.5.2.221.5.3.2 (Pressure test (routine)) |
3500.0 |
|
21.4.(d) (Adhesion by Tape Test) |
5000.0 |
|
21.5.1.321.5.2.321.5.3.3 (Oil leakage test) |
5000.0 |
|
21.2(c) (Measurement of impedance voltage (principal tapping), short circuit impedance and load loss (At 50% and 100% load)) |
3000.0 |
|
7.9 & 8.9 (Measurement of Permissible flux density and over fluxing) |
6500.0 |
|
21.4( c) (Measurement of No load current at 112.5 percent voltage) |
2000.0 |
|
21.2(e) (Measurement of insulation resistance) |
700.0 |
|
21.2(d) (Measurement of no Load and loss and current) |
3000.0 |
|
21.2(f) (lnduced Over Voltage withstand test) |
1200.0 |
|
21.4(a) (Determination of sound levels) |
5000.0 |
|
21.4( e) (BDV of Oil in the tranformer) |
10000.0 |
|
21.3(a) (Lighting Impulse Voltage Test) |
25000.0 |
|
21.2(g) (AC High Voltage Withstand Test) |
1200.0 |
|
As per CBIP Pub No. 317 Cl. 3.17 (Magnetic Balance Test) |
2000.0 |
|
As per CBIP Manual No. 317 Cl (Harmonics of No-load Current) |
6000.0 |
|
As per CBIP No. 317 Cl. 3.10 (Zero Sequence Impedance Measurement) |
2000.0 |
|
N.A. (Unbalance Current) |
2000.0 |
|
|
17 |
IS 1180 : Part 1 (2014) - Outdoor Type Oil Immersed Distribution Transformers - Specification Part 1 Mineral Oil Immersed (Fourth Revision) ( 201kVA TO 500kVA ) [201kVA TO 500kVA] |
Outdoor Type Oil Immersed Distribution Transformers - Specification Part 1 Mineral Oil Immersed (Fourth Revision) ( 201kVA TO 500kVA ) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
21.3(b) (Temperature Rise Test) |
30000.0 |
|
21.2(a) (Measurement of Winding Resistance) |
1000.0 |
|
21.2(b) (Measurement of voltage ratio and, check of voltage vector relationship) |
1500.0 |
|
21.5.1.121.5.2.121.5.3.1 (Vacuum Pressure (Type Test)) |
15000.0 |
|
21.5.1.221.5.2.221.5.3.2 (Pressure test (routine)) |
5000.0 |
|
21.4.(d) (Adhesion by Tape Test) |
5000.0 |
|
21.5.1.321.5.2.321.5.3.3 (Oil leakage test) |
7000.0 |
|
21.2(c) (Measurement of impedance voltage (principal tapping), short circuit impedance and load loss (At 50% and 100% load)) |
6000.0 |
|
7.9 & 8.9 (Measurement of Permissible flux density and over fluxing) |
15000.0 |
|
21.4( c) (Measurement of No load current at 112.5 percent voltage) |
2000.0 |
|
21.2(e) (Measurement of insulation resistance) |
1000.0 |
|
21.2(d) (Measurement of no Load and loss and current) |
5500.0 |
|
21.2(f) (lnduced Over Voltage withstand test) |
2500.0 |
|
21.4(a) (Determination of sound levels) |
6000.0 |
|
21.4( e) (BDV of Oil in the tranformer) |
10000.0 |
|
21.3(a) (Lightning Impulse Voltage Test) |
40000.0 |
|
21.2(g) (AC High Voltage Withstand Test) |
2500.0 |
|
As per CBIP Manual No. 317 Cl (Harmonics of No-load Current) |
12000.0 |
|
As per CBIP No. 317 Cl. 3.10 (Zero Sequence Impedance Measurement) |
4000.0 |
|
As per CBIP No. 317 Cl. 3.10 (Magnetic Balance Test) |
4000.0 |
|
N.A. (Unbalance Current) |
4000.0 |
|
|
18 |
IS:3400 PT-22 1984 - METHODS OF TEST FOR VULCANIZED RUBBER Sulphur content only |
METHODS OF TEST FOR VULCANIZED RUBBER Sulphur content only |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
Cl 4 .A-3 (TOTAL SULPHUR CONTENT % by mass) |
7000.0 |
|
|
19 |
IS 758 (2023) - Medical Textiles - Cotton Absorbent Gauze - Specification |
Medical Textiles - Cotton Absorbent Gauze - Specification |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
As per specification (Results of Test) |
1000.0 |
|
|
20 |
IS 758 (1988) - Specification for cotton gauze, absorbent, non-sterilized (fourth revision) |
Specification for cotton gauze, absorbent, non-sterilized (fourth revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
21 |
IS 17508 (2020) - Disposable Adult Incontinence Diaper - Specification |
Disposable Adult Incontinence Diaper - Specification |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
As per specifictaion (Results of Test) |
1000.0 |
|
|
22 |
NTH/NR/XR/2024/School Uniform/01 (2025) - School Uniform |
School Uniform |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
As per specification (Results of Test) |
1000.0 |
|
|
23 |
IS 17509 (2021) - Disposable Baby Diaper Specification |
Disposable Baby Diaper Specification |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
As per Specification (Results of Test) |
1000.0 |
|
|
24 |
CUSTOM - Water |
Water |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
25 |
398 (Part-4) (1994) - ALUMINIUM CONDUCTORS FOR OVERHEAD TRANSMISSION PURPOSES,
PART 4 ALUMINIUM ALLOY STRANDED CONDUCTORS (ALUMINIUM-MAGNESIUM-SILICON TYPE) |
ALUMINIUM CONDUCTORS FOR OVERHEAD TRANSMISSION PURPOSES,
PART 4 ALUMINIUM ALLOY STRANDED CONDUCTORS (ALUMINIUM-MAGNESIUM-SILICON TYPE) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
3.1.4 (Lay Ratio) |
1000.0 |
|
6 (Freedom From Defects) |
1000.0 |
|
7.1 (Wire Diameter) |
1000.0 |
|
12.2.1 (Breaking Load Test of Strand) |
3000.0 |
|
12.3 (Elongation Test) |
3000.0 |
|
12.4 (Resistance Test) |
2000.0 |
|
8 (Joints in Wires) |
1000.0 |
|
12.2 (Breaking Load Test of Wire) |
3000.0 |
|
|
26 |
NTH/NER/Custom/2022/03 - Chemical General |
Chemical General |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
1 (Silica (as SiO2), % by mass) |
1000.0 |
|
|
27 |
IS 1891 : Part 1 (2021) - CONVEYOR AND ELEVATOR TEXTILE BELTING – SPECIFICATION PART 1 GENERAL PURPOSE BELTING (Fifth Revision) |
CONVEYOR AND ELEVATOR TEXTILE BELTING – SPECIFICATION PART 1 GENERAL PURPOSE BELTING (Fifth Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
As per Specification (Results of Test) |
5000.0 |
|
|
28 |
IS 3735 (1996) - Canvas Shoes, Rubber Sole |
Canvas Shoes, Rubber Sole |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
As per Specification (Results of Test) |
5000.0 |
|
|
29 |
IS 13893 (1994) - Polyurethane soles semirigid - specification |
Polyurethane soles semirigid - specification |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
As per specification (Results of Test) |
5000.0 |
|
|
30 |
IS 10702 (1992) - Rubber hawal chappal - Specification (Second Revision) |
Rubber hawal chappal - Specification (Second Revision) |
- View breakup
-
Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
As per Specification (Results of Test) |
5000.0 |
|
|