| 1 |
National Test House (NER), Guwahati
| IS : 7098(Part 1)1988, Reaff 2020 Amdt-5 (1988) - Specification for Cross linked Polyethylene Insulated PVC Sheathed Cable
Part 1 for working voltage upto and Including 1100Volt |
Specification for Cross linked Polyethylene Insulated PVC Sheathed Cable
Part 1 for working voltage upto and Including 1100Volt |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 15.1 (Type tests ( XLPE insulated, PVC sheathed, Single Core)) |
20000.0 |
|
| 15.1 (Type tests (XLPE insulated, PVC sheathed, Two Core )) |
22000.0 |
|
| 15.1 (Type tests ( XLPE insulated, PVC sheathed, Three Core )) |
24000.0 |
|
| 15.1 (Type tests (XLPE insulated, PVC sheathed, Three and Half or four core)) |
26000.0 |
|
| 15.2 (Acceptance tests ( XLPE insulated, PVC sheathed, Single Core )) |
12000.0 |
|
| 15.2 (Acceptance tests ( XLPE insulated, PVC sheathed, Two Core )) |
14000.0 |
|
| 15.2 (Acceptance tests ( XLPE insulated, PVC sheathed, Three Core )) |
16000.0 |
|
| 15.2 (Acceptance tests ( XLPE insulated, PVC sheathed, Three and Half or four core )) |
18000.0 |
|
| 15.1 (Type tests ( Single Core FRLS Cable)) |
35000.0 |
|
| 15.1 (Type tests ( Two core FRLS Cable )) |
40000.0 |
|
| 15.1 (Type tests (Three core FRLS Cable)) |
45000.0 |
|
| 15.1 (Type tests ( Three and Half or four core FRLS Cable)) |
50000.0 |
|
| 15.2 (Acceptance tests (Single core FRLS Cable)) |
12000.0 |
|
| 15.2 (Acceptance tests ( Two core FRLS Cable )) |
17000.0 |
|
| 15.2 (Acceptance tests ( Three coreFRLS Cable )) |
22000.0 |
|
| 15.2 (Acceptance tests ( Three and Half or four core FRLS Cable )) |
27000.0 |
|
|
| 2 |
National Test House (NER), Guwahati
| IS:1554 ( Part 1 ) - 1988 (1988) - SPECIFICATION FOR PVC INSULATED ( HEAVY DUTY ) ELECTRIC CABLES |
SPECIFICATION FOR PVC INSULATED ( HEAVY DUTY ) ELECTRIC CABLES |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 15.1(a).(1),15.2(a) (Annealing test ( for copper )) |
1000.0 |
|
| 15.2(b),15.1(a).(2) (Tensile test ( for aluminium )) |
1000.0 |
|
| 15.1(a).(3),15.2(c) (Wrapping test ( for aluminium )) |
500.0 |
|
| 15.1(a).(4),15.2(d),15.3(a) (Conductor resistance test) |
2000.0 |
|
| 15.2(e),15.1(c) (Test for thickness of insulation and sheath) |
1000.0 |
|
| 15.2(f), (Tensile strength and elongation at break of insulation and sheath) |
1000.0 |
|
| 15.2(g),15.1(e) (Insulation resistance test) |
1500.0 |
|
| 15.2(h),15.1(g) (High voltage test at room temperature) |
1000.0 |
|
| 15.1(b) (Test for armouring wires/strips-Dimension) |
1000.0 |
|
| 15.1(b) (Test for armouring wires/strips - Tensile strength) |
1000.0 |
|
| 15.1(b) (Test for armouring wires/strips - Elongation at break) |
1000.0 |
|
| 15.1(b) (Test for armouring wires/strips - Torsion test for round wires) |
1000.0 |
|
| 15.1(b) (Test for armouring wires/strips - Winding test for formed wires) |
1000.0 |
|
| 15.1(b) (Test for armouring wires/strips - Resistivity) |
2000.0 |
|
| 15.1.1 , 15.2.1 (Oxygen index test) |
5000.0 |
|
| 15.1.1 , 15.2.1 (Temperature index) |
5000.0 |
|
| 15.1.1 , 15.2.1 (Test for halogen acid gas evolution) |
5000.0 |
|
| 15.1.1 , 15.2.1 (Smoke density) |
5000.0 |
|
| 15.1(b) (Test for armouring wires/strips - Elongation at break) |
1000.0 |
|
| 15.1(b) (Test for armouring wires/strips - Torsion test for round wires) |
1000.0 |
|
| 15.1(b) (Test for armouring wires/strips - Winding test for formed wires) |
1000.0 |
|
| 15.1(d) (Physical tests for insulation and outer sheath: - Tensile strength and elongation at break) |
1500.0 |
|
| 15.1(d) (Physical tests for insulation and outer sheath: - Ageing in air oven) |
2000.0 |
|
| 15.1(d) (Physical tests for insulation and outer sheath: - Shrinkage test) |
500.0 |
|
| 15.1(d) (Physical tests for insulation and outer sheath: - Hot deformation) |
500.0 |
|
| 15.1(d) (Physical tests for insulation and outer sheath: - Loss of mass in air oven) |
1500.0 |
|
| 15.1(d) (Physical tests for insulation and outer sheath: - Heat shock test) |
500.0 |
|
| 15.1(d) (Physical tests for insulation and outer sheath: - Thermal stability) |
1000.0 |
|
| 15.1(f) (High voltage test ( water immersion test )) |
3000.0 |
|
| 15.1(h) (Flammability test) |
500.0 |
|
| - (Test on 2nd core) |
2000.0 |
|
| - (Test on 3rd core) |
2000.0 |
|
| - (Test on 4th core) |
2000.0 |
|
| Tests (Tests) |
22000.0 |
|
| Tests (Tests) |
110000.0 |
|
|
| 3 |
National Test House (NER), Guwahati
| IS 1554 : Part 1 (1988) - SPECIFICATION FOR PVC INSULATED ( HEAVY DUTY ) ELECTRIC CABLES |
SPECIFICATION FOR PVC INSULATED ( HEAVY DUTY ) ELECTRIC CABLES |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 15.1 (Type Test - Single Core Non-Mining) |
20000.0 |
|
| 15.1 (Type Test - Two core Non-Mining) |
22000.0 |
|
| 15.1 (Type Test - Three core Non-Mining) |
24000.0 |
|
| 15.1 (Type Test - Three and Half or four core Non-Mining) |
26000.0 |
|
| 15.2 (Acceptance tests - Single core Non-Mining) |
11500.0 |
|
| 15.2 (Acceptance tests - Two core Non-Mining) |
13500.0 |
|
| 15.2 (Acceptance tests - Three core Non-Mining) |
15500.0 |
|
| 15.2 (Acceptance tests(Three and Half or four core FRLS Cable)) |
26500.0 |
|
| 15.1 (Type Test - Single Core FRLS Cable) |
35000.0 |
|
| 15.1 (Type Test) |
40000.0 |
|
| 15.1 (Type Tests) |
75000.0 |
|
| Acceptance Tests (Acceptance Tests, Category-01.) |
14000.0 |
|
| Tests (Tests) |
44000.0 |
|
| 15.1 (Type Test (Two core FRLS Cable)) |
40000.0 |
|
| 15.1 (Type Test(Three core FRLS Cable)) |
45000.0 |
|
| 15.1 (Type Test(Three and Half or four core FRLS Cable)) |
50000.0 |
|
|
| 4 |
National Test House (NER), Guwahati
| Custom - Specification for Cover Paper |
Specification for Cover Paper |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| - (Vide Annexure) |
70000.0 |
|
|
| 5 |
National Test House (NER), Guwahati
| Custom - Specification for Text Paper |
Specification for Text Paper |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| - (Vide Annexure) |
65000.0 |
|
|
| 6 |
National Test House (WR), Mumbai
| Custom Plywood / Timber based products - Plywood / Timber based products [- -] |
Plywood / Timber based products |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Tests (Identification of Type of material) |
12500.0 |
|
|
| 7 |
National Test House (NR), Ghaziabad
| IS 854 (2021) - Textiles Handloom cotton turkish honeycomb and huckaback towels and towelling cloth Specification |
Textiles Handloom cotton turkish honeycomb and huckaback towels and towelling cloth Specification |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5.1 (Count of Yarn (Warp)) |
500.0 |
|
| 5.1 (Count of yarn (Weft)) |
500.0 |
|
| 5.1 (Ends/dm) |
500.0 |
|
| 5.1 (Picks/dm) |
500.0 |
|
| 5.1 (Mass) |
1000.0 |
|
| 5.1 (Weave) |
500.0 |
|
| 5.1 (Breaking Load (Warp)) |
1000.0 |
|
| 5.1 (Breaking Load (Weft)) |
1000.0 |
|
| 5.2 (Identification of material) |
2000.0 |
|
| 5.2 (Dimensional Change) |
2000.0 |
|
| 5.2 (Scouring loss) |
2000.0 |
|
| 5.2 (Wettability) |
1000.0 |
|
|
| 8 |
National Test House (ER), Kolkata
| Document No. NTH/ER/RR/MC(C)/SOP/D/23 - Procedure For Calibration of Coating Thickness Meter |
Procedure For Calibration of Coating Thickness Meter |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 8 (Thickness) |
2000.0 |
|
|
| 9 |
National Test House (ER), Kolkata
| Document No. NTH/ER/RR/MC(C)/SOP/D/28 (-) - Procedure For Calibration Of Calibration of Dial & Digital Thickness Gauge |
Procedure For Calibration Of Calibration of Dial & Digital Thickness Gauge |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 7 (Thickness) |
2000.0 |
|
|
| 10 |
National Test House (ER), Kolkata
| ASTM E2309 (2016) - Standard Practices for Verification of Displacement Measuring Systems and Devices Used in Material Testing Machines |
Standard Practices for Verification of Displacement Measuring Systems and Devices Used in Material Testing Machines |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 9 & 10 (Displacement) |
5500.0 |
|
|
| 11 |
National Test House (ER), Kolkata
| ASTM E2658 (2015) - Standard Practices for Verification of Speed for Material Testing Machines |
Standard Practices for Verification of Speed for Material Testing Machines |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 9 & 10 (Speed) |
5500.0 |
|
|
| 12 |
National Test House (ER), Kolkata
| BS 6468 (2008) - Specification for Depth micrometer |
Specification for Depth micrometer |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| Annexure A (Depth) |
2000.0 |
|
|
| 13 |
National Test House (ER), Alipore
| 14255:1995 - IS 14255:1995 - Aerial bunched cables - For working voltages up to and including 1100 Volts - Specification: REC NTH Kolkata |
IS 14255:1995 - Aerial bunched cables - For working voltages up to and including 1100 Volts - Specification: REC NTH Kolkata |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| REC (As per NTH (HQ) Letter no. NTH/HQ/Test Fees/Revision/2025-26 dated 23.02.2026
Tests on Phase/Street Light Conductor: Tensile Test, CR Test, IR Test
Test on Messenger Conductor: Breaking Load, Elongation, CR
Test on Insulation and Sheath: Tensile and Elongation on break, Hot set, Thickness of Insulation and Sheath, High Voltage) |
8500.0 |
|
|
| 14 |
National Test House (NR), Ghaziabad
| Custom Nano Urea FCO - Nano Urea FCO |
Nano Urea FCO |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Please see the Annexure) |
10000.0 |
|
|
| 15 |
National Test House (WR), Mumbai
| Rubber product(Customized) - Rubber product(Customized) |
Rubber product(Customized) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| - (Density) |
1000.0 |
|
| - (Hardness(Shore A)) |
1000.0 |
|
| - (Elongation at Break(%)) |
1500.0 |
|
| - (Tensile Strength) |
1500.0 |
|
| - (Modulus of Elasticity) |
2000.0 |
|
|
| 16 |
National Test House (NR), Ghaziabad
| IS 7739 : Part 5 (1976) - Code of practice for preparation of metallographic specimens: Part 5 iron and steel and their examination |
Code of practice for preparation of metallographic specimens: Part 5 iron and steel and their examination |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| IS 7739 (Microstructure) |
3000.0 |
|
|
| 17 |
National Test House (ER), Kolkata
| IS 3416 : Part 2 (1999) - Method for Quantitative Chemical Analysis of Mixtures of Polyester Fibres With Cotton or Regenerated Celluloseÿ- Part 2 : Trichloro Acetic Acid/Methylene Chlori |
Method for Quantitative Chemical Analysis of Mixtures of Polyester Fibres With Cotton or Regenerated Celluloseÿ- Part 2 : Trichloro Acetic Acid/Methylene Chlori |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 9.1 (Polyester Fibre (% by mass)) |
1000.0 |
|
|
| 18 |
National Test House (NWR), Jaipur
| IS 2347 (2006) - Domestic Pressure Cookers |
Domestic Pressure Cookers |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
No Record Found
|
|
| 19 |
National Test House (SR), Chennai
| TNTB & ESC Technical Specification for Footwear(Velcro Sandal) - 2026 - TNTB & ESC Technical Specification for Footwear(Velcro Sandal) - 2026 |
TNTB & ESC Technical Specification for Footwear(Velcro Sandal) - 2026 |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1.0 (Test results of Footwear(Velcro Sandal)) |
7155.0 |
|
|
| 20 |
National Test House (WR), Mumbai
| Customized Specification for PDI - On site Quality assessment |
On site Quality assessment |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| - (On site Quality assessment(acceptance test )) |
50000.0 |
|
|
| 21 |
National Test House (SR), Chennai
| TNTB & ESC Technical Specification for Shoes - 2026 - TNTB & ESC Technical Specification for Shoes - 2026 |
TNTB & ESC Technical Specification for Shoes - 2026 |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1.0 (Test Results of Shoes) |
10755.0 |
|
|
| 22 |
National Test House (SR), Chennai
| IS 1180 : Part 1 (2014) - Outdoor Type Oil Immersed Distribution Transformers - Specification Part 1 Mineral Oil Immersed (Fourth Revision) Three Phase ( 1 kVA to 200KVA ) [1kVA to 200KVA] |
Outdoor Type Oil Immersed Distribution Transformers - Specification Part 1 Mineral Oil Immersed (Fourth Revision) Three Phase ( 1 kVA to 200KVA ) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 21.3(b) (Temperature Rise Test) |
24000.0 |
|
| 21.2(a) (Measurement of Winding Resistance) |
1000.0 |
|
| 21.2(b) (Measurement of voltage ratio and, check of voltage vector relationship) |
1500.0 |
|
| 21.5.1.121.5.2.121.5.3.1 (Vacuum Pressure (Type Test)) |
10000.0 |
|
| 21.5.1.221.5.2.221.5.3.2 (Pressure test (routine)) |
5000.0 |
|
| 21.4.(d) (Adhesion by Tape Test) |
5000.0 |
|
| 21.5.1.321.5.2.321.5.3.3 (Oil leakage test) |
7000.0 |
|
| 21.2(c) (Measurement of impedance voltage (principal tapping), short circuit impedance and load loss (At 50% and 100% load)) |
5000.0 |
|
| 7.9 & 8.9 (Measurement of Permissible flux density and over fluxing) |
10000.0 |
|
| 21.4( c) (Measurement of No load current at 112.5 percent voltage) |
2000.0 |
|
| 21.2(e) (Measurement of insulation resistance) |
1000.0 |
|
| 21.2(d) (Measurement of no Load and loss and current) |
5500.0 |
|
| 21.2(f) (lnduced Over Voltage withstand test) |
2500.0 |
|
| 21.4(a) (Determination of sound levels) |
5000.0 |
|
| 21.4( e) (BDV of Oil in the tranformer) |
10000.0 |
|
| 21.3(a) (Lighting Impulse Voltage Test) |
35000.0 |
|
| 21.2(g) (AC High Voltage Withstand Test) |
2500.0 |
|
| As per CBIP Pub No. 317 Cl. 3.17 (Magnetic Balance Test) |
3000.0 |
|
| As per CBIP Manual No. 317 Cl (Harmonics of No-load Current) |
10000.0 |
|
| Customer Requirement (Repeat of No-load Loss Measurement) |
5000.0 |
|
| Customer Requirement (Measurement of No-load Loss & Current at 90%, 100% & 110% of Rated Voltage) |
5000.0 |
|
| Customer Requirement (Measurement of Magnetization Current (No Load Current) at 415 V on LV Side) |
2000.0 |
|
|
| 23 |
National Test House (SR), Chennai
| IS 1180 : Part 1 (2014) - Outdoor Type Oil Immersed Distribution Transformers - Specification Part 1 Mineral Oil Immersed (Fourth Revision) ( 501kVA TO 1000 kVA ) [501kVA TO 1000 kVA] |
Outdoor Type Oil Immersed Distribution Transformers - Specification Part 1 Mineral Oil Immersed (Fourth Revision) ( 501kVA TO 1000 kVA ) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 21.3(b) (Temperature Rise Test) |
35000.0 |
|
| 21.2(a) (Measurement of Winding Resistance) |
1000.0 |
|
| 21.2(b) (Measurement of voltage ratio and, check of voltage vector relationship) |
1500.0 |
|
| 21.5.1.121.5.2.121.5.3.1 (Vacuum Pressure (Type Test)) |
15000.0 |
|
| 21.5.1.221.5.2.221.5.3.2 (Pressure test (routine)) |
5000.0 |
|
| 21.4.(d) (Adhesion by Tape Test) |
5000.0 |
|
| 21.5.1.321.5.2.321.5.3.3 (Oil leakage test) |
7000.0 |
|
| 21.2(c) (Measurement of impedance voltage (principal tapping), short circuit impedance and load loss (At 50% and 100% load)) |
7000.0 |
|
| 7.9 & 8.9 (Measurement of Permissible flux density and over fluxing) |
20000.0 |
|
| 21.4( c) (Measurement of No load current at 112.5 percent voltage) |
2000.0 |
|
| 21.2(e) (Measurement of insulation resistance) |
1500.0 |
|
| 21.2(d) (Measurement of no Load and loss and current) |
6000.0 |
|
| 21.2(f) (lnduced Over Voltage withstand test) |
3000.0 |
|
| 21.4(a) (Determination of sound levels) |
6000.0 |
|
| 21.4( e) (BDV of Oil in the transformer) |
10000.0 |
|
| 21.3(a) (Lightning Impulse Voltage Test) |
50000.0 |
|
| 21.2(g) (AC High Voltage Withstand Test) |
2500.0 |
|
| As per CBIP Manual No. 317 Cl. (Harmonics of No-load Current) |
12000.0 |
|
| As per CBIP No. 317 Cl. 3.10 (Zero Sequence Impedance Measurement) |
5000.0 |
|
| As per CBIP No. 317 Cl. 3.10 (Magnetic Balance Test) |
5000.0 |
|
| N.A. (Unbalance Current) |
5000.0 |
|
|
| 24 |
National Test House (SR), Chennai
| IS 1180 : Part 1 (2014) - Outdoor Type Oil Immersed Distribution Transformers - Specification Part 1 Mineral Oil Immersed (Fourth Revision) ( 201kVA TO 500kVA ) [201kVA TO 500kVA] |
Outdoor Type Oil Immersed Distribution Transformers - Specification Part 1 Mineral Oil Immersed (Fourth Revision) ( 201kVA TO 500kVA ) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 21.3(b) (Temperature Rise Test) |
30000.0 |
|
| 21.2(a) (Measurement of Winding Resistance) |
1000.0 |
|
| 21.2(b) (Measurement of voltage ratio and, check of voltage vector relationship) |
1500.0 |
|
| 21.5.1.121.5.2.121.5.3.1 (Vacuum Pressure (Type Test)) |
15000.0 |
|
| 21.5.1.221.5.2.221.5.3.2 (Pressure test (routine)) |
5000.0 |
|
| 21.4.(d) (Adhesion by Tape Test) |
5000.0 |
|
| 21.5.1.321.5.2.321.5.3.3 (Oil leakage test) |
7000.0 |
|
| 21.2(c) (Measurement of impedance voltage (principal tapping), short circuit impedance and load loss (At 50% and 100% load)) |
6000.0 |
|
| 7.9 & 8.9 (Measurement of Permissible flux density and over fluxing) |
15000.0 |
|
| 21.4( c) (Measurement of No load current at 112.5 percent voltage) |
2000.0 |
|
| 21.2(e) (Measurement of insulation resistance) |
1000.0 |
|
| 21.2(d) (Measurement of no Load and loss and current) |
5500.0 |
|
| 21.2(f) (lnduced Over Voltage withstand test) |
2500.0 |
|
| 21.4(a) (Determination of sound levels) |
6000.0 |
|
| 21.4( e) (BDV of Oil in the tranformer) |
10000.0 |
|
| 21.3(a) (Lightning Impulse Voltage Test) |
40000.0 |
|
| 21.2(g) (AC High Voltage Withstand Test) |
2500.0 |
|
| As per CBIP Manual No. 317 Cl (Harmonics of No-load Current) |
12000.0 |
|
| As per CBIP No. 317 Cl. 3.10 (Zero Sequence Impedance Measurement) |
4000.0 |
|
| As per CBIP No. 317 Cl. 3.10 (Magnetic Balance Test) |
4000.0 |
|
| N.A. (Unbalance Current) |
4000.0 |
|
|
| 25 |
National Test House (SR), Chennai
| IS 1180 : Part 1 (2014) - Outdoor Type Oil Immersed Distribution Transformers - Specification Part 1 Mineral Oil Immersed (Fourth Revision) Single Phase ( 1kVA to 100kVA ) [1kVA to 100kVA] |
Outdoor Type Oil Immersed Distribution Transformers - Specification Part 1 Mineral Oil Immersed (Fourth Revision) Single Phase ( 1kVA to 100kVA ) |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 21.3(b) (Temperature Rise Test) |
15000.0 |
|
| 21.2(a) (Measurement of Winding Resistance) |
700.0 |
|
| 21.2(b) (Measurement of voltage ratio and, check of voltage vector relationship) |
700.0 |
|
| 21.5.1.121.5.2.121.5.3.1 (Vacuum Pressure (Type Test)) |
6000.0 |
|
| 21.5.1.221.5.2.221.5.3.2 (Pressure test (routine)) |
3500.0 |
|
| 21.4.(d) (Adhesion by Tape Test) |
5000.0 |
|
| 21.5.1.321.5.2.321.5.3.3 (Oil leakage test) |
5000.0 |
|
| 21.2(c) (Measurement of impedance voltage (principal tapping), short circuit impedance and load loss (At 50% and 100% load)) |
3000.0 |
|
| 7.9 & 8.9 (Measurement of Permissible flux density and over fluxing) |
6500.0 |
|
| 21.4( c) (Measurement of No load current at 112.5 percent voltage) |
2000.0 |
|
| 21.2(e) (Measurement of insulation resistance) |
700.0 |
|
| 21.2(d) (Measurement of no Load and loss and current) |
3000.0 |
|
| 21.2(f) (lnduced Over Voltage withstand test) |
1200.0 |
|
| 21.4(a) (Determination of sound levels) |
5000.0 |
|
| 21.4( e) (BDV of Oil in the tranformer) |
10000.0 |
|
| 21.3(a) (Lighting Impulse Voltage Test) |
25000.0 |
|
| 21.2(g) (AC High Voltage Withstand Test) |
1200.0 |
|
| As per CBIP Pub No. 317 Cl. 3.17 (Magnetic Balance Test) |
2000.0 |
|
| As per CBIP No. 317 Cl. 3.10 (Zero Sequence Impedance Measurement) |
2000.0 |
|
| As per CBIP Pub No. 317 Cl. 3.17 (Magnetic Balance Test) |
2000.0 |
|
| As per CBIP Manual No. 317 Cl (Harmonics of No-load Current) |
6000.0 |
|
| As per CBIP No. 317 Cl. 3.10 (Zero Sequence Impedance Measurement) |
2000.0 |
|
|
| 26 |
National Test House (WR), Mumbai
| - - (1969) - Steps for Manholes |
Steps for Manholes |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5.1 (Load test, N) |
4000.0 |
|
| - - (Flexural / Bending test (three point bending)) |
4000.0 |
|
|
| 27 |
National Test House (SR), Chennai
| CUS/SR/NDT/005 - Thickness Measurement |
Thickness Measurement |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1.0 (Thickness measurement) |
1500.0 |
|
|
| 28 |
National Test House (ER), Kolkata
| ANSI/LM - 79 - 19 - ANSI/IES LM -79-19 Approved Method : Optical And Electrical Measurements of Solid state Lighting Products |
ANSI/IES LM -79-19 Approved Method : Optical And Electrical Measurements of Solid state Lighting Products |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 5.0 (Electrical Tests (Voltage, Input Power, Frequency, Current , PF, THD)) |
5000.0 |
|
| 7.0 & 8.0 (Total Luminous flux and Integrated Optical Measurement (Luminous Flux,Luminous Efficacy), Intensity or Optical Angular Distribution Measurements(PeakIntensity, Intensity Distribution, Beam Angle) Luminous) |
10000.0 |
|
| 9.0 (Chromaticity Uniformity Measurement (Correlated Color Temperature, Color Coordinates,Color RenderingIndex) |
10000.0 |
|
| 5.0 (Additional Three Tests for R, G & B) |
3000.0 |
|
| 5.0 (Additional Four Tests for R, G, B & W) |
4000.0 |
|
| 7.0 & 8.0 (Additional Three test for R, G & B) |
15000.0 |
|
| 7.0 & 8.0 (Additional four Tests for R, G, B & W) |
20000.0 |
|
| 9.0 (Additional Three tests for R, G & B) |
15000.0 |
|
| 9.0 (Additional Four Tests for R, G, B & W) |
20000.0 |
|
|
| 29 |
National Test House (ER), Kolkata
| Additional Safety Test on Electronic Controlgear for LED Modules as per Customers Requirement - Additional Safety Test on DC or AC Supplied Electronic Controlgear for LED Modules as per Customers Requirement |
Additional Safety Test on DC or AC Supplied Electronic Controlgear for LED Modules as per Customers Requirement |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 1 (Measurement of Operating Voltage Range) |
2000.0 |
|
| 2 (Case Temperature obtained (Tc)) |
2500.0 |
|
| 3 (Input Over Voltage Protection Test) |
2000.0 |
|
| 4 (Input Under Voltage Protection Test) |
2000.0 |
|
| 5 (Output Overload Protection Test) |
2000.0 |
|
| 6 (Reverse Polarity Protection) |
2000.0 |
|
| 7 ("Particular Requirement For Electronic Lamp Controlgear with means of Protection against Overheating ") |
12000.0 |
|
|
| 30 |
National Test House (SR), Chennai
| BSEN 13348 (2016) - Copper and Copper Alloy - Seamless Round Copper Tube for Medical Gases or vacuum |
Copper and Copper Alloy - Seamless Round Copper Tube for Medical Gases or vacuum |
- View breakup
-
| Clause No. |
Testing Charges (Excl. Of Taxes) |
NABL |
| 6.1 (Chemical Composition (% by mass)) |
2000.0 |
|
| 6.2 (Tensile Strength) |
2000.0 |
|
| 6.2 (Elongation) |
1000.0 |
|
|